Skip to main content
Top
Published in: Journal of Cardiovascular Magnetic Resonance 1/2018

Open Access 01-12-2018 | Technical notes

Multidimensional fetal flow imaging with cardiovascular magnetic resonance: a feasibility study

Authors: Datta Singh Goolaub, Christopher W. Roy, Eric Schrauben, Dafna Sussman, Davide Marini, Mike Seed, Christopher K. Macgowan

Published in: Journal of Cardiovascular Magnetic Resonance | Issue 1/2018

Login to get access

Abstract

Purpose

To image multidimensional flow in fetuses using golden-angle radial phase contrast cardiovascular magnetic resonance (PC-CMR) with motion correction and retrospective gating.

Methods

A novel PC-CMR method was developed using an ungated golden-angle radial acquisition with continuously incremented velocity encoding. Healthy subjects (n = 5, 27 ± 3 years, males) and pregnant females (n = 5, 34 ± 2 weeks gestation) were imaged at 3 T using the proposed sequence. Real-time reconstructions were first performed for retrospective motion correction and cardiac gating (using metric optimized gating, MOG). CINE reconstructions of multidimensional flow were then performed using the corrected and gated data.

Results

In adults, flows obtained using the proposed method agreed strongly with those obtained using a conventionally gated Cartesian acquisition. Across the five adults, bias and limits of agreement were − 1.0 cm/s and [− 5.1, 3.2] cm/s for mean velocities and − 1.1 cm/s and [− 6.5, 4.3] cm/s for peak velocities. Temporal correlation between corresponding waveforms was also high (R~ 0.98). Calculated timing errors between MOG and pulse-gating RR intervals were low (~ 20 ms). First insights into multidimensional fetal blood flows were achieved. Inter-subject consistency in fetal descending aortic flows (n = 3) was strong with an average velocity of 27.1 ± 0.4 cm/s, peak systolic velocity of 70.0 ± 1.8 cm/s and an intra-class correlation coefficient of 0.95 between the velocity waveforms. In one fetal case, high flow waveform reproducibility was demonstrated in the ascending aorta (R = 0.97) and main pulmonary artery (R = 0.99).

