Abstract

Background

To determine whether quality of life (QOL) and health utility are affected to the same extent among dry eye (DE) patients with short tear film break-up time dry eye (TBUT-DE) with minimal clinical signs were as severe as aqueous-deficient dry eye (ADDE).

Methods

A multicenter cross-sectional study was conducted among DE patients who visited one of 10 eye clinics in Japan. Among the 463 registered patients, this study involved 449 patients with DE who were aged 20 years or older. Ophthalmic examination findings were assessed, including tear film break-up time (TBUT), Schirmer I value, and keratoconjunctival staining score. QOL was evaluated with the Dry Eye-Related Quality-of-Life Score (DEQS; 0 [best], 100 [worst]) and health utility (1 [total health], 0 [worst]) with the Health Utilities Index Mark 3 (HUI-3); scores were stratified by DE subgroup.

Results

Median (interquartile range) of DEQS and HUI-3 scores across all participants were 21.7 (10.0–40.0) and 0.82 (0.69–0.91), respectively. Median (interquartile range) DEQS and HUI-3 scores in the ADDE group were 23.3 (10.0–40.0) and 0.79 (0.69–0.88), respectively; those in the short TBUT-DE group were 23.3 (13.3–38.3) and 0.82 (0.74–0.92), respectively. There were no significant between-group differences in questionnaire scores. Among the ophthalmic examination findings, a weak significant correlation between TBUT, corneal staining score and keratoconjunctival staining score to DEQS; TBUT and Schirmer test values to HUI-3, were seen.

Conclusions

The burden of short TBUT-DE on QOL as assessed by the DEQS and HUI-3 was as severe as that in ADDE. Our findings suggest that clinicians should be aware of the impact of short TBUT-DE on patients QOL and utility values.

