Skip to main content
Top
Published in: Radiation Oncology 1/2014

Open Access 01-12-2014 | Research

Feasibility and potential benefits of defining the internal gross tumor volume of hepatocellular carcinoma using contrast-enhanced 4D CT images obtained by deformable registration

Published in: Radiation Oncology | Issue 1/2014

Login to get access

Abstract

Objective

To study the feasibility and the potential benefits of defining the internal gross tumor volume (IGTV) of hepatocellular carcinoma (HCC) using contrast-enhanced 4D CT images obtained by combining arterial-phase (AP) contrast-enhanced (CE) 3D CT and non-contrast-enhanced (NCE) 4D CT images using deformable registration (DR).

Methods

Ten HCC patients who had received radiotherapy beforehand were selected for this study. The following CT simulation images were acquired sequentially: NCE 4D CT in free breathing, NCE 3D CT and APCE 3D CT in end-expiration breath holding. All 4D CT images were sorted into ten phases according to breath cycle (CT00 ~ CT90). Gross tumor volumes (GTVs) were contoured on all CT images and the IGTV-1 was obtained by merging the GTVs in each phase of 4D CT images. The GTV on the APCE 3D CT image was deformably registered to each 4D CT phase image according to liver shape using RayStationTM 3.99.0.7 version treatment planning system. The IGTV-DR was obtained by merging the GTVs after DR on the 4D CT images. Volume differences among the GTVs and between the IGTV-1 and the IGTV-DR were compared.

Results

The edge of most lesions could be definitively identified using APCE 3D CT images compared to NCE 4D and 3D CT images. The GTV volume on APCE 3D CT images increased by an average of 34.79% (P < 0.05). There was no significant difference among the GTV volumes obtained using NCE 4D and 3D CT images (P > 0.05). The GTV volumes after DR on 4D CT different phase images increased by an average of 36.29% (P < 0.05), as was observed using the APCE 3D CT image (P > 0.05). Lastly, the volume of IGTV-DR increased by an average of 19.91% compared to that of IGTV-1 (P < 0.05).