Conclusion

Multidimensional PC-CMR of fetal flow was developed and validated, incorporating retrospective motion compensation and cardiac gating. Using this method, the first quantification and visualization of multidimensional fetal blood flow was achieved using CMR.
Appendix
Available only for authorised users
Literature
1.
go back to reference Sun L, Macgowan CK, Sled JG, Yoo S-J, Manlhiot C, Porayette P, Grosse-Wortmann L, Jaeggi E, McCrindle BW, Hickey E, et al. Reduced fetal cerebral oxygen consumption is associated with smaller brain size in fetuses with congenital heart disease. Circulation. 2015;137(10):1313–23.CrossRef Sun L, Macgowan CK, Sled JG, Yoo S-J, Manlhiot C, Porayette P, Grosse-Wortmann L, Jaeggi E, McCrindle BW, Hickey E, et al. Reduced fetal cerebral oxygen consumption is associated with smaller brain size in fetuses with congenital heart disease. Circulation. 2015;137(10):1313–23.CrossRef
2.
go back to reference Arduini D, Rizzo G, Romanini C, Mancuso S. Fetal haemodynamic response to acute maternal hyperoxygenation as predictor of fetal distress in intrauterine growth retardation. BMJ. 1989;298(6687):1561.CrossRef Arduini D, Rizzo G, Romanini C, Mancuso S. Fetal haemodynamic response to acute maternal hyperoxygenation as predictor of fetal distress in intrauterine growth retardation. BMJ. 1989;298(6687):1561.CrossRef
3.
go back to reference Strasburger JF, Wakai RT. Fetal cardiac arrhythmia detection and in utero therapy. Nat Rev Cardiol. 2010;7(5):277.CrossRef Strasburger JF, Wakai RT. Fetal cardiac arrhythmia detection and in utero therapy. Nat Rev Cardiol. 2010;7(5):277.CrossRef
4.
go back to reference Freud LR, McElhinney DB, Marshall AC, Marx GR, Friedman KG, Pedro J, Emani SM, Lafranchi T, Silva V, Wilkins-Haug LE, et al. Fetal aortic valvuloplasty for evolving hypoplastic left heart syndrome: postnatal outcomes of the first 100 patients. Circulation. 2014;130(8):638–45.CrossRef Freud LR, McElhinney DB, Marshall AC, Marx GR, Friedman KG, Pedro J, Emani SM, Lafranchi T, Silva V, Wilkins-Haug LE, et al. Fetal aortic valvuloplasty for evolving hypoplastic left heart syndrome: postnatal outcomes of the first 100 patients. Circulation. 2014;130(8):638–45.CrossRef
5.
go back to reference Porayette P, van Amerom JF, Yoo S-J, Jaeggi E, Macgowan CK, Seed M. Mri shows limited mixing between systemic and pulmonary circulations in foetal transposition of the great arteries: a potential cause of in utero pulmonary vascular disease. Cardiol Young. 2015;25(4):737–44.CrossRef Porayette P, van Amerom JF, Yoo S-J, Jaeggi E, Macgowan CK, Seed M. Mri shows limited mixing between systemic and pulmonary circulations in foetal transposition of the great arteries: a potential cause of in utero pulmonary vascular disease. Cardiol Young. 2015;25(4):737–44.CrossRef
6.
go back to reference Al Nafisi B, van Amerom JF, Forsey J, Jaeggi E, Grosse-Wortmann L, Yoo S-J, Macgowan CK, Seed M. Fetal circulation in left-sided congenital heart disease measured by cardiovascular magnetic resonance: a case–control study. J Cardiovasc Magn Reson. 2013;15(1):65.CrossRef Al Nafisi B, van Amerom JF, Forsey J, Jaeggi E, Grosse-Wortmann L, Yoo S-J, Macgowan CK, Seed M. Fetal circulation in left-sided congenital heart disease measured by cardiovascular magnetic resonance: a case–control study. J Cardiovasc Magn Reson. 2013;15(1):65.CrossRef
7.
go back to reference Bammer R, Hope TA, Aksoy M, Alley MT. Time-resolved 3d quantitative flow mri of the major intracranial vessels: initial experience and comparative evaluation at 1.5 t and 3.0 t in combination with parallel imaging. Magn Reson Med. 2007;57(1):127–40.CrossRef Bammer R, Hope TA, Aksoy M, Alley MT. Time-resolved 3d quantitative flow mri of the major intracranial vessels: initial experience and comparative evaluation at 1.5 t and 3.0 t in combination with parallel imaging. Magn Reson Med. 2007;57(1):127–40.CrossRef
8.
