Skip to main content
Top
Published in: BMC Pulmonary Medicine 1/2016

Open Access 01-12-2016 | Technical advance

Small lung lesions invisible under fluoroscopy are located accurately by three-dimensional localization technique on chest wall surface and performed bronchoscopy procedures to increase diagnostic yields

Authors: Chaosheng Deng, Xiaoming Cao, Dawen Wu, Haibo Ding, Ruixiong You, Qunlin Chen, Linying Chen, Xin Zhang, Qiaoxian Zhang, Yongquan Wu

Published in: BMC Pulmonary Medicine | Issue 1/2016

Login to get access

Abstract

Background

Nowadays, small peripheral pulmonary lesions (PPLs) are frequently detected and the prognosis of lung cancer depends on the early diagnosis. Because of the high fee and requiring specialized training, many advanced techniques are not available in many developing countries and rural districts.

Methods

Three sets of opaque soft copper wires visible under the fluoroscopy (Flu) in the Flu-flexible bronchoscopy (FB) group (n = 24), which determined the three planes of the lesion, were respectively placed firmly on the surface of the chest wall with adhesive tape on the chest wall. The FB tip was advanced into the bronchus toward the crosspoint of the three perpendicular planes under Flu with careful rotation of a C-arm unit. Then the specimen were harvested focusing around the crosspoint for pathologic diagnosis. The rapid on-site evaluation (ROSE) procedure was also performed. The average Flu time during FB procedures were recorded and diagnostic accuracy rates in the Flu-FB group were compared with the other group guided by radial endobronchial ultrasound (R-EBUS) (n = 23).

Results

The location of the core point of the lesion, whether it was visible or not under the fluoroscopy could be recognized by three-dimensional localization technique. The accuracy rates of diagnostic yields were 62.5% in the Flu-FB group, and was similar as 65.2% in the R-EBUS group (P > 0.05). However, in the Flu-FB group, there was a decreasing tendency on accurate diagnosis rates of lower lobe (LL) lesions when comparing with non-LL lesions (3/8 = 37.5% vs 12/16 = 75%, P = 0.091) while in the R-EBUS group it was similar (9/12 = 75% vs 6/11 = 54.6%, P = 0.278). In the Flu-FB group, fluoroscopy time was negatively correlated with the lesion length (r = −0.613, P = 0.001), however, there was no significant difference between the lesions invisible or not (5.83 ± 1.45 min vs 7.67 ± 2.02 min, P = 0.116) under the fluoroscopy, as well as no significant difference among SPN, mGGO and GGO (6.12 ± 2.05 min, 7.25 ± 1.33 min and 7.80 ± 2.02 min, P > 0.05).

Conclusions

Small PPL whether it is visible or not under fluoroscopy can be located accurately by our three-dimensional localization technique on chest wall surface and performed bronchoscopy procedures to increase diagnostic yields. It is more convenient, economical and reliable with the similar diagnostic yields than R-EBUS guided method.

