An innovative total temporomandibular joint prosthesis with customized design and 3D printing additive fabrication: a prospective clinical study

Authors: JiSi Zheng, XuZhuo Chen, WenBo Jiang, ShanYong Zhang, MinJie Chen, Chi Yang

Published in: Journal of Translational Medicine | Issue 1/2019

Login to get access

Abstract

Background

Total temporomandibular joint (TMJ) prosthesis is an effective and reliable method of joint reconstruction. However, there is still an urgent need to design a new TMJ prosthesis because of no commercially available TMJ prosthesis appropriate for the clinical application on the Chinese population. This study was introduced to prospectively confirm the safety and effectiveness of a new TMJ prosthesis with customized design and 3D printing additive fabrication in clinical application.

Methods

Patients with unilateral end-stage TMJ osteoarthrosis were recruited in this study from Nov 2016 to Mar 2017. Computed tomography scans for all patients were obtained and transformed into three-dimensional (3D) reconstruction models. The customized TMJ prosthesis consisted of three components including the fossa, condylar head, and mandibular handle units, which were designed based on the anatomy of the TMJ and were fabricated using the 3D printing technology. The prominent characters of the prosthesis were the customized design of the fossa component with a single ultra-high-molecular-weight polyethylene and the connection mechanism between the condylar head (Co–Cr–Mo alloy) and mandibular handle components (Ti6Al4 V alloy). The clinical follow-up, radiographic evaluation and laboratory indices were all done to analyze the prosthesis’ outcomes in the clinical application.

Results

12 consecutive patients were included in the study. There were no complications (infection of the surgical wound, damage of liver and kidney, displacement, breakage, or loosening of the prosthesis) found after surgery. Pain, diet, mandibular function, and maximal interincisal opening showed significant improvements after surgery. But the lateral movement was limited to the non-operated side and the mandible deviated towards the operated side on opening mouth following surgery.

