Abstract

Background

Sonication is a valuable tool in the diagnosis of periprosthetic joint infections (PJI). However, conditions and definition criteria for PJI vary among studies. The aim of this study was to determine the diagnostic performance (i.e., specificity, sensitivity) of sonicate fluid culture (SFC) against periprosthetic tissue culture (PTC), when using European Bone and Joint Infection Society (EBJIS) criteria.

Methods

From March 2017 to April 2018, 257 implants were submitted for sonication. PJI was defined according to the EBJIS criteria as well as according to the International Consensus Meeting criteria of 2018 (ICM 2018). Only cases with at least one corresponding tissue sample were included. Samples were cultured using traditional microbiological plating techniques. Sensitivity and specificity were determined using two-by-two contingency tables. McNemar’s test was used to compare proportions among paired samples. Subgroup analysis was performed dividing the cohort according to the site of PJI, previous antibiotic treatment, and time of manifestation. Prevalence of pathogens was determined for all patients as well as for specific subgroups.

Results

Among the 257 cases, 145 and 112 were defined as PJI and aseptic failure, respectively. When using the EBJIS criteria, the sensitivity of SFC and PTC was 69.0 and 62.8%, respectively (p = .04). Meanwhile, the specificity was 90.2 and 92.9%, respectively (p = .65). When adopting ICM 2018 criteria, the sensitivity of SFC and PTC was 87.5 and 84.4% (p = .63) respectively, while the specificity was 85.1 and 92.5% (p = .05), respectively. The most commonly identified pathogens were coagulase-negative staphylococci (26% overall), while 31% of PJI were culture-negative and 9% polymicrobial.

