Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2019

Open Access 01-12-2019 | Research article

Impact of a double-layer cementing technique on the homogeneity of cementation and the generation of loose bone cement fragments in tibial unicompartmental knee arthroplasty

Authors: Christian B. Scheele, Matthias F. Pietschmann, Christian Schröder, Christian Suren, Thomas M. Grupp, Peter E. Müller

Published in: BMC Musculoskeletal Disorders | Issue 1/2019

Login to get access

Abstract

Background

The objective of this study was to evaluate the impact of a single- vs. double-layer cementing technique on morphological cementation and the generation of microscopic cement layers or loose cement fragments in unicompartmental knee arthroplasty (UKA).

Methods

UKAs were implanted in 12 cadaver knees. The specimens were divided into two groups of comparable bone mineral density. Six UKAs were implanted using a single-layer cementing technique (group A) and six UKAs were implanted using a double-layer cementing technique (group B). Morphological cementation was assessed on nine cuts through the implant–cement–bone interface in the frontal plane. Loose bone cement fragments and the microscopically quality of layer formation were evaluated.

Results

Contact between bone and prosthesis was observed in 45.4% of interfaces in group A and 27.8% in group B (p = 0.126). The significant increase of areas without visible cement interlocking in the anteroposterior direction in group A (p = 0.005) was not evident in group B (p = 0.262). Penetration around the peg tended to occur more frequently in group B (67.5% vs. 90.6% p = 0.091). Scanning electron microscopy identified no evidence of fissure formations within the bilaminar cement mantle. Free bone cement fragments were documented in 66.7% in both groups with no difference concerning mass (p = 1.0).