Trial registration

Current Controlled Trials ChiCTR-DDD-16009715. The date of registration: 3rd Nov, 2016. Retrospectively registered.
Literature
1.
go back to reference Seo JM, Lee HY, Kim HK, Choi YS, Kim J, Shim YM, et al. Factors determining successful computed tomography-guided localization of lung nodules. J Thorac Cardiovasc Surg. 2012;143(4):809–14.CrossRefPubMed Seo JM, Lee HY, Kim HK, Choi YS, Kim J, Shim YM, et al. Factors determining successful computed tomography-guided localization of lung nodules. J Thorac Cardiovasc Surg. 2012;143(4):809–14.CrossRefPubMed
2.
go back to reference Swensen SJ, Jett JR, Hartman TE, Midthun DE, Mandrekar SJ, Hillman SL, et al. CT screening for lung cancer: five-year prospective experience. Radiology. 2005;235(1):259–65.CrossRefPubMed Swensen SJ, Jett JR, Hartman TE, Midthun DE, Mandrekar SJ, Hillman SL, et al. CT screening for lung cancer: five-year prospective experience. Radiology. 2005;235(1):259–65.CrossRefPubMed
3.
go back to reference Murrmann GB, van Vollenhoven FH, Moodley L. Approach to a solid solitary pulmonary nodule in two different settings—common is common, rare is rare. J Thorac Dis. 2014;6(3):237–48.PubMedPubMedCentral Murrmann GB, van Vollenhoven FH, Moodley L. Approach to a solid solitary pulmonary nodule in two different settings—common is common, rare is rare. J Thorac Dis. 2014;6(3):237–48.PubMedPubMedCentral
4.
go back to reference Fujita Y, Seki N, Kurimoto N, Inoue K, Miyazawa T, Abe T, et al. Introduction of Endobronchial Ultrasonography (EBUS) in bronchoscopy clearly reduces fluoroscopy time: comparison of 147 cases in groups before and after EBUS introduction. Jpn J Clin Oncol. 2011;41(10):1177–81.CrossRefPubMed Fujita Y, Seki N, Kurimoto N, Inoue K, Miyazawa T, Abe T, et al. Introduction of Endobronchial Ultrasonography (EBUS) in bronchoscopy clearly reduces fluoroscopy time: comparison of 147 cases in groups before and after EBUS introduction. Jpn J Clin Oncol. 2011;41(10):1177–81.CrossRefPubMed
5.
go back to reference Wang Memoli JS, Nietert PJ, Silvestri GA. Meta-analysis of guided bronchoscopy for the evaluation of the pulmonary nodule. Chest. 2012;142(2):385–93.CrossRefPubMed Wang Memoli JS, Nietert PJ, Silvestri GA. Meta-analysis of guided bronchoscopy for the evaluation of the pulmonary nodule. Chest. 2012;142(2):385–93.CrossRefPubMed
7.
go back to reference Watanabe K, Nomori H, Ohtsuka T, Kaji M, Naruke T, Suemasu K. Usefulness and complications of computed tomography-guided lipiodol marking for fluoroscopy -assisted thoracoscopic resection of small pulmonary nodules: experience with 174 nodules. J Thorac Cardiovasc Surg. 2006;132(2):320–4.CrossRefPubMed Watanabe K, Nomori H, Ohtsuka T, Kaji M, Naruke T, Suemasu K. Usefulness and complications of computed tomography-guided lipiodol marking for fluoroscopy -assisted thoracoscopic resection of small pulmonary nodules: experience with 174 nodules. J Thorac Cardiovasc Surg. 2006;132(2):320–4.CrossRefPubMed
8.
go back to reference Chang SS, Nakano T, Okamoto T. Usefulness of intraoperative computer tomography-assisted thoracoscopic segmentectomy for small-sized lung cancer. Ann Thorac Cardiovasc Surg. 2015;23. [Epub ahead of print] (Article ID: cr. 15–00212) Chang SS, Nakano T, Okamoto T. Usefulness of intraoperative computer tomography-assisted thoracoscopic segmentectomy for small-sized lung cancer. Ann Thorac Cardiovasc Surg. 2015;23. [Epub ahead of print] (Article ID: cr. 15–00212)