Conclusions

SFC exhibited significantly greater sensitivity versus PTC when using the EBJIS criteria. Nevertheless, the diagnosis of PJI remains a difficult challenge and different diagnostic tools are necessary to optimize the outcome.
Literature
1.
go back to reference Zimmerli W, Trampuz A, Ochsner PE. Prosthetic-joint infections. N Engl J Med. 2004;351(16):1645–54.CrossRef Zimmerli W, Trampuz A, Ochsner PE. Prosthetic-joint infections. N Engl J Med. 2004;351(16):1645–54.CrossRef
2.
go back to reference Fernández-Sampedro M, Fariñas-Alvarez C, Garces-Zarzalejo C, et al. Accuracy of different diagnostic tests for early, delayed and late prosthetic joint infection. BMC Infect Dis. 2017;17(1):592.CrossRef Fernández-Sampedro M, Fariñas-Alvarez C, Garces-Zarzalejo C, et al. Accuracy of different diagnostic tests for early, delayed and late prosthetic joint infection. BMC Infect Dis. 2017;17(1):592.CrossRef
3.
go back to reference Parvizi J, Zmistowski B, Berbari EF, et al. New definition for periprosthetic joint infection. From the workgroup of the musculoskeletal infection society. Clin Orthop Relat Res. 2011;469(11):2992–4.CrossRef Parvizi J, Zmistowski B, Berbari EF, et al. New definition for periprosthetic joint infection. From the workgroup of the musculoskeletal infection society. Clin Orthop Relat Res. 2011;469(11):2992–4.CrossRef
4.
go back to reference Parvizi J, Gehrke T, Chen AF. Proceedings of the international consensus on Periprosthetic joint infection. Bone Joint J. 2013;95-B(11):1450–2.CrossRef Parvizi J, Gehrke T, Chen AF. Proceedings of the international consensus on Periprosthetic joint infection. Bone Joint J. 2013;95-B(11):1450–2.CrossRef
5.
go back to reference Parvizi J, Tan TL, Goswami K, et al. The 2018 definition of Periprosthetic hip and knee infection. An evidence-based and validated criteria. J Arthroplast. 2018;93(5):1309–14.CrossRef Parvizi J, Tan TL, Goswami K, et al. The 2018 definition of Periprosthetic hip and knee infection. An evidence-based and validated criteria. J Arthroplast. 2018;93(5):1309–14.CrossRef
6.
go back to reference Corvec S, Portillo ME, Pasticci BM, Borens O, Trampuz A. Epidemiology and new developments in the diagnosis of prosthetic joint infection. Int J Artif Organs. 2012;35(10):923–34.CrossRef Corvec S, Portillo ME, Pasticci BM, Borens O, Trampuz A. Epidemiology and new developments in the diagnosis of prosthetic joint infection. Int J Artif Organs. 2012;35(10):923–34.CrossRef
7.
go back to reference Ochsner PE, Swiss Orthopaedics, Swiss Society for Infectious Diseases. Infections of the musculoskeletal system – basic principles, prevention, diagnosis and treatment. 1st ed. Grandveaux: Swiss Orthopaedics; 2014. Ochsner PE, Swiss Orthopaedics, Swiss Society for Infectious Diseases. Infections of the musculoskeletal system – basic principles, prevention, diagnosis and treatment. 1st ed. Grandveaux: Swiss Orthopaedics; 2014.
8.
go back to reference Spangehl MJ, Masri BA, O'Connell JX, Duncan CP. Prospective analysis of preoperative and intraoperative investigations for the diagnosis of infection at the sites of two hundred and two revision total hip arthroplasties. J Bone Joint Surg Am. 1999;81(5):672–83.CrossRef Spangehl MJ, Masri BA, O'Connell JX, Duncan CP. Prospective analysis of preoperative and intraoperative investigations for the diagnosis of infection at the sites of two hundred and two revision total hip arthroplasties. J Bone Joint Surg Am. 1999;81(5):672–83.CrossRef
9.
go back to reference Baré J, MacDonald SJ, Bourne RB. Preoperative evaluations in revision total knee arthroplasty. Clin Orthop Relat Res. 2006;446:40–4.CrossRef Baré J, MacDonald SJ, Bourne RB. Preoperative evaluations in revision total knee arthroplasty. Clin Orthop Relat Res. 2006;446:40–4.CrossRef
10.
go back to reference Rothenberg AC, Wilson AE, Hayes JP, O'Malley MJ, Klatt BA. Sonication of Arthroplasty implants improves accuracy of Periprosthetic joint infection cultures. Clin Orthop Relat Res. 2017;475(7):1827–36.CrossRef Rothenberg AC, Wilson AE, Hayes JP, O'Malley MJ, Klatt BA. Sonication of Arthroplasty implants improves accuracy of Periprosthetic joint infection cultures. Clin Orthop Relat Res. 2017;475(7):1827–36.CrossRef
11.