Conclusion

NCE 4D CT imaging alone has the potential risk of missing a partial volume of the HCC. The combination of APCE 3D CT and NCE 4D CT images using the DR technique improved the accuracy of the definition of the IGTV in HCC.
Appendix
Available only for authorised users
Literature
1.
go back to reference Balter JM, Dawson LA, Kazanjian S, McGinn C, Brock KK, Lawrence T, Ten Haken R: Determination of ventilatory liver movement via radiographic evaluation of diaphragm position. Int J Radiat Oncol Biol Phys 2001, 51: 267-270. 10.1016/S0360-3016(01)01649-2CrossRefPubMed Balter JM, Dawson LA, Kazanjian S, McGinn C, Brock KK, Lawrence T, Ten Haken R: Determination of ventilatory liver movement via radiographic evaluation of diaphragm position. Int J Radiat Oncol Biol Phys 2001, 51: 267-270. 10.1016/S0360-3016(01)01649-2CrossRefPubMed
2.
go back to reference Davies SC, Hill AL, Holmes RB, Halliwell M, Jackson PC: Ultrasound quantitation of respiratory organ motion in the upper abdomen. Br J Radiol 1994, 67: 1096-1102. 10.1259/0007-1285-67-803-1096CrossRefPubMed Davies SC, Hill AL, Holmes RB, Halliwell M, Jackson PC: Ultrasound quantitation of respiratory organ motion in the upper abdomen. Br J Radiol 1994, 67: 1096-1102. 10.1259/0007-1285-67-803-1096CrossRefPubMed
3.
go back to reference Suramo I, Paivansalo M, Myllyla V: Cranio-caudal movements of the liver, pancreas and kidneys in respiration. Acta Radiol Diagn (Stockh) 1984, 25: 129-131. Suramo I, Paivansalo M, Myllyla V: Cranio-caudal movements of the liver, pancreas and kidneys in respiration. Acta Radiol Diagn (Stockh) 1984, 25: 129-131.
4.
go back to reference Milano MT, Constine LS, Okunieff P: Normal tissue toxicity after small field hypofractionated stereotactic body radiation. Radiat Oncol 2008, 3: 36. 10.1186/1748-717X-3-36PubMedCentralCrossRefPubMed Milano MT, Constine LS, Okunieff P: Normal tissue toxicity after small field hypofractionated stereotactic body radiation. Radiat Oncol 2008, 3: 36. 10.1186/1748-717X-3-36PubMedCentralCrossRefPubMed
5.
go back to reference Kuo HC, Liu WS, Wu A, Mah D, Chuang KS, Hong L, Yaparpalvi R, Guha C, Kalnicki S: Biological impact of geometric uncertainties: what margin is needed for intra-hepatic tumors? Radiat Oncol 2010, 5: 48. 10.1186/1748-717X-5-48PubMedCentralCrossRefPubMed Kuo HC, Liu WS, Wu A, Mah D, Chuang KS, Hong L, Yaparpalvi R, Guha C, Kalnicki S: Biological impact of geometric uncertainties: what margin is needed for intra-hepatic tumors? Radiat Oncol 2010, 5: 48. 10.1186/1748-717X-5-48PubMedCentralCrossRefPubMed
6.
go back to reference Balter JM, Lam KL, McGinn CJ, Lawrence TS, Ten Haken RK: Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging. Int J Radiat Oncol Biol Phys 1998, 41: 939-943. 10.1016/S0360-3016(98)00130-8CrossRefPubMed Balter JM, Lam KL, McGinn CJ, Lawrence TS, Ten Haken RK: Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging. Int J Radiat Oncol Biol Phys 1998, 41: 939-943. 10.1016/S0360-3016(98)00130-8CrossRefPubMed
7.
go back to reference Ten Haken RK, Balter JM, Marsh LH, Robertson JM, Lawrence TS: Potential benefits of eliminating planning target volume expansions for patient breathing in the treatment of liver tumors. Int J Radiat Oncol Biol Phys 1997, 38: 613-617. 10.1016/S0360-3016(97)00009-6CrossRefPubMed Ten Haken RK, Balter JM, Marsh LH, Robertson JM, Lawrence TS: Potential benefits of eliminating planning target volume expansions for patient breathing in the treatment of liver tumors. Int J Radiat Oncol Biol Phys 1997, 38: 613-617. 10.1016/S0360-3016(97)00009-6CrossRefPubMed
8.
go back to reference Yang W, Fraass BA, Reznik R, Nissen N, Lo S, Jamil LH, Gupta K, Sandler H, Tuli R: Adequacy of inhale/exhale breathhold CT based ITV margins and image-guided registration for free-breathing pancreas and liver SBRT. Radiat Oncol 2014, 9: 11. 10.1186/1748-717X-9-11PubMedCentralCrossRefPubMed Yang W, Fraass BA, Reznik R, Nissen N, Lo S, Jamil LH, Gupta K, Sandler H, Tuli R: Adequacy of inhale/exhale breathhold CT based ITV margins and image-guided registration for free-breathing pancreas and liver SBRT. Radiat Oncol 2014, 9: 11. 10.1186/1748-717X-9-11PubMedCentralCrossRefPubMed
