Skip to main content
Top
Published in: BMC Ophthalmology 1/2017

Open Access 01-12-2017 | Research article

Effects of optical diameter of intraocular lenses with intrascleral fixation on higher-order aberrations

Authors: Daisuke Kunita, Makoto Inoue, Yuji Itoh, Naoko Matsuki, Toshiyuki Nagamoto, Akito Hirakata

Published in: BMC Ophthalmology | Issue 1/2017

Login to get access

Abstract

Background

Intrascleral fixation of an intraocular lens (IOL) is used in eyes that lack capsular support. The aim of the study is to determine whether a larger optical diameter IOL will decrease the higher-order aberrations (HOAs) when the haptics are extended for intrascleral fixation than a smaller diameter IOL.

Methods

Three-piece acrylic IOLs with 6.0 mm optics (X-60, VA-60BBR) and 7.0 mm optics (X-70, VA-70 AD) were fixed at lengths of 13, 14, 15, 16, or 17 mm. A wavefront analyzer was used to measure the HOAs within the central 3.0 and 5.2 mm optic diameter.

Results

The astigmatic aberration within the central 5.2 mm was greater than that within the central 3.0 mm for all IOLs. The HOAs increased significantly with an extension of the IOLs with both optical diameters (P < 0.001). The coma aberration within the central 5.2 mm was greater than that within the central 3.0 mm but it did not increase with an extension of the haptics. The astigmatic aberration of the X-60 IOL was significantly greater than that of the X-70 only at an extension of 17 mm. The astigmatic aberration of the VA-70 AD was not significantly different from that of the VA-60BBR. The cylindrical power changed from 0.047 D in the X-60 to 0.118 D in the VA-70 AD when the IOLs were extended from 13 to 17 mm.