9.
go back to reference Izumo T, Sasada S, Chavez C, Tsuchida T. The diagnostic utility of endobronchial ultrasonography with a guide sheath and tomosynthesis images for ground glass opacity pulmonary lesions. J Thorac Dis. 2013;5(6):745–50.PubMedPubMedCentral Izumo T, Sasada S, Chavez C, Tsuchida T. The diagnostic utility of endobronchial ultrasonography with a guide sheath and tomosynthesis images for ground glass opacity pulmonary lesions. J Thorac Dis. 2013;5(6):745–50.PubMedPubMedCentral
10.
go back to reference Ohtaka K, Takahashi Y, Kaga K, Senmaru N, Kotani Y, Matsui Y. Video-assisted thoracoscopic surgery using mobile computed tomography: new method for locating of small lung nodules. J Cardiothorac Surg. 2014;9:110.CrossRefPubMedPubMedCentral Ohtaka K, Takahashi Y, Kaga K, Senmaru N, Kotani Y, Matsui Y. Video-assisted thoracoscopic surgery using mobile computed tomography: new method for locating of small lung nodules. J Cardiothorac Surg. 2014;9:110.CrossRefPubMedPubMedCentral
11.
go back to reference Sakiyama S, Kondo K, Matsuoka H, Yoshida M, Miyoshi T, Yoshida S, et al. Fatal air embolism during computed tomography-guided pulmonary marking with a hook-type marker. J Thorac Cardiovasc Surg. 2003;126(4):1207–9.CrossRefPubMed Sakiyama S, Kondo K, Matsuoka H, Yoshida M, Miyoshi T, Yoshida S, et al. Fatal air embolism during computed tomography-guided pulmonary marking with a hook-type marker. J Thorac Cardiovasc Surg. 2003;126(4):1207–9.CrossRefPubMed
12.
go back to reference Torrington KG, Kern JD. The utility of fiberoptic bronchoscopy in the evaluation of the solitary pulmonary nodule. Chest. 1993;104:1021–4.CrossRefPubMed Torrington KG, Kern JD. The utility of fiberoptic bronchoscopy in the evaluation of the solitary pulmonary nodule. Chest. 1993;104:1021–4.CrossRefPubMed
13.
go back to reference Mammarappallil JG, Hiatt KD, Ge Q, Clark HP. Computed tomography Fluoroscopy versus conventional computed tomography guidance for biopsy of intrathoracic lesions: a retrospective review of 1143 consecutive procedures. J Thorac Imaging. 2014;29(6):340–3.CrossRefPubMed Mammarappallil JG, Hiatt KD, Ge Q, Clark HP. Computed tomography Fluoroscopy versus conventional computed tomography guidance for biopsy of intrathoracic lesions: a retrospective review of 1143 consecutive procedures. J Thorac Imaging. 2014;29(6):340–3.CrossRefPubMed
14.
go back to reference Tsushima K, Sone S, Hanaoka T, Takayama F, Honda T, Kubo K. Comparison of bronchoscopic diagnosis for peripheral pulmonary nodule under fluoroscopic guidance with CT guidance. Respir Med. 2006;100(4):737–45.CrossRefPubMed Tsushima K, Sone S, Hanaoka T, Takayama F, Honda T, Kubo K. Comparison of bronchoscopic diagnosis for peripheral pulmonary nodule under fluoroscopic guidance with CT guidance. Respir Med. 2006;100(4):737–45.CrossRefPubMed
15.
go back to reference Whitson BA, Groth SS, Odell DD, Briones EP, Maddaus MA, D’Cunha J, et al. True negative predictive value of endobronchial ultrasound in lung cancer: are we being conservative enough? Ann Thorac Surg. 2013;95(5):1689–94.CrossRefPubMed Whitson BA, Groth SS, Odell DD, Briones EP, Maddaus MA, D’Cunha J, et al. True negative predictive value of endobronchial ultrasound in lung cancer: are we being conservative enough? Ann Thorac Surg. 2013;95(5):1689–94.CrossRefPubMed
16.
