Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2020

01-12-2020 | Computed Tomography | Research article

Motion-preserving treatment of unstable atlas fracture: transoral anterior C1-ring osteosynthesis using a laminoplasty plate

Authors: Xiaobao Zou, Beiping Ouyang, Binbin Wang, Haozhi Yang, Su Ge, Yuyue Chen, Ling Ni, Shuang Zhang, Hong Xia, Zenghui Wu, Xiangyang Ma

Published in: BMC Musculoskeletal Disorders | Issue 1/2020

Login to get access

Abstract

Background

C1-ring osteosynthesis is a valid alternative to posterior C1–C2 or C0–C2 fusion to preserve important C1–C2 motion in the treatment of unstable atlas fractures. Nevertheless, the fixation instruments used in current studies for transoral anterior C1-ring osteosynthesis were not suitable for anterior anatomy of the atlas or did not have reduction mechanism. We therefore present this report to investigate preliminary clinical effects of transoral anterior C1-ring osteosynthesis using a laminoplasty plate in unstable atlas fractures.

Methods

From January 2014 to December 2017, 13 patients with unstable atlas fractures were retrospectively reviewed. All patients were treated with transoral anterior C1-ring osteosynthesis using a laminoplasty plate. Pre- and postoperative images were obtained to assess reduction of the fracture, internal fixation placement, and bone union. Neurological function, range of motion, and pain levels were evaluated clinically on follow-up.

Results

The surgeries were successfully performed in all cases. The average follow-up duration was 16.6 ± 4.4 months (range 12–24 months). One patient suffered screw loosening after operation and underwent replacement operation subsequently. Satisfactory clinical outcomes were achieved in all patients with ideal fracture reduction, reliable plate placement, well-preserved range of motion, and neck pain alleviation. All patients achieved bone union of fractures without loss of reduction or implant failure or C1–C2 instability during the follow-up. No vascular or neurological complication was noted during the operation and follow-up.

