Skip to main content
Top
Published in: Health and Quality of Life Outcomes 1/2020

Open Access 01-12-2020 | Psoriatic Arthritis | Research

Development and psychometric evaluation of the assessment of self-injection questionnaire: an adaptation of the self-injection assessment questionnaire

Authors: Farrah Pompilus, Anna Ciesluk, Sara Strzok, Valerie Ciaravino, Kristina Harris, Boglarka Szegvari, Irina Mountian, Sophie Cleanthous, Juliette Meunier

Published in: Health and Quality of Life Outcomes | Issue 1/2020

Login to get access

Abstract

Background

Patient-reported outcome (PRO) instruments provide robust and effective means of evaluating patients’ treatment experience; however, none adequately cover experience using self-injection devices with enhanced features, such as an electromechanical autoinjector (e-Device). The aim of this study was to develop a PRO instrument that accurately assesses patient experience of using an e-Device and to evaluate its psychometric properties.

Methods

A mixed-methods approach was taken; two parallel, targeted literature reviews were conducted to identify relevant concepts and existing self-injection PRO instruments that could be adapted. Patient feedback obtained from two focus groups was used to inform initial instrument development. The pilot instrument was then administered in a multicenter, open-label, phase 3 clinical study in which patients self-injected certolizumab pegol using an e-Device, to gather evidence of its psychometric qualities. Exit interviews were conducted with a sub-sample of patients enrolled in the study to confirm the appropriateness and clarity of the items included and cognitively debrief the instrument. Confirmatory factor analysis (CFA) was conducted on all items, and each domain’s internal consistency was measured using Cronbach’s ɑ.

Results

The literature searches identified several e-Device-specific concepts related to device features, device function, side effects/reactions/pain, confidence, and interference/convenience in daily life. Seven existing PRO instruments were identified. The Self-Injection Assessment Questionnaire (SIAQ), containing pre- and post-injection questionnaire modules, was selected as most suitable and adapted using feedback from 19 patients in the two focus groups to form the pilot Assessment of Self-Injection (ASI) questionnaire. CFA resulted in some changes to the grouping of items in the post-injection module domains following psychometric evaluation of the ASI. Internal consistency was satisfactory for all pre- and post-injection domains (ɑ > 0.8). Cognitive debriefing results from 12 patient exit interviews confirmed the ASI’s appropriateness and clarity.