Conclusions

This in-vitro study showed a tendency towards a more homogenous cementation of tibial UKAs using a double-layer cementing technique, although most of the differences did not reach the level of significance. However, theoretical downsides of the double-layer cementing technique such as an increased formation of free bone fragments or a microscopically fissure formation within the cement layer could not be detected either.
Literature
1.
go back to reference Berger RA, Meneghini RM, Sheinkop MB, Della Valle CJ, Jacobs JJ, Rosenberg AG, Galante JO. The progression of patellofemoral arthrosis after medial unicompartmental replacement: results at 11 to 15 years. Clin Orthop Relat Res. 2004;428:92–9.CrossRef Berger RA, Meneghini RM, Sheinkop MB, Della Valle CJ, Jacobs JJ, Rosenberg AG, Galante JO. The progression of patellofemoral arthrosis after medial unicompartmental replacement: results at 11 to 15 years. Clin Orthop Relat Res. 2004;428:92–9.CrossRef
2.
go back to reference Price AJ, Svard U. A second decade lifetable survival analysis of the Oxford unicompartmental knee arthroplasty. Clin Orthop Relat Res. 2011;469(1):174–9.CrossRef Price AJ, Svard U. A second decade lifetable survival analysis of the Oxford unicompartmental knee arthroplasty. Clin Orthop Relat Res. 2011;469(1):174–9.CrossRef
3.
go back to reference Laurencin CT, Zelicof SB, Scott RD, Ewald FC. Unicompartmental versus total knee arthroplasty in the same patient. A comparative study. Clin Orthop Relat Res. 1991;273:151–6. Laurencin CT, Zelicof SB, Scott RD, Ewald FC. Unicompartmental versus total knee arthroplasty in the same patient. A comparative study. Clin Orthop Relat Res. 1991;273:151–6.
4.
go back to reference Rougraff BT, Heck DA, Gibson AE. A comparison of tricompartmental and unicompartmental arthroplasty for the treatment of gonarthrosis. Clin Orthop Relat Res. 1991;273:157–64. Rougraff BT, Heck DA, Gibson AE. A comparison of tricompartmental and unicompartmental arthroplasty for the treatment of gonarthrosis. Clin Orthop Relat Res. 1991;273:157–64.
5.
go back to reference Newman J, Pydisetty RV, Ackroyd C. Unicompartmental or total knee replacement: the 15-year results of a prospective randomised controlled trial. J Bone Joint Surg Br. 2009;91(1):52–7.CrossRef Newman J, Pydisetty RV, Ackroyd C. Unicompartmental or total knee replacement: the 15-year results of a prospective randomised controlled trial. J Bone Joint Surg Br. 2009;91(1):52–7.CrossRef
6.
go back to reference Paxton EW, Inacio MC, Khatod M, Yue EJ, Namba RS. Kaiser Permanente National Total Joint Replacement Registry: aligning operations with information technology. Clin Orthop Relat Res. 2010;468(10):2646–63.CrossRef Paxton EW, Inacio MC, Khatod M, Yue EJ, Namba RS. Kaiser Permanente National Total Joint Replacement Registry: aligning operations with information technology. Clin Orthop Relat Res. 2010;468(10):2646–63.CrossRef
7.
go back to reference SKAR: (Swedish Knee Arthroplasty Register) Annual report 2012. Lund University Hospital, Lund 2012 Available online at wwwkneese/ 2012. SKAR: (Swedish Knee Arthroplasty Register) Annual report 2012. Lund University Hospital, Lund 2012 Available online at wwwkneese/ 2012.
8.
go back to reference Epinette JA, Brunschweiler B, Mertl P, Mole D, Cazenave A, French Society for H, knee. Unicompartmental knee arthroplasty modes of failure: wear is not the main reason for failure: a multicentre study of 418 failed knees. Orthop Traumatol Surg Res. 2012;98(6 Suppl):S124–30.CrossRef Epinette JA, Brunschweiler B, Mertl P, Mole D, Cazenave A, French Society for H, knee. Unicompartmental knee arthroplasty modes of failure: wear is not the main reason for failure: a multicentre study of 418 failed knees. Orthop Traumatol Surg Res. 2012;98(6 Suppl):S124–30.CrossRef
9.
go back to reference Schlegel UJ, Siewe J, Delank KS, Eysel P, Puschel K, Morlock MM, de Uhlenbrock AG. Pulsed lavage improves fixation strength of cemented tibial components. Int Orthop. 2011;35(8):1165–9.CrossRef Schlegel UJ, Siewe J, Delank KS, Eysel P, Puschel K, Morlock MM, de Uhlenbrock AG. Pulsed lavage improves fixation strength of cemented tibial components. Int Orthop. 2011;35(8):1165–9.CrossRef