Conclusion

When three-piece IOLs are highly extended for intrascleral fixation, the astigmatic aberration increases significantly. However, IOLs with 7 mm optics do not have less astigmatic and coma aberrations than IOLs with 6 mm optics.
Literature
1.
go back to reference Smiddy WE, Ibanez GV, Alfonso E, Flynn HW Jr. Surgical management of dislocated intraocular lenses. J Cataract Refract Surg. 1995;21:64–9.CrossRefPubMed Smiddy WE, Ibanez GV, Alfonso E, Flynn HW Jr. Surgical management of dislocated intraocular lenses. J Cataract Refract Surg. 1995;21:64–9.CrossRefPubMed
2.
go back to reference Wagoner MD, Cox TA, Ariyasu RG, Jacobs DS, Karp CL, American Academy of Ophthalmology. Intraocular lens implantation in the absence of capsular support: a report by the American Academy of Ophthalmology. Ophthalmology. 2003;110:840–59.CrossRefPubMed Wagoner MD, Cox TA, Ariyasu RG, Jacobs DS, Karp CL, American Academy of Ophthalmology. Intraocular lens implantation in the absence of capsular support: a report by the American Academy of Ophthalmology. Ophthalmology. 2003;110:840–59.CrossRefPubMed
3.
go back to reference Por YM, Lavin MJ. Techniques of intraocular lens suspension in the absence of capsular/zonular support. Surv Ophthalmol. 2005;50:429–62.CrossRefPubMed Por YM, Lavin MJ. Techniques of intraocular lens suspension in the absence of capsular/zonular support. Surv Ophthalmol. 2005;50:429–62.CrossRefPubMed
4.
go back to reference Hannush SB. Sutured posterior chamber intraocular lenses: indications and procedure. Curr Opin Ophthalmol. 2000;11:233–40.CrossRefPubMed Hannush SB. Sutured posterior chamber intraocular lenses: indications and procedure. Curr Opin Ophthalmol. 2000;11:233–40.CrossRefPubMed
5.
go back to reference Gabor SG, Pavlidis MM. Sutureless intrascleral posterior chamber intraocular lens fixation. J Cataract Refract Surg. 2007;33:1851–4.CrossRefPubMed Gabor SG, Pavlidis MM. Sutureless intrascleral posterior chamber intraocular lens fixation. J Cataract Refract Surg. 2007;33:1851–4.CrossRefPubMed
6.
go back to reference Agarwal A, Kumar DA, Jacob S, Baid C, Agarwal A, Srinivasan S. Fibrin glue-assisted sutureless posterior chamber intraocular lens implantation in eyes with deficient posterior capsules. J Cataract Refract Surg. 2008;34:1433–8.CrossRefPubMed Agarwal A, Kumar DA, Jacob S, Baid C, Agarwal A, Srinivasan S. Fibrin glue-assisted sutureless posterior chamber intraocular lens implantation in eyes with deficient posterior capsules. J Cataract Refract Surg. 2008;34:1433–8.CrossRefPubMed
7.
go back to reference Scharioth GB, Prasad S, Georgalas I, Tataru C, Pavlidis M. Intermediate results of sutureless intrascleral posterior chamber intraocular lens fixation. J Cataract Refract Surg. 2010;36:254–9.CrossRefPubMed Scharioth GB, Prasad S, Georgalas I, Tataru C, Pavlidis M. Intermediate results of sutureless intrascleral posterior chamber intraocular lens fixation. J Cataract Refract Surg. 2010;36:254–9.CrossRefPubMed
8.
go back to reference Totan Y, Karadag R. Trocar-assisted sutureless intrascleral posterior chamber foldable intra-ocular lens fixation. Eye (Lond). 2012;26:788–91.CrossRef Totan Y, Karadag R. Trocar-assisted sutureless intrascleral posterior chamber foldable intra-ocular lens fixation. Eye (Lond). 2012;26:788–91.CrossRef
9.
go back to reference Akimoto M, Taguchi H, Takahashi T. Using catheter needles to deliver an intraocular lens for intrascleral fixation. J Cataract Refract Surg. 2014;40:179–83.CrossRefPubMed Akimoto M, Taguchi H, Takahashi T. Using catheter needles to deliver an intraocular lens for intrascleral fixation. J Cataract Refract Surg. 2014;40:179–83.CrossRefPubMed
10.
go back to reference Yamane S, Inoue M, Arakawa A, Kadonosono K. Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection. Ophthalmology. 2014;121:61–6.CrossRefPubMed Yamane S, Inoue M, Arakawa A, Kadonosono K. Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection. Ophthalmology. 2014;121:61–6.CrossRefPubMed
11.
go back to reference Ohta T, Toshida H, Murakami A. Simplified and safe method of sutureless intrascleral posterior chamber intraocular lens fixation: Y-fixation technique. J Cataract Refract Surg. 2014;40:2–7.CrossRefPubMed Ohta T, Toshida H, Murakami A. Simplified and safe method of sutureless intrascleral posterior chamber intraocular lens fixation: Y-fixation technique. J Cataract Refract Surg. 2014;40:2–7.CrossRefPubMed
12.
go back to reference Takayama K, Akimoto M, Taguchi H, Nakagawa S, Hiroi K. Transconjunctival sutureless intrascleral intraocular lens fixation using intrascleral tunnels guided with catheter and 30-gauge needles. Br J Ophthalmol. 2015;99:1457–9.CrossRefPubMed Takayama K, Akimoto M, Taguchi H, Nakagawa S, Hiroi K. Transconjunctival sutureless intrascleral intraocular lens fixation using intrascleral tunnels guided with catheter and 30-gauge needles. Br J Ophthalmol. 2015;99:1457–9.CrossRefPubMed
13.
go back to reference Hayashi K, Hayashi H, Nakao F, Hayashi F. Intraocular lens tilt and decentration, anterior chamber depth, and refractive error after trans-scleral suture fixation surgery. Ophthalmology. 1999;106:878–82.CrossRefPubMed Hayashi K, Hayashi H, Nakao F, Hayashi F. Intraocular lens tilt and decentration, anterior chamber depth, and refractive error after trans-scleral suture fixation surgery. Ophthalmology. 1999;106:878–82.CrossRefPubMed
14.
go back to reference Horiguchi L, Garcia PN, Malavazzi GR, Allemann N, Gomes RL. Ultrasound biomicroscopy comparison of ab Interno and ab Externo intraocular lens scleral fixation. J Ophthalmol. 2016;2016:9375091.CrossRefPubMedPubMedCentral Horiguchi L, Garcia PN, Malavazzi GR, Allemann N, Gomes RL. Ultrasound biomicroscopy comparison of ab Interno and ab Externo intraocular lens scleral fixation. J Ophthalmol. 2016;2016:9375091.CrossRefPubMedPubMedCentral