Conclusions

The ASI was developed iteratively with patient input and was evaluated in its intended clinical context of use. Psychometric analyses indicated promising cross-sectional results; the ASI was well understood and considered relevant by patients self-injecting using the e-Device, suggesting that it could be used in real-world settings to aid with clinical decision making.
Trial registration: NCT03357471
Appendix
Available only for authorised users
Literature
1.
go back to reference Schwartzman S, Morgan GJ Jr. Does route of administration affect the outcome of TNF antagonist therapy? Arthritis Res Ther. 2004;6(Suppl 2):S19-23.CrossRefPubMed Schwartzman S, Morgan GJ Jr. Does route of administration affect the outcome of TNF antagonist therapy? Arthritis Res Ther. 2004;6(Suppl 2):S19-23.CrossRefPubMed
2.
go back to reference Anderson BJ, Redondo MJ. What can we learn from patient-reported outcomes of insulin pen devices? J Diabetes Sci Technol. 2011;5:1563–71.CrossRefPubMed Anderson BJ, Redondo MJ. What can we learn from patient-reported outcomes of insulin pen devices? J Diabetes Sci Technol. 2011;5:1563–71.CrossRefPubMed
3.
go back to reference Pouls B, Kristensen L, Petersson M, et al. A pilot study examining patient preference and satisfaction for ava, a reusable electronic injection device to administer certolizumab pegol. RMD Open 2019. Pouls B, Kristensen L, Petersson M, et al. A pilot study examining patient preference and satisfaction for ava, a reusable electronic injection device to administer certolizumab pegol. RMD Open 2019.
4.
go back to reference Gadallah MA, Boulos DN, Gebrel A, et al. Assessment of rheumatoid arthritis patients’ adherence to treatment. Am J Med Sci. 2015;349:151–6.CrossRefPubMed Gadallah MA, Boulos DN, Gebrel A, et al. Assessment of rheumatoid arthritis patients’ adherence to treatment. Am J Med Sci. 2015;349:151–6.CrossRefPubMed
5.
go back to reference Gau M, Takasawa K. Initial patient choice of a growth hormone device improves child and adolescent adherence to and therapeutic effects of growth hormone replacement therapy. J Pediatr Endocrinol Metab. 2017;30:989–93.CrossRefPubMed Gau M, Takasawa K. Initial patient choice of a growth hormone device improves child and adolescent adherence to and therapeutic effects of growth hormone replacement therapy. J Pediatr Endocrinol Metab. 2017;30:989–93.CrossRefPubMed
6.
go back to reference van den Bemt BJF, Gettings L, Domanska B, et al. A portfolio of biologic self-injection devices in rheumatology: how patient involvement in device design can improve treatment experience. Drug Deliv. 2019;26:384–92.CrossRefPubMed van den Bemt BJF, Gettings L, Domanska B, et al. A portfolio of biologic self-injection devices in rheumatology: how patient involvement in device design can improve treatment experience. Drug Deliv. 2019;26:384–92.CrossRefPubMed
7.
go back to reference Udalova I, Monaco C, Nanchahal J, et al. Anti-TNF therapy. Microbiol Spectr 2016;4. Udalova I, Monaco C, Nanchahal J, et al. Anti-TNF therapy. Microbiol Spectr 2016;4.
8.
go back to reference Bhoi P, Bessette L, Bell MJ, et al. Adherence and dosing interval of subcutaneous antitumour necrosis factor biologics among patients with inflammatory arthritis: analysis from a Canadian administrative database. BMJ Open. 2017;7:e015872.CrossRefPubMed Bhoi P, Bessette L, Bell MJ, et al. Adherence and dosing interval of subcutaneous antitumour necrosis factor biologics among patients with inflammatory arthritis: analysis from a Canadian administrative database. BMJ Open. 2017;7:e015872.CrossRefPubMed
11.
go back to reference Domanska B, Stumpp O, Poon S, et al. Using patient feedback to optimize the design of a certolizumab pegol electromechanical self-injection device: insights from human factors studies. Adv Ther. 2018;35:100–15.CrossRefPubMed Domanska B, Stumpp O, Poon S, et al. Using patient feedback to optimize the design of a certolizumab pegol electromechanical self-injection device: insights from human factors studies. Adv Ther. 2018;35:100–15.CrossRefPubMed
12.
go back to reference Morse JM. Evolving trends in qualitative research: advances in mixed-method design. Qual Health Res. 2005;15:583–5.CrossRefPubMed Morse JM. Evolving trends in qualitative research: advances in mixed-method design. Qual Health Res. 2005;15:583–5.CrossRefPubMed
15.
go back to reference Rothman M, Burke L, Erickson P, et al. Use of existing patient-reported outcome (PRO) instruments and their modification: the ISPOR good research practices for evaluating and documenting content validity for the use of existing instruments and their modification PRO task force report. Value Health. 2009;12:1075–83.CrossRefPubMed Rothman M, Burke L, Erickson P, et al. Use of existing patient-reported outcome (PRO) instruments and their modification: the ISPOR good research practices for evaluating and documenting content validity for the use of existing instruments and their modification PRO task force report. Value Health. 2009;12:1075–83.CrossRefPubMed
16.