go back to reference Yarmus L, Van der Kloot T, Lechtzin N, Napier M, Dressel D, Feller-Kopman D. A randomized prospective trial of the utility of rapid on-site evaluation of transbronchial needle aspirate specimens. J Bronchology Interv Pulmonol. 2011;18(2):121–7.CrossRefPubMed Yarmus L, Van der Kloot T, Lechtzin N, Napier M, Dressel D, Feller-Kopman D. A randomized prospective trial of the utility of rapid on-site evaluation of transbronchial needle aspirate specimens. J Bronchology Interv Pulmonol. 2011;18(2):121–7.CrossRefPubMed
17.
go back to reference Inoue D, Gobara H, Hiraki T, Mimura H, Kato K, Shibamoto K, et al. CT fluoroscopy-guided cutting needle biopsy of focal pure ground-glass opacity lung lesions: diagnostic yield in 83 lesions. Eur J Radiol. 2012;81(2):354–9.CrossRefPubMed Inoue D, Gobara H, Hiraki T, Mimura H, Kato K, Shibamoto K, et al. CT fluoroscopy-guided cutting needle biopsy of focal pure ground-glass opacity lung lesions: diagnostic yield in 83 lesions. Eur J Radiol. 2012;81(2):354–9.CrossRefPubMed
18.
go back to reference Rittirak W, Sompradeekul S. Diagnostic yield of fluoroscopy-guided transbronchial lung biopsy in non-endobronchial lung lesion. J Med Assoc Thai. 2007;90(2):68–73.PubMed Rittirak W, Sompradeekul S. Diagnostic yield of fluoroscopy-guided transbronchial lung biopsy in non-endobronchial lung lesion. J Med Assoc Thai. 2007;90(2):68–73.PubMed
19.
go back to reference Liu C, Pierce LA, Alessio AM, Kinahan PE. The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging. Phys Med Biol. 2009;54(24):7345–62.CrossRefPubMedPubMedCentral Liu C, Pierce LA, Alessio AM, Kinahan PE. The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging. Phys Med Biol. 2009;54(24):7345–62.CrossRefPubMedPubMedCentral
20.
go back to reference Chen A, Pastis N, Furukawa B, Silvestri GA. The effect of respiratory motion on pulmonary nodule location during electromagnetic navigation bronchoscopy. Chest. 2015;147(5):1275–81.CrossRefPubMed Chen A, Pastis N, Furukawa B, Silvestri GA. The effect of respiratory motion on pulmonary nodule location during electromagnetic navigation bronchoscopy. Chest. 2015;147(5):1275–81.CrossRefPubMed
21.
go back to reference Gergel I, Hering J, Tetzlaff R, Meinzer HP, Wegner I. An electromagnetic navigation system for transbronchial interventions with a novel approach to respiratory motion compensation. Med Phys. 2011;38(12):6742–53.CrossRefPubMed Gergel I, Hering J, Tetzlaff R, Meinzer HP, Wegner I. An electromagnetic navigation system for transbronchial interventions with a novel approach to respiratory motion compensation. Med Phys. 2011;38(12):6742–53.CrossRefPubMed
22.
go back to reference Durakovic A, Andersen H, Christiansen A, Hammen I. Retrospective analysis of radial EBUS outcome for the diagnosis of peripheral pulmonary lesion: sensitivity and complications. Eur Clin Respir J. 2015;17(2):28947.CrossRef Durakovic A, Andersen H, Christiansen A, Hammen I. Retrospective analysis of radial EBUS outcome for the diagnosis of peripheral pulmonary lesion: sensitivity and complications. Eur Clin Respir J. 2015;17(2):28947.CrossRef
23.
go back to reference Tay JH, Irving L, Antippa P, Steinfort DP. Radial probe endobronchial ultrasound: factors influencing visualization yield of peripheral pulmonary lesions. Respirology. 2013;18(1):185–90.CrossRefPubMed Tay JH, Irving L, Antippa P, Steinfort DP. Radial probe endobronchial ultrasound: factors influencing visualization yield of peripheral pulmonary lesions. Respirology. 2013;18(1):185–90.CrossRefPubMed