Conclusions

Transoral anterior C1-ring osteosynthesis using a laminoplasty plate is a effective surgical treatment for unstable atlas fractures. This technique has a ingenious reduction mechanism, and can provide satisfactory bone union and preservation of C1–C2 motion.
Literature
1.
go back to reference Matthiessen C, Robinson Y. Epidemiology of atlas fractures--a national registry-based cohort study of 1,537 cases. Spine J. 2015;15:2332–7.CrossRef Matthiessen C, Robinson Y. Epidemiology of atlas fractures--a national registry-based cohort study of 1,537 cases. Spine J. 2015;15:2332–7.CrossRef
2.
go back to reference Zhang YS, Zhang JX, Yang QG, Li W, Tao H, Shen CL. Posterior osteosynthesis with monoaxial lateral mass screw-rod system for unstable C1 burst fractures. Spine J. 2018;18:107–14.CrossRef Zhang YS, Zhang JX, Yang QG, Li W, Tao H, Shen CL. Posterior osteosynthesis with monoaxial lateral mass screw-rod system for unstable C1 burst fractures. Spine J. 2018;18:107–14.CrossRef
3.
go back to reference Lee C, Woodring JH. Unstable Jefferson variant atlas fractures: an unrecognized cervical injury. Am J Neuroradiol. 1991;12:1105–10.PubMed Lee C, Woodring JH. Unstable Jefferson variant atlas fractures: an unrecognized cervical injury. Am J Neuroradiol. 1991;12:1105–10.PubMed
4.
go back to reference Lee TT, Green BA, Petrin DR. Treatment of stable burst fracture of the atlas (Jefferson fracture) with rigid cervical collar. Spine (Phila Pa 1976). 1998;23:1963–7.CrossRef Lee TT, Green BA, Petrin DR. Treatment of stable burst fracture of the atlas (Jefferson fracture) with rigid cervical collar. Spine (Phila Pa 1976). 1998;23:1963–7.CrossRef
5.
go back to reference Kim MK, Shin JJ. Comparison of radiological and clinical outcomes after surgical reduction with fixation or halo-vest immobilization for treating unstable atlas fractures. Acta Neurochir. 2019;161:685–93.CrossRef Kim MK, Shin JJ. Comparison of radiological and clinical outcomes after surgical reduction with fixation or halo-vest immobilization for treating unstable atlas fractures. Acta Neurochir. 2019;161:685–93.CrossRef
6.
go back to reference Kim HS, Cloney MB, Koski TR, Smith ZA, Dahdaleh NS. Management of isolated atlas fractures: a retrospective study of 65 patients. World Neurosurg. 2018;111:e316–22.CrossRef Kim HS, Cloney MB, Koski TR, Smith ZA, Dahdaleh NS. Management of isolated atlas fractures: a retrospective study of 65 patients. World Neurosurg. 2018;111:e316–22.CrossRef
7.
go back to reference Ruf M, Melcher R, Harms J. Transoral reduction and osteosynthesis C1 as a function-preserving option in the treatment of unstable Jefferson fractures. Spine (Phila Pa 1976). 2004;29:823–7.CrossRef Ruf M, Melcher R, Harms J. Transoral reduction and osteosynthesis C1 as a function-preserving option in the treatment of unstable Jefferson fractures. Spine (Phila Pa 1976). 2004;29:823–7.CrossRef
8.
go back to reference Ma W, Xu N, Hu Y, Li G, Zhao L, Sun S, Jiang W, Liu G, Gu Y, Liu J. Unstable atlas fracture treatment by anterior plate C1-ring osteosynthesis using a transoral approach. Eur Spine J. 2013;22:2232–9.CrossRef Ma W, Xu N, Hu Y, Li G, Zhao L, Sun S, Jiang W, Liu G, Gu Y, Liu J. Unstable atlas fracture treatment by anterior plate C1-ring osteosynthesis using a transoral approach. Eur Spine J. 2013;22:2232–9.CrossRef
9.
go back to reference Hu Y, Albert TJ, Kepler CK, Ma WH, Yuan ZS, Dong WX. Unstable Jefferson fractures: results of transoral osteosynthesis. Indian J Orthop. 2014;48:145–51.CrossRef Hu Y, Albert TJ, Kepler CK, Ma WH, Yuan ZS, Dong WX. Unstable Jefferson fractures: results of transoral osteosynthesis. Indian J Orthop. 2014;48:145–51.CrossRef
10.
go back to reference Landells CD, Van Peteghem PK. Fractures of the atlas: classification, treatment and morbidity. Spine (Phila Pa 1976). 1998;13:450–2.CrossRef Landells CD, Van Peteghem PK. Fractures of the atlas: classification, treatment and morbidity. Spine (Phila Pa 1976). 1998;13:450–2.CrossRef
11.