10.
go back to reference Krause WR, Krug W, Miller J. Strength of the cement-bone interface. Clin Orthop Relat Res. 1982;163:290–9. Krause WR, Krug W, Miller J. Strength of the cement-bone interface. Clin Orthop Relat Res. 1982;163:290–9.
11.
go back to reference Halawa M, Lee AJ, Ling RS, Vangala SS. The shear strength of trabecular bone from the femur, and some factors affecting the shear strength of the cement-bone interface. Arch Orthop Trauma Surg. 1978;92(1):19–30.CrossRef Halawa M, Lee AJ, Ling RS, Vangala SS. The shear strength of trabecular bone from the femur, and some factors affecting the shear strength of the cement-bone interface. Arch Orthop Trauma Surg. 1978;92(1):19–30.CrossRef
12.
go back to reference MacDonald W, Swarts E, Beaver R. Penetration and shear strength of cement-bone interfaces in vivo. Clin Orthop Relat Res. 1993;286:283–8. MacDonald W, Swarts E, Beaver R. Penetration and shear strength of cement-bone interfaces in vivo. Clin Orthop Relat Res. 1993;286:283–8.
13.
go back to reference Scheele C, Pietschmann MF, Schroder C, Grupp T, Holderied M, Jansson V, Muller PE. Effect of minimally-invasive implantation of unicompartmental knee arthroplasty on cement penetration and biomechanical stability. An experimental study in human tibiae. Clin Biomech (Bristol, Avon). 2018;51:34–9.CrossRef Scheele C, Pietschmann MF, Schroder C, Grupp T, Holderied M, Jansson V, Muller PE. Effect of minimally-invasive implantation of unicompartmental knee arthroplasty on cement penetration and biomechanical stability. An experimental study in human tibiae. Clin Biomech (Bristol, Avon). 2018;51:34–9.CrossRef
14.
go back to reference Scheele C, Pietschmann MF, Schroder C, Grupp T, Holderied M, Jansson V, Muller PE. Effect of lavage and brush preparation on cement penetration and primary stability in tibial unicompartmental total knee arthroplasty: an experimental cadaver study. Knee. 2017;24(2):402–8.CrossRef Scheele C, Pietschmann MF, Schroder C, Grupp T, Holderied M, Jansson V, Muller PE. Effect of lavage and brush preparation on cement penetration and primary stability in tibial unicompartmental total knee arthroplasty: an experimental cadaver study. Knee. 2017;24(2):402–8.CrossRef
15.
go back to reference Scheele CB, Muller PE, Schroder C, Grupp T, Jansson V, Pietschmann MF. Accuracy of a non-invasive CT-based measuring technique for cement penetration depth in human tibial UKA. BMC Med Imaging. 2019;19(1):9.CrossRef Scheele CB, Muller PE, Schroder C, Grupp T, Jansson V, Pietschmann MF. Accuracy of a non-invasive CT-based measuring technique for cement penetration depth in human tibial UKA. BMC Med Imaging. 2019;19(1):9.CrossRef
16.
go back to reference Clarius M, Hauck C, Seeger JB, James A, Murray DW, Aldinger PR. Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplasty: pulsed lavage versus syringe lavage. Int Orthop. 2009;33(6):1585–90.CrossRef Clarius M, Hauck C, Seeger JB, James A, Murray DW, Aldinger PR. Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplasty: pulsed lavage versus syringe lavage. Int Orthop. 2009;33(6):1585–90.CrossRef
17.
go back to reference Maistrelli GL, Antonelli L, Fornasier V, Mahomed N. Cement penetration with pulsed lavage versus syringe irrigation in total knee arthroplasty. Clin Orthop Relat Res. 1995;312:261–5. Maistrelli GL, Antonelli L, Fornasier V, Mahomed N. Cement penetration with pulsed lavage versus syringe irrigation in total knee arthroplasty. Clin Orthop Relat Res. 1995;312:261–5.
18.
go back to reference Clarius M, Mohr G, Jaeger S, Seeger JB, Bitsch RG. Femoral fixation pattern in cemented Oxford unicompartmental knee arthroplasty--an experimental cadaver study. Knee. 2010;17(6):398–402.CrossRef Clarius M, Mohr G, Jaeger S, Seeger JB, Bitsch RG. Femoral fixation pattern in cemented Oxford unicompartmental knee arthroplasty--an experimental cadaver study. Knee. 2010;17(6):398–402.CrossRef
19.