24.
go back to reference Tai R, Dunne RM, Trotman-Dickenson B, Jacobson FL, Madan R, Kumamaru KK, et al. Frequency and severity of pulmonary hemorrhage in patients undergoing percutaneous CT-guided transthoracic lung biopsy: single-institution experience of 1175 Cases. Radiology. 2016;279(1):287–96. Tai R, Dunne RM, Trotman-Dickenson B, Jacobson FL, Madan R, Kumamaru KK, et al. Frequency and severity of pulmonary hemorrhage in patients undergoing percutaneous CT-guided transthoracic lung biopsy: single-institution experience of 1175 Cases. Radiology. 2016;279(1):287–96.
25.
go back to reference Baram D, Garcia RB, Richman PS. Impact of rapid on-site cytologic evaluation during transbronchial needle aspiration. Chest. 2005;128(2):869–75.CrossRefPubMed Baram D, Garcia RB, Richman PS. Impact of rapid on-site cytologic evaluation during transbronchial needle aspiration. Chest. 2005;128(2):869–75.CrossRefPubMed
26.
go back to reference Diacon AH, Schuurmans MM, Theron J, Louw M, Wright CA, Brundyn K, et al. Utility of rapid on-site evaluation of transbronchial needle aspirates. Respiration. 2005;72(2):182–8.CrossRefPubMed Diacon AH, Schuurmans MM, Theron J, Louw M, Wright CA, Brundyn K, et al. Utility of rapid on-site evaluation of transbronchial needle aspirates. Respiration. 2005;72(2):182–8.CrossRefPubMed
27.
go back to reference Celik B, Khoor A, Bulut T, Nassar A. Rapid on-site evaluation has high diagnostic yield differentiating adenocarcinoma vs squamous cell carcinoma of non-small cell lung carcinoma, not otherwise specified subgroup. Pathol Oncol Res. 2015;21(1):167–72.CrossRefPubMed Celik B, Khoor A, Bulut T, Nassar A. Rapid on-site evaluation has high diagnostic yield differentiating adenocarcinoma vs squamous cell carcinoma of non-small cell lung carcinoma, not otherwise specified subgroup. Pathol Oncol Res. 2015;21(1):167–72.CrossRefPubMed
28.
go back to reference Kalluri M, Puttagunta L, Ohinmaa A, Thanh NX, Wong E. Cost analysis of interaprocedural on site evaluation of cytopathology with endobronchial ultrasound. Int J Technol Assess Health Care. 2016;11:1–8. Kalluri M, Puttagunta L, Ohinmaa A, Thanh NX, Wong E. Cost analysis of interaprocedural on site evaluation of cytopathology with endobronchial ultrasound. Int J Technol Assess Health Care. 2016;11:1–8.
29.
go back to reference Karnak D, Ciledag A, Ceyhan K, Atasoy C, Akyar S, Kayacan O. Rapid on-site evaluation and low registration error enhance the success of electromagnetic navigation bronchoscopy. Ann Thorac Med. 2013;8(1):28–32.CrossRefPubMedPubMedCentral Karnak D, Ciledag A, Ceyhan K, Atasoy C, Akyar S, Kayacan O. Rapid on-site evaluation and low registration error enhance the success of electromagnetic navigation bronchoscopy. Ann Thorac Med. 2013;8(1):28–32.CrossRefPubMedPubMedCentral
30.
go back to reference Trisolini R, Cancellieri A, Tinelli C, de Biase D, Valentini I, Casadei G, et al. Randomized trial of endobronchial ultrasound-guided transbronchial needle aspiration with and without rapid on- site evaluation for lung cancer genotyping. Chest. 2015;148(6):1430–7.CrossRefPubMed Trisolini R, Cancellieri A, Tinelli C, de Biase D, Valentini I, Casadei G, et al. Randomized trial of endobronchial ultrasound-guided transbronchial needle aspiration with and without rapid on- site evaluation for lung cancer genotyping. Chest. 2015;148(6):1430–7.CrossRefPubMed
