Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2019

Open Access 01-12-2019 | Research article

Loading capacity of dynamic knee spacers: a comparison between hand-moulded and COPAL spacers

Published in: BMC Musculoskeletal Disorders | Issue 1/2019

Login to get access

Abstract

Background

The two-stage revision protocol represents the current gold standard for treating infected total knee replacement implants. Allowing early mobility with weight-bearing between staged procedures will enable early restoration to knee function. So, the mechanical performance of knee spacers is a key issue. Commercially available moulds are often used as they are easy to prepare and produce smoother surfaces of the articulating parts. However, they are costly, and only for single use. A cost-effective alternative is the surgeon-made hand-moulded spacers. In this study, we wanted to determine how the hand-moulded spacers will compare biomechanically with the commercially available COPAL spacers.

Methods

Seven cadaveric knees were implanted with knee spacers fabricated using COPAL knee moulds. The same surgeon implanted eight cadaveric knees with hand-moulded spacers. In the first test protocol, an axial load was applied at 200 mm/min till failure. In the second test protocol, the knees were cyclically loaded in five steps of 1000 cycles each from 30-400 N, 30-600 N, 30-800 N, 30-1000 N, 30-1200 N at 1.5 Hz.

Results

COPAL knee spacers demonstrated a maximum load and mean stiffness of 5202 (± 486.9) N and 1098 (± 201.5) N/mm respectively. The hand-moulded knee spacers demonstrated a mean stiffness of 4509 (± 1092.6) N and 1008.7 (± 275.4) N/mm respectively. The maximum axial displacement was 1.19 ± 0.57 mm and 0.89 ± 0.30 mm for specimens implanted with COPAL knee spacers and hand-moulded spacers respectively. The differences between COPAL and hand-moulded knee spacers were not statistically different.

