The value of repeat radial-probe endobronchial ultrasound-guided transbronchial biopsy after initial non-diagnostic results in patients with peripheral pulmonary lesions

Authors: Chun-Ta Huang, Yi-Ju Tsai, Chao-Chi Ho, Chong-Jen Yu

Published in: BMC Pulmonary Medicine | Issue 1/2017

Login to get access

Abstract

Background

Radial-probe endobronchial ultrasound (rEBUS)-guided transbronchial biopsy (TBB) is invaluable in the diagnosis of peripheral pulmonary lesions (PPLs); however, in certain instances, the procedure has to be repeated because of initial non-diagnostic procedure(s). Little if any literature has been published on this issue. Therefore, the aim of this study was to investigate the utility of repeat rEBUS-guided TBB in achieving a definitive diagnosis of PPLs.

Methods

All patients who underwent rEBUS-guided TBB of PPLs at National Taiwan University Hospital between 2011 and 2015 and had a repeat procedure after non-diagnostic initial procedures were identified as the study subjects. The primary outcome of interest was the diagnostic yield of repeat rEBUS-guided TBB for PPLs. Also, we sought to discover features associated with the yield of repeat procedures.

Results

Forty-three (11%) out of 384 patients with initial non-diagnostic TBB were included for analysis. A diagnosis of PPLs was able to be confirmed with repeat TBB in 23(53%) patients. The pathology of the first TBB was significantly associated with the yield of repeat procedures (P = 0.011). Further, patients with normal lung tissue in initial pathology rarely (2/12, 17%) had a definite diagnosis on repeat TBB. Yet, patients with pathology showing atypical cells and other non-specific findings were more likely (21/31, 68%) to obtain a confirmed diagnosis. The diagnostic yield of repeat procedures was not affected by the size, location or CT appearance of the lesions, or position of the rEBUS probe. No death or other serious adverse events occurred with the repeat rEBUS-guided procedures.

