Abstract

Background

Iliosacral screw fixation is a popular method for the management of posterior pelvic ring fractures or dislocations, providing adequate biomechanical stability. Our aim in this study was to describe the use of a new patient-specific external template to guide the insertion of iliosacral screws and to evaluate the efficacy and safety of this technique compared with the conventional fluoroscopy-guided technique.

Methods

This was a retrospective study of patients with incomplete or complete posterior pelvic ring disruptions who required iliosacral screw fixation. For analysis, patients were divided into two groups: the external template group (37 screws in 22 patients) and the conventional group (28 screws in 18 patients). The operative time per screw, radiation exposure time and the rate of screw perforation (accuracy) were compared between groups. In the external template group, the difference between the actual and planned iliosacral screw position was also compared.

Results

In the conventional group, the average operative time per screw was 39.7 ± 10.6 min, with an average radiation exposure dose of 1904.0 ± 844.5 cGy/cm2, with 4 cases of screw perforation. In the external template group, the average operative time per screw was 17.9 ± 4.7 min, with an average radiation exposure dose of 742.8 ± 230.6 cGy/cm2 and 1 case of screw perforation. In the template group, the mean deviation distance between the actual and planned screw position was 2.75 ± 1.0 mm at the tip, 1.83 ± 0.67 mm in the nerve root tunnel zone and 1.52 ± 0.48 mm at the entry point, with a mean deviation angle of 1.73 ± 0.80°.

Conclusions

The external template provides an accurate and safe navigation tool for percutaneous iliosacral screw insertion that could decrease the operative time and radiation exposure.
Literature
1.
go back to reference Lee CH, Hsu CC, Huang PY. Biomechanical study of different fixation techniques for the treatment of sacroiliac joint injuries using finite element analyses and biomechanical tests. Comput Biol Med. 2017;87:250–7.CrossRef Lee CH, Hsu CC, Huang PY. Biomechanical study of different fixation techniques for the treatment of sacroiliac joint injuries using finite element analyses and biomechanical tests. Comput Biol Med. 2017;87:250–7.CrossRef
2.
go back to reference Matta JM, Saucedo T. Internal fixation of pelvic ring fractures. Clin Orthop Relat Res. 1989;242:83–97. Matta JM, Saucedo T. Internal fixation of pelvic ring fractures. Clin Orthop Relat Res. 1989;242:83–97.
3.
go back to reference Hinsche AF, Giannoudis PV, Smith RM. Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws. Clin Orthop Relat Res. 2002;395:135–44.CrossRef Hinsche AF, Giannoudis PV, Smith RM. Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws. Clin Orthop Relat Res. 2002;395:135–44.CrossRef
4.
go back to reference Templeman D, Schmidt A, Freese J, Weisman I. Proximity of iliosacral screws to neurovascular structures after internal fixation. Clin Orthop Relat Res. 1996;329:194–8.CrossRef Templeman D, Schmidt A, Freese J, Weisman I. Proximity of iliosacral screws to neurovascular structures after internal fixation. Clin Orthop Relat Res. 1996;329:194–8.CrossRef
5.
go back to reference Theologis AA, Burch S, Pekmezci M. Placement of iliosacral screws using 3D image-guided (O-arm) technology and stealth navigation: comparison with traditional fluoroscopy. Bone Joint J. 2016;98-B(5):696–702.CrossRef Theologis AA, Burch S, Pekmezci M. Placement of iliosacral screws using 3D image-guided (O-arm) technology and stealth navigation: comparison with traditional fluoroscopy. Bone Joint J. 2016;98-B(5):696–702.CrossRef
6.
go back to reference Pishnamaz M, Wilkmann C, Na HS, Pfeffer J, Hänisch C, Janssen M, et al. Electromagnetic real time navigation in the region of the posterior pelvic ring: an experimental in-vitro feasibility study and comparison of image guided techniques. PLoS One. 2016;11(2):e0148199.CrossRef Pishnamaz M, Wilkmann C, Na HS, Pfeffer J, Hänisch C, Janssen M, et al. Electromagnetic real time navigation in the region of the posterior pelvic ring: an experimental in-vitro feasibility study and comparison of image guided techniques. PLoS One. 2016;11(2):e0148199.CrossRef
7.
go back to reference Gras F, Marintschev I, Wilharm A, Klos K, Mückley T, Hofmann GO. 2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries--a case series. BMC Musculoskelet Disord. 2010;11:153.CrossRef Gras F, Marintschev I, Wilharm A, Klos K, Mückley T, Hofmann GO. 2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries--a case series. BMC Musculoskelet Disord. 2010;11:153.CrossRef
8.
go back to reference Zhang YZ, Lu S, Xu YQ, Shi JH, Li YB, Feng ZL. Application of navigation template to fixation of sacral fracture using three-dimensional reconstruction and reverse engineering technique. Chin J Traumatol. 2009;12(4):214–7.PubMed Zhang YZ, Lu S, Xu YQ, Shi JH, Li YB, Feng ZL. Application of navigation template to fixation of sacral fracture using three-dimensional reconstruction and reverse engineering technique. Chin J Traumatol. 2009;12(4):214–7.PubMed
9.
go back to reference Chen B, Zhang Y, Xiao S, Gu P, Lin X. Personalized image-based templates for iliosacral screw insertions: a pilot study. Int J Med Robot. 2012;8(4):476–82.CrossRef Chen B, Zhang Y, Xiao S, Gu P, Lin X. Personalized image-based templates for iliosacral screw insertions: a pilot study. Int J Med Robot. 2012;8(4):476–82.CrossRef
10.
go back to reference Kellam JF, Meinberg EG, Agel J, Karam MD, Roberts CS. Introduction: fracture and dislocation classification compendium-2018: international comprehensive classification of fractures and dislocations committee. J Orthop Trauma. 2018;32:S1–10.CrossRef Kellam JF, Meinberg EG, Agel J, Karam MD, Roberts CS. Introduction: fracture and dislocation classification compendium-2018: international comprehensive classification of fractures and dislocations committee. J Orthop Trauma. 2018;32:S1–10.CrossRef
11.
go back to reference Denis F, Davis S, Comfort T. Sacral fractures: an important problem. Retrospective analysis of 236 cases Clin Orthop Relat Res. 1988;227:67–81.PubMed Denis F, Davis S, Comfort T. Sacral fractures: an important problem. Retrospective analysis of 236 cases Clin Orthop Relat Res. 1988;227:67–81.PubMed
12.
go back to reference Lefaivre KA, Starr AJ, Reinert CM. Reduction of displaced pelvic ring disruptions using a pelvic reduction frame. J Orthop Trauma. 2009;23(4):299–308.CrossRef Lefaivre KA, Starr AJ, Reinert CM. Reduction of displaced pelvic ring disruptions using a pelvic reduction frame. J Orthop Trauma. 2009;23(4):299–308.CrossRef
13.
go back to reference Lefaivre KA, Starr AJ, Barker BP, Overturf S, Reinert CM. Early experience with reduction of displaced disruption of the pelvic ring using a pelvic reduction frame. J Bone Joint Surg Br. 2009;91(9):1201–7.CrossRef Lefaivre KA, Starr AJ, Barker BP, Overturf S, Reinert CM. Early experience with reduction of displaced disruption of the pelvic ring using a pelvic reduction frame. J Bone Joint Surg Br. 2009;91(9):1201–7.CrossRef
14.
go back to reference Takao M, Nishii T, Sakai T, Sugano N. CT-3D-fluoroscopy matching navigation can reduce the malposition rate of iliosacral screw insertion for less-experienced surgeons. J Orthop Trauma. 2013;27(12):716–21.CrossRef Takao M, Nishii T, Sakai T, Sugano N. CT-3D-fluoroscopy matching navigation can reduce the malposition rate of iliosacral screw insertion for less-experienced surgeons. J Orthop Trauma. 2013;27(12):716–21.CrossRef
15.
go back to reference Smith HE, Yuan PS, Sasso R, Papadopolous S, Vaccaro AR. An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws. Spine. 2006;31(2):234–8.CrossRef Smith HE, Yuan PS, Sasso R, Papadopolous S, Vaccaro AR. An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws. Spine. 2006;31(2):234–8.CrossRef
16.
go back to reference Tornetta P, Matta JM. Outcome of operatively treated unstable posterior pelvic ring disruptions. Clin Orthop Relat Res. 1996;329:186–93.CrossRef Tornetta P, Matta JM. Outcome of operatively treated unstable posterior pelvic ring disruptions. Clin Orthop Relat Res. 1996;329:186–93.CrossRef
17.
go back to reference Takao M, Nishii T, Sakai T, Yoshikawa H, Sugano N. Iliosacral screw insertion using CT-3D-fluoroscopy matching navigation. Injury. 2014;45(6):988–94.CrossRef Takao M, Nishii T, Sakai T, Yoshikawa H, Sugano N. Iliosacral screw insertion using CT-3D-fluoroscopy matching navigation. Injury. 2014;45(6):988–94.CrossRef
18.
go back to reference Kim JW, Quispe JC, Hao J, Herbert B, Hake M, Mauffrey C. Fluoroscopic views for a more accurate placement of iliosacral screws: an experimental study. J Orthop Trauma. 2016;30(1):34–40.CrossRef Kim JW, Quispe JC, Hao J, Herbert B, Hake M, Mauffrey C. Fluoroscopic views for a more accurate placement of iliosacral screws: an experimental study. J Orthop Trauma. 2016;30(1):34–40.CrossRef
19.
go back to reference Ozmeric A, Yucens M, Gultaç E, Açar HI, Aydogan NH, Gül D, et al. Are two different projections of the inlet view necessary for the percutaneous placement of iliosacral screws. Bone Joint J. 2015;97-B(5):705–710.CrossRef Ozmeric A, Yucens M, Gultaç E, Açar HI, Aydogan NH, Gül D, et al. Are two different projections of the inlet view necessary for the percutaneous placement of iliosacral screws. Bone Joint J. 2015;97-B(5):705–710.CrossRef
20.
go back to reference Shaw JC, MLC R, Gary JL. Intra-operative multi-dimensional fluoroscopy of guidepin placement prior to iliosacral screw fixation for posterior pelvic ring injuries and sacroiliac dislocation: an early case series. Int Orthop. 2017;41(10):2171–7.CrossRef Shaw JC, MLC R, Gary JL. Intra-operative multi-dimensional fluoroscopy of guidepin placement prior to iliosacral screw fixation for posterior pelvic ring injuries and sacroiliac dislocation: an early case series. Int Orthop. 2017;41(10):2171–7.CrossRef
21.
go back to reference Zheng Z, Zhang Y, Hou Z, Hao J, Zhai F, Su Y, et al. The application of a computer-assisted thermoplastic membrane navigation system in screw fixation of the sacroiliac joint--a clinical study. Injury. 2012;43(4):495–9.CrossRef Zheng Z, Zhang Y, Hou Z, Hao J, Zhai F, Su Y, et al. The application of a computer-assisted thermoplastic membrane navigation system in screw fixation of the sacroiliac joint--a clinical study. Injury. 2012;43(4):495–9.CrossRef
22.
go back to reference Takeba J, Umakoshi K, Kikuchi S, Matsumoto H, Annen S, Moriyama N, et al. Accuracy of screw fixation using the O-arm® and StealthStation® navigation system for unstable pelvic ring fractures. Eur J Orthop Surg Traumatol. 2018;28(3):431–8.CrossRef Takeba J, Umakoshi K, Kikuchi S, Matsumoto H, Annen S, Moriyama N, et al. Accuracy of screw fixation using the O-arm® and StealthStation® navigation system for unstable pelvic ring fractures. Eur J Orthop Surg Traumatol. 2018;28(3):431–8.CrossRef
23.
go back to reference Mastrangelo G, Fedeli U, Fadda E, Giovanazzi A, Scoizzato L, Saia B. Increased cancer risk among surgeons in an orthopaedic hospital. Occup Med. 2005;55(6):498–500.CrossRef Mastrangelo G, Fedeli U, Fadda E, Giovanazzi A, Scoizzato L, Saia B. Increased cancer risk among surgeons in an orthopaedic hospital. Occup Med. 2005;55(6):498–500.CrossRef
24.
go back to reference Jennison T, McNally M, Pandit H. Prevention of infection in external fixator pin sites. Acta Biomater. 2014;10(2):595–603.CrossRef Jennison T, McNally M, Pandit H. Prevention of infection in external fixator pin sites. Acta Biomater. 2014;10(2):595–603.CrossRef
25.
go back to reference Kazmers NH, Fragomen AT, Rozbruch SR. Prevention of pin site infection in external fixation: a review of the literature. Strategies Trauma Limb Reconstr. 2016;11(2):75–85.CrossRef Kazmers NH, Fragomen AT, Rozbruch SR. Prevention of pin site infection in external fixation: a review of the literature. Strategies Trauma Limb Reconstr. 2016;11(2):75–85.CrossRef
26.
go back to reference Cavusoglu AT, Er MS, Inal S, Ozsoy MH, Dincel VE, Sakaogullari A. Pin site care during circular external fixation using two different protocols. J Orthop Trauma. 2009;23(10):724–30.CrossRef Cavusoglu AT, Er MS, Inal S, Ozsoy MH, Dincel VE, Sakaogullari A. Pin site care during circular external fixation using two different protocols. J Orthop Trauma. 2009;23(10):724–30.CrossRef
27.
go back to reference Gordon JE, Kelly-Hahn J, Carpenter CJ, Schoenecker PL. Pin site care during external fixation in children: results of a nihilistic approach. J Pediatr Orthop. 2000;20(2):163–5.PubMed Gordon JE, Kelly-Hahn J, Carpenter CJ, Schoenecker PL. Pin site care during external fixation in children: results of a nihilistic approach. J Pediatr Orthop. 2000;20(2):163–5.PubMed
Metadata
Title
A novel patient-specific three-dimensional-printed external template to guide iliosacral screw insertion: a retrospective study
Authors
Fan Yang
Sheng Yao
Kai-fang Chen
Feng-zhao Zhu
Ze-kang Xiong
Yan-hui Ji
Ting-fang Sun
Xiao-dong Guo
Publication date
01-12-2018
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2018
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-018-2320-3

Other articles of this Issue 1/2018

BMC Musculoskeletal Disorders 1/2018 Go to the issue