Skip to main content
Log in

Four dimensional CT imaging: a review of current technologies and modalities

  • Review
  • Published:
Australasian Physical & Engineering Sciences in Medicine Aims and scope Submit manuscript

Abstract

Organ motion is a substantial concern in the treatment of thoracic tumours using radiotherapy. A number of technologies have evolved in order to address this both during computed tomography (CT) imaging and radiation delivery. This review paper investigates the various technologies which have been developed in the field of CT scanning as well as their accuracy, cost and the implications of their clinical implementation. The scanning modalities covered include: slow CT, breath hold CT, gated CT and retrospectively correlated CT (4DCT). It was found that there are advantages and drawbacks to each of the mentioned techniques relating to patient dose, scan time, extra equipment and workload. Also some scanning techniques are only compatible with certain treatment modalities which would further influence the decision as to which technologies to implement.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

Similar content being viewed by others

References

  1. Keall PJ, Mageras GS, Balter JM, Emery RS, Forster KM, Jiang SB, Kapatoes JM, Low DA, Murphy MJ, Murray BR, Ramsey CR, Van Herk MB, Vedam SS, Wong JW, Yorke E (2006) The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys 33(10):3874–3900

    Article  PubMed  Google Scholar 

  2. Vedam SS, Kini VR, Keall PJ, Ramakrishnan V, Mostafavi H, Mohan R (2003) Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker. Med Phys 30(4):505–513

    Article  PubMed  CAS  Google Scholar 

  3. Ozhasoglu C, Murphy MJ (2002) Issues in respiratory motion compensation during external-beam radiotherapy. Int J Radiat Oncol Biol Phys 52(5):1389–1399

    Article  PubMed  Google Scholar 

  4. Cui Y, Dy J, Sharp G, Alexander B, Jiang S (2007) Robust fluoroscopic respiratory gating for lung cancer radiotherapy without implanted fiducial markers. Phys Med Biol 52:741–755

    Article  PubMed  Google Scholar 

  5. Suh Y, Sawant A, Venkat R, Keall PJ (2009) Four-dimensional IMRT treatment planning using a DMLC motion-tracking algorithm. Phys Med Biol 54:3821–3835

    Article  PubMed  Google Scholar 

  6. Sawant A, Venkat R, Srivastava V, Carlson D, Povzner S, Cattell H, Keall P (2008) Management of three-dimensional intrafraction motion through real-time DMLC tracking. Med Phys 35(5):2050–2061

    Article  PubMed  Google Scholar 

  7. Kini VR, Vedam SS, Keall PJ, Patil S, Chen C, Mohan R (2003) Patient training in respiratory-gated radiotherapy. Med Dosim 28:7–11

    Article  PubMed  Google Scholar 

  8. George R, Chung TD, Vedam SS, Ramakrishnan V, Mohan R, Weiss E, Keall PJ (2006) Audio-visual biofeedback for respiratory-gated radiotherapy: impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy. Int J Radiat Oncol Biol Phys 65(3):924–933

    Article  PubMed  Google Scholar 

  9. Brandner ED, Wu A, Chen H, Heron D, Kalnicki S, Komanduri K, Gerszten K, Burton S, Ahmed I, Shou Z (2006) Abdominal organ motion measured using 4D CT. Int J Radiat Oncol Biol Phys 65(2):554–560

    Article  PubMed  Google Scholar 

  10. Ford EC, Mageras GS, Yorke E, Ling CC (2003) Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning. Med Phys 30(1):88–97

    Article  PubMed  CAS  Google Scholar 

  11. Gui M, Feng Y, Yi B, Dhople AA, Yu C (2010) Four-dimensional intensity-modulated radiation therapy planning for dynamic tracking using a direct aperture deformation (DAD) method. Med Phys 37(5):1966–1975

    Article  PubMed  Google Scholar 

  12. Keall PJ, Kini VR, Vedam SS, Mohan R (2002) Potential radiotherapy improvements with respiratory gating. Australas Phys Eng Sci Med 25:1–6

    Article  PubMed  CAS  Google Scholar 

  13. Khan F, Bell G, Antony J, Palmer M, Balter P, Bucci K, Chapman M (2009) The use of 4DCT to reduce lung dose: a dosimetric analysis. Med Dosim 34(4):273–278