Conclusions

The presented TMJ prosthesis is considered an innovative product in TMJ Yang’s system, which is unique compared to other prostheses for the special design and 3D printing additive manufacture. Moreover, the prosthesis is very safe and efficient for clinical use.
Trial registration Prospective reports on Chinese customized total temporomandibular joint prosthesis reconstruction cases, ChiCTR-ONC-16009712. Registered 22 Nov 2016, http://​www.​chictr.​org.​cn/​showproj.​aspx?​proj=​16091
Literature
1.
go back to reference Singh RK. Temporomandibular joint disorders. Natl J Maxillofac Surg. 2016;7(1):1–2.CrossRef Singh RK. Temporomandibular joint disorders. Natl J Maxillofac Surg. 2016;7(1):1–2.CrossRef
2.
go back to reference McNeill C, Mohl ND, Rugh JD, Tanaka TT. Temporomandibular disorders: diagnosis, management, education, and research. J Am Dent Assoc. 1990;120(3):253–7.CrossRef McNeill C, Mohl ND, Rugh JD, Tanaka TT. Temporomandibular disorders: diagnosis, management, education, and research. J Am Dent Assoc. 1990;120(3):253–7.CrossRef
3.
go back to reference Mercuri LG. Temporomandibular joint total joint replacement-TMJ TJR—a comprehensive reference for researchers, material scientists and surgeons. New York: Springer International Publishing; 2016.CrossRef Mercuri LG. Temporomandibular joint total joint replacement-TMJ TJR—a comprehensive reference for researchers, material scientists and surgeons. New York: Springer International Publishing; 2016.CrossRef
4.
go back to reference Katsnelson A, Markiewicz MR, Keith DA. Operative management of temporomandibular joint ankylosis: a systematic reviewed meta-analysis. J Oral Maxillofac Surg. 2012;70(3):531–6.CrossRef Katsnelson A, Markiewicz MR, Keith DA. Operative management of temporomandibular joint ankylosis: a systematic reviewed meta-analysis. J Oral Maxillofac Surg. 2012;70(3):531–6.CrossRef
5.
go back to reference Kurtoglu C, Kurkcu M, Sertdemir Y, Ozbek S, Gürbüz CC. Temporomandibular disorders in patients with rheumatoid arthritis: a clinical study. Niger J Clin Pract. 2016;19(6):715–20.CrossRef Kurtoglu C, Kurkcu M, Sertdemir Y, Ozbek S, Gürbüz CC. Temporomandibular disorders in patients with rheumatoid arthritis: a clinical study. Niger J Clin Pract. 2016;19(6):715–20.CrossRef
6.
go back to reference Charnley J. Arthroplasty of the hip. A new operation. Lancet. 1961;1(7187):1129–32.CrossRef Charnley J. Arthroplasty of the hip. A new operation. Lancet. 1961;1(7187):1129–32.CrossRef
7.
go back to reference Healy WL, Iorio R, Lemos MJ. Athletic activity after joint replacement. Am J Sports Med. 2001;29(3):377–88.CrossRef Healy WL, Iorio R, Lemos MJ. Athletic activity after joint replacement. Am J Sports Med. 2001;29(3):377–88.CrossRef
8.
go back to reference Zwetyenga N, Amroun S, Wajszczak BL, Moris V. Total temporomandibular joint prostheses. Rev Stomatol Chir Maxillofac Chir Orale. 2016;117(4):285–93.PubMed Zwetyenga N, Amroun S, Wajszczak BL, Moris V. Total temporomandibular joint prostheses. Rev Stomatol Chir Maxillofac Chir Orale. 2016;117(4):285–93.PubMed
9.
go back to reference Driemel O, Braun S, Müller-Richter UD, Behr M, Reichert TE, Kunkel M, Reich R. Historical development of alloplastic temporomandibular joint replacement after 1945 and state of the art. Int J Oral Maxillofac Surg. 2009;38(9):909–20.CrossRef Driemel O, Braun S, Müller-Richter UD, Behr M, Reichert TE, Kunkel M, Reich R. Historical development of alloplastic temporomandibular joint replacement after 1945 and state of the art. Int J Oral Maxillofac Surg. 2009;38(9):909–20.CrossRef
10.
go back to reference Westermark A. Total reconstruction of the temporomandibular joint. Up to 8 years of follow-up of patients treated with Biomet (®) total joint prosthesis. Int J Oral Maxillofac Surg. 2010;39(10):951–5.CrossRef Westermark A. Total reconstruction of the temporomandibular joint. Up to 8 years of follow-up of patients treated with Biomet (®) total joint prosthesis. Int J Oral Maxillofac Surg. 2010;39(10):951–5.CrossRef