Conclusions

Our study demonstrated that dynamic knee spacers may be able to withstand more than the touch-down load permitted in previous studies, and this may allow more weight-bearing during ambulation. Previous studies have demonstrated that hand-moulded knee spacers have similar advantages to commercially available dynamic spacers with respect to mobility, pain, bone loss, and reinfection rate. Given that ambulation with weight-bearing up to 1200 N is permitted during rehabilitation, it may be more cost-effective to fabricate hand-moulded spacers in revision total knee arthroplasty.
Appendix
Available only for authorised users
Literature
1.
go back to reference Ocguder A, Firat A, Tecimel O. Two-stage total infected knee arthroplasty treatment with articulating cement spacer. Arch Orthop Trauma Surg. 2010:719–25.PubMedCrossRef Ocguder A, Firat A, Tecimel O. Two-stage total infected knee arthroplasty treatment with articulating cement spacer. Arch Orthop Trauma Surg. 2010:719–25.PubMedCrossRef
3.
go back to reference Gooding CR, Masri BA, Duncan CP, Greidanus NV, Garbuz DS. Durable infection control and function with the PROSTALAC spacer in two-stage revision for infected knee Arthroplasty. Clin Orthop Relat Res. 2011;469:985–93.PubMedCrossRef Gooding CR, Masri BA, Duncan CP, Greidanus NV, Garbuz DS. Durable infection control and function with the PROSTALAC spacer in two-stage revision for infected knee Arthroplasty. Clin Orthop Relat Res. 2011;469:985–93.PubMedCrossRef
4.
go back to reference Castelli CC, Gotti V, Ferrari R. Two-stage treatment of infected total knee arthroplasty: two to thirteen year experience using an articulating preformed spacer. Int Orthop. 2014;38:405–12.PubMedPubMedCentralCrossRef Castelli CC, Gotti V, Ferrari R. Two-stage treatment of infected total knee arthroplasty: two to thirteen year experience using an articulating preformed spacer. Int Orthop. 2014;38:405–12.PubMedPubMedCentralCrossRef
5.
go back to reference Charette RS, Melnic CM. Two-stage revision Arthroplasty for the treatment of prosthetic joint infection. Curr Rev Musculoskelet Med. 2018;11(3):332–40.PubMedPubMedCentralCrossRef Charette RS, Melnic CM. Two-stage revision Arthroplasty for the treatment of prosthetic joint infection. Curr Rev Musculoskelet Med. 2018;11(3):332–40.PubMedPubMedCentralCrossRef
6.
go back to reference Emerson RH, Muncie M, Tarbox TR, Higgins LL. Comparison of a static with a mobile spacer in total knee infection. Clin Orthop Relat Res. 2002;404:132–8.CrossRef Emerson RH, Muncie M, Tarbox TR, Higgins LL. Comparison of a static with a mobile spacer in total knee infection. Clin Orthop Relat Res. 2002;404:132–8.CrossRef
7.
go back to reference Cuckler JM. The infected total knee: management options. J Arthroplast. 2005;20(S2):33–6.CrossRef Cuckler JM. The infected total knee: management options. J Arthroplast. 2005;20(S2):33–6.CrossRef
9.
go back to reference Bernard L, Legout L, Zürcher-Pfund L, Stern R, Rohner P, Peter R, et al. Six weeks of antibiotic treatment is sufficient following surgery for septic arthroplasty. J Inf Secur. 2010;61(2):125–32. Bernard L, Legout L, Zürcher-Pfund L, Stern R, Rohner P, Peter R, et al. Six weeks of antibiotic treatment is sufficient following surgery for septic arthroplasty. J Inf Secur. 2010;61(2):125–32.
10.
go back to reference Johnson AJ, Sayeed SA, Naziri Q, Khanuja HS, Mont MA. Minimizing dynamic knee spacer complications in infected revision arthroplasty. Clin Orthop Relat Res. 2012;470(1):220–7.PubMedCrossRef Johnson AJ, Sayeed SA, Naziri Q, Khanuja HS, Mont MA. Minimizing dynamic knee spacer complications in infected revision arthroplasty. Clin Orthop Relat Res. 2012;470(1):220–7.PubMedCrossRef
11.
go back to reference Dubée V, Zeller V, Lhotellier L, Kitzis MD, Ziza JM, Mamoudy P, et al. Continuous high-dose vancomycin combination therapy for methicillin-resistant staphylococcal prosthetic hip infection: a prospective cohort study. Clin Microbiol Infect. 2013;19(2):E98–E105.PubMedCrossRef Dubée V, Zeller V, Lhotellier L, Kitzis MD, Ziza JM, Mamoudy P, et al. Continuous high-dose vancomycin combination therapy for methicillin-resistant staphylococcal prosthetic hip infection: a prospective cohort study. Clin Microbiol Infect. 2013;19(2):E98–E105.PubMedCrossRef
12.