    Article  PubMed  Google Scholar 

  14. Kubo HD, Len PM, Minohara S-i, Mostafavi H (2000) Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center. Med Phys 27(2):346–353

    Article  PubMed  CAS  Google Scholar 

  15. Langner UW, Keall PJ (2008) Prospective displacement and velocity-based cine 4D CT. Med Phys 35(10):4501–4512

    Article  PubMed  CAS  Google Scholar 

  16. Pan T, Lee T-Y, Rietzel E, Chen GTY (2004) 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. Med Phys 31(2):333–340

    Article  PubMed  Google Scholar 

  17. Suh Y, Weiss E, Zhong H, Fatyga M, Siebers JV, Keall PJ (2008) A deliverable four-dimensional intensity-modulated radiation therapy-planning method for dynamic multileaf collimator tumor tracking delivery. Int J Radiat Oncol Biol Phys 71(5):1526–1536

    Article  PubMed  Google Scholar 

  18. Vedam SS, Keall PJ, Kini VR, Mohan R (2001) Determining parameters for respiration-gated radiotherapy. Med Phys 28(10):2139–2146

    Article  PubMed  CAS  Google Scholar 

  19. Vedam SS, Keall PJ, Kini VR, Mostafavi H, Shukla H, Mohan R (2003) Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. Phys Med Biol 48:45–62

    Article  PubMed  CAS  Google Scholar 

  20. Weiss E, Wijesooriya K, Dill SV, Keall PJ (2007) Tumor and normal tissue motion in the thorax during respiration: analysis of volumetric and positional variations using 4D CT. Int J Radiat Oncol Biol Phys 67(1):296–307

    Article  PubMed  Google Scholar 

  21. D’Souza W, Naqvi S, Yu C (2005) Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study. Phys Med Biol 50:4021–4030

    Article  PubMed  Google Scholar 

  22. Wurm RE, Gum F, Erbel S, Schlenger L, Scheffler D, Agaoglu D, Schild R, Gebauer B, Rogalla P, Plotkin M, Ocran K, Budach V (2006) Image guided respiratory gated hypofractionated Stereotactic Body Radiation Therapy (H-SBRT) for liver and lung tumors: initial experience. Acta Oncol 45(7):881–889

    Article  PubMed  CAS  Google Scholar 

  23. Willoughby TR, Forbes AR, Buchholz D, Langen KM, Wagner TH, Zeidan OA, Kupelian PA, Meeks SL (2006) Evaluation of an infrared camera and X-ray system using implanted fiducials in patients with lung tumors for gated radiation therapy. Int J Radiat Oncol Biol Phys 66(2):568–575

    Article  PubMed  Google Scholar 

  24. Cho B, Suh Y, Dieterich S, Keall P (2008) A monoscopic method for real-time tumour tracking using combined occasional X-ray imaging and continuous respiratory monitoring. Phys Med Biol 53:2837–2855

    Article  PubMed  Google Scholar 

  25. Seppenwoolde Y, Berbeco RI, Nishioka S, Shirato H, Heijmen B (2007) Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: a simulation study. Med Phys 34(7):2774–2784

    Article  PubMed  Google Scholar 

  26. Balter JM, Wright JN, Newell LJ, Friemel B, Dimmer S, Cheng Y, Wong J, Vertatschitsch E, Mate TP (2005) Accuracy of a wireless localization system for radiotherapy. Int J Radiat Oncol Biol Phys 61(3):933–937

    Article  PubMed  Google Scholar 

  27. Willoughby TR, Kupelian PA, Pouliot J, Shinohara K, Aubin M, Roach Iii M, Skrumeda LL, Balter JM, Litzenberg DW, Hadley SW, Wei JT, Sandler HM (2006) Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer. Int J Radiat Oncol Biol Phys 65(2):528–534

    Article  PubMed  Google Scholar 

  28. Kupelian P, Willoughby T, Mahadevan A, Djemil T, Weinstein G, Jani S, Enke C, Solberg T, Flores N, Liu D, Beyer D, Levine L (2007) Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy. Int J Radiat Oncol Biol Phys 67(4):1088–1098