11.
go back to reference Wolford LM, Mercuri LG, Schneiderman ED, Movahed R, Allen W. Twenty-year follow-up study on a patient-fitted temporomandibular joint prosthesis: the Techmedica/TMJ concepts device. J Oral Maxillofac Surg. 2015;73(5):952–60.CrossRef Wolford LM, Mercuri LG, Schneiderman ED, Movahed R, Allen W. Twenty-year follow-up study on a patient-fitted temporomandibular joint prosthesis: the Techmedica/TMJ concepts device. J Oral Maxillofac Surg. 2015;73(5):952–60.CrossRef
12.
go back to reference Mercuri LG. Alloplastic TMJ replacement. Rationale for custom devices. Int J Oral Maxillofac Surg. 2012;41(1):1033–40.CrossRef Mercuri LG. Alloplastic TMJ replacement. Rationale for custom devices. Int J Oral Maxillofac Surg. 2012;41(1):1033–40.CrossRef
13.
go back to reference ShanYong Z, Liu H, Yang C, Zhang X, Abdelrehem A, Zheng J, Jiao Z, Chen M, Qiu Y. Modified surgical techniques for total alloplastic temporomandibular joint replacement: one institution’s experience. J Craniomaxillofac Surg. 2015;43(6):934–9.CrossRef ShanYong Z, Liu H, Yang C, Zhang X, Abdelrehem A, Zheng J, Jiao Z, Chen M, Qiu Y. Modified surgical techniques for total alloplastic temporomandibular joint replacement: one institution’s experience. J Craniomaxillofac Surg. 2015;43(6):934–9.CrossRef
14.
go back to reference Bai G, He D, Yang C, Chen M, Yuan J, Wilson JJ. Application of digital templates to guide total alloplastic joint replacement surgery with Biomet standard replacement system. J Oral Maxillofac Surg. 2014;72(12):2440–52.CrossRef Bai G, He D, Yang C, Chen M, Yuan J, Wilson JJ. Application of digital templates to guide total alloplastic joint replacement surgery with Biomet standard replacement system. J Oral Maxillofac Surg. 2014;72(12):2440–52.CrossRef
15.
go back to reference Lee WY, Park YW, Kim SG. Comparison of costochondral graft and customized total joint reconstruction for treatments of temporomandibular joint replacement. Maxillofac Plast Reconstr Surg. 2014;36(4):135–9.CrossRef Lee WY, Park YW, Kim SG. Comparison of costochondral graft and customized total joint reconstruction for treatments of temporomandibular joint replacement. Maxillofac Plast Reconstr Surg. 2014;36(4):135–9.CrossRef
16.
go back to reference Zhang XH, Yang C, Fang B, Chen MJ, Wu Y, Wang BL. Simultaneous costochondral graft and distraction osteogenesis in unilateral TMJ ankylosis associated with mandibular retrognathia and asymmetry. J Craniofac Surg. 2012;23(3):682–4.CrossRef Zhang XH, Yang C, Fang B, Chen MJ, Wu Y, Wang BL. Simultaneous costochondral graft and distraction osteogenesis in unilateral TMJ ankylosis associated with mandibular retrognathia and asymmetry. J Craniofac Surg. 2012;23(3):682–4.CrossRef
17.
go back to reference Chen M, Yang C, Qiu Y, He D, Huang D, Wei W. Superior half of the sternoclavicular joint pedicled with the sternocleidomastoid muscle for reconstruction of the temporomandibular joint: a preliminary study with a simplified technique and expanded indications. Int J Oral Maxillofac Surg. 2015;44(6):685–91.CrossRef Chen M, Yang C, Qiu Y, He D, Huang D, Wei W. Superior half of the sternoclavicular joint pedicled with the sternocleidomastoid muscle for reconstruction of the temporomandibular joint: a preliminary study with a simplified technique and expanded indications. Int J Oral Maxillofac Surg. 2015;44(6):685–91.CrossRef
18.
go back to reference Chen X, Wang Y, Mao Y, Zhou Z, Zheng J, Zhen J, Qiu Y, Zhang S, Qin H, Yang C. Biomechanical evaluation of Chinese customized three-dimensionally printed total temporomandibular joint prostheses: a finite element analysis. J Craniomaxillofac Surg. 2018;46(9):1561–8.CrossRef Chen X, Wang Y, Mao Y, Zhou Z, Zheng J, Zhen J, Qiu Y, Zhang S, Qin H, Yang C. Biomechanical evaluation of Chinese customized three-dimensionally printed total temporomandibular joint prostheses: a finite element analysis. J Craniomaxillofac Surg. 2018;46(9):1561–8.CrossRef