15.
go back to reference Kang DJ, Kim HK. Clinical analysis of the factors contributing to pupillary optic capture after transscleral fixation of posterior chamber intraocular lens for dislocated intraocular lens. J Cataract Refract Surg. 2016;42:1146–50.CrossRefPubMed Kang DJ, Kim HK. Clinical analysis of the factors contributing to pupillary optic capture after transscleral fixation of posterior chamber intraocular lens for dislocated intraocular lens. J Cataract Refract Surg. 2016;42:1146–50.CrossRefPubMed
16.
go back to reference Blum M, Tetz MR, Faller U, Völcker HE. Age-related changes of the ciliary sulcus: implications for implanting sulcus-fixated lenses. J Cataract Refract Surg. 1997;23:91–6.CrossRefPubMed Blum M, Tetz MR, Faller U, Völcker HE. Age-related changes of the ciliary sulcus: implications for implanting sulcus-fixated lenses. J Cataract Refract Surg. 1997;23:91–6.CrossRefPubMed
17.
go back to reference Gao J, Liao RF, Li N. Ciliary sulcus diameters at different anterior chamber depths in highly myopic eyes. J Cataract Refract Surg. 2013;39:1011–6.CrossRefPubMed Gao J, Liao RF, Li N. Ciliary sulcus diameters at different anterior chamber depths in highly myopic eyes. J Cataract Refract Surg. 2013;39:1011–6.CrossRefPubMed
18.
go back to reference Kim KH, Shin HH, Kim HM, Song JS. Correlation between ciliary sulcus diameter measured by 35 MHz ultrasound biomicroscopy and other ocular measurements. J Cataract Refract Surg. 2008;34:632–7.CrossRefPubMed Kim KH, Shin HH, Kim HM, Song JS. Correlation between ciliary sulcus diameter measured by 35 MHz ultrasound biomicroscopy and other ocular measurements. J Cataract Refract Surg. 2008;34:632–7.CrossRefPubMed
19.
go back to reference Petermeier K, Suesskind D, Altpeter E, Schatz A, Messias A, Gekeler F, et al. Sulcus anatomy and diameter in pseudophakic eyes and correlation with biometric data: evaluation with a 50 MHz ultrasound biomicroscope. J Cataract Refract Surg. 2012;38:986–91. Petermeier K, Suesskind D, Altpeter E, Schatz A, Messias A, Gekeler F, et al. Sulcus anatomy and diameter in pseudophakic eyes and correlation with biometric data: evaluation with a 50 MHz ultrasound biomicroscope. J Cataract Refract Surg. 2012;38:986–91.
20.
go back to reference Matsuki N, Inoue M, Itoh Y, Nagamoto T, Hirakata A. Changes in higher-order aberrations of intraocular lenses with intrascleral fixation. Br J Ophthalmol. 2015;99:1732–8.CrossRefPubMed Matsuki N, Inoue M, Itoh Y, Nagamoto T, Hirakata A. Changes in higher-order aberrations of intraocular lenses with intrascleral fixation. Br J Ophthalmol. 2015;99:1732–8.CrossRefPubMed
21.
go back to reference Joannes L, Dubois F, Legros JC. Phase-shifting schlieren: high-resolution quantitative schlieren that uses the phase-shifting technique principle. Appl Opt. 2003;42:5046–53.CrossRefPubMed Joannes L, Dubois F, Legros JC. Phase-shifting schlieren: high-resolution quantitative schlieren that uses the phase-shifting technique principle. Appl Opt. 2003;42:5046–53.CrossRefPubMed
22.
go back to reference Oshika T, Sugita G, Miyata K, Tokunaga T, Samejima T, Okamoto C, et al. Influence of tilt and decentration of scleral-sutured intraocular lens on ocular higher-order wavefront aberration. Br J Ophthalmol. 2007;91:185–8. Oshika T, Sugita G, Miyata K, Tokunaga T, Samejima T, Okamoto C, et al. Influence of tilt and decentration of scleral-sutured intraocular lens on ocular higher-order wavefront aberration. Br J Ophthalmol. 2007;91:185–8.
23.
go back to reference Hayashi K, Hayashi H. Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens capsule. J Cataract Refract Surg. 2005;31:337–42.CrossRefPubMed Hayashi K, Hayashi H. Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens capsule. J Cataract Refract Surg. 2005;31:337–42.CrossRefPubMed
24.
go back to reference Savini G, Barboni P, Ducoli P, Borrelli E, Hoffer KJ. Influence of intraocular lens haptic design on refractive error. J Cataract Refract Surg. 2014;40:1473–8.CrossRefPubMed Savini G, Barboni P, Ducoli P, Borrelli E, Hoffer KJ. Influence of intraocular lens haptic design on refractive error. J Cataract Refract Surg. 2014;40:1473–8.CrossRefPubMed
25.
go back to reference Denoyer A, Ricaud X, Van Went C, Labbé A, Baudouin C. Influence of corneal biomechanical properties on surgically induced astigmatism in cataract surgery. J Cataract Refract Surg. 2013;39:1204–10.CrossRefPubMed Denoyer A, Ricaud X, Van Went C, Labbé A, Baudouin C. Influence of corneal biomechanical properties on surgically induced astigmatism in cataract surgery. J Cataract Refract Surg. 2013;39:1204–10.CrossRefPubMed
26.
go back to reference Can I, Takmaz T, Yildiz Y, Bayhan HA, Soyugelen G, Bostanci B. Coaxial, microcoaxial, and biaxial microincision cataract surgery: prospective comparative study. J Cataract Refract Surg. 2010;36:740–6.CrossRefPubMed Can I, Takmaz T, Yildiz Y, Bayhan HA, Soyugelen G, Bostanci B. Coaxial, microcoaxial, and biaxial microincision cataract surgery: prospective comparative study. J Cataract Refract Surg. 2010;36:740–6.CrossRefPubMed
Metadata
Title
Effects of optical diameter of intraocular lenses with intrascleral fixation on higher-order aberrations
Authors
Daisuke Kunita
Makoto Inoue
Yuji Itoh
Naoko Matsuki
Toshiyuki Nagamoto
Akito Hirakata
Publication date
01-12-2017
Publisher
BioMed Central
Published in
BMC Ophthalmology / Issue 1/2017
Electronic ISSN: 1471-2415
DOI
https://doi.org/10.1186/s12886-017-0478-3

Other articles of this Issue 1/2017

BMC Ophthalmology 1/2017 Go to the issue