Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2016

Open Access 01-12-2016 | Research article

Using self-drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study

Authors: Alexaner Synek, Lars Borgmann, Hannes Traxler, Wolfgang Huf, Ekkehard Euler, Yan Chevalier, Sebastian F. Baumbach

Published in: BMC Musculoskeletal Disorders | Issue 1/2016

Login to get access

Abstract

Background

Symptomatic extensor tendon irritation is a frequent complication in volar plate osteosynthesis of distal radius fractures. It is typically caused by dorsal screw protrusion and overdrilling of the dorsal cortex. The use of self-drilling locking screws (SDLS) could overcome both causes. The practical applicability of SDLS depends on two prerequisites: (1) the feasibility of preoperative distal screw length determination, and (2) sufficient primary biomechanical stability of SDLS compared to standard locking screws (SLS).

Methods

We first assessed the feasibility of preoperative screw length determination (1): Distal radius width, depth and distal screw lengths were measured in 38 human radii. Correlations between distal radius width and depth were assessed, a cluster analysis (Ward’s method and squared Euclidean distance) for distal radius width conducted, and intra-cluster screw lengths analyzed (ANOVA). The biomechanical performance of SDLS (2) was assessed by comparison to SLS in a distal radius fracture model (AO-23 A3). 75 % distal screw length was chosen for both groups to simulate a worst-case scenario. Uniaxial compression tests were conducted to measure stiffness, elastic limit, maximum force and residual tilt. Statistics comprised of independent sample t-tests and a Bonferroni correction (p < 0.0125).

Results

(1) Distal radius width and depth showed a high correlation (R 2  = 0.79; p < 0.001). Three distal radius width clusters could be identified: small <34 mm; medium 34–36.9 mm; large >36.9 mm. ANOVA and Tukey post-hoc analysis revealed significantly different volar-dorsal depths (p < 0.05) for nearly all screws. (2) To assess biomechanical stability nine specimens were tested each; no significant differences were found between the SDLS and SLS groups.