go back to reference Sameni R, Clifford GD. A review of fetal ecg signal processing; issues and promising directions. The open pacing, electrophysiology & therapy journal. 2010;3:4. Sameni R, Clifford GD. A review of fetal ecg signal processing; issues and promising directions. The open pacing, electrophysiology & therapy journal. 2010;3:4.
9.
go back to reference Seed M, van Amerom JF, Yoo S-J, Al Nafisi B, Grosse-Wortmann L, Jaeggi E, Jansz MS, Macgowan CK. Feasibility of quantification of the distribution of blood flow in the normal human fetal circulation using cmr: a cross-sectional study. J Cardiovasc Magn Reson. 2012;14(1):1.CrossRef Seed M, van Amerom JF, Yoo S-J, Al Nafisi B, Grosse-Wortmann L, Jaeggi E, Jansz MS, Macgowan CK. Feasibility of quantification of the distribution of blood flow in the normal human fetal circulation using cmr: a cross-sectional study. J Cardiovasc Magn Reson. 2012;14(1):1.CrossRef
10.
go back to reference Prsa M, Sun L, van Amerom J, Yoo S-J, Grosse-Wortmann L, Jaeggi E, Macgowan C, Seed M. Reference ranges of blood flow in the major vessels of the normal human fetal circulation at term by phase-contrast magnetic resonance imagingclinical perspective. Circ Cardiovasc Imaging. 2014;7(4):663–70.CrossRef Prsa M, Sun L, van Amerom J, Yoo S-J, Grosse-Wortmann L, Jaeggi E, Macgowan C, Seed M. Reference ranges of blood flow in the major vessels of the normal human fetal circulation at term by phase-contrast magnetic resonance imagingclinical perspective. Circ Cardiovasc Imaging. 2014;7(4):663–70.CrossRef
11.
go back to reference Roy C, Seed M, Macgowan C. Accelerated phase contrast measurements of fetal blood flow using compressed sensing. J Cardiovasc Magn Reson. 2016;18(1):P30.CrossRef Roy C, Seed M, Macgowan C. Accelerated phase contrast measurements of fetal blood flow using compressed sensing. J Cardiovasc Magn Reson. 2016;18(1):P30.CrossRef
12.
go back to reference Roy CW, Seed M, Macgowan CK, et al. Motion compensated cine cmr of the fetal heart using radial undersampling and compressed sensing. J Cardiovasc Magn Reson. 2017;19(1):29.CrossRef Roy CW, Seed M, Macgowan CK, et al. Motion compensated cine cmr of the fetal heart using radial undersampling and compressed sensing. J Cardiovasc Magn Reson. 2017;19(1):29.CrossRef
13.
go back to reference Chaptinel J, Yerly J, Mivelaz Y, Prsa M, Alamo L, Vial Y, Berchier G, Rohner C, Gudinchet F, Stuber M. Fetal cardiac cine magnetic resonance imaging in utero. Sci Rep. 2017;7(1):15540.CrossRef Chaptinel J, Yerly J, Mivelaz Y, Prsa M, Alamo L, Vial Y, Berchier G, Rohner C, Gudinchet F, Stuber M. Fetal cardiac cine magnetic resonance imaging in utero. Sci Rep. 2017;7(1):15540.CrossRef
14.
go back to reference Feng L, Grimm R, Block KT, Chandarana H, Kim S, Xu J, Axel L, Sodickson DK, Otazo R. Golden-angle radial sparse parallel mri: combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric mri. Magn Reson Med. 2014;72(3):707–17.CrossRef Feng L, Grimm R, Block KT, Chandarana H, Kim S, Xu J, Axel L, Sodickson DK, Otazo R. Golden-angle radial sparse parallel mri: combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric mri. Magn Reson Med. 2014;72(3):707–17.CrossRef
15.
go back to reference Lustig M, Donoho D, Pauly JM. Sparse mri: the application of compressed sensing for rapid mr imaging. Magn Reson Med. 2007;58(6):1182–95.CrossRef Lustig M, Donoho D, Pauly JM. Sparse mri: the application of compressed sensing for rapid mr imaging. Magn Reson Med. 2007;58(6):1182–95.CrossRef
16.
go back to reference Otazo R, Candes E, Sodickson DK. Low-rank plus sparse matrix decomposition for accelerated dynamic mri with separation of background and dynamic components. Magn Reson Med. 2015;73(3):1125–36.CrossRef Otazo R, Candes E, Sodickson DK. Low-rank plus sparse matrix decomposition for accelerated dynamic mri with separation of background and dynamic components. Magn Reson Med. 2015;73(3):1125–36.CrossRef
17.
go back to reference Roy CW, Seed M, Macgowan CK. Accelerated mri of the fetal heart using compressed sensing and metric optimized gating. Magn Reson Med. 2017;77(6):2125–35.CrossRef Roy CW, Seed M, Macgowan CK. Accelerated mri of the fetal heart using compressed sensing and metric optimized gating. Magn Reson Med. 2017;77(6):2125–35.CrossRef