go back to reference Chiang ER, Su YP, Chen TH, Chiu FY, Chen WM. Comparison of articulating and static spacers regarding infection with resistant organisms in total knee arthroplasty. Acta Orthop. 2011;82(4):460–4.PubMedPubMedCentralCrossRef Chiang ER, Su YP, Chen TH, Chiu FY, Chen WM. Comparison of articulating and static spacers regarding infection with resistant organisms in total knee arthroplasty. Acta Orthop. 2011;82(4):460–4.PubMedPubMedCentralCrossRef
13.
go back to reference Booth REJ, Lotke PA. The results of spacer block technique in revision of infected total knee arthroplasty. Clin Orthop Relat Res. 1989;248:57–60. Booth REJ, Lotke PA. The results of spacer block technique in revision of infected total knee arthroplasty. Clin Orthop Relat Res. 1989;248:57–60.
14.
go back to reference McPherson EJ, Lewonowski K, Dorr LD. Techniques in arthroplasty. Use of an articulated PMMA spacer in the infected total knee arthroplasty. J Arthroplast. 1995;10(1):87–9.CrossRef McPherson EJ, Lewonowski K, Dorr LD. Techniques in arthroplasty. Use of an articulated PMMA spacer in the infected total knee arthroplasty. J Arthroplast. 1995;10(1):87–9.CrossRef
15.
go back to reference Calton TF, Fehring TK, Griffin WL. Bone loss associated with the use of spacer blocks in infected total knee arthroplasty. Clin Orthop Relat Res. 1997;345:148–54.CrossRef Calton TF, Fehring TK, Griffin WL. Bone loss associated with the use of spacer blocks in infected total knee arthroplasty. Clin Orthop Relat Res. 1997;345:148–54.CrossRef
16.
go back to reference Fehring TK, Odum S, Calton TF, Mason JB. Articulating versus static spacers in revision total knee arthroplasty for sepsis. Ranawat Award Clin Orthop Relat Res. 2000;380:9–16.CrossRef Fehring TK, Odum S, Calton TF, Mason JB. Articulating versus static spacers in revision total knee arthroplasty for sepsis. Ranawat Award Clin Orthop Relat Res. 2000;380:9–16.CrossRef
18.
go back to reference Siebel T, Kelm J, Porsch M, Regitz T, Neumann WH. Two-stage exchange of infected knee arthroplasty with an prosthesis-like interim cement spacer. Acta Orthop Belg. 2002;68(2):150–6.PubMed Siebel T, Kelm J, Porsch M, Regitz T, Neumann WH. Two-stage exchange of infected knee arthroplasty with an prosthesis-like interim cement spacer. Acta Orthop Belg. 2002;68(2):150–6.PubMed
19.
go back to reference Haleem AA, Berry DJ, Hanssen AD. Mid-term to long-term Followup of two-stage Reimplantation for infected Total knee Arthroplasty. Clin Orthop Relat Res. 2004;428:35–9.CrossRef Haleem AA, Berry DJ, Hanssen AD. Mid-term to long-term Followup of two-stage Reimplantation for infected Total knee Arthroplasty. Clin Orthop Relat Res. 2004;428:35–9.CrossRef
21.
go back to reference Mazzucchelli L, Rosso F, Marmotti A, Bonasia DE, Bruzzone M, Rossi R. The use of spacers (static and mobile) in infection knee arthroplasty. Curr Rev Musculoskelet Med. 2015;8:373–82.PubMedPubMedCentralCrossRef Mazzucchelli L, Rosso F, Marmotti A, Bonasia DE, Bruzzone M, Rossi R. The use of spacers (static and mobile) in infection knee arthroplasty. Curr Rev Musculoskelet Med. 2015;8:373–82.PubMedPubMedCentralCrossRef
22.
go back to reference Hofmann AA, Goldberg T, Tanner AM, Kurtin SM. Treatment of infected Total knee Arthroplasty using an articulating spacer. Clin Orthop Relat Res. 2005;430:125–31.CrossRef Hofmann AA, Goldberg T, Tanner AM, Kurtin SM. Treatment of infected Total knee Arthroplasty using an articulating spacer. Clin Orthop Relat Res. 2005;430:125–31.CrossRef
23.
go back to reference Evans RP. Successful treatment of total hip and knee infection with articulating antibiotic components: a modified treatment method. Clin Orthop Relat Res. 2004;427:37–46.CrossRef Evans RP. Successful treatment of total hip and knee infection with articulating antibiotic components: a modified treatment method. Clin Orthop Relat Res. 2004;427:37–46.CrossRef
24.
go back to reference Durbhakula SM, Czajka J, Fuchs MD, Uhl RL. Antibiotic-loaded articulating cement spacer in the 2-stage exchange of infected total knee arthroplasty. J Arthroplast. 2004;19(6):768–74.CrossRef Durbhakula SM, Czajka J, Fuchs MD, Uhl RL. Antibiotic-loaded articulating cement spacer in the 2-stage exchange of infected total knee arthroplasty. J Arthroplast. 2004;19(6):768–74.CrossRef
27.
go back to reference Ha CW. A technique for intraoperative construction of antibiotic spacers. Clin Orthop Relat Res. 2006;445:204–9.PubMed Ha CW. A technique for intraoperative construction of antibiotic spacers. Clin Orthop Relat Res. 2006;445:204–9.PubMed