go back to reference Vanlommel J, Luyckx JP, Labey L, Innocenti B, De Corte R, Bellemans J. Cementing the tibial component in total knee arthroplasty: which technique is the best? J Arthroplast. 2011;26(3):492–6.CrossRef Vanlommel J, Luyckx JP, Labey L, Innocenti B, De Corte R, Bellemans J. Cementing the tibial component in total knee arthroplasty: which technique is the best? J Arthroplast. 2011;26(3):492–6.CrossRef
20.
go back to reference Hauptmann SM, Weber P, Glaser C, Birkenmaier C, Jansson V, Muller PE. Free bone cement fragments after minimally invasive unicompartmental knee arthroplasty: an underappreciated problem. Knee Surg Sports Traumatol Arthrosc. 2008;16(8):770–5.CrossRef Hauptmann SM, Weber P, Glaser C, Birkenmaier C, Jansson V, Muller PE. Free bone cement fragments after minimally invasive unicompartmental knee arthroplasty: an underappreciated problem. Knee Surg Sports Traumatol Arthrosc. 2008;16(8):770–5.CrossRef
21.
go back to reference Grupp TM, Pietschmann MF, Holderied M, Scheele C, Schroder C, Jansson V, Muller PE. Primary stability of unicompartmental knee arthroplasty under dynamic compression-shear loading in human tibiae. Clin Biomech (Bristol, Avon). 2013;28(9–10):1006–13.CrossRef Grupp TM, Pietschmann MF, Holderied M, Scheele C, Schroder C, Jansson V, Muller PE. Primary stability of unicompartmental knee arthroplasty under dynamic compression-shear loading in human tibiae. Clin Biomech (Bristol, Avon). 2013;28(9–10):1006–13.CrossRef
22.
go back to reference Walker PS, Soudry M, Ewald FC, McVickar H. Control of cement penetration in total knee arthroplasty. Clin Orthop Relat Res. 1984;185:155–64. Walker PS, Soudry M, Ewald FC, McVickar H. Control of cement penetration in total knee arthroplasty. Clin Orthop Relat Res. 1984;185:155–64.
23.
go back to reference Labutti RS, Bayers-Thering M, Krackow KA. Enhancing femoral cement fixation in total knee arthroplasty. J Arthroplast. 2003;18(8):979–83.CrossRef Labutti RS, Bayers-Thering M, Krackow KA. Enhancing femoral cement fixation in total knee arthroplasty. J Arthroplast. 2003;18(8):979–83.CrossRef
24.
go back to reference Li PL, Ingle PJ, Dowell JK. Cement-within-cement revision hip arthroplasty; should it be done? J Bone Joint Surg Br. 1996;78(5):809–11.CrossRef Li PL, Ingle PJ, Dowell JK. Cement-within-cement revision hip arthroplasty; should it be done? J Bone Joint Surg Br. 1996;78(5):809–11.CrossRef
25.
go back to reference Weinrauch PC, Bell C, Wilson L, Goss B, Lutton C, Crawford RW. Shear properties of bilaminar polymethylmethacrylate cement mantles in revision hip joint arthroplasty. J Arthroplast. 2007;22(3):394–403.CrossRef Weinrauch PC, Bell C, Wilson L, Goss B, Lutton C, Crawford RW. Shear properties of bilaminar polymethylmethacrylate cement mantles in revision hip joint arthroplasty. J Arthroplast. 2007;22(3):394–403.CrossRef
26.
go back to reference Wilson LJ, Bell CG, Weinrauch P, Crawford R. In vitro cyclic testing of the Exeter stem after cement within cement revision. J Arthroplast. 2009;24(5):789–94.CrossRef Wilson LJ, Bell CG, Weinrauch P, Crawford R. In vitro cyclic testing of the Exeter stem after cement within cement revision. J Arthroplast. 2009;24(5):789–94.CrossRef
27.
go back to reference Ishihara S, McEvily AJ, Goshima T, Kanekasu K, Nara T. On fatigue lifetimes and fatigue crack growth behavior of bone cement. J Mater Sci Mater Med. 2000;11(10):661–6.CrossRef Ishihara S, McEvily AJ, Goshima T, Kanekasu K, Nara T. On fatigue lifetimes and fatigue crack growth behavior of bone cement. J Mater Sci Mater Med. 2000;11(10):661–6.CrossRef
28.
go back to reference Kim WY, Shafi M, Kim YY, Kim JY, Cho YK, Han CW. Posteromedial compartment cement extrusion after unicompartmental knee arthroplasty treated by arthroscopy: a case report. Knee Surg Sports Traumatol Arthrosc. 2006;14(1):46–9.CrossRef Kim WY, Shafi M, Kim YY, Kim JY, Cho YK, Han CW. Posteromedial compartment cement extrusion after unicompartmental knee arthroplasty treated by arthroscopy: a case report. Knee Surg Sports Traumatol Arthrosc. 2006;14(1):46–9.CrossRef
29.
go back to reference Banwart JC, McQueen DA, Friis EA, Graber CD. Negative pressure intrusion cementing technique for total knee arthroplasty. J Arthroplast. 2000;15(3):360–7.CrossRef Banwart JC, McQueen DA, Friis EA, Graber CD. Negative pressure intrusion cementing technique for total knee arthroplasty. J Arthroplast. 2000;15(3):360–7.CrossRef