go back to reference Dickman CA, Greene KA, Sonntag VK. Injuries involving the transverse atlantal ligament: classification and treatment guidelines based upon experience with 39 injuries. Neurosurgery. 1996;38:44–50.CrossRef Dickman CA, Greene KA, Sonntag VK. Injuries involving the transverse atlantal ligament: classification and treatment guidelines based upon experience with 39 injuries. Neurosurgery. 1996;38:44–50.CrossRef
12.
go back to reference Teo EC, Ng HW. First cervical vertebra (atlas) fracture mechanism studies using finite element method. J Biomech. 2001;34:13–21.CrossRef Teo EC, Ng HW. First cervical vertebra (atlas) fracture mechanism studies using finite element method. J Biomech. 2001;34:13–21.CrossRef
13.
go back to reference Lleu M, Charles YP, Blondel B, Barresi L, Nicot B, Challier V, Godard J, Kouyoumdjian P, Lonjon N, Marinho P, Freitas E, Schuller S, Fuentes S, Allia J, Berthiller J, Barrey C. C1 fracture: analysis of consolidation and complications rates in a prospective multicenter series. Orthop Traumatol Surg Res. 2018;104:1049–54.CrossRef Lleu M, Charles YP, Blondel B, Barresi L, Nicot B, Challier V, Godard J, Kouyoumdjian P, Lonjon N, Marinho P, Freitas E, Schuller S, Fuentes S, Allia J, Berthiller J, Barrey C. C1 fracture: analysis of consolidation and complications rates in a prospective multicenter series. Orthop Traumatol Surg Res. 2018;104:1049–54.CrossRef
14.
go back to reference Kamal Y, Ortho MS, Khan HA, Gani N, Haq AU, Gul S, Singh D. Atlas and axis injuries role of Halovest. Int J Health Sci (Qassim). 2014;8:335–45. Kamal Y, Ortho MS, Khan HA, Gani N, Haq AU, Gul S, Singh D. Atlas and axis injuries role of Halovest. Int J Health Sci (Qassim). 2014;8:335–45.
15.
go back to reference Dvorak MF, Johnson MG, Boyd M, Johnson G, Kwon BK, Fisher CG. Long-term health-related quality of life outcomes following Jefferson-type burst fractures of the atlas. J Neurosurg Spine. 2005;2:411–7.CrossRef Dvorak MF, Johnson MG, Boyd M, Johnson G, Kwon BK, Fisher CG. Long-term health-related quality of life outcomes following Jefferson-type burst fractures of the atlas. J Neurosurg Spine. 2005;2:411–7.CrossRef
16.
go back to reference Horn EM, Theodore N, Feiz-Erfan I, Lekovic GP, Dickman CA, Sonntag VK. Complications of halo fixation in the elderly. J Neurosurg Spine. 2006;5:46–9.CrossRef Horn EM, Theodore N, Feiz-Erfan I, Lekovic GP, Dickman CA, Sonntag VK. Complications of halo fixation in the elderly. J Neurosurg Spine. 2006;5:46–9.CrossRef
17.
go back to reference Kukreja S, Ambekar S, Sin AH, Nanda A. Occipitocervical fusion surgery: review of operative techniques and results. J Neurol Surg B Skull Base. 2015;76:331–9.CrossRef Kukreja S, Ambekar S, Sin AH, Nanda A. Occipitocervical fusion surgery: review of operative techniques and results. J Neurol Surg B Skull Base. 2015;76:331–9.CrossRef
18.
go back to reference Huang DG, Hao DJ, He BR, Wu QN, Liu TJ, Wang XD, Guo H, Fang XY. Posterior atlantoaxial fixation: a review of all techniques. Spine J. 2015;15:2271–81.CrossRef Huang DG, Hao DJ, He BR, Wu QN, Liu TJ, Wang XD, Guo H, Fang XY. Posterior atlantoaxial fixation: a review of all techniques. Spine J. 2015;15:2271–81.CrossRef
19.
go back to reference Sim HB, Lee JW, Park JT, Mindea SA, Lim J, Park J. Biomechanical evaluations of various c1-c2 posterior fixation techniques. Spine (Phila Pa 1976). 2011;36:E401–7.CrossRef Sim HB, Lee JW, Park JT, Mindea SA, Lim J, Park J. Biomechanical evaluations of various c1-c2 posterior fixation techniques. Spine (Phila Pa 1976). 2011;36:E401–7.CrossRef
20.
go back to reference Sutterlin CE, Bianchi JR, Kunz DN, Zdeblick TA, Johnson WM, Rapoff AJ. Biomechanical evaluation of occipitocervical fixation devices. J Spinal Disord. 2001;14:185–92.CrossRef Sutterlin CE, Bianchi JR, Kunz DN, Zdeblick TA, Johnson WM, Rapoff AJ. Biomechanical evaluation of occipitocervical fixation devices. J Spinal Disord. 2001;14:185–92.CrossRef
21.