    Article  PubMed  Google Scholar 

  29. Smith RL, Sawant A, Santanam L, Venkat RB, Newell LJ, Cho B-C, Poulsen P, Catell H, Keall PJ, Parikh PJ (2009) Integration of real-time internal electromagnetic position monitoring coupled with dynamic multileaf collimator tracking: an intensity-modulated radiation therapy feasibility study. Int J Radiat Oncol Biol Phys 74(3):868–875

    Article  PubMed  Google Scholar 

  30. Kubo DH, C HB (1996) Respiration gated radiotherapy treatment: a technical study. Phys Med Biol 41:83–91

    Article  PubMed  CAS  Google Scholar 

  31. Low DA, Nystrom M, Kalinin E, Parikh P, Dempsey JF, Bradley JD, Mutic S, Wahab SH, Islam T, Christensen G, Politte DG, Whiting BR (2003) A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. Med Phys 30(6):1254–1263

    Article  PubMed  Google Scholar 

  32. Tewatia D, Zhang T, Tome W, Paliwal B, Metha M (2006) Clinical implementation of target tracking by breathing synchronized delivery. Med Phys 33(11):4330–4336

    Article  PubMed  Google Scholar 

  33. Zhang T, Keller H, O’Brien MJ, Mackie TR, Paliwal B (2003) Application of the spirometer in respiratory gated radiotherapy. Med Phys 30(12):3165–3171

    Article  PubMed  Google Scholar 

  34. Seppenwoolde Y, Shirato H, Kitamura K, Shimizu S, van Herk M, Lebesque JV, Miyasaka K (2002) Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. Int J Radiat Oncol Biol Phys 53(4):822–834

    Article  PubMed  Google Scholar 

  35. Poulsen PR, Cho B, Sawant A, Ruan D, Keall PJ (2010) Detailed analysis of latencies in image-based dynamic MLC tracking. Med Phys 37(9):4998–5005

    Article  PubMed  Google Scholar 

  36. Keall PJ, Todor AD, Vedam SS, Bartee CL, Siebers JV, Kini VR, Mohan R (2004) On the use of EPID-based implanted marker tracking for 4D radiotherapy. Med Phys 31(12):3492–3499

    Article  PubMed  CAS  Google Scholar 

  37. Xu T, Wong JT, Shikhaliev PM, Ducote JL, Al-Ghazi MS, Molloi S (2006) Real-time tumor tracking using implanted positron emission markers: concept and simulation study. Med Phys 33(7):2598–2609

    Article  PubMed  CAS  Google Scholar 

  38. Cho B, Poulsen PR, Sloutsky A, Sawant A, Keall PJ (2009) First demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking. Int J Radiat Oncol Biol Phys 74(3):859–867

    Article  PubMed  Google Scholar 

  39. Neicu T, Shirato H, Seppenwoolde Y, Jiang SB (2003) Synchronized moving aperture radiation therapy (SMART): average tumour trajectory for lung patients. Phys Med Biol 48:587–598

    Article  PubMed  Google Scholar 

  40. Poulsen PR, Cho B, Ruan D, Sawant A, Keall PJ (2010) Dynamic multileaf collimator tracking of respiratory target motion based on a single kilovoltage imager during arc radiotherapy. Int J Radiat Oncol Biol Phys 77(2):600–607

    Article  PubMed  Google Scholar 

  41. Ren Q, Nishioka S, Shirato H, Berbeco R (2007) Adaptive prediction of respiratory motion for motion compensation radiotherapy. Phys Med Biol 52:6651–6661

    Article  PubMed  Google Scholar 

  42. Bert C, Metheany KG, Doppke K, Chen GTY (2005) A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup. Med Phys 32(9):2753–2762

    Article  PubMed  Google Scholar 

  43. Mah D, Hanley J, Rosenzweig KE, Yorke E, Braban L, Ling CC, Leibel SA, Mageras G (2000) Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer. Int J Radiat Oncol Biol Phys 48(4):1175–1185

    Article  PubMed  CAS  Google Scholar 

  44. Hanley J, Debois MM, Mah D, Mageras GS, Raben A, Rosenzweig K, Mychalczak B, Schwartz LH, Gloeggler PJ, Lutz W, Ling CC, Leibel SA, Fuks Z, Kutcher GJ (1999) Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation. Int J Radiat Oncol Biol Phys 45(3):603–611