9.
go back to reference Hugo GD, Rosu M: Advances in 4D radiation therapy for managing respiration: part I - 4D imaging. Z Med Phys 2012, 22: 258-271. 10.1016/j.zemedi.2012.06.009PubMedCentralCrossRefPubMed Hugo GD, Rosu M: Advances in 4D radiation therapy for managing respiration: part I - 4D imaging. Z Med Phys 2012, 22: 258-271. 10.1016/j.zemedi.2012.06.009PubMedCentralCrossRefPubMed
10.
go back to reference Moorees J, Bezak E: Four dimensional CT imaging: a review of current technologies and modalities. Australas Phys Eng Sci Med 2012, 35: 9-23. 10.1007/s13246-012-0124-6CrossRefPubMed Moorees J, Bezak E: Four dimensional CT imaging: a review of current technologies and modalities. Australas Phys Eng Sci Med 2012, 35: 9-23. 10.1007/s13246-012-0124-6CrossRefPubMed
11.
go back to reference Baron RL: Understanding and optimizing use of contrast material for CT of the liver. AJR Am J Roentgenol 1994, 163: 323-331. 10.2214/ajr.163.2.8037023CrossRefPubMed Baron RL: Understanding and optimizing use of contrast material for CT of the liver. AJR Am J Roentgenol 1994, 163: 323-331. 10.2214/ajr.163.2.8037023CrossRefPubMed
12.
go back to reference Yamamoto T, Langner U, Loo BW Jr, Shen J, Keall PJ: Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients. Int J Radiat Oncol Biol Phys 2008, 72: 1250-1258. 10.1016/j.ijrobp.2008.06.1937PubMedCentralCrossRefPubMed Yamamoto T, Langner U, Loo BW Jr, Shen J, Keall PJ: Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients. Int J Radiat Oncol Biol Phys 2008, 72: 1250-1258. 10.1016/j.ijrobp.2008.06.1937PubMedCentralCrossRefPubMed
13.
go back to reference Choi BI, Han JK, Cho JM, Choi DS, Han MC, Lee HS, Kim CY: Characterization of focal hepatic tumors. Value of two-phase scanning with spiral computed tomography. Cancer 1995, 76: 2434-2442. 10.1002/1097-0142(19951215)76:12<2434::AID-CNCR2820761206>3.0.CO;2-GCrossRefPubMed Choi BI, Han JK, Cho JM, Choi DS, Han MC, Lee HS, Kim CY: Characterization of focal hepatic tumors. Value of two-phase scanning with spiral computed tomography. Cancer 1995, 76: 2434-2442. 10.1002/1097-0142(19951215)76:12<2434::AID-CNCR2820761206>3.0.CO;2-GCrossRefPubMed
14.
go back to reference Sarrut D: Deformable registration for image-guided radiation therapy. Z Med Phys 2006, 16: 285-297.CrossRefPubMed Sarrut D: Deformable registration for image-guided radiation therapy. Z Med Phys 2006, 16: 285-297.CrossRefPubMed
15.
go back to reference Wijesooriya K, Weiss E, Dill V, Dong L, Mohan R, Joshi S, Keall PJ: Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm. Med Phys 2008, 35: 1251-1260. 10.1118/1.2839120PubMedCentralCrossRefPubMed Wijesooriya K, Weiss E, Dill V, Dong L, Mohan R, Joshi S, Keall PJ: Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm. Med Phys 2008, 35: 1251-1260. 10.1118/1.2839120PubMedCentralCrossRefPubMed
16.
go back to reference van Dam IE, Van Sornsen de Koste JR, Hanna GG, Muirhead R, Slotman BJ, Senan S: Improving target delineation on 4-dimensional CT scans in stage I NSCLC using a deformable registration tool. Radiother Oncol 2010, 96: 67-72. 10.1016/j.radonc.2010.05.003CrossRefPubMed van Dam IE, Van Sornsen de Koste JR, Hanna GG, Muirhead R, Slotman BJ, Senan S: Improving target delineation on 4-dimensional CT scans in stage I NSCLC using a deformable registration tool. Radiother Oncol 2010, 96: 67-72. 10.1016/j.radonc.2010.05.003CrossRefPubMed
17.
go back to reference Huang TC, Liang JA, Dilling T, Wu TH, Zhang G: Four-dimensional dosimetry validation and study in lung radiotherapy using deformable image registration and Monte Carlo techniques. Radiat Oncol 2010, 5: 45. 10.1186/1748-717X-5-45PubMedCentralCrossRefPubMed Huang TC, Liang JA, Dilling T, Wu TH, Zhang G: Four-dimensional dosimetry validation and study in lung radiotherapy using deformable image registration and Monte Carlo techniques. Radiat Oncol 2010, 5: 45. 10.1186/1748-717X-5-45PubMedCentralCrossRefPubMed