go back to reference Ryken TC, Aarabi B, Dhall SS, Gelb DE, Hurlbert RJ, Rozzelle CJ, Theodore N, Walters BC, Hadley MN. Management of isolated fractures of the atlas in adults. Neurosurgery. 2013;72(Suppl 2):127–31.CrossRef Ryken TC, Aarabi B, Dhall SS, Gelb DE, Hurlbert RJ, Rozzelle CJ, Theodore N, Walters BC, Hadley MN. Management of isolated fractures of the atlas in adults. Neurosurgery. 2013;72(Suppl 2):127–31.CrossRef
22.
go back to reference Hein C, Richter HP, Rath SA. Atlantoaxial screw fixation for the treatment of isolated and combined unstable Jefferson fractures–experiences with 8 patients. Acta Neurochir (Wien). 2002;144:1187–92.CrossRef Hein C, Richter HP, Rath SA. Atlantoaxial screw fixation for the treatment of isolated and combined unstable Jefferson fractures–experiences with 8 patients. Acta Neurochir (Wien). 2002;144:1187–92.CrossRef
23.
go back to reference Dickman C. Re: Ruf M, Melcher R, Harms J. Transoral reduction and osteosynthesis C1 as a function-preserving option in the treatment of unstable Jefferson fractures. Spine (Phila Pa 1976). 2004; 29:823–827. Spine (Phila Pa 1976). 2004;29(19):2196–7. Dickman C. Re: Ruf M, Melcher R, Harms J. Transoral reduction and osteosynthesis C1 as a function-preserving option in the treatment of unstable Jefferson fractures. Spine (Phila Pa 1976). 2004; 29:823–827. Spine (Phila Pa 1976). 2004;29(19):2196–7.
24.
go back to reference Koller H, Resch H, Tauber M, Zenner J, Augat P, Penzkofer R, Acosta F, Kolb K, Kathrein A, Hitzl W. A biomechanical rationale for C1-ring osteosynthesis as treatment for displaced Jefferson burst fractures with incompetency of the transverse atlantal ligament. Eur Spine J. 2010;19:1288–98.CrossRef Koller H, Resch H, Tauber M, Zenner J, Augat P, Penzkofer R, Acosta F, Kolb K, Kathrein A, Hitzl W. A biomechanical rationale for C1-ring osteosynthesis as treatment for displaced Jefferson burst fractures with incompetency of the transverse atlantal ligament. Eur Spine J. 2010;19:1288–98.CrossRef
25.
go back to reference Li-Jun L, Ying-Chao H, Ming-Jie Y, Jie P, Jun T, Dong-Sheng Z. Biomechanical analysis of the longitudinal ligament of upper cervical spine in maintaining atlantoaxial stability. Spinal Cord. 2014;52:342–7.CrossRef Li-Jun L, Ying-Chao H, Ming-Jie Y, Jie P, Jun T, Dong-Sheng Z. Biomechanical analysis of the longitudinal ligament of upper cervical spine in maintaining atlantoaxial stability. Spinal Cord. 2014;52:342–7.CrossRef
26.
go back to reference He B, Yan L, Zhao Q, Chang Z, Hao D. Self-designed posterior atlas polyaxial lateral mass screw-plate fixation for unstable atlas fracture. Spine J. 2014;14:2892–6.CrossRef He B, Yan L, Zhao Q, Chang Z, Hao D. Self-designed posterior atlas polyaxial lateral mass screw-plate fixation for unstable atlas fracture. Spine J. 2014;14:2892–6.CrossRef
27.
go back to reference Li L, Teng H, Pan J, Qian L, Zeng C, Sun G, Yang M, Tan J. Direct posterior C1 lateral mass screws compression reduction and osteosynthesis in the treatment of unstable jefferson fractures. Spine (Phila Pa 1976). 2011;36:E1046–51.CrossRef Li L, Teng H, Pan J, Qian L, Zeng C, Sun G, Yang M, Tan J. Direct posterior C1 lateral mass screws compression reduction and osteosynthesis in the treatment of unstable jefferson fractures. Spine (Phila Pa 1976). 2011;36:E1046–51.CrossRef
28.
go back to reference Yin QS, Li XS, Bai ZH, Mai XH, Xia H, Wu ZH, Ma XY, Ai FZ, Wang JH, Zhang K. An 11-year review of the TARP procedure in the treatment of atlantoaxial dislocation. Spine (Phila Pa 1976). 2016;41:E1151–8.CrossRef Yin QS, Li XS, Bai ZH, Mai XH, Xia H, Wu ZH, Ma XY, Ai FZ, Wang JH, Zhang K. An 11-year review of the TARP procedure in the treatment of atlantoaxial dislocation. Spine (Phila Pa 1976). 2016;41:E1151–8.CrossRef
Metadata
Title
Motion-preserving treatment of unstable atlas fracture: transoral anterior C1-ring osteosynthesis using a laminoplasty plate
Authors
Xiaobao Zou
Beiping Ouyang
Binbin Wang
Haozhi Yang
Su Ge
Yuyue Chen
Ling Ni
Shuang Zhang
Hong Xia
Zenghui Wu
Xiangyang Ma
Publication date
01-12-2020
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2020
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-020-03575-w

Other articles of this Issue 1/2020

BMC Musculoskeletal Disorders 1/2020 Go to the issue