30.
go back to reference Willert HG, Ludwig J, Semlitsch M. Reaction of bone to methacrylate after hip arthroplasty: a long-term gross, light microscopic, and scanning electron microscopic study. J Bone Joint Surg Am. 1974;56(7):1368–82.CrossRef Willert HG, Ludwig J, Semlitsch M. Reaction of bone to methacrylate after hip arthroplasty: a long-term gross, light microscopic, and scanning electron microscopic study. J Bone Joint Surg Am. 1974;56(7):1368–82.CrossRef
31.
go back to reference Elmadag M, Imren Y, Erdil M, Bilsel K, Tuncay I. Excess retained cement in the posteromedial compartment after unicondylar knee arthroplasty. Acta Orthop Traumatol Turc. 2013;47(4):291–4.CrossRef Elmadag M, Imren Y, Erdil M, Bilsel K, Tuncay I. Excess retained cement in the posteromedial compartment after unicondylar knee arthroplasty. Acta Orthop Traumatol Turc. 2013;47(4):291–4.CrossRef
32.
go back to reference Bhutta MA, Doorgakant A, Marynissen H. Tibial nerve impingement secondary to posterior cement extrusion after unicompartmental knee arthroplasty. J Arthroplast. 2010;25(7):1168 e1117–1168.CrossRef Bhutta MA, Doorgakant A, Marynissen H. Tibial nerve impingement secondary to posterior cement extrusion after unicompartmental knee arthroplasty. J Arthroplast. 2010;25(7):1168 e1117–1168.CrossRef
33.
go back to reference Howe DJ, Taunton OD Jr, Engh GA. Retained cement after unicondylar knee arthroplasty. A report of four cases. J Bone Joint Surg Am. 2004;86-A(10):2283–6.CrossRef Howe DJ, Taunton OD Jr, Engh GA. Retained cement after unicondylar knee arthroplasty. A report of four cases. J Bone Joint Surg Am. 2004;86-A(10):2283–6.CrossRef
34.
go back to reference Karataglis D, Agathangelidis F, Papadopoulos P, Petsatodis G, Christodoulou A. Arthroscopic removal of impinging cement after unicompartmental knee arthroplasty. Hippokratia. 2012;16(1):76–9.PubMedPubMedCentral Karataglis D, Agathangelidis F, Papadopoulos P, Petsatodis G, Christodoulou A. Arthroscopic removal of impinging cement after unicompartmental knee arthroplasty. Hippokratia. 2012;16(1):76–9.PubMedPubMedCentral
35.
go back to reference Benjamin JB, Gie GA, Lee AJ, Ling RS, Volz RG. Cementing technique and the effects of bleeding. J Bone Joint Surg Br. 1987;69(4):620–4.CrossRef Benjamin JB, Gie GA, Lee AJ, Ling RS, Volz RG. Cementing technique and the effects of bleeding. J Bone Joint Surg Br. 1987;69(4):620–4.CrossRef
36.
go back to reference Majkowski RS, Miles AW, Bannister GC, Perkins J, Taylor GJ. Bone surface preparation in cemented joint replacement. J Bone Joint Surg Br. 1993;75(3):459–63.CrossRef Majkowski RS, Miles AW, Bannister GC, Perkins J, Taylor GJ. Bone surface preparation in cemented joint replacement. J Bone Joint Surg Br. 1993;75(3):459–63.CrossRef
37.
go back to reference Greenwald AS, Narten NC, Wilde AH. Points in the technique of recementing in the revision of an implant arthroplasty. J Bone Joint Surg Br. 1978;60(1):107–10.CrossRef Greenwald AS, Narten NC, Wilde AH. Points in the technique of recementing in the revision of an implant arthroplasty. J Bone Joint Surg Br. 1978;60(1):107–10.CrossRef
38.
go back to reference Rudol G, Wilcox R, Jin Z, Tsiridis E. The effect of surface finish and interstitial fluid on the cement-in-cement interface in revision surgery of the hip. J Bone Joint Surg Br. 2011;93(2):188–93.CrossRef Rudol G, Wilcox R, Jin Z, Tsiridis E. The effect of surface finish and interstitial fluid on the cement-in-cement interface in revision surgery of the hip. J Bone Joint Surg Br. 2011;93(2):188–93.CrossRef
Metadata
Title
Impact of a double-layer cementing technique on the homogeneity of cementation and the generation of loose bone cement fragments in tibial unicompartmental knee arthroplasty
Authors
Christian B. Scheele
Matthias F. Pietschmann
Christian Schröder
Christian Suren
Thomas M. Grupp
Peter E. Müller
Publication date
01-12-2019
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2019
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-019-2929-x

Other articles of this Issue 1/2019

BMC Musculoskeletal Disorders 1/2019 Go to the issue