Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2019

Open Access 01-12-2019 | Ultrasound | Research article

The relationship of the shear wave elastography findings of patients with unilateral lumbar disc herniation and clinical characteristics

Authors: Qingyuan Wang, Hao Zhang, Jinxin Zhang, Hanqi Zhang, Hui Zheng

Published in: BMC Musculoskeletal Disorders | Issue 1/2019

Login to get access

Abstract

Background

The aim of this study was to find out whether the shear wave elastography (SWE) findings of patients with unilateral lumbar disc herniation (LDH) were related to clinical characteristics.

Methods

For this purpose, the study group included patients (N = 20; 13 male, 7 female) with complaints of unilateral sciatica, with foraminal stenosis caused by one level of LDH (L4-L5 or L5-S1). An gender-and age-matched control group (N = 27; 16 male, 11 female) was included. All the patients were examined on both the axial and longitudinal planes bilaterally at the same level using a convex array probe (1- 6 MHz, Supersonic Imagine, Aix en Provence, France).

Results

The sciatic nerve stiffness measured on longitudinal planes of the affected side was significantly higher than unaffected side (p < 0.001) and the control group (P < 0.05). Furthermore, the symptom duration of unilateral LDH is positively correlated with the stiffness the sciatic nerve (r = 0.52, p = 0.019).

Conclusion

According to these findings, ultrasound imaging can be considered as a useful tool to detect changes in the sciatic nerve due to disc herniation. This technique will have a promising prospect for many patients with unilateral LDH in monitoring stiffness during rehabilitation and before or after surgery.
Literature
6.
go back to reference Inal M, Tan S, Yumusak EM, MH S¸a, Alpua M, Ornek K. Evaluation of the optic nerve using strain and shear wave elastography in patients with multiple sclerosis and healthy subjects. Med Ultrason. 2017;19:39–44.CrossRef Inal M, Tan S, Yumusak EM, MH S¸a, Alpua M, Ornek K. Evaluation of the optic nerve using strain and shear wave elastography in patients with multiple sclerosis and healthy subjects. Med Ultrason. 2017;19:39–44.CrossRef
9.
go back to reference Santos R, Armada P. Sciatic nerve hardness measurement by using ultrasound elastography. Ultrasound Med Biol. 2013;39(5):S57. Santos R, Armada P. Sciatic nerve hardness measurement by using ultrasound elastography. Ultrasound Med Biol. 2013;39(5):S57.
10.
go back to reference Andrade RJ, Nordez A, Hug F, et al. Non-invasive assessment of sciatic nerve stiffness during human ankle motion using ultrasound shear wave elastography. J Biomech. 2016;49(3):326–31.CrossRef Andrade RJ, Nordez A, Hug F, et al. Non-invasive assessment of sciatic nerve stiffness during human ankle motion using ultrasound shear wave elastography. J Biomech. 2016;49(3):326–31.CrossRef
11.
go back to reference Frymoyer JW, Pope MH, Clements JH, Wilder DG, MacPherson B, Ashikaga T. Risk factors in low-back pain. An epidemiological survey. J Bone Joint Surg. 1983;65:213–8.CrossRef Frymoyer JW, Pope MH, Clements JH, Wilder DG, MacPherson B, Ashikaga T. Risk factors in low-back pain. An epidemiological survey. J Bone Joint Surg. 1983;65:213–8.CrossRef
12.
go back to reference Chan WC, Sze KL, Samartzis D, Leung VY, Chan D. Structure and biology of the intervertebral disk in health and disease. Orthop Clin North Am. 2011;42:447–64.CrossRef Chan WC, Sze KL, Samartzis D, Leung VY, Chan D. Structure and biology of the intervertebral disk in health and disease. Orthop Clin North Am. 2011;42:447–64.CrossRef
15.
go back to reference Brayda-Bruno M, Tibiletti M, Ito K, et al. Advances in the diagnosis of degenerated lumbar discs and their possible clinical application. Eur Spine J 2014;23(SUPPL. 3):315–323. https://doi. org/10.1007/s00586-013-2960-9.CrossRef Brayda-Bruno M, Tibiletti M, Ito K, et al. Advances in the diagnosis of degenerated lumbar discs and their possible clinical application. Eur Spine J 2014;23(SUPPL. 3):315–323. https://​doi.​ org/10.1007/s00586-013-2960-9.CrossRef
20.
go back to reference Kantarci F, Ustabasioglu FE, Delil S, Olgun DC, Korkmazer B, Dikici AS, et al. Median nerve stiffness measurement by shear wave elastography: a potential sonographic method in the diagnosis of carpal tunnel syndrome. Eur Radiol. 2014;24(2):434–40.CrossRef Kantarci F, Ustabasioglu FE, Delil S, Olgun DC, Korkmazer B, Dikici AS, et al. Median nerve stiffness measurement by shear wave elastography: a potential sonographic method in the diagnosis of carpal tunnel syndrome. Eur Radiol. 2014;24(2):434–40.CrossRef
21.
go back to reference Dahlin LB, Lundborg G. The neurone and its response to peripheral nerve compression. J Hand Surg (Br). 1990;15:5–10.CrossRef Dahlin LB, Lundborg G. The neurone and its response to peripheral nerve compression. J Hand Surg (Br). 1990;15:5–10.CrossRef
Metadata
Title
The relationship of the shear wave elastography findings of patients with unilateral lumbar disc herniation and clinical characteristics
Authors
Qingyuan Wang
Hao Zhang
Jinxin Zhang
Hanqi Zhang
Hui Zheng
Publication date
01-12-2019
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2019
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-019-2814-7

Other articles of this Issue 1/2019

BMC Musculoskeletal Disorders 1/2019 Go to the issue