Skip to main content
Top
Published in: BMC Pregnancy and Childbirth 1/2015

Open Access 01-12-2015 | Research article

Effect of external airflow resistive load on postural and exercise-associated cardiovascular and pulmonary responses in pregnancy: a case control study

Authors: Jung-Hyun Kim, Raymond J Roberge, Jeffrey B Powell

Published in: BMC Pregnancy and Childbirth | Issue 1/2015

Login to get access

Abstract

Background

Facial coverings (e.g., balaclavas, niqabs, medical/surgical masks, respirators, etc.), that impose low levels of airflow resistive loads, are worn by millions of pregnant women worldwide, but little data exist addressing their impact on pregnancy-associated cardiovascular and pulmonary responses.

Methods

16 pregnant and 16 non-pregnant women were monitored physiologically (heart rate, blood pressure, mean arterial pressure, total peripheral resistance, stroke volume, cardiac output, oxygen saturation, transcutaneous carbon dioxide, fetal heart rate) and subjectively (exertion) for 1 h of mixed sedentary postural activity (sitting, standing) and moderate exercise (bicycle ergometer) with and without wearing N95 filtering facepiece respirators with filter resistive loads of 94.1 Pa (9.6 mm H2O) – 119.6 Pa (12.2 mm H2O) pressure.

Results

The external airflow resistive loads were associated with increases in diastolic pressure (p = 0.004), mean arterial pressure (p = 0.01), and subjective exertion score (p < 0.001) of all study subjects. No significant differences were noted with the external resistive loads between the pregnant and non-pregnant groups for any cardiovascular, pulmonary and subjective variable over 1 h.

Conclusions

Low external airflow resistive loads, during combined sedentary postural activity and moderate exercise over 1 h, were associated with increases in the diastolic and mean arterial pressures of all study subjects, but pregnancy itself was not associated with any significant differences in physiologic or subjective responses to the external airway resistive loads utilized in the study.
Literature
1.
go back to reference Carnevale N, Ducharme MB. Benefits of respiratory heat and moisture exchangers during cold exposures. Defence and Civil Institute of Environmental Medicine Technical Report DCIEM TR. 1999;1999–098:1999. Carnevale N, Ducharme MB. Benefits of respiratory heat and moisture exchangers during cold exposures. Defence and Civil Institute of Environmental Medicine Technical Report DCIEM TR. 1999;1999–098:1999.
2.
go back to reference Rheinhardt TE, Ottmar RD. Baseline measurements of smoke exposure among wildland firefighters. J Occup Environ Hyg. 2004;1:593–606.CrossRef Rheinhardt TE, Ottmar RD. Baseline measurements of smoke exposure among wildland firefighters. J Occup Environ Hyg. 2004;1:593–606.CrossRef
3.
go back to reference Bowen LE. Does that face mask really protect you? Appl Biosafety. 2010;15:67–71.CrossRef Bowen LE. Does that face mask really protect you? Appl Biosafety. 2010;15:67–71.CrossRef
4.
go back to reference Rengasamy S, Eimer B, Shaffer RE. Simple respiratory protection – Evaluation of the filtration performance of cloth masks and common fabric materials against 20–100 nm size particles. Ann Occup Hyg. 2010;54:789–98.CrossRefPubMed Rengasamy S, Eimer B, Shaffer RE. Simple respiratory protection – Evaluation of the filtration performance of cloth masks and common fabric materials against 20–100 nm size particles. Ann Occup Hyg. 2010;54:789–98.CrossRefPubMed
5.
go back to reference Schutz JA, Church JS. Respiratory protection fro physiologically straining environments. Textile Research J. 2011;81:1367–80.CrossRef Schutz JA, Church JS. Respiratory protection fro physiologically straining environments. Textile Research J. 2011;81:1367–80.CrossRef
6.
go back to reference Alghadir A, Aly F, Zafar H. Effect of face veil on ventilator function among Saudi adult females. Pak J Med Sci. 2012;28:71–4. Alghadir A, Aly F, Zafar H. Effect of face veil on ventilator function among Saudi adult females. Pak J Med Sci. 2012;28:71–4.
7.
go back to reference Roberge RJ, Kim J-H, Powell JB, Shaffer RE, Ylitalo CM, Sebastian JM. 2014a. Airflow resistance across filtering facepiece respirators: how low should we go? Int J Occup Environ Med (in press). Roberge RJ, Kim J-H, Powell JB, Shaffer RE, Ylitalo CM, Sebastian JM. 2014a. Airflow resistance across filtering facepiece respirators: how low should we go? Int J Occup Environ Med (in press).
8.
go back to reference Reh CM, Letts D, Deitchman S. Health hazard evaluation report: U.S. Department of the interior national park service. California: Yosemite National Park; 1994. National Institute of Occupational Health and Safety (NIOSH). Reh CM, Letts D, Deitchman S. Health hazard evaluation report: U.S. Department of the interior national park service. California: Yosemite National Park; 1994. National Institute of Occupational Health and Safety (NIOSH).
9.
go back to reference Singh S, Sedgh G, Hussain R. Unintended pregnancy: worldwide levels, trends and outcomes. Studies Fam Plan. 2010;41:241–50.CrossRef Singh S, Sedgh G, Hussain R. Unintended pregnancy: worldwide levels, trends and outcomes. Studies Fam Plan. 2010;41:241–50.CrossRef
10.
go back to reference Silversides CK, Colman J. M. Physiological changes in pregnancy. Sem Anesth Perioperat Med Pain. 2007;19:6–17. Silversides CK, Colman J. M. Physiological changes in pregnancy. Sem Anesth Perioperat Med Pain. 2007;19:6–17.
13.
go back to reference Roberge RJ, Kim J-H, Powell JB, Shaffer RE, Ylitalo CM, Sebastian JM. Impact of low filter resistances on subjective and physiological responses to filtering facepiece respirators. PLoS One. 2013;8:