Conclusions

This feasibility study demonstrates that (1) distal radius width can be used as a predictor for distal screw length and (2) that SDLS provides mechanical stability equivalent to SLS. These results highlight the feasibility of applying SDLS screws in volar plate osteosynthesis at least in extraarticular fractures.
Literature
2.
go back to reference Mattila VM, Huttunen TT, Sillanpää P, Niemi S, Pihlajamäki H, Kannus P. Significant change in the surgical treatment of distal radius fractures: a nationwide study between 1998 and 2008 in Finland. J Trauma. 2011;71(4):939–42. doi:10.1097/TA.0b013e3182231af9. discussion 42-3.CrossRefPubMed Mattila VM, Huttunen TT, Sillanpää P, Niemi S, Pihlajamäki H, Kannus P. Significant change in the surgical treatment of distal radius fractures: a nationwide study between 1998 and 2008 in Finland. J Trauma. 2011;71(4):939–42. doi:10.​1097/​TA.​0b013e3182231af9​. discussion 42-3.CrossRefPubMed
4.
go back to reference Knudsen R, Bahadirov Z, Damborg F. High rate of complications following volar plating of distal radius fractures. Dan Med J. 2014;61(10):A4906.PubMed Knudsen R, Bahadirov Z, Damborg F. High rate of complications following volar plating of distal radius fractures. Dan Med J. 2014;61(10):A4906.PubMed
5.
go back to reference Arora R, Lutz M, Deml C, Krappinger D, Haug L, Gabl M. A prospective randomized trial comparing nonoperative treatment with volar locking plate fixation for displaced and unstable distal radial fractures in patients sixty-five years of age and older. J Bone Joint Surg Am. 2011;93(23):2146–53. doi:10.2106/JBJS.J.01597.CrossRefPubMed Arora R, Lutz M, Deml C, Krappinger D, Haug L, Gabl M. A prospective randomized trial comparing nonoperative treatment with volar locking plate fixation for displaced and unstable distal radial fractures in patients sixty-five years of age and older. J Bone Joint Surg Am. 2011;93(23):2146–53. doi:10.​2106/​JBJS.​J.​01597.CrossRefPubMed
6.
go back to reference Al-Rashid M, Theivendran K, Craigen MAC. Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures. J Bone Joint Surg (Br). 2006;88(12):1610–2. doi:10.1302/0301-620X.88B12.17696.CrossRef Al-Rashid M, Theivendran K, Craigen MAC. Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures. J Bone Joint Surg (Br). 2006;88(12):1610–2. doi:10.​1302/​0301-620X.​88B12.​17696.CrossRef
9.
go back to reference Berglund LM, Messer TM. Complications of volar plate fixation for managing distal radius fractures. J Am Acad Orthop Surg. 2009;17(6):369–77.PubMed Berglund LM, Messer TM. Complications of volar plate fixation for managing distal radius fractures. J Am Acad Orthop Surg. 2009;17(6):369–77.PubMed
12.
go back to reference Perez EA. Fractures of the shoulder, arm, and forearm. 12th ed. Philadelphia: Campbell’s Operative Orthopaedics; 2012. p. 2819–916. Perez EA. Fractures of the shoulder, arm, and forearm. 12th ed. Philadelphia: Campbell’s Operative Orthopaedics; 2012. p. 2819–916.
14.
go back to reference Greenberg JA, Warden S, Izadi KD. The Effect Of Screw Length On Fracture Stability In Volar Locked Plating Of Distal Radius Fractures. New Orleans: Annual AAOS meeting; 2010. Greenberg JA, Warden S, Izadi KD. The Effect Of Screw Length On Fracture Stability In Volar Locked Plating Of Distal Radius Fractures. New Orleans: Annual AAOS meeting; 2010.
15.
go back to reference Wall LB, Brodt MD, Silva MJ, Boyer MI, Calfee RP. The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates. J Hand Surg [Am]. 2012;37(3):446–53. doi:10.1016/j.jhsa.2011.12.013.CrossRef Wall LB, Brodt MD, Silva MJ, Boyer MI, Calfee RP. The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates. J Hand Surg [Am]. 2012;37(3):446–53. doi:10.​1016/​j.​jhsa.​2011.​12.​013.CrossRef
16.
18.
19.
go back to reference Mischkowski RA, Kneuertz P, Florvaag B, Lazar F, Koebke J, Zöller JE. Biomechanical comparison of four different miniscrew types for skeletal anchorage in the mandibulo-maxillary area. Int J Oral Maxillofac Surg. 2008;37(10):948–54. doi:10.1016/j.ijom.2008.07.017.CrossRefPubMed Mischkowski RA, Kneuertz P, Florvaag B, Lazar F, Koebke J, Zöller JE. Biomechanical comparison of four different miniscrew types for skeletal anchorage in the mandibulo-maxillary area. Int J Oral Maxillofac Surg. 2008;37(10):948–54. doi:10.​1016/​j.​ijom.​2008.​07.​017.CrossRefPubMed
22.
go back to reference Baumbach SF, Schmidt R, Varga P, Heinz T, Vécsei V, Zysset PK. Where is the distal fracture line location of dorsally displaced distal radius fractures? J Orthop Res. 2011;29(4):489–94. doi:10.1002/jor.21268.CrossRefPubMed Baumbach SF, Schmidt R, Varga P, Heinz T, Vécsei V, Zysset PK. Where is the distal fracture line location of dorsally displaced distal radius fractures? J Orthop Res. 2011;29(4):489–94. doi:10.​1002/​jor.​21268.CrossRefPubMed
23.
go back to reference Synek A, Chevalier Y, Schroder C, Pahr DH, Baumbach SF. Biomechanical testing of distal radius fracture treatments: boundary conditions significantly affect the outcome of in vitro experiments. J Appl Biomech. 2015. doi:10.1123/jab.2015-0117.PubMed Synek A, Chevalier Y, Schroder C, Pahr DH, Baumbach SF. Biomechanical testing of distal radius fracture treatments: boundary conditions significantly affect the outcome of in vitro experiments. J Appl Biomech. 2015. doi:10.​1123/​jab.​2015-0117.PubMed