18.
go back to reference Otazo R, Kim D, Axel L, Sodickson DK. Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion mri. Magn Reson Med. 2010;64(3):767–76.CrossRef Otazo R, Kim D, Axel L, Sodickson DK. Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion mri. Magn Reson Med. 2010;64(3):767–76.CrossRef
19.
go back to reference Kwak Y, Nam S, Akçakaya M, Basha TA, Goddu B, Manning WJ, Tarokh V, Nezafat R. Accelerated aortic flow assessment with compressed sensing with and without use of the sparsity of the complex difference image. Magn Reson Med. 2013;70(3):851–8.CrossRef Kwak Y, Nam S, Akçakaya M, Basha TA, Goddu B, Manning WJ, Tarokh V, Nezafat R. Accelerated aortic flow assessment with compressed sensing with and without use of the sparsity of the complex difference image. Magn Reson Med. 2013;70(3):851–8.CrossRef
20.
go back to reference Knoll F, Schwarzl A, Diwoky C, Sodickson DK. Gpunufft-an open source gpu library for 3d regridding with direct matlab interface. In: Proceedings of the 22nd annual meeting of ISMRM, Milan, Italy; 2014. p. 4297. Knoll F, Schwarzl A, Diwoky C, Sodickson DK. Gpunufft-an open source gpu library for 3d regridding with direct matlab interface. In: Proceedings of the 22nd annual meeting of ISMRM, Milan, Italy; 2014. p. 4297.
21.
go back to reference Klein S, Staring M, Murphy K, Viergever MA, Pluim JP. Elastix: a toolbox for intensity-based medical image registration. IEEE Trans Med Imaging. 2010;29(1):196–205.CrossRef Klein S, Staring M, Murphy K, Viergever MA, Pluim JP. Elastix: a toolbox for intensity-based medical image registration. IEEE Trans Med Imaging. 2010;29(1):196–205.CrossRef
22.
go back to reference Walker PG, Cranney GB, Scheidegger MB, Waseleski G, Pohost GM, Yoganathan AP. Semiautomated method for noise reduction and background phase error correction in mr phase velocity data. J Magn Reson Imaging. 1993;3(3):521–30.CrossRef Walker PG, Cranney GB, Scheidegger MB, Waseleski G, Pohost GM, Yoganathan AP. Semiautomated method for noise reduction and background phase error correction in mr phase velocity data. J Magn Reson Imaging. 1993;3(3):521–30.CrossRef
23.
go back to reference Fadnes S, Nyrnes SA, Wigen M, Tegnander E, Lovstakken L. Detailed flow visualization in fetal and neonatal hearts using 2-d speckle tracking. In: Ultrasonics Symposium (IUS), 2016 IEEE International. Tours: IEEE; 2016. p. 1–4. Fadnes S, Nyrnes SA, Wigen M, Tegnander E, Lovstakken L. Detailed flow visualization in fetal and neonatal hearts using 2-d speckle tracking. In: Ultrasonics Symposium (IUS), 2016 IEEE International. Tours: IEEE; 2016. p. 1–4.
24.
go back to reference Hope TA, Markl M, Wigström L, Alley MT, Miller DC, Herfkens RJ. Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping. J Magn Reson Imaging. 2007;26(6):1471–9.CrossRef Hope TA, Markl M, Wigström L, Alley MT, Miller DC, Herfkens RJ. Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping. J Magn Reson Imaging. 2007;26(6):1471–9.CrossRef
25.
go back to reference Konje JC, Abrams KR, Taylor DJ. Normative values of doppler velocimetry of five major fetal arteries as determined by color power angiography. Acta Obstet Gynecol Scand. 2005;84(3):230–7.CrossRef Konje JC, Abrams KR, Taylor DJ. Normative values of doppler velocimetry of five major fetal arteries as determined by color power angiography. Acta Obstet Gynecol Scand. 2005;84(3):230–7.CrossRef
26.
go back to reference Guan Y, Li S, Luo G, Wang C, Norwitz ER, Fu Q, Tu X, Tian X, Zhu J. The role of doppler waveforms in the fetal main pulmonary artery in the prediction of neonatal respiratory distress syndrome. J Clin Ultrasound. 2015;43(6):375–83.CrossRef Guan Y, Li S, Luo G, Wang C, Norwitz ER, Fu Q, Tu X, Tian X, Zhu J. The role of doppler waveforms in the fetal main pulmonary artery in the prediction of neonatal respiratory distress syndrome. J Clin Ultrasound. 2015;43(6):375–83.CrossRef
27.