go back to reference Tatla D, Mountian I, Szegvari B, et al. A Multicenter, Open-label study to evaluate the safe and effective use of a new electromechanical auto-injection device for self-injection of certolizumab pegol. Expert Opin Drug Deliv. 2020;17:855–62.CrossRefPubMed Tatla D, Mountian I, Szegvari B, et al. A Multicenter, Open-label study to evaluate the safe and effective use of a new electromechanical auto-injection device for self-injection of certolizumab pegol. Expert Opin Drug Deliv. 2020;17:855–62.CrossRefPubMed
17.
go back to reference Keininger D, Coteur G. Assessment of self-injection experience in patients with rheumatoid arthritis: psychometric validation of the Self-Injection Assessment Questionnaire (SIAQ). Health Qual Life Outcomes. 2011;9:2.CrossRefPubMed Keininger D, Coteur G. Assessment of self-injection experience in patients with rheumatoid arthritis: psychometric validation of the Self-Injection Assessment Questionnaire (SIAQ). Health Qual Life Outcomes. 2011;9:2.CrossRefPubMed
18.
go back to reference Cronbach LJ. Coefficient alpha and the internal structure of tests. Psychometrika. 1951;16:297–334.CrossRef Cronbach LJ. Coefficient alpha and the internal structure of tests. Psychometrika. 1951;16:297–334.CrossRef
19.
go back to reference Nunally JC, Bernstein IH. Psychometric Theory. 3rd ed. New York: Tata McGraw-hill Education; 1994. Nunally JC, Bernstein IH. Psychometric Theory. 3rd ed. New York: Tata McGraw-hill Education; 1994.
20.
go back to reference Weir JP. Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. J Strength Cond Res. 2005;19:231–40.PubMed Weir JP. Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. J Strength Cond Res. 2005;19:231–40.PubMed
21.
go back to reference Kazis LE, Anderson JJ, Meenan RF. Effect sizes for interpreting changes in health status. Med Care. 1989;27:S178–89.CrossRefPubMed Kazis LE, Anderson JJ, Meenan RF. Effect sizes for interpreting changes in health status. Med Care. 1989;27:S178–89.CrossRefPubMed
22.
go back to reference Cohen J. Statistical power analysis for the behavioral sciences. Hillsdale, NJ: L. Erlbaum Associates; 1988. Cohen J. Statistical power analysis for the behavioral sciences. Hillsdale, NJ: L. Erlbaum Associates; 1988.
23.
go back to reference Pleil AM, Kimel M, McCormack J, et al. Psychometric assessment of the Injection Pen Assessment Questionnaire (IPAQ): measuring ease of use and preference with injection pens for human growth hormone. Health Qual Life Outcomes. 2012;10:126.CrossRefPubMed Pleil AM, Kimel M, McCormack J, et al. Psychometric assessment of the Injection Pen Assessment Questionnaire (IPAQ): measuring ease of use and preference with injection pens for human growth hormone. Health Qual Life Outcomes. 2012;10:126.CrossRefPubMed
24.
go back to reference Brod M, Hammer M, Christensen T, et al. Understanding and assessing the impact of treatment in diabetes: the Treatment-Related Impact Measures for Diabetes and Devices (TRIM-Diabetes and TRIM-Diabetes Device). Health Qual Life Outcomes. 2009;7:83.CrossRefPubMed Brod M, Hammer M, Christensen T, et al. Understanding and assessing the impact of treatment in diabetes: the Treatment-Related Impact Measures for Diabetes and Devices (TRIM-Diabetes and TRIM-Diabetes Device). Health Qual Life Outcomes. 2009;7:83.CrossRefPubMed
25.
go back to reference Cramer JA, Cuffel BJ, Divan V, et al. Patient satisfaction with an injection device for multiple sclerosis treatment. Acta Neurol Scand. 2006;113:156–62.CrossRefPubMed Cramer JA, Cuffel BJ, Divan V, et al. Patient satisfaction with an injection device for multiple sclerosis treatment. Acta Neurol Scand. 2006;113:156–62.CrossRefPubMed
26.
go back to reference Demary W, Schwenke H, Rockwitz K, et al. Subcutaneously administered methotrexate for rheumatoid arthritis, by prefilled syringes versus prefilled pens: patient preference and comparison of the self-injection experience. Patient Prefer Adherence. 2014;8:1061–71.PubMed Demary W, Schwenke H, Rockwitz K, et al. Subcutaneously administered methotrexate for rheumatoid arthritis, by prefilled syringes versus prefilled pens: patient preference and comparison of the self-injection experience. Patient Prefer Adherence. 2014;8:1061–71.PubMed
27.
go back to reference Acquadro C, Conway K, Girourdet C, et al. Linguistic validation manual for patient-reported outcomes (PRO) instruments. MAPI research trust, 2004. ISBN:2-9522021-0-9. Acquadro C, Conway K, Girourdet C, et al. Linguistic validation manual for patient-reported outcomes (PRO) instruments. MAPI research trust, 2004. ISBN:2-9522021-0-9.
Metadata
Title
Development and psychometric evaluation of the assessment of self-injection questionnaire: an adaptation of the self-injection assessment questionnaire
Authors
Farrah Pompilus
Anna Ciesluk
Sara Strzok
Valerie Ciaravino
Kristina Harris
Boglarka Szegvari
Irina Mountian
Sophie Cleanthous
Juliette Meunier
Publication date
01-12-2020
Publisher
BioMed Central
Published in
Health and Quality of Life Outcomes / Issue 1/2020
Electronic ISSN: 1477-7525
DOI
https://doi.org/10.1186/s12955-020-01606-7

Other articles of this Issue 1/2020

Health and Quality of Life Outcomes 1/2020 Go to the issue