24.
go back to reference Veldpaus FE, Woltring HJ, Dortmans LJ. A least-squares algorithm for the equiform transformation from spatial marker co-ordinates. J Biomech. 1988;21(1):45–54.CrossRefPubMed Veldpaus FE, Woltring HJ, Dortmans LJ. A least-squares algorithm for the equiform transformation from spatial marker co-ordinates. J Biomech. 1988;21(1):45–54.CrossRefPubMed
25.
go back to reference Cohen J. Statistical Power Analysis for Behavioral Sciences. 2nd ed. Hillsdale: Larence Erlbaum Associates; 1988. Cohen J. Statistical Power Analysis for Behavioral Sciences. 2nd ed. Hillsdale: Larence Erlbaum Associates; 1988.
26.
go back to reference Cohen J, Cohen P, West S, Aiken L. Applied multiple regression/correlation analysis for the behavioral sciences. Lawrence Erlbaum Assoc Inc; Third Edition. Mahwah, New Jersey, USA: Book; 2013. Cohen J, Cohen P, West S, Aiken L. Applied multiple regression/correlation analysis for the behavioral sciences. Lawrence Erlbaum Assoc Inc; Third Edition. Mahwah, New Jersey, USA: Book; 2013.
27.
go back to reference Sakaue K. Sexual determination of long bones in recent Japanese. Anthropol Sci. 2004;112:75–81.CrossRef Sakaue K. Sexual determination of long bones in recent Japanese. Anthropol Sci. 2004;112:75–81.CrossRef
29.
go back to reference Jantz RL, Moore-Jansen PH. A Data Base for Forensic Anthropology. Washington, D.C. USA: Final Report to the National Institute of Justice; 1988. Jantz RL, Moore-Jansen PH. A Data Base for Forensic Anthropology. Washington, D.C. USA: Final Report to the National Institute of Justice; 1988.
31.
go back to reference Haug LC, Glodny B, Deml C, Lutz M, Attal R. A new radiological method to detect dorsally penetrating screws when using volar locking plates in distal radial fractures. The dorsal horizon view. Bone Joint J. 2013;95-B(8):1101–5. doi:10.1302/0301-620X.95B8.31301.CrossRefPubMed Haug LC, Glodny B, Deml C, Lutz M, Attal R. A new radiological method to detect dorsally penetrating screws when using volar locking plates in distal radial fractures. The dorsal horizon view. Bone Joint J. 2013;95-B(8):1101–5. doi:10.​1302/​0301-620X.​95B8.​31301.CrossRefPubMed
32.
go back to reference Mehling I, Müller LP, Delinsky K, Mehler D, Burkhart KJ, Rommens PM. Number and locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study. J Hand Surg [Am]. 2010;35(6):885–91. doi:10.1016/j.jhsa.2010.03.027.CrossRef Mehling I, Müller LP, Delinsky K, Mehler D, Burkhart KJ, Rommens PM. Number and locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study. J Hand Surg [Am]. 2010;35(6):885–91. doi:10.​1016/​j.​jhsa.​2010.​03.​027.CrossRef
33.
go back to reference Blythe M, Stoffel K, Jarrett P, Kuster M. Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers. J Hand Surg [Am]. 2006;31(10):1587–93. doi:10.1016/j.jhsa.2006.09.011.CrossRef Blythe M, Stoffel K, Jarrett P, Kuster M. Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers. J Hand Surg [Am]. 2006;31(10):1587–93. doi:10.​1016/​j.​jhsa.​2006.​09.​011.CrossRef
34.
go back to reference Putnam MD, Meyer NJ, Nelson EW, Gesensway D, Lewis JL. Distal radial metaphyseal forces in an extrinsic grip model: implications for postfracture rehabilitation. J Hand Surg [Am]. 2000;25(3):469–75. doi:10.1053/jhsu.2000.6915.CrossRef Putnam MD, Meyer NJ, Nelson EW, Gesensway D, Lewis JL. Distal radial metaphyseal forces in an extrinsic grip model: implications for postfracture rehabilitation. J Hand Surg [Am]. 2000;25(3):469–75. doi:10.​1053/​jhsu.​2000.​6915.CrossRef
35.
go back to reference Chao EY, Opgrande JD, Axmear FE. Three-dimensional force analysis of finger joints in selected isometric hand functions. J Biomech. 1976;9(6):387–96.CrossRefPubMed Chao EY, Opgrande JD, Axmear FE. Three-dimensional force analysis of finger joints in selected isometric hand functions. J Biomech. 1976;9(6):387–96.CrossRefPubMed
36.
go back to reference Heidemann W, Terheyden H, Gerlach KL. Analysis of the osseous/metal interface of drill free screws and self-tapping screws. J Craniomaxillofac Surg. 2001;29(2):69–74.CrossRefPubMed Heidemann W, Terheyden H, Gerlach KL. Analysis of the osseous/metal interface of drill free screws and self-tapping screws. J Craniomaxillofac Surg. 2001;29(2):69–74.CrossRefPubMed
37.
go back to reference Rikli DA, Honigmann P, Babst R, Cristalli A, Morlock MM, Mittlmeier T. Intra-articular pressure measurement in the radioulnocarpal joint using a novel sensor: in vitro and in vivo results. J Hand Surg [Am]. 2007;32(1):67–75. doi:10.1016/j.jhsa.2006.10.007.CrossRef Rikli DA, Honigmann P, Babst R, Cristalli A, Morlock MM, Mittlmeier T. Intra-articular pressure measurement in the radioulnocarpal joint using a novel sensor: in vitro and in vivo results. J Hand Surg [Am]. 2007;32(1):67–75. doi:10.​1016/​j.​jhsa.​2006.​10.​007.CrossRef
Metadata
Title
Using self-drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study
Authors
Alexaner Synek
Lars Borgmann
Hannes Traxler
Wolfgang Huf
Ekkehard Euler
Yan Chevalier
Sebastian F. Baumbach
Publication date
01-12-2016
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2016
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-016-0972-4

Other articles of this Issue 1/2016

BMC Musculoskeletal Disorders 1/2016 Go to the issue