Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2017

Open Access 01-12-2017 | Research article

Treatment of genu valgum in children by means of temporary hemiepiphysiodesis using eight-plates: short-term findings

Authors: Dirk Zajonz, Eckehard Schumann, Magdalena Wojan, Fabian B. Kübler, Christoph Josten, Ulf Bühligen, Christoph E. Heyde

Published in: BMC Musculoskeletal Disorders | Issue 1/2017

Login to get access

Abstract

Background

Idiopathic genu valgum is a frequently diagnosed growth disorder in adolescence. Whenever the possibilities of conservative therapy have been exhausted, leg straightening by means of hemiepiphysiodesis has become the standard form of treatment. Because of their flexible screw-plate connection, eight-Plates have been reported in the literature to lead to lower complications regarding implant loosening and fracture compared to other implants.
The aim of this retrospective survey was to analyse our own patient population who were treated for genu valgum by means of temporary hemiepiphysiodesis near the knee using eight-Plates to modulate growth.

Methods

Between July 2007 and July 2015, 198 eight-Plates were implanted near the knee in 132 children suffering from genu valgum to modulate growth. Depending on the deformity analysis, an eight-Plate was implanted on the distal medial femur and/or the proximal medial tibia. By December 2015, they had been removed from 105 patients. The etiology of genu valgum was mainly idiopathic or associated withobesity. Evaluation was carried out clinically and radiologically (whole-leg X-ray in standing) including determination of the joint angles.

Results

The median follow-up period was about 46 months (12–102 months). The median age at implantation was 12.7 +/−6.76 years. Of the 105 patients, 45.7% (n = 48) were girls. The eight-Plates remained in place for a median period of 13 +/−1.76 months. Irrespective of the location of hemiepiphysiodesis, the intermalleolar distance was corrected to a median of 0 +/−2.1 cm while the anatomical femorotibial angle was corrected by on average 9 +/−2.7 °Mechanical lateral distal femoral angle changed an average 7 +/− 7.72 degrees. Medial proximal tibial angle changed an average 4 +/− 6.02 degrees. Complications necessitating surgery occurred in 2.8% of cases (1 wound infection, 3 corrective osteotomies following overcorrection).

Conclusion

Temporary hemiepiphysiodesis using eight-Plates is a gentle, simple and effective procedure used to treat genu valgum by modulating growth. Slight overcorrection is desirable due to the rebound phenomenon, especially in young patients with high growth potential and risk groups such as obese children. In adolescents with only low growth potential (older than 14 years), owing to the low correction potential, the indication should be strictly reviewed and the possible failure of therapy should be discussed with the patient. No differences were observed regarding the location of the implanted eight-Plates (femoral or tibial).
Literature
5.
go back to reference Stevens PM, MacWilliams B, Mohr RA. Gait analysis of stapling for genu valgum. J Pediatr Orthop. 2004;24:70–4.CrossRefPubMed Stevens PM, MacWilliams B, Mohr RA. Gait analysis of stapling for genu valgum. J Pediatr Orthop. 2004;24:70–4.CrossRefPubMed
8.
go back to reference WP BLOUNT, Control CLARKEGR. Of bone growth by epiphyseal stapling; a preliminary report. J Bone Joint Surg Am. 1949;31A:464–78. WP BLOUNT, Control CLARKEGR. Of bone growth by epiphyseal stapling; a preliminary report. J Bone Joint Surg Am. 1949;31A:464–78.
9.
go back to reference Horton GA, Olney BW. Epiphysiodesis of the lower extremity: results of the percutaneous technique. J Pediatr Orthop. 1996;16:180–2.CrossRefPubMed Horton GA, Olney BW. Epiphysiodesis of the lower extremity: results of the percutaneous technique. J Pediatr Orthop. 1996;16:180–2.CrossRefPubMed
11.
go back to reference Eidelman M, D'Agostino P. Hemiepiphysiodesis around the knee by percutaneously guided and grooved staple. J Pediatr Orthop B. 2005;14:434–5.CrossRefPubMed Eidelman M, D'Agostino P. Hemiepiphysiodesis around the knee by percutaneously guided and grooved staple. J Pediatr Orthop B. 2005;14:434–5.CrossRefPubMed
12.
go back to reference Metaizeau JP, Wong-Chung J, Bertrand H, Pasquier P. Percutaneous epiphysiodesis using transphyseal screws (PETS). J Pediatr Orthop. 1998;18:363–9.PubMed Metaizeau JP, Wong-Chung J, Bertrand H, Pasquier P. Percutaneous epiphysiodesis using transphyseal screws (PETS). J Pediatr Orthop. 1998;18:363–9.PubMed
13.
go back to reference Nouth F, Kuo LA. Percutaneous epiphysiodesis using transphyseal screws (PETS): prospective case study and review. J Pediatr Orthop. 2004;24:721–5.CrossRefPubMed Nouth F, Kuo LA. Percutaneous epiphysiodesis using transphyseal screws (PETS): prospective case study and review. J Pediatr Orthop. 2004;24:721–5.CrossRefPubMed
14.
go back to reference BLOUNT WPA. Mature look at epiphyseal stapling. Clin Orthop Relat Res. 1971;77:158–63.PubMed BLOUNT WPA. Mature look at epiphyseal stapling. Clin Orthop Relat Res. 1971;77:158–63.PubMed
Metadata
Title
Treatment of genu valgum in children by means of temporary hemiepiphysiodesis using eight-plates: short-term findings
Authors
Dirk Zajonz
Eckehard Schumann
Magdalena Wojan
Fabian B. Kübler
Christoph Josten
Ulf Bühligen
Christoph E. Heyde
Publication date
01-12-2017
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2017
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-017-1823-7

Other articles of this Issue 1/2017

BMC Musculoskeletal Disorders 1/2017 Go to the issue