19.
go back to reference Shen P, Zhang SY, Yang C, Yun B. Stability study of total temporomandibular joint replacement on sheep. J Craniomaxillofac Surg. 2014;42(7):1265–70.CrossRef Shen P, Zhang SY, Yang C, Yun B. Stability study of total temporomandibular joint replacement on sheep. J Craniomaxillofac Surg. 2014;42(7):1265–70.CrossRef
20.
go back to reference Shen P, Zhang S, Yang C, Huang D. The mandibular symmetry evaluation of total temporomandibular joint replacement on developing sheep. J Craniomaxillofac Surg. 2014;42(3):201–5.CrossRef Shen P, Zhang S, Yang C, Huang D. The mandibular symmetry evaluation of total temporomandibular joint replacement on developing sheep. J Craniomaxillofac Surg. 2014;42(3):201–5.CrossRef
21.
go back to reference Wilkes CH. Internal derangements of the temporomandibular joint: pathological variations. Arch Otolargynol head Neck Surg. 1989;115(4):469–77.CrossRef Wilkes CH. Internal derangements of the temporomandibular joint: pathological variations. Arch Otolargynol head Neck Surg. 1989;115(4):469–77.CrossRef
22.
go back to reference Mercuri LG, Wolford LM, Sanders B, White RD, Hurder A, Henderson W. Custom CAD/CAM total temporomandibular joint reconstruction system: preliminary multicenter report. J Oral Maxillofac Surg. 1995;53(2):106–15.CrossRef Mercuri LG, Wolford LM, Sanders B, White RD, Hurder A, Henderson W. Custom CAD/CAM total temporomandibular joint reconstruction system: preliminary multicenter report. J Oral Maxillofac Surg. 1995;53(2):106–15.CrossRef
23.
go back to reference Wolford LM, Pitta MC, Reiche-Fischel O, Franco PF. TMJ Concepts/Techmedica custom-made TMJ total joint prosthesis: 5-year follow-up study. Int J Oral Maxillofac Surg. 2003;32(3):268–74.CrossRef Wolford LM, Pitta MC, Reiche-Fischel O, Franco PF. TMJ Concepts/Techmedica custom-made TMJ total joint prosthesis: 5-year follow-up study. Int J Oral Maxillofac Surg. 2003;32(3):268–74.CrossRef
24.
go back to reference Giannakopoulos HE, Sinn DP, Quinn PD. Biomet microfixation T Temporomandibular joint replacement system: a 3-year follow-up study of patients treated during 1995 to 2005. J Oral Maxillofac Surg. 2012;70(4):787–94.CrossRef Giannakopoulos HE, Sinn DP, Quinn PD. Biomet microfixation T Temporomandibular joint replacement system: a 3-year follow-up study of patients treated during 1995 to 2005. J Oral Maxillofac Surg. 2012;70(4):787–94.CrossRef
25.
go back to reference Zhang LZ, Meng SS, He DM, Fu YZ, Liu T, Wang FY, Dong MJ, Chang YS. Three-dimensional measurement and cluster analysis for determining the size ranges of Chinese temporomandibular joint replacement prosthesis. Medicine. 2016;95(8):e2897.CrossRef Zhang LZ, Meng SS, He DM, Fu YZ, Liu T, Wang FY, Dong MJ, Chang YS. Three-dimensional measurement and cluster analysis for determining the size ranges of Chinese temporomandibular joint replacement prosthesis. Medicine. 2016;95(8):e2897.CrossRef
26.
go back to reference Macedo JP, Pereira J, Vahey BR, Henriques B, Benfatti CA, Magini RS, López-López J, Souza JC. Morse taper dental implants and platform switching: the new paradigm in oral implantology. Eur J Dent. 2016;10(1):148–54.CrossRef Macedo JP, Pereira J, Vahey BR, Henriques B, Benfatti CA, Magini RS, López-López J, Souza JC. Morse taper dental implants and platform switching: the new paradigm in oral implantology. Eur J Dent. 2016;10(1):148–54.CrossRef
27.
go back to reference Schramm M, Wirtz DC, Holzwarth U, Pitto RP. The Morse taper junction in modular revision hip replacement—a biomechanical and retrieval analysis. Biomed Tech. 2000;45(4):105–9.CrossRef Schramm M, Wirtz DC, Holzwarth U, Pitto RP. The Morse taper junction in modular revision hip replacement—a biomechanical and retrieval analysis. Biomed Tech. 2000;45(4):105–9.CrossRef