Conclusions

If clinically indicated, it is reasonable to repeat rEBUS-guided TBB after an initial non-diagnostic procedure as the diagnostic yield will be at least 50% and the side effect profile is favorable.
Literature
1.
go back to reference Herth FJ, Ernst A, Becker HD. Endobronchial ultrasound-guided transbronchial lung biopsy in solitary pulmonary nodules and peripheral lesions. Eur Respir J. 2002;20(4):972–4.CrossRefPubMed Herth FJ, Ernst A, Becker HD. Endobronchial ultrasound-guided transbronchial lung biopsy in solitary pulmonary nodules and peripheral lesions. Eur Respir J. 2002;20(4):972–4.CrossRefPubMed
3.
go back to reference Steinfort DP, Khor YH, Manser RL, Irving LB. Radial probe endobronchial ultrasound for the diagnosis of peripheral lung cancer: systematic review and meta-analysis. Eur Respir J. 2011;37(4):902–10.CrossRefPubMed Steinfort DP, Khor YH, Manser RL, Irving LB. Radial probe endobronchial ultrasound for the diagnosis of peripheral lung cancer: systematic review and meta-analysis. Eur Respir J. 2011;37(4):902–10.CrossRefPubMed
4.
go back to reference Wang Memoli JS, Nietert PJ, Silvestri GA. Meta-analysis of guided bronchoscopy for the evaluation of the pulmonary nodule. Chest. 2012;142(2):385–93.CrossRefPubMed Wang Memoli JS, Nietert PJ, Silvestri GA. Meta-analysis of guided bronchoscopy for the evaluation of the pulmonary nodule. Chest. 2012;142(2):385–93.CrossRefPubMed
5.
go back to reference Rivera MP, Mehta AC, Wahidi MM. Establishing the diagnosis of lung cancer: diagnosis and management of lung cancer, 3rd ed: American College of Chest Physicians evidence-based clinical practice guidelines. Chest. 2013;143(5 Suppl):e142S–65S.CrossRefPubMed Rivera MP, Mehta AC, Wahidi MM. Establishing the diagnosis of lung cancer: diagnosis and management of lung cancer, 3rd ed: American College of Chest Physicians evidence-based clinical practice guidelines. Chest. 2013;143(5 Suppl):e142S–65S.CrossRefPubMed
6.
go back to reference Eberhardt R, Ernst A, Herth FJ. Ultrasound-guided transbronchial biopsy of solitary pulmonary nodules less than 20 mm. Eur Respir J. 2009;34(6):1284–7.CrossRefPubMed Eberhardt R, Ernst A, Herth FJ. Ultrasound-guided transbronchial biopsy of solitary pulmonary nodules less than 20 mm. Eur Respir J. 2009;34(6):1284–7.CrossRefPubMed
7.
go back to reference Huang CT, Ho CC, Tsai YJ, Yu CJ, Yang PC. Factors influencing visibility and diagnostic yield of transbronchial biopsy using endobronchial ultrasound in peripheral pulmonary lesions. Respirology. 2009;14(6):859–64.CrossRefPubMed Huang CT, Ho CC, Tsai YJ, Yu CJ, Yang PC. Factors influencing visibility and diagnostic yield of transbronchial biopsy using endobronchial ultrasound in peripheral pulmonary lesions. Respirology. 2009;14(6):859–64.CrossRefPubMed
8.
go back to reference Kurimoto N, Miyazawa T, Okimasa S, Maeda A, Oiwa H, Miyazu Y, Murayama M. Endobronchial ultrasonography using a guide sheath increases the ability to diagnose peripheral pulmonary lesions endoscopically. Chest. 2004;126(3):959–65.CrossRefPubMed Kurimoto N, Miyazawa T, Okimasa S, Maeda A, Oiwa H, Miyazu Y, Murayama M. Endobronchial ultrasonography using a guide sheath increases the ability to diagnose peripheral pulmonary lesions endoscopically. Chest. 2004;126(3):959–65.CrossRefPubMed
9.
go back to reference Yoshikawa M, Sukoh N, Yamazaki K, Kanazawa K, Fukumoto S, Harada M, Kikuchi E, Munakata M, Nishimura M, Isobe H. Diagnostic value of endobronchial ultrasonography with a guide sheath for peripheral pulmonary lesions without X-ray fluoroscopy. Chest. 2007;131(6):1788–93.CrossRefPubMed Yoshikawa M, Sukoh N, Yamazaki K, Kanazawa K, Fukumoto S, Harada M, Kikuchi E, Munakata M, Nishimura M, Isobe H. Diagnostic value of endobronchial ultrasonography with a guide sheath for peripheral pulmonary lesions without X-ray fluoroscopy. Chest. 2007;131(6):1788–93.CrossRefPubMed
10.
go back to reference Ost DE, Ernst A, Lei X, Kovitz KL, Benzaquen S, Diaz-Mendoza J, Greenhill S, Toth J, Feller-Kopman D, Puchalski J, et al. Diagnostic yield and complications of Bronchoscopy for peripheral lung lesions. Results of the AQuIRE registry. Am J Respir Crit Care Med. 2016;193(1):68–77.CrossRefPubMedPubMedCentral Ost DE, Ernst A, Lei X, Kovitz KL, Benzaquen S, Diaz-Mendoza J, Greenhill S, Toth J, Feller-Kopman D, Puchalski J, et al. Diagnostic yield and complications of Bronchoscopy for peripheral lung lesions. Results of the AQuIRE registry. Am J Respir Crit Care Med. 2016;193(1):68–77.CrossRefPubMedPubMedCentral
11.