28.
go back to reference Pascale V, Pascale W. Custom-made Articulating Spacer in Two-stage Revision Total Knee Arthroplasty . An Early Follow-up of 14 Cases of at Least 1 Year After Surgery. HSS J. 2007;14:159–63.CrossRef Pascale V, Pascale W. Custom-made Articulating Spacer in Two-stage Revision Total Knee Arthroplasty . An Early Follow-up of 14 Cases of at Least 1 Year After Surgery. HSS J. 2007;14:159–63.CrossRef
30.
go back to reference Alt V, Bechert T, Steinrücke P, Wagener M, Seidel P, Dingeldein E, et al. An in vitro assessment of the antibacterial properties and cytotoxicity of nanoparticulate silver bone cement. Biomater. 2003;25(18):4383–91.CrossRef Alt V, Bechert T, Steinrücke P, Wagener M, Seidel P, Dingeldein E, et al. An in vitro assessment of the antibacterial properties and cytotoxicity of nanoparticulate silver bone cement. Biomater. 2003;25(18):4383–91.CrossRef
31.
32.
go back to reference Villanueva M, Ríos A, Pereiro J, Chana F, Fahandez-saddi H. Hand-made articulating spacers for infected total knee arthroplasty : a technical note hand-made articulating spacers for infected total knee arthroplasty a technical note. Acta Orthop. 2006;77(2):329–32.PubMedCrossRef Villanueva M, Ríos A, Pereiro J, Chana F, Fahandez-saddi H. Hand-made articulating spacers for infected total knee arthroplasty : a technical note hand-made articulating spacers for infected total knee arthroplasty a technical note. Acta Orthop. 2006;77(2):329–32.PubMedCrossRef
34.
go back to reference Kapandji IA. Funktionelle Anatomie der Gelenke. Schematisierte und kommentierte Zeichnungen zur menschli-chen Biomechanik. einbändige Ausgabe - obere Extremität, untere Extremität, Rumpf und Wirbelsäu-le. Thieme, Stuttgart and. N Y. 2009. Kapandji IA. Funktionelle Anatomie der Gelenke. Schematisierte und kommentierte Zeichnungen zur menschli-chen Biomechanik. einbändige Ausgabe - obere Extremität, untere Extremität, Rumpf und Wirbelsäu-le. Thieme, Stuttgart and. N Y. 2009.
36.
go back to reference Pachi A, Ji T. Frequency and velocity of people walking. Struct Eng. 2005;83:36–40. Pachi A, Ji T. Frequency and velocity of people walking. Struct Eng. 2005;83:36–40.
38.
go back to reference Novitskaya E, Zin C, Chang N, Cory E, Chen P, D’Lima D, et al. Creep of trabecular bone from the human proximal tibia. Mater Sci Eng C Mater Biol Appl. 2014;40:219–27.PubMedPubMedCentralCrossRef Novitskaya E, Zin C, Chang N, Cory E, Chen P, D’Lima D, et al. Creep of trabecular bone from the human proximal tibia. Mater Sci Eng C Mater Biol Appl. 2014;40:219–27.PubMedPubMedCentralCrossRef
40.
go back to reference Schoenfeld CM, Lautenschlager EP, Meyer PRJ. Mechanical properties of human cancellous bone in the femoral head. Med Biol Eng. 1974;12(3):313–7.PubMedCrossRef Schoenfeld CM, Lautenschlager EP, Meyer PRJ. Mechanical properties of human cancellous bone in the femoral head. Med Biol Eng. 1974;12(3):313–7.PubMedCrossRef
41.
go back to reference Kazemi M, Li L. A viscoelastic poromechanical model of the knee joint in large compression. Med Eng Phys. 2014;36.CrossRef Kazemi M, Li L. A viscoelastic poromechanical model of the knee joint in large compression. Med Eng Phys. 2014;36.CrossRef
42.
go back to reference Shrive NG, O’Connor JJ, Goodfellow JW. Load-bearing in the knee joint. Clin Orthop Relat Res. 1978;131:279–87. Shrive NG, O’Connor JJ, Goodfellow JW. Load-bearing in the knee joint. Clin Orthop Relat Res. 1978;131:279–87.
43.
go back to reference Kurosawa H, Fukubayashi T, Nakajima H. Load-bearing mode of the knee joint: physical behavior of the knee joint with or without menisci. Clin Orthop Relat Res. 1980;149:283–90. Kurosawa H, Fukubayashi T, Nakajima H. Load-bearing mode of the knee joint: physical behavior of the knee joint with or without menisci. Clin Orthop Relat Res. 1980;149:283–90.
45.
go back to reference MacAvoy MC, Ries MD. The ball and socket articulating spacer for infected total knee arthroplasty. J Arthroplast. 2005;20(6):757–62.CrossRef MacAvoy MC, Ries MD. The ball and socket articulating spacer for infected total knee arthroplasty. J Arthroplast. 2005;20(6):757–62.CrossRef
46.