    Article  PubMed  CAS  Google Scholar 

  45. Dawson LA, Brock KK, Kazanjian S, Fitch D, McGinn CJ, Lawrence TS, Ten Haken RK, Balter J (2001) The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy. Int J Radiat Oncol Biol Phys 51(5):1410–1421

    Article  PubMed  CAS  Google Scholar 

  46. Keall PJ, Cattell H, Pokhrel D, Dieterich S, Wong KH, Murphy MJ, Vedam SS, Wijesooriya K, Mohan R (2006) Geometric accuracy of a real-time target tracking system with dynamic multileaf collimator tracking system. Int J Radiat Oncol Biol Phys 65(5):1579–1584

    Article  PubMed  Google Scholar 

  47. Cervino L, Gupta S, Rose M, Yashar C, Jiang S (2009) Using surface imaging and visual coaching to improve the reproducibility and stability of deep-inspiration breath hold for left-breast-cancer radiotherapy. Phys Med Biol 54:6853–6865

    Article  PubMed  Google Scholar 

  48. Li G, Arora NC, Xie H, Ning H, Lu W, Low D, Citrin D, Kaushal A, Zach L, Camphausen K, Miller RW (2009) Quantitative prediction of respiratory tidal volume based on the external torso volume change: a potential volumetric surrogate. Phys Med Biol 54:1963–1978

    Article  PubMed  Google Scholar 

  49. Bert C, Metheany KG, Doppke KP, Taghian AG, Powell SN, Chen GTY (2006) Clinical experience with a 3D surface patient setup system for alignment of partial-breast irradiation patients. Int J Radiat Oncol Biol Phys 64(4):1265–1274

    Article  PubMed  Google Scholar 

  50. Park K, Huang L, Gagne H, Papiez L (2009) Do maximum intensity projection images truly capture tumor motion? Int J Radiat Oncol Biol Phys 73(2):618–625

    Article  PubMed  Google Scholar 

  51. Minohara S, Kanai T, Endo M, Noda K, Kanazawa M (2000) Respiratory gated irradiation system for heavy-ion radiotherapy. Int J Radiat Oncol Biol Phys 47(4):1097–1103

    Article  PubMed  CAS  Google Scholar 

  52. Wong JW, Sharpe MB, Jaffray DA, Kini VR, Robertson JM, Stromberg JS, Martinez AA (1999) The use of active breathing control (ABC) to reduce margin for breathing motion. Int J Radiat Oncol Biol Phys 44(4):911–919

    Article  PubMed  CAS  Google Scholar 

  53. Rosenzweig KE, Hanley J, Mah D, Mageras G, Hunt M, Toner S, Burman C, Ling CC, Mychalczak B, Fuks Z, Leibel SA (2000) The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer. Int J Radiat Oncol Biol Phys 48(1):81–87

    Article  PubMed  CAS  Google Scholar 

  54. Ohara K, Okumura T, Akisada M, Inada T, Mori T, Yokota H, Calaguas MJB (1989) Irradiation synchronized with respiration gate. Int J Radiat Oncol Biol Phys 17(4):853–857

    Article  PubMed  CAS  Google Scholar 

  55. Remouchamps VM, Letts N, Vicini FA, Sharpe MB, Kestin LL, Chen PY, Martinez AA, Wong JW (2003) Initial clinical experience with moderate deep-inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy. Int J Radiat Oncol Biol Phys 56(3):704–715

    Article  PubMed  Google Scholar 

  56. Ha J, Perlow D, Yi BY, Yu C (2008) On the sources of drift in a turbine-based spirometer. Phys Med Biol 53:4269–4283

    Article  PubMed  Google Scholar 

  57. Coolens C, Webb S, Shirato H, Nishioka K, Evans P (2008) A margin model to account for respiration-induced tumour motion and its variability. Phys Med Biol 53:4317–4330

    Article  PubMed  Google Scholar 

  58. Mageras GS, Kutcher GJ, Leibel SA, Zelefsky MJ, Melian E, Mohan R, Fuks Z (1996) A method of incorporating organ motion uncertainties into three-dimensional conformal treatment plans. Int J Radiat Oncol Biol Phys 35(2):333–342