go back to reference Portnoy S, Seed M, Sled JG, Macgowan CK. Non-invasive evaluation of blood oxygen saturation and hematocrit from t1 and t2 relaxation times: in-vitro validation in fetal blood. Magn Reson Med. 2017;78(6):2352–9.CrossRef Portnoy S, Seed M, Sled JG, Macgowan CK. Non-invasive evaluation of blood oxygen saturation and hematocrit from t1 and t2 relaxation times: in-vitro validation in fetal blood. Magn Reson Med. 2017;78(6):2352–9.CrossRef
28.
go back to reference Yamamura J, Frisch M, Ecker H, Graessner J, Hecher K, Adam G, Wedegärtner U. Self-gating mr imaging of the fetal heart: comparison with real cardiac triggering. Eur Radiol. 2011;21(1):142–9.CrossRef Yamamura J, Frisch M, Ecker H, Graessner J, Hecher K, Adam G, Wedegärtner U. Self-gating mr imaging of the fetal heart: comparison with real cardiac triggering. Eur Radiol. 2011;21(1):142–9.CrossRef
29.
go back to reference Haris K, Hedström E, Bidhult S, Testud F, Maglaveras N, Heiberg E, Hansson SR, Arheden H, Aletras AH. Self-gated fetal cardiac mri with tiny golden angle igrasp: a feasibility study. J Magn Reson Imaging. 2017;46(1):207–17.CrossRef Haris K, Hedström E, Bidhult S, Testud F, Maglaveras N, Heiberg E, Hansson SR, Arheden H, Aletras AH. Self-gated fetal cardiac mri with tiny golden angle igrasp: a feasibility study. J Magn Reson Imaging. 2017;46(1):207–17.CrossRef
30.
go back to reference van Amerom JF, Lloyd DF, Price AN, Kuklisova Murgasova M, Aljabar P, Malik SJ, Lohezic M, Rutherford MA, Pushparajah K, Razavi R, et al. Fetal cardiac cine imaging using highly accelerated dynamic mri with retrospective motion correction and outlier rejection. Magn Reson Med. 2018;79(1):327–38.CrossRef van Amerom JF, Lloyd DF, Price AN, Kuklisova Murgasova M, Aljabar P, Malik SJ, Lohezic M, Rutherford MA, Pushparajah K, Razavi R, et al. Fetal cardiac cine imaging using highly accelerated dynamic mri with retrospective motion correction and outlier rejection. Magn Reson Med. 2018;79(1):327–38.CrossRef
31.
go back to reference Kording F, Yamamura J, De Sousa MT, Ruprecht C, Hedström E, Aletras AH, Grant PE, Powell AJ, Fehrs K, Adam G, et al. Dynamic fetal cardiovascular magnetic resonance imaging using doppler ultrasound gating. J Cardiovasc Magn Reson. 2018;20(1):17.CrossRef Kording F, Yamamura J, De Sousa MT, Ruprecht C, Hedström E, Aletras AH, Grant PE, Powell AJ, Fehrs K, Adam G, et al. Dynamic fetal cardiovascular magnetic resonance imaging using doppler ultrasound gating. J Cardiovasc Magn Reson. 2018;20(1):17.CrossRef
32.
go back to reference Demesmaeker R, Kober T, Yerly J, Chaptinel J, Prsa M, Mivelaz Y, Alamo L, Vial Y, Berchier G, Rohner C, et al. Automated heartbeat detection for self-gated fetal cardiac mri. Proc Int Soc Magn Reson Med; Honolulu, HI, USA. 2017. Abstract No 0633. Demesmaeker R, Kober T, Yerly J, Chaptinel J, Prsa M, Mivelaz Y, Alamo L, Vial Y, Berchier G, Rohner C, et al. Automated heartbeat detection for self-gated fetal cardiac mri. Proc Int Soc Magn Reson Med; Honolulu, HI, USA. 2017. Abstract No 0633.
33.
go back to reference Steeden JA, Atkinson D, Taylor AM, Muthurangu V. Rapid flow assessment of congenital heart disease using high spatio-temporal gated spiral phase-contrast mr. J Cardiovasc Magnetic Reson. 2011;13(S1):P380.CrossRef Steeden JA, Atkinson D, Taylor AM, Muthurangu V. Rapid flow assessment of congenital heart disease using high spatio-temporal gated spiral phase-contrast mr. J Cardiovasc Magnetic Reson. 2011;13(S1):P380.CrossRef
Metadata
Title
Multidimensional fetal flow imaging with cardiovascular magnetic resonance: a feasibility study
Authors
Datta Singh Goolaub
Christopher W. Roy
Eric Schrauben
Dafna Sussman
Davide Marini
Mike Seed
Christopher K. Macgowan
Publication date
01-12-2018
Publisher
BioMed Central
Published in
Journal of Cardiovascular Magnetic Resonance / Issue 1/2018
Electronic ISSN: 1532-429X
DOI
https://doi.org/10.1186/s12968-018-0498-z

Other articles of this Issue 1/2018

Journal of Cardiovascular Magnetic Resonance 1/2018 Go to the issue