go back to reference Van Thiel GS, Berend KR, Klein GR, Gordon AC, Lombardi AV, Della Valle CJ. Intraoperative molds to create an articulating spacer for the infected knee arthroplasty. Clin Orthop Relat Res. 2011;469:994–1001.PubMedCrossRef Van Thiel GS, Berend KR, Klein GR, Gordon AC, Lombardi AV, Della Valle CJ. Intraoperative molds to create an articulating spacer for the infected knee arthroplasty. Clin Orthop Relat Res. 2011;469:994–1001.PubMedCrossRef
47.
go back to reference Kalore NV, Maheshwari A, Sharma A, Cheng E, Gioe TJ. Is there a preferred articulating spacer technique for infected knee Arthroplasty ? Clin Orthop Relat Res. 2012;470:228–35.PubMedCrossRef Kalore NV, Maheshwari A, Sharma A, Cheng E, Gioe TJ. Is there a preferred articulating spacer technique for infected knee Arthroplasty ? Clin Orthop Relat Res. 2012;470:228–35.PubMedCrossRef
48.
go back to reference McPherson E. J; Lewonowski, K; Lawrence DD. Brief communication techniques in Arthroplasty use of an articulated PMMA spacer in the infected Total knee Arthroplasty. J Arthroplast. 1995;10(1):87–9.CrossRef McPherson E. J; Lewonowski, K; Lawrence DD. Brief communication techniques in Arthroplasty use of an articulated PMMA spacer in the infected Total knee Arthroplasty. J Arthroplast. 1995;10(1):87–9.CrossRef
49.
go back to reference Pitto RP, Castelli CC, Ferrari R, Munro J. Pre-formed articulating knee spacer in two-stage revision for the infected total knee arthroplasty. Int Orthop. 2005;29(5):305–8.PubMedPubMedCentralCrossRef Pitto RP, Castelli CC, Ferrari R, Munro J. Pre-formed articulating knee spacer in two-stage revision for the infected total knee arthroplasty. Int Orthop. 2005;29(5):305–8.PubMedPubMedCentralCrossRef
50.
go back to reference Villanueva-Martínez M, Ríos-Luna A, Pereiro J, Fahandez-Saddi H, Villamor A. Hand-made articulating spacers in two-stage revision for infected total knee arthroplasty: good outcome in 30 patients. Acta Orthop. 2008;79(5):674–82.PubMedCrossRef Villanueva-Martínez M, Ríos-Luna A, Pereiro J, Fahandez-Saddi H, Villamor A. Hand-made articulating spacers in two-stage revision for infected total knee arthroplasty: good outcome in 30 patients. Acta Orthop. 2008;79(5):674–82.PubMedCrossRef
52.
go back to reference Hofmann AA, Kane KR, Tkach TK, Plaster RL, Camargo MP. Treatment of infected Total knee Arthroplasty using an articulating spacer. Clin Orthop Relat Res. 1995;321:45–54. Hofmann AA, Kane KR, Tkach TK, Plaster RL, Camargo MP. Treatment of infected Total knee Arthroplasty using an articulating spacer. Clin Orthop Relat Res. 1995;321:45–54.
53.
go back to reference Jämsen E, Sheng P, Halonen P, Lehto MUK, Moilanen T, Pajamäki J, et al. Spacer prostheses in two-stage revision of infected knee arthroplasty. Int Orthop. 2006;30:257–61.PubMedPubMedCentralCrossRef Jämsen E, Sheng P, Halonen P, Lehto MUK, Moilanen T, Pajamäki J, et al. Spacer prostheses in two-stage revision of infected knee arthroplasty. Int Orthop. 2006;30:257–61.PubMedPubMedCentralCrossRef
54.
go back to reference Villa T, Carnelli D. Experimental evaluation of the biomechanical performances of a PMMA-based knee spacer. Knee. 2007;14(2):145–53.PubMedCrossRef Villa T, Carnelli D. Experimental evaluation of the biomechanical performances of a PMMA-based knee spacer. Knee. 2007;14(2):145–53.PubMedCrossRef
55.
go back to reference Fink B, Rechtenbach A, Büchner H, Vogt S, Hahn M. Articulating spacers used in two-stage revision of infected hip and knee prostheses abrade with time. Clin Orthop Relat Res. 2011;469(4):1095–102.PubMedCrossRef Fink B, Rechtenbach A, Büchner H, Vogt S, Hahn M. Articulating spacers used in two-stage revision of infected hip and knee prostheses abrade with time. Clin Orthop Relat Res. 2011;469(4):1095–102.PubMedCrossRef
56.
go back to reference Hsu YC, Cheng HC, Ng TP, Chiu KY. Antibiotic-loaded cement articulating spacer for 2-stage Reimplantation in infected Total knee Arthroplasty a simple and economic method. J Arthroplast. 2007;22(7):1060–6.CrossRef Hsu YC, Cheng HC, Ng TP, Chiu KY. Antibiotic-loaded cement articulating spacer for 2-stage Reimplantation in infected Total knee Arthroplasty a simple and economic method. J Arthroplast. 2007;22(7):1060–6.CrossRef
Metadata
Title
Loading capacity of dynamic knee spacers: a comparison between hand-moulded and COPAL spacers
Publication date
01-12-2019
Published in
BMC Musculoskeletal Disorders / Issue 1/2019
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-019-2982-5

Other articles of this Issue 1/2019

BMC Musculoskeletal Disorders 1/2019 Go to the issue