    Article  PubMed  CAS  Google Scholar 

  59. Keall PJ, Starkschall G, Shukla H, Forster KM, Ortiz V, Stevens CW, Vedam SS, George R, Guerrero T, Mohan R (2004) Acquiring 4D thoracic CT scans using a multislice helical method. Phys Med Biol 49:2053–2067

    Article  PubMed  CAS  Google Scholar 

  60. Keall PJ, Vedam SS, George R, Williamson JF (2007) Respiratory regularity gated 4D CT acquisition: concepts and proof of principle. Australas Phys Eng Sci Med 30(3):211–220

    Article  PubMed  CAS  Google Scholar 

  61. Shen S, Duan J, Fiveash JB, Brezovich IA, Plant BA, Spencer SA, Popple RA, Pareek PN, Bonner JA (2003) Validation of target volume and position in respiratory gated CT planning and treatment. Med Phys 30(12):3196–3205

    Article  PubMed  Google Scholar 

  62. Barnes EA, Murray BR, Robinson DM, Underwood LJ, Hanson J, Roa WHY (2001) Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration. Int J Radiat Oncol Biol Phys 50(4):1091–1098

    Article  PubMed  CAS  Google Scholar 

  63. Lagerwaard FJ, Van Sornsen de Koste JR, Nijssen-Visser MRJ, Schuchhard-Schipper RH, Oei SS, Munne A, Senan S (2001) Multiple “slow” CT scans for incorporating lung tumor mobility in radiotheraphy planning. Int J Radiat Oncol Biol Phys 51(4):932–937

    Article  PubMed  CAS  Google Scholar 

  64. van Sörnsen de Koste JR, Lagerwaard FJ, de Boer HCJ, Nijssen-Visser MRJ, Senan S (2003) Are multiple CT scans required for planning curative radiotherapy in lung tumors of the lower lobe? Int J Radiat Oncol Biol Phys 55(5):1394–1399

    Article  Google Scholar 

  65. van Sörnsen de Koste JR, Lagerwaard FJ, Schuchhard-Schipper RH, Nijssen-Visser MRJ, Voet PWJ, Oei SS, Senan S (2001) Dosimetric consequences of tumor mobility in radiotherapy of stage I non-small cell lung cancer—an analysis of data generated using [‘]slow’ CT scans. Radiother Oncol 61(1):93–99

    Article  PubMed  Google Scholar 

  66. Sonke J-J, Zijp L, Remeijer P, van Herk M (2005) Respiratory correlated cone beam CT. Med Phys 32(4):1176–1186

    Article  PubMed  Google Scholar 

  67. Shimizu S, Shirato H, Kagei K, Nishioka T, Bo X, Dosaka-Akita H, Hashimoto S, Aoyama H, Tsuchiya K, Miyasaka K (2000) Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy. Int J Radiat Oncol Biol Phys 46(5):1127–1133

    Article  PubMed  CAS  Google Scholar 

  68. Takeda A, Kunieda E, Shigematsu N, Hossain DM, Kawase T, Ohashi T, Fukada J-i, Kawaguchi O, Uematsu M, Takeda T, Takemasa K, Takahashi T, Kubo A (2005) Small lung tumors: long-scan-time ct for planning of hypofractionated stereotactic radiation therapy—initial findings1. Radiology 237(1):295–300

    Article  PubMed  Google Scholar 

  69. Abdelnour AF et al (2007) Phase and amplitude binning for 4D-CT imaging. Phys Med Biol 52(12):3515

    Article  PubMed  CAS  Google Scholar 

  70. Underberg RWM, Lagerwaard FJ, Slotman BJ, Cuijpers JP, Senan S (2005) Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer. Int J Radiat Oncol Biol Phys 63(1):253–260

    Article  PubMed  Google Scholar 

  71. Dieterich L, Jetter S, Tucking T, Nill S, Oelfke U (2006) Linac-integrated 4D cone beam CT: first experimental results. Phys Med Biol 51:2939–2952

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to J. Moorrees.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Moorrees, J., Bezak, E. Four dimensional CT imaging: a review of current technologies and modalities. Australas Phys Eng Sci Med 35, 9–23 (2012). https://doi.org/10.1007/s13246-012-0124-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13246-012-0124-6

Keywords

Navigation