31.
go back to reference Walia R, Madan K, Mohan A, Jain D, Hadda V, Khilnani GC, et al. Diagnostic utility of conventional transbronchial needle aspiration without rapid on-site evaluation in patients with lung cancer. Lung India. 2014;31(3):208–11.CrossRefPubMedPubMedCentral Walia R, Madan K, Mohan A, Jain D, Hadda V, Khilnani GC, et al. Diagnostic utility of conventional transbronchial needle aspiration without rapid on-site evaluation in patients with lung cancer. Lung India. 2014;31(3):208–11.CrossRefPubMedPubMedCentral
32.
go back to reference da Cunha Santos G, Ko HM, Saieg MA, Geddie WR. “The petals and thorns” of ROSE (rapid on-site evaluation). Cancer Cytopathol. 2013;121(1):4–8.CrossRefPubMed da Cunha Santos G, Ko HM, Saieg MA, Geddie WR. “The petals and thorns” of ROSE (rapid on-site evaluation). Cancer Cytopathol. 2013;121(1):4–8.CrossRefPubMed
33.
go back to reference Muller LP, Suffner J, Wenda K, Mohr W, Rommens PM. Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. Injury. 1998;29(6):461–8.CrossRefPubMed Muller LP, Suffner J, Wenda K, Mohr W, Rommens PM. Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. Injury. 1998;29(6):461–8.CrossRefPubMed
34.
go back to reference Ost DE, Ernst A, Lei X, Kovitz KL, Benzaquen S, Diaz-Mendoza J, et al. Diagnostic yield and complications of bronchoscopy for peripheral lung lesions. Results of the AQuIRE registry. Am J Respir Crit Care Med. 2016;193(1):68–77.CrossRefPubMedPubMedCentral Ost DE, Ernst A, Lei X, Kovitz KL, Benzaquen S, Diaz-Mendoza J, et al. Diagnostic yield and complications of bronchoscopy for peripheral lung lesions. Results of the AQuIRE registry. Am J Respir Crit Care Med. 2016;193(1):68–77.CrossRefPubMedPubMedCentral
35.
go back to reference Huang CT, Ruan SY, Liao WY, Kuo YW, Lin CY, Tsai YJ, et al. Risk factors of pneumothorax after endobronchial ultrasound-guided transbronchial biopsy for peripheral lung lesions. PLoS One. 2012;7(11):e49125.CrossRefPubMedPubMedCentral Huang CT, Ruan SY, Liao WY, Kuo YW, Lin CY, Tsai YJ, et al. Risk factors of pneumothorax after endobronchial ultrasound-guided transbronchial biopsy for peripheral lung lesions. PLoS One. 2012;7(11):e49125.CrossRefPubMedPubMedCentral
36.
go back to reference Walsh CJ, Sapkota BH, Kalra MK, Hanumara NC, Liu B, Shepard JA, et al. Smaller and deeper lesions increase the number of acquired scan series incomputed tomography-guided lung biopsy. J Thorac Imaging. 2011;26(3):196–203.CrossRefPubMed Walsh CJ, Sapkota BH, Kalra MK, Hanumara NC, Liu B, Shepard JA, et al. Smaller and deeper lesions increase the number of acquired scan series incomputed tomography-guided lung biopsy. J Thorac Imaging. 2011;26(3):196–203.CrossRefPubMed
Metadata
Title
Small lung lesions invisible under fluoroscopy are located accurately by three-dimensional localization technique on chest wall surface and performed bronchoscopy procedures to increase diagnostic yields
Authors
Chaosheng Deng
Xiaoming Cao
Dawen Wu
Haibo Ding
Ruixiong You
Qunlin Chen
Linying Chen
Xin Zhang
Qiaoxian Zhang
Yongquan Wu
Publication date
01-12-2016
Publisher
BioMed Central
Published in
BMC Pulmonary Medicine / Issue 1/2016
Electronic ISSN: 1471-2466
DOI
https://doi.org/10.1186/s12890-016-0328-8

Other articles of this Issue 1/2016

BMC Pulmonary Medicine 1/2016 Go to the issue