go back to reference Morawietz L, Classen RA, Schröder JH, et al. Proposal for a histopathological consensus classification of the periprosthetic interface membrane. J Clin Pathol. 2006;59(6):591–7.CrossRef Morawietz L, Classen RA, Schröder JH, et al. Proposal for a histopathological consensus classification of the periprosthetic interface membrane. J Clin Pathol. 2006;59(6):591–7.CrossRef
12.
go back to reference Liu H, Zhang Y, Li L, Zou HC. The application of sonication in diagnosis of periprosthetic joint infection. Eur J Clin Microbiol Infect Dis. 2017;36(1):1–9.CrossRef Liu H, Zhang Y, Li L, Zou HC. The application of sonication in diagnosis of periprosthetic joint infection. Eur J Clin Microbiol Infect Dis. 2017;36(1):1–9.CrossRef
13.
go back to reference Costerton JW, Montanaro L, Arciola CR. Biofilm in implant infections. Its production and regulation. Int J Artif Organs. 2005;28(11):1062–8.CrossRef Costerton JW, Montanaro L, Arciola CR. Biofilm in implant infections. Its production and regulation. Int J Artif Organs. 2005;28(11):1062–8.CrossRef
14.
go back to reference Trampuz A, Piper KE, Jacobson MJ, et al. Sonication of removed hip and knee prostheses for diagnosis of infection. N Engl J Med. 2007;357(7):654–63.CrossRef Trampuz A, Piper KE, Jacobson MJ, et al. Sonication of removed hip and knee prostheses for diagnosis of infection. N Engl J Med. 2007;357(7):654–63.CrossRef
15.
go back to reference Renz N, Cabric S, Janz V, Trampuz A. Sonication in the diagnosis of periprosthetic infections: significance and practical implementation. Orthopade. 2015;44(12):942–5.CrossRef Renz N, Cabric S, Janz V, Trampuz A. Sonication in the diagnosis of periprosthetic infections: significance and practical implementation. Orthopade. 2015;44(12):942–5.CrossRef
16.
go back to reference Zhai Z, Li H, Qin A, et al. Meta-analysis of sonication fluid samples from prosthetic components for diagnosis of infection after total joint arthroplasty. J Clin Microbiol. 2014;52(5):1730–6.CrossRef Zhai Z, Li H, Qin A, et al. Meta-analysis of sonication fluid samples from prosthetic components for diagnosis of infection after total joint arthroplasty. J Clin Microbiol. 2014;52(5):1730–6.CrossRef
17.
go back to reference Li C, Renz N, Trampuz A. Management of Periprosthetic Joint Infection. Hip Pelvis. 2018;30(3):138–46.CrossRef Li C, Renz N, Trampuz A. Management of Periprosthetic Joint Infection. Hip Pelvis. 2018;30(3):138–46.CrossRef
18.
go back to reference Renz N, Yermak K, Perka C, Trampuz A. Alpha Defensin lateral flow test for diagnosis of Periprosthetic joint infection. Not a screening but a confirmatory test. J Bone Joint Surg Am. 2018;100(9):742–50.CrossRef Renz N, Yermak K, Perka C, Trampuz A. Alpha Defensin lateral flow test for diagnosis of Periprosthetic joint infection. Not a screening but a confirmatory test. J Bone Joint Surg Am. 2018;100(9):742–50.CrossRef
19.
go back to reference Prieto-Borja L, Auñón Á, Blanco A, et al. Evaluation of the use of sonication of retrieved implants for the diagnosis of prosthetic joint infection in a routine setting. Eur J Clin Microbiol Infect Dis. 2018;37(4):715–22.CrossRef Prieto-Borja L, Auñón Á, Blanco A, et al. Evaluation of the use of sonication of retrieved implants for the diagnosis of prosthetic joint infection in a routine setting. Eur J Clin Microbiol Infect Dis. 2018;37(4):715–22.CrossRef
20.
go back to reference Ueda N, Oe K, Nakamura T, et al. Sonication of extracted implants improves microbial detection in patients with orthopedic implant-associated infections. J Arthroplast. 2019;34(6):1189–96.CrossRef Ueda N, Oe K, Nakamura T, et al. Sonication of extracted implants improves microbial detection in patients with orthopedic implant-associated infections. J Arthroplast. 2019;34(6):1189–96.CrossRef
21.
go back to reference van Diek FM, Albers CGM, van Hooff ML, Meis JF, Goosen JHM. Low sensitivity of implant sonication when screening for infection in revision surgery. Acta Orthop. 2017;88(3):294–9.CrossRef van Diek FM, Albers CGM, van Hooff ML, Meis JF, Goosen JHM. Low sensitivity of implant sonication when screening for infection in revision surgery. Acta Orthop. 2017;88(3):294–9.CrossRef
22.