28.
go back to reference Wolford LM, Karras SC. Autologous fat transplantation around TMJ total joint prostheses. J Oral Maxillofac Surg. 1997;55(3):245–51.CrossRef Wolford LM, Karras SC. Autologous fat transplantation around TMJ total joint prostheses. J Oral Maxillofac Surg. 1997;55(3):245–51.CrossRef
29.
go back to reference Mercuri LG, Alcheikh Ali F, Woolson R. Outcomes of total alloplastic replacement with peri-articular autogenous fat grafting for management of re-ankylosis of the TMJ. J Oral Maxillofac Surg. 2008;66(9):1794–803.CrossRef Mercuri LG, Alcheikh Ali F, Woolson R. Outcomes of total alloplastic replacement with peri-articular autogenous fat grafting for management of re-ankylosis of the TMJ. J Oral Maxillofac Surg. 2008;66(9):1794–803.CrossRef
30.
go back to reference Wyatt MC. Custom 3D-printed acetabular implants in hip surgery—innovative breakthrough or expensive bespoke upgrade? Hip Int. 2015;25(4):375–9.CrossRef Wyatt MC. Custom 3D-printed acetabular implants in hip surgery—innovative breakthrough or expensive bespoke upgrade? Hip Int. 2015;25(4):375–9.CrossRef
31.
go back to reference Ackland DC, Robinson D, Redhead M, Lee PVS, Moskaljuk A, Dimitroulis G. A personalized 3D-printed prosthetic joint replacement for the human temporomandibular joint: from implant design to implantation. J Mech Behav Biomed Mater. 2017;69:404–11.CrossRef Ackland DC, Robinson D, Redhead M, Lee PVS, Moskaljuk A, Dimitroulis G. A personalized 3D-printed prosthetic joint replacement for the human temporomandibular joint: from implant design to implantation. J Mech Behav Biomed Mater. 2017;69:404–11.CrossRef
32.
go back to reference Dimitroulis G, Austin S, Sin Lee PV, Ackland D. A new three-dimensional, print-on demand temporomandibular prosthetic total joint replacement system: preliminary outcomes. J Craniomaxillofac Surg. 2018;46(8):1192–8.CrossRef Dimitroulis G, Austin S, Sin Lee PV, Ackland D. A new three-dimensional, print-on demand temporomandibular prosthetic total joint replacement system: preliminary outcomes. J Craniomaxillofac Surg. 2018;46(8):1192–8.CrossRef
33.
go back to reference Mercuri LG, Wolford LM, Sanders B, White RD, Giobbie-Hurder A. Long-term follow-up of the CAD/CAM patient fitted total temporomandibular joint reconstruction system. J Oral Maxillofac Surg. 2002;60(12):1440–8.CrossRef Mercuri LG, Wolford LM, Sanders B, White RD, Giobbie-Hurder A. Long-term follow-up of the CAD/CAM patient fitted total temporomandibular joint reconstruction system. J Oral Maxillofac Surg. 2002;60(12):1440–8.CrossRef
34.
go back to reference Wolford LM, Mehra P. Custom-made total joint prostheses for temporomandibular joint reconstruction. Proc Bayl Univ Med Cent. 2000;13(2):135–8.CrossRef Wolford LM, Mehra P. Custom-made total joint prostheses for temporomandibular joint reconstruction. Proc Bayl Univ Med Cent. 2000;13(2):135–8.CrossRef
35.
go back to reference Mercuri LG, Miloro M, Skipor AK, Bijukumar D, Sukotjo C, Mathew MT. Serum metal levels in maxillofacial reconstructive surgery patients: a pilot study. J Oral Maxillofac Surg. 2018;76(10):2074–80.CrossRef Mercuri LG, Miloro M, Skipor AK, Bijukumar D, Sukotjo C, Mathew MT. Serum metal levels in maxillofacial reconstructive surgery patients: a pilot study. J Oral Maxillofac Surg. 2018;76(10):2074–80.CrossRef
Metadata
Title
An innovative total temporomandibular joint prosthesis with customized design and 3D printing additive fabrication: a prospective clinical study
Authors
JiSi Zheng
XuZhuo Chen
WenBo Jiang
ShanYong Zhang
MinJie Chen
Chi Yang
Publication date
01-12-2019
Publisher
BioMed Central
Published in
Journal of Translational Medicine / Issue 1/2019
Electronic ISSN: 1479-5876
DOI
https://doi.org/10.1186/s12967-018-1759-1

Other articles of this Issue 1/2019

Journal of Translational Medicine 1/2019 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.