go back to reference Oki M, Saka H, Ando M, Asano F, Kurimoto N, Morita K, Kitagawa C, Kogure Y, Miyazawa T. Ultrathin Bronchoscopy with multimodal devices for peripheral pulmonary lesions. A randomized trial. Am J Respir Crit Care Med. 2015;192(4):468–76.CrossRefPubMed Oki M, Saka H, Ando M, Asano F, Kurimoto N, Morita K, Kitagawa C, Kogure Y, Miyazawa T. Ultrathin Bronchoscopy with multimodal devices for peripheral pulmonary lesions. A randomized trial. Am J Respir Crit Care Med. 2015;192(4):468–76.CrossRefPubMed
12.
go back to reference Huang CT, Tsai YJ, Liao WY, Wu PC, Ho CC, Yu CJ, Yang PC. Endobronchial ultrasound-guided transbronchial biopsy of peripheral pulmonary lesions: how many specimens are necessary? Respiration. 2012;84(2):128–34.CrossRefPubMed Huang CT, Tsai YJ, Liao WY, Wu PC, Ho CC, Yu CJ, Yang PC. Endobronchial ultrasound-guided transbronchial biopsy of peripheral pulmonary lesions: how many specimens are necessary? Respiration. 2012;84(2):128–34.CrossRefPubMed
13.
go back to reference Chung YH, Lie CH, Chao TY, Wang YH, Lin AS, Wang JL, Lin MC. Endobronchial ultrasonography with distance for peripheral pulmonary lesions. Respir Med. 2007;101(4):738–45.CrossRefPubMed Chung YH, Lie CH, Chao TY, Wang YH, Lin AS, Wang JL, Lin MC. Endobronchial ultrasonography with distance for peripheral pulmonary lesions. Respir Med. 2007;101(4):738–45.CrossRefPubMed
14.
go back to reference Gupta S, Krishnamurthy S, Broemeling LD, Morello FA Jr, Wallace MJ, Ahrar K, Madoff DC, Murthy R, Hicks ME. Small (</=2-cm) subpleural pulmonary lesions: short- versus long-needle-path CT-guided biopsy--comparison of diagnostic yields and complications. Radiology. 2005;234(2):631–7.CrossRefPubMed Gupta S, Krishnamurthy S, Broemeling LD, Morello FA Jr, Wallace MJ, Ahrar K, Madoff DC, Murthy R, Hicks ME. Small (</=2-cm) subpleural pulmonary lesions: short- versus long-needle-path CT-guided biopsy--comparison of diagnostic yields and complications. Radiology. 2005;234(2):631–7.CrossRefPubMed
15.
go back to reference Heyer CM, Reichelt S, Peters SA, Walther JW, Muller KM, Nicolas V. Computed tomography-navigated transthoracic core biopsy of pulmonary lesions: which factors affect diagnostic yield and complication rates? Acad Radiol. 2008;15(8):1017–26.CrossRefPubMed Heyer CM, Reichelt S, Peters SA, Walther JW, Muller KM, Nicolas V. Computed tomography-navigated transthoracic core biopsy of pulmonary lesions: which factors affect diagnostic yield and complication rates? Acad Radiol. 2008;15(8):1017–26.CrossRefPubMed
16.
go back to reference Wahidi MM, Govert JA, Goudar RK, Gould MK, McCrory DC, American College of Chest P. Evidence for the treatment of patients with pulmonary nodules: when is it lung cancer?: ACCP evidence-based clinical practice guidelines (2nd edition). Chest. 2007;132(3 Suppl):94S–107S.CrossRefPubMed Wahidi MM, Govert JA, Goudar RK, Gould MK, McCrory DC, American College of Chest P. Evidence for the treatment of patients with pulmonary nodules: when is it lung cancer?: ACCP evidence-based clinical practice guidelines (2nd edition). Chest. 2007;132(3 Suppl):94S–107S.CrossRefPubMed
17.
go back to reference Jacomelli M, Demarzo SE, Cardoso PF, Palomino AL, Figueiredo VR. Radial-probe EBUS for the diagnosis of peripheral pulmonary lesions. J Bras Pneumol. 2016;42(4):248–53.CrossRefPubMedPubMedCentral Jacomelli M, Demarzo SE, Cardoso PF, Palomino AL, Figueiredo VR. Radial-probe EBUS for the diagnosis of peripheral pulmonary lesions. J Bras Pneumol. 2016;42(4):248–53.CrossRefPubMedPubMedCentral
18.
go back to reference Ye J, Zhang R, Ma S, Wang L, Jin W. Endobronchial ultrasound plus fluoroscopy-guided biopsy compared to fluoroscopy-guided transbronchial biopsy for obtaining samples of peripheral pulmonary lesions: a systematic review and meta-analysis. Ann Thorac Med. 2017;12(2):114–20.CrossRefPubMedPubMedCentral Ye J, Zhang R, Ma S, Wang L, Jin W. Endobronchial ultrasound plus fluoroscopy-guided biopsy compared to fluoroscopy-guided transbronchial biopsy for obtaining samples of peripheral pulmonary lesions: a systematic review and meta-analysis. Ann Thorac Med. 2017;12(2):114–20.CrossRefPubMedPubMedCentral
Metadata
Title
The value of repeat radial-probe endobronchial ultrasound-guided transbronchial biopsy after initial non-diagnostic results in patients with peripheral pulmonary lesions
Authors
Chun-Ta Huang
Yi-Ju Tsai
Chao-Chi Ho
Chong-Jen Yu
Publication date
01-12-2017
Publisher
BioMed Central
Published in
BMC Pulmonary Medicine / Issue 1/2017
Electronic ISSN: 1471-2466
DOI
https://doi.org/10.1186/s12890-017-0478-3

Other articles of this Issue 1/2017

BMC Pulmonary Medicine 1/2017 Go to the issue