go back to reference Dudareva M, Barrett L, Figtree M, et al. Sonication versus Tissue Sampling for Diagnosis of Prosthetic Joint and Other Orthopedic Device-Related Infections. J Clin Microbiol. 2018;56(12):00688-18(1-12). Dudareva M, Barrett L, Figtree M, et al. Sonication versus Tissue Sampling for Diagnosis of Prosthetic Joint and Other Orthopedic Device-Related Infections. J Clin Microbiol. 2018;56(12):00688-18(1-12).
23.
go back to reference Tani S, Lepetsos P, Stylianakis A, et al. Superiority of the sonication method against conventional periprosthetic tissue cultures for diagnosis of prosthetic joint infections. Eur J Orthop Surg Traumatol. 2018;28(1):51–7.CrossRef Tani S, Lepetsos P, Stylianakis A, et al. Superiority of the sonication method against conventional periprosthetic tissue cultures for diagnosis of prosthetic joint infections. Eur J Orthop Surg Traumatol. 2018;28(1):51–7.CrossRef
24.
go back to reference Sampedro MF, Huddleston PM, Piper KE, et al. A biofilm approach to detect bacteria on removed spinal implants. Spine. 2010;35(12):1218–24.CrossRef Sampedro MF, Huddleston PM, Piper KE, et al. A biofilm approach to detect bacteria on removed spinal implants. Spine. 2010;35(12):1218–24.CrossRef
25.
go back to reference Scorzolini L, Lichtner M, Iannetta M, et al. Sonication technique improves microbiological diagnosis in patients treated with antibiotics before surgery for prosthetic joint infections. New Microbiol. 2014;37(3):321–811.PubMed Scorzolini L, Lichtner M, Iannetta M, et al. Sonication technique improves microbiological diagnosis in patients treated with antibiotics before surgery for prosthetic joint infections. New Microbiol. 2014;37(3):321–811.PubMed
26.
go back to reference Puig-Verdie L, Alentorn-Geli E, Gonzalez-Cuevas A, et al. Implant sonication increases the diagnostic accuracy of infection in patients with delayed, but not early, orthopaedic implant failure. Bone Joint J. 2013;95-B(2):244–9.CrossRef Puig-Verdie L, Alentorn-Geli E, Gonzalez-Cuevas A, et al. Implant sonication increases the diagnostic accuracy of infection in patients with delayed, but not early, orthopaedic implant failure. Bone Joint J. 2013;95-B(2):244–9.CrossRef
27.
go back to reference Del Pozo JL, Patel R. Clinical practice. Infection associated with prosthetic joints. N Engl J Med. 2009;361(8):787–94.CrossRef Del Pozo JL, Patel R. Clinical practice. Infection associated with prosthetic joints. N Engl J Med. 2009;361(8):787–94.CrossRef
28.
go back to reference Drago L, de Vecchi E, Bortolin M, et al. Epidemiology and antibiotic resistance of late prosthetic knee and hip infections. J Arthroplast. 2017;32(8):2496–500.CrossRef Drago L, de Vecchi E, Bortolin M, et al. Epidemiology and antibiotic resistance of late prosthetic knee and hip infections. J Arthroplast. 2017;32(8):2496–500.CrossRef
29.
go back to reference Zeller V, Kerroumi Y, Meyssonnier V, et al. Analysis of postoperative and hematogenous prosthetic joint-infection microbiological patterns in a large cohort. J Inf Secur. 2018;76(4):328–34. Zeller V, Kerroumi Y, Meyssonnier V, et al. Analysis of postoperative and hematogenous prosthetic joint-infection microbiological patterns in a large cohort. J Inf Secur. 2018;76(4):328–34.
30.
go back to reference Reisener M, Perka C. Do culture-negative Periprosthetic joint infections have a worse outcome than culture-positive Periprosthetic joint infections? A Systematic Review and Meta-Analysis. Biomed Res Int. 2018. Reisener M, Perka C. Do culture-negative Periprosthetic joint infections have a worse outcome than culture-positive Periprosthetic joint infections? A Systematic Review and Meta-Analysis. Biomed Res Int. 2018.
31.
go back to reference Tande AJ, Patel R. Prosthetic joint infection. Clin Microbiol Rev. 2018;6278012:1-12. Tande AJ, Patel R. Prosthetic joint infection. Clin Microbiol Rev. 2018;6278012:1-12.
Metadata
Title
Sonication of retrieved implants improves sensitivity in the diagnosis of periprosthetic joint infection
Authors
Petri Bellova
Veronika Knop-Hammad
Matthias Königshausen
Eileen Mempel
Sven Frieler
Jan Gessmann
Thomas A. Schildhauer
Hinnerk Baecker
Publication date
01-12-2019
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2019
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-019-3006-1

Other articles of this Issue 1/2019

BMC Musculoskeletal Disorders 1/2019 Go to the issue