Trial registration

University Hospital Medical Information Network (registration no. UMIN 000015890). Registered 10th December 2014, retrospectively registered.
Literature
1.
go back to reference Lemp MA. Report of the National eye Institute/industry workshop on clinical trials in dry eyes. CLAO J. 1995;21(4):221–32.PubMed Lemp MA. Report of the National eye Institute/industry workshop on clinical trials in dry eyes. CLAO J. 1995;21(4):221–32.PubMed
2.
go back to reference The definition and classification of dry eye disease: Report of the definition and classification Subcommittee of the International dry eye. WorkShop (2007). Ocul Surf 2007, 5(2):75–92. The definition and classification of dry eye disease: Report of the definition and classification Subcommittee of the International dry eye. WorkShop (2007). Ocul Surf 2007, 5(2):75–92.
3.
go back to reference Shimazaki J, Ohashi Y, Kinoshita S, Sawa M, Takamura E. Definition and criteria of dry eye. Ganka. 1995;37(7):765–70. Shimazaki J, Ohashi Y, Kinoshita S, Sawa M, Takamura E. Definition and criteria of dry eye. Ganka. 1995;37(7):765–70.
4.
go back to reference Shimazaki J, Tsubota K, Kinoshita S, Ohashi Y, Shimomura Y, Tagawa Y, Hamano T, Takamura E, Yokoi N, Watanabe H, et al. Definition and diagnosis of dry eye 2006. Atarashii Ganka. 2007;24(2):181–4. Shimazaki J, Tsubota K, Kinoshita S, Ohashi Y, Shimomura Y, Tagawa Y, Hamano T, Takamura E, Yokoi N, Watanabe H, et al. Definition and diagnosis of dry eye 2006. Atarashii Ganka. 2007;24(2):181–4.
5.
go back to reference Tsubota K, Yokoi N, Shimazaki J, Watanabe H, Dogru M, Yamada M, Kinoshita S, Kim HM, Tchah HW, Hyon JY, et al. New perspectives on dry eye definition and diagnosis: a consensus report by the Asia dry eye society. Ocul Surf. 2017;15(1):65–76.CrossRefPubMed Tsubota K, Yokoi N, Shimazaki J, Watanabe H, Dogru M, Yamada M, Kinoshita S, Kim HM, Tchah HW, Hyon JY, et al. New perspectives on dry eye definition and diagnosis: a consensus report by the Asia dry eye society. Ocul Surf. 2017;15(1):65–76.CrossRefPubMed
6.
go back to reference Nichols KK, Nichols JJ, Mitchell GL. The lack of association between signs and symptoms in patients with dry eye disease. Cornea. 2004;23(8):762–70.CrossRefPubMed Nichols KK, Nichols JJ, Mitchell GL. The lack of association between signs and symptoms in patients with dry eye disease. Cornea. 2004;23(8):762–70.CrossRefPubMed
7.
go back to reference Kawashima M, Yamada M, Suwaki K, Shigeyasu C, Uchino M, Hiratsuka Y, Yokoi N, Tsubota K. A clinic-based survey of clinical characteristics and practice pattern of dry eye in Japan. Adv Ther. 2017;34(3):732–43.CrossRefPubMed Kawashima M, Yamada M, Suwaki K, Shigeyasu C, Uchino M, Hiratsuka Y, Yokoi N, Tsubota K. A clinic-based survey of clinical characteristics and practice pattern of dry eye in Japan. Adv Ther. 2017;34(3):732–43.CrossRefPubMed
8.
go back to reference Schiffman RM, Christianson MD, Jacobsen G, Hirsch JD, Reis BL. Reliability and validity of the ocular surface disease index. Arch Ophthalmol. 2000;118(5):615–21.CrossRefPubMed Schiffman RM, Christianson MD, Jacobsen G, Hirsch JD, Reis BL. Reliability and validity of the ocular surface disease index. Arch Ophthalmol. 2000;118(5):615–21.CrossRefPubMed
9.
go back to reference Abetz L, Rajagopalan K, Mertzanis P, Begley C, Barnes R, Chalmers R. Development and validation of the impact of dry eye on everyday life (IDEEL) questionnaire, a patient-reported outcomes (PRO) measure for the assessment of the burden of dry eye on patients. Health Qual Life Outcomes. 2011;9:111.CrossRefPubMedPubMedCentral Abetz L, Rajagopalan K, Mertzanis P, Begley C, Barnes R, Chalmers R. Development and validation of the impact of dry eye on everyday life (IDEEL) questionnaire, a patient-reported outcomes (PRO) measure for the assessment of the burden of dry eye on patients. Health Qual Life Outcomes. 2011;9:111.CrossRefPubMedPubMedCentral
10.