18.
go back to reference Jung SH, Yoon SM, Park SH, Cho B, Park JW, Jung J, Park JH, Kim JH, Ahn SD: Four-dimensional dose evaluation using deformable image registration in radiotherapy for liver cancer. Med Phys 2013, 40: 011706. 10.1118/1.4769427CrossRefPubMed Jung SH, Yoon SM, Park SH, Cho B, Park JW, Jung J, Park JH, Kim JH, Ahn SD: Four-dimensional dose evaluation using deformable image registration in radiotherapy for liver cancer. Med Phys 2013, 40: 011706. 10.1118/1.4769427CrossRefPubMed
19.
go back to reference Brock KK, Sharpe MB, Dawson LA, Kim SM, Jaffray DA: Accuracy of finite element model-based multi-organ deformable image registration. Med Phys 2005, 32: 1647-1659. 10.1118/1.1915012CrossRefPubMed Brock KK, Sharpe MB, Dawson LA, Kim SM, Jaffray DA: Accuracy of finite element model-based multi-organ deformable image registration. Med Phys 2005, 32: 1647-1659. 10.1118/1.1915012CrossRefPubMed
20.
go back to reference Hallman JL, Mori S, Sharp GC, Lu HM, Hong TS, Chen GT: A four-dimensional computed tomography analysis of multiorgan abdominal motion. Int J Radiat Oncol Biol Phys 2012, 83: 435-441. 10.1016/j.ijrobp.2011.06.1970CrossRefPubMed Hallman JL, Mori S, Sharp GC, Lu HM, Hong TS, Chen GT: A four-dimensional computed tomography analysis of multiorgan abdominal motion. Int J Radiat Oncol Biol Phys 2012, 83: 435-441. 10.1016/j.ijrobp.2011.06.1970CrossRefPubMed
21.
go back to reference Habermehl D, Debus J, Ganten T, Ganten MK, Bauer J, Brecht IC, Brons S, Haberer T, Haertig M, Jäkel O, Parodi K, Welzel T, Combs SE: Hypofractionated carbon ion therapy delivered with scanned ion beams for patients with hepatocellular carcinoma - feasibility and clinical response. Radiat Oncol 2013, 8: 59. 10.1186/1748-717X-8-59PubMedCentralCrossRefPubMed Habermehl D, Debus J, Ganten T, Ganten MK, Bauer J, Brecht IC, Brons S, Haberer T, Haertig M, Jäkel O, Parodi K, Welzel T, Combs SE: Hypofractionated carbon ion therapy delivered with scanned ion beams for patients with hepatocellular carcinoma - feasibility and clinical response. Radiat Oncol 2013, 8: 59. 10.1186/1748-717X-8-59PubMedCentralCrossRefPubMed
22.
go back to reference Rietzel E, Chen GT, Choi NC, Willet CG: Four-dimensional image-based treatment planning: target volume segmentation and dose calculation in the presence of respiratory motion. Int J Radiat Oncol Biol Phys 2005, 61: 1535-1550. 10.1016/j.ijrobp.2004.11.037CrossRefPubMed Rietzel E, Chen GT, Choi NC, Willet CG: Four-dimensional image-based treatment planning: target volume segmentation and dose calculation in the presence of respiratory motion. Int J Radiat Oncol Biol Phys 2005, 61: 1535-1550. 10.1016/j.ijrobp.2004.11.037CrossRefPubMed
23.
go back to reference Liu J, Wang JZ, Zhao JD, Xu ZY, Jiang GL: Use of combined maximum and minimum intensity projections to determine internal target volume in 4-dimensional CT scans for hepatic malignancies. Radiat Oncol 2012, 7: 11. 10.1186/1748-717X-7-11PubMedCentralCrossRefPubMed Liu J, Wang JZ, Zhao JD, Xu ZY, Jiang GL: Use of combined maximum and minimum intensity projections to determine internal target volume in 4-dimensional CT scans for hepatic malignancies. Radiat Oncol 2012, 7: 11. 10.1186/1748-717X-7-11PubMedCentralCrossRefPubMed
24.
go back to reference Befeler AS, Di Bisceglie AM: Hepatocellular carcinoma: diagnosis and treatment. Gastroenterology 2002, 122: 1609-1619. 10.1053/gast.2002.33411CrossRefPubMed Befeler AS, Di Bisceglie AM: Hepatocellular carcinoma: diagnosis and treatment. Gastroenterology 2002, 122: 1609-1619. 10.1053/gast.2002.33411CrossRefPubMed
25.
go back to reference Fujishima T, Yoshida H, Obi S, Shiina S, Kanda M, Tateishi R, Akamatsu M, Koike Y, Sato S, Teratani T, Kawabe T, Shiratori Y, Omata M: Analysis of factors influencing hepatocellular carcinoma detection: efficient use of computed tomography during arterial portography and during hepatic arteriography. J Gastroenterol 2005, 40: 266-273. 10.1007/s00535-004-1533-4CrossRefPubMed Fujishima T, Yoshida H, Obi S, Shiina S, Kanda M, Tateishi R, Akamatsu M, Koike Y, Sato S, Teratani T, Kawabe T, Shiratori Y, Omata M: Analysis of factors influencing hepatocellular carcinoma detection: efficient use of computed tomography during arterial portography and during hepatic arteriography. J Gastroenterol 2005, 40: 266-273. 10.1007/s00535-004-1533-4CrossRefPubMed
26.
go back to reference Beddar AS, Briere TM, Balter P, Pan T, Tolani N, Ng C, Szklaruk J, Krishnan S: 4D-CT imaging with synchronized intravenous contrast injection to improve delineation of liver tumors for treatment planning. Radiother Oncol 2008, 87: 445-448. 10.1016/j.radonc.2007.12.009CrossRefPubMed Beddar AS, Briere TM, Balter P, Pan T, Tolani N, Ng C, Szklaruk J, Krishnan S: 4D-CT imaging with synchronized intravenous contrast injection to improve delineation of liver tumors for treatment planning. Radiother Oncol 2008, 87: 445-448. 10.1016/j.radonc.2007.12.009CrossRefPubMed
27.
go back to reference Oh D, Lim do H, Park HC, Paik SW, Koh KC, Lee JH, Choi MS, Yoo BC, Lim HK, Lee WJ, Rhim H, Shin SW, Park KB: Early three-dimensional conformal radiotherapy for patients with unresectable hepatocellular carcinoma after incomplete transcatheter arterial chemoembolization: a prospective evaluation of efficacy and toxicity. Am J Clin Oncol 2010, 33: 370-375. 10.1097/COC.0b013e3181b0c298CrossRefPubMed Oh D, Lim do H, Park HC, Paik SW, Koh KC, Lee JH, Choi MS, Yoo BC, Lim HK, Lee WJ, Rhim H, Shin SW, Park KB: Early three-dimensional conformal radiotherapy for patients with unresectable hepatocellular carcinoma after incomplete transcatheter arterial chemoembolization: a prospective evaluation of efficacy and toxicity. Am J Clin Oncol 2010, 33: 370-375. 10.1097/COC.0b013e3181b0c298CrossRefPubMed
28.
go back to reference Ferrant M, Nabavi A, Macq B, Jolesz FA, Kikinis R, Warfield SK: Registration of 3-D intraoperative MR images of the brain using a finite-element biomechanical model. IEEE Trans Med Imaging 2001, 20: 1384-1397. 10.1109/42.974933CrossRefPubMed Ferrant M, Nabavi A, Macq B, Jolesz FA, Kikinis R, Warfield SK: Registration of 3-D intraoperative MR images of the brain using a finite-element biomechanical model. IEEE Trans Med Imaging 2001, 20: 1384-1397. 10.1109/42.974933CrossRefPubMed
29.
go back to reference Liang J, Yan D: Reducing uncertainties in volumetric image based deformable organ registration. Med Phys 2003, 30: 2116-2122. 10.1118/1.1587631CrossRefPubMed Liang J, Yan D: Reducing uncertainties in volumetric image based deformable organ registration. Med Phys 2003, 30: 2116-2122. 10.1118/1.1587631CrossRefPubMed
30.
go back to reference Zhang T, Keller H, Jeraj R, Manon R, Welsh J, Patel R, Fenwick J, Mehta M, Mackie TR, Paliwal B: Breathing synchronized delivery-a new technique for radiation treatment of the targets with respiratory motion. Int J Radiat Oncol Biol Phys 2003, 57: S185-S186. 10.1016/S0360-3016(03)00980-5CrossRef Zhang T, Keller H, Jeraj R, Manon R, Welsh J, Patel R, Fenwick J, Mehta M, Mackie TR, Paliwal B: Breathing synchronized delivery-a new technique for radiation treatment of the targets with respiratory motion. Int J Radiat Oncol Biol Phys 2003, 57: S185-S186. 10.1016/S0360-3016(03)00980-5CrossRef
Metadata
Title
Feasibility and potential benefits of defining the internal gross tumor volume of hepatocellular carcinoma using contrast-enhanced 4D CT images obtained by deformable registration
Publication date
01-12-2014
Published in
Radiation Oncology / Issue 1/2014
Electronic ISSN: 1748-717X
DOI
https://doi.org/10.1186/s13014-014-0221-7

Other articles of this Issue 1/2014

Radiation Oncology 1/2014 Go to the issue