go back to reference Sakane Y, Yamaguchi M, Yokoi N, Uchino M, Dogru M, Oishi T, Ohashi Y. Development and validation of the dry eye-related quality-of-life score questionnaire. JAMA Ophthalmol. 2010;131(10):1331–8.CrossRef Sakane Y, Yamaguchi M, Yokoi N, Uchino M, Dogru M, Oishi T, Ohashi Y. Development and validation of the dry eye-related quality-of-life score questionnaire. JAMA Ophthalmol. 2010;131(10):1331–8.CrossRef
11.
go back to reference Toda I, Shimazaki J, Tsubota K. Dry eye with only decreased tear break-up time is sometimes associated with allergic conjunctivitis. Ophthalmology. 1995;102(2):302–9.CrossRefPubMed Toda I, Shimazaki J, Tsubota K. Dry eye with only decreased tear break-up time is sometimes associated with allergic conjunctivitis. Ophthalmology. 1995;102(2):302–9.CrossRefPubMed
12.
go back to reference Nichols KK, Mitchell GL, Zadnik K. Performance and repeatability of the NEI-VFQ-25 in patients with dry eye. Cornea. 2002;21(6):578–83.CrossRefPubMed Nichols KK, Mitchell GL, Zadnik K. Performance and repeatability of the NEI-VFQ-25 in patients with dry eye. Cornea. 2002;21(6):578–83.CrossRefPubMed
13.
go back to reference Mizuno Y, Yamada M, Miyake Y. Association between clinical diagnostic tests and health-related quality of life surveys in patients with dry eye syndrome. Jpn J Ophthalmol. 2010;54(4):259–65.CrossRefPubMed Mizuno Y, Yamada M, Miyake Y. Association between clinical diagnostic tests and health-related quality of life surveys in patients with dry eye syndrome. Jpn J Ophthalmol. 2010;54(4):259–65.CrossRefPubMed
14.
go back to reference Schiffman RM, Walt JG, Jacobsen G, Doyle JJ, Lebovics G, Sumner W. Utility assessment among patients with dry eye disease. Ophthalmology. 2003;110(7):1412–9.CrossRefPubMed Schiffman RM, Walt JG, Jacobsen G, Doyle JJ, Lebovics G, Sumner W. Utility assessment among patients with dry eye disease. Ophthalmology. 2003;110(7):1412–9.CrossRefPubMed
15.
go back to reference Buchholz P, Steeds CS, Stern LS, Wiederkehr DP, Doyle JJ, Katz LM, Figueiredo FC. Utility assessment to measure the impact of dry eye disease. Ocul Surf. 2006;4(3):155–61.CrossRefPubMed Buchholz P, Steeds CS, Stern LS, Wiederkehr DP, Doyle JJ, Katz LM, Figueiredo FC. Utility assessment to measure the impact of dry eye disease. Ocul Surf. 2006;4(3):155–61.CrossRefPubMed
16.
go back to reference Uchino M, Yokoi N, Uchino Y, Dogru M, Kawashima M, Komuro A, Sonomura Y, Kato H, Kinoshita S, Schaumberg DA, et al. Prevalence of dry eye disease and its risk factors in visual display terminal users: the Osaka study. Am J Ophthalmol. 2013;156(4):759–66.CrossRefPubMed Uchino M, Yokoi N, Uchino Y, Dogru M, Kawashima M, Komuro A, Sonomura Y, Kato H, Kinoshita S, Schaumberg DA, et al. Prevalence of dry eye disease and its risk factors in visual display terminal users: the Osaka study. Am J Ophthalmol. 2013;156(4):759–66.CrossRefPubMed
17.
go back to reference Shimazaki-Den S, Dogru M, Higa K, Shimazaki J. Symptoms, visual function, and mucin expression of eyes with tear film instability. Cornea. 2013;32(9):1211–8.CrossRefPubMed Shimazaki-Den S, Dogru M, Higa K, Shimazaki J. Symptoms, visual function, and mucin expression of eyes with tear film instability. Cornea. 2013;32(9):1211–8.CrossRefPubMed
18.
go back to reference Yokoi N, Uchino M, Uchino Y, Dogru M, Kawashima M, Komuro A, Sonomura Y, Kato H, Tsubota K, Kinoshita S. Importance of tear film instability in dry eye disease in office workers using visual display terminals: the Osaka study. Am J Ophthalmol. 2015;159(4):748–54.CrossRefPubMed Yokoi N, Uchino M, Uchino Y, Dogru M, Kawashima M, Komuro A, Sonomura Y, Kato H, Tsubota K, Kinoshita S. Importance of tear film instability in dry eye disease in office workers using visual display terminals: the Osaka study. Am J Ophthalmol. 2015;159(4):748–54.CrossRefPubMed
19.
go back to reference Horsman J, Furlong W, Feeny D, Torrance G. The health utilities index (HUI): concepts, measurement properties and applications. Health Qual Life Outcomes. 2003;1:54.CrossRefPubMedPubMedCentral Horsman J, Furlong W, Feeny D, Torrance G. The health utilities index (HUI): concepts, measurement properties and applications. Health Qual Life Outcomes. 2003;1:54.CrossRefPubMedPubMedCentral
20.
go back to reference Izumi R, Noto S, Uemura T, Sano T, Sato T. Validity and responsiveness of the health utility measures Japanese version in health-related quality of life: evaluation of the use in EuroQol 5-dimension and the health utilities index mark 3. Japanese Association of Occupational Therapists. 2010;29(6):763–72. Izumi R, Noto S, Uemura T, Sano T, Sato T. Validity and responsiveness of the health utility measures Japanese version in health-related quality of life: evaluation of the use in EuroQol 5-dimension and the health utilities index mark 3. Japanese Association of Occupational Therapists. 2010;29(6):763–72.
21.
go back to reference Shimazaki J, Seika D, Saga M, Fukagawa K, Sakata M, Iwasaki M, Okano T, Prospective A. Randomized trial of two Mucin Secretogogues for the treatment of dry eye syndrome in office workers. Sci Rep. 2017;7(1):15210.CrossRefPubMedPubMedCentral Shimazaki J, Seika D, Saga M, Fukagawa K, Sakata M, Iwasaki M, Okano T, Prospective A. Randomized trial of two Mucin Secretogogues for the treatment of dry eye syndrome in office workers. Sci Rep. 2017;7(1):15210.CrossRefPubMedPubMedCentral
22.
go back to reference Shigeyasu C, Yamada M, Akune Y, Fukui M. Diquafosol for soft contact Lens dryness: clinical evaluation and tear analysis. Optom Vis Sci. 2016;93(8):973–8.CrossRefPubMed Shigeyasu C, Yamada M, Akune Y, Fukui M. Diquafosol for soft contact Lens dryness: clinical evaluation and tear analysis. Optom Vis Sci. 2016;93(8):973–8.CrossRefPubMed
23.
go back to reference Furlong WJ, Feeny DH, Torrance GW, Goldsmith C, Depauw S, Boyle M, Denton M, Zhu Z: Multiplicative multi-attribute utility function for the health utilities index mark 3 (HUI3) system: a technical report. McMaster University Centre for Health Economics and Policy Analysis Working Paper 1998:98–11. Furlong WJ, Feeny DH, Torrance GW, Goldsmith C, Depauw S, Boyle M, Denton M, Zhu Z: Multiplicative multi-attribute utility function for the health utilities index mark 3 (HUI3) system: a technical report. McMaster University Centre for Health Economics and Policy Analysis Working Paper 1998:98–11.
24.
25.
go back to reference Toda I, Fujishima H, Tsubota K. Ocular fatigue is the major symptom of dry eye. Acta Ophthalmol. 1993;71(3):347–52.CrossRef Toda I, Fujishima H, Tsubota K. Ocular fatigue is the major symptom of dry eye. Acta Ophthalmol. 1993;71(3):347–52.CrossRef
26.
go back to reference Uchino Y, Uchino M, Dogru M, Ward S, Yokoi N, Tsubota K. Changes in dry eye diagnostic status following implementation of revised Japanese dry eye diagnostic criteria. Jpn J Ophthalmol. 2012;56(1):8–13.CrossRefPubMed Uchino Y, Uchino M, Dogru M, Ward S, Yokoi N, Tsubota K. Changes in dry eye diagnostic status following implementation of revised Japanese dry eye diagnostic criteria. Jpn J Ophthalmol. 2012;56(1):8–13.CrossRefPubMed
27.
go back to reference Tarride JE, Burke N, Bischof M, Hopkins RB, Goeree L, Campbell K, Xie F, O'Reilly D, Goeree R. A review of health utilities across conditions common in paediatric and adult populations. Health Qual Life Outcomes. 2010;8:12.CrossRefPubMedPubMedCentral Tarride JE, Burke N, Bischof M, Hopkins RB, Goeree L, Campbell K, Xie F, O'Reilly D, Goeree R. A review of health utilities across conditions common in paediatric and adult populations. Health Qual Life Outcomes. 2010;8:12.CrossRefPubMedPubMedCentral
28.
go back to reference Torrance GW. Utility approach to measuring health-related quality of life. J Chronic Dis. 1987;40(6):593–603.CrossRefPubMed Torrance GW. Utility approach to measuring health-related quality of life. J Chronic Dis. 1987;40(6):593–603.CrossRefPubMed
29.
go back to reference von Neumann J, Morgenstern O. Theory of games and economic behaviour. 3rd ed. New York: Wiley; 1953. von Neumann J, Morgenstern O. Theory of games and economic behaviour. 3rd ed. New York: Wiley; 1953.
30.
go back to reference Bron AJ, Tomlinson A, Foulks GN, Pepose JS, Baudouin C, Geerling G, Nichols KK, Lemp MA. Rethinking dry eye disease: a perspective on clinical implications. Ocul Surf. 2014;12(2 Suppl):S1–31.CrossRefPubMed Bron AJ, Tomlinson A, Foulks GN, Pepose JS, Baudouin C, Geerling G, Nichols KK, Lemp MA. Rethinking dry eye disease: a perspective on clinical implications. Ocul Surf. 2014;12(2 Suppl):S1–31.CrossRefPubMed
31.
go back to reference Sullivan BD, Crews LA, Messmer EM, Foulks GN, Nichols KK, Baenninger P, Geerling G, Figueiredo F, Lemp MA. Correlations between commonly used objective signs and symptoms for the diagnosis of dry eye disease: clinical implications. Acta Ophthalmol. 2014;92(2):161–6.CrossRefPubMed Sullivan BD, Crews LA, Messmer EM, Foulks GN, Nichols KK, Baenninger P, Geerling G, Figueiredo F, Lemp MA. Correlations between commonly used objective signs and symptoms for the diagnosis of dry eye disease: clinical implications. Acta Ophthalmol. 2014;92(2):161–6.CrossRefPubMed
32.
go back to reference Galor A, Felix ER, Feuer W, Shalabi N, Martin ER, Margolis TP, Sarantopoulos CD, Levitt RC. Dry eye symptoms align more closely to non-ocular conditions than to tear film parameters. Br J Ophthalmol. 2015;99(8):1126–9.CrossRefPubMed Galor A, Felix ER, Feuer W, Shalabi N, Martin ER, Margolis TP, Sarantopoulos CD, Levitt RC. Dry eye symptoms align more closely to non-ocular conditions than to tear film parameters. Br J Ophthalmol. 2015;99(8):1126–9.CrossRefPubMed
33.
go back to reference Fukui M, Yamada M, Akune Y, Shigeyasu C, Tsubota K. Fluorophotometric analysis of the ocular surface Glycocalyx in soft contact Lens wearers. Curr Eye Res. 2016;41(1):9–14.CrossRefPubMed Fukui M, Yamada M, Akune Y, Shigeyasu C, Tsubota K. Fluorophotometric analysis of the ocular surface Glycocalyx in soft contact Lens wearers. Curr Eye Res. 2016;41(1):9–14.CrossRefPubMed
34.
36.
go back to reference Lemp MA. Evaluation and differential diagnosis of keratoconjunctivitis sicca. J Rheumatol Suppl. 2000;61:11–4.PubMed Lemp MA. Evaluation and differential diagnosis of keratoconjunctivitis sicca. J Rheumatol Suppl. 2000;61:11–4.PubMed
37.
go back to reference Liu H, Begley C, Chen M, Bradley A, Bonanno J, McNamara NA, Nelson JD, Simpson T. A link between tear instability and hyperosmolarity in dry eye. Invest Ophthalmol Vis Sci. 2009;50(8):3671–9.CrossRefPubMed Liu H, Begley C, Chen M, Bradley A, Bonanno J, McNamara NA, Nelson JD, Simpson T. A link between tear instability and hyperosmolarity in dry eye. Invest Ophthalmol Vis Sci. 2009;50(8):3671–9.CrossRefPubMed
38.
go back to reference Parra A, Madrid R, Echevarria D, del Olmo S, Morenilla-Palao C, Acosta MC, Gallar J, Dhaka A, Viana F, Belmonte C. Ocular surface wetness is regulated by TRPM8-dependent cold thermoreceptors of the cornea. Nat Med. 2010;16(12):1396–9.CrossRefPubMed Parra A, Madrid R, Echevarria D, del Olmo S, Morenilla-Palao C, Acosta MC, Gallar J, Dhaka A, Viana F, Belmonte C. Ocular surface wetness is regulated by TRPM8-dependent cold thermoreceptors of the cornea. Nat Med. 2010;16(12):1396–9.CrossRefPubMed
39.
go back to reference Rosenthal P, Borsook D. The corneal pain system. Part I: the missing piece of the dry eye puzzle. Ocul Surf. 2012;10(1):2–14.CrossRefPubMed Rosenthal P, Borsook D. The corneal pain system. Part I: the missing piece of the dry eye puzzle. Ocul Surf. 2012;10(1):2–14.CrossRefPubMed
40.
go back to reference Weinberger M, Oddone EZ, Samsa GP, Landsman PB. Are health-related quality-of-life measures affected by the mode of administration? J Clin Epidemiol. 1996;49(2):135–40.CrossRefPubMed Weinberger M, Oddone EZ, Samsa GP, Landsman PB. Are health-related quality-of-life measures affected by the mode of administration? J Clin Epidemiol. 1996;49(2):135–40.CrossRefPubMed
Metadata
Title
Quality of life measures and health utility values among dry eye subgroups
Authors
Chika Shigeyasu
Masakazu Yamada
Motoko Kawashima
Kazuhisa Suwaki
Miki Uchino
Yoshimune Hiratsuka
Norihiko Yokoi
Kazuo Tsubota
for the DECS-J study group
Publication date
01-12-2018
Publisher
BioMed Central
Published in
Health and Quality of Life Outcomes / Issue 1/2018
Electronic ISSN: 1477-7525
DOI
https://doi.org/10.1186/s12955-018-0999-3

Other articles of this Issue 1/2018

Health and Quality of Life Outcomes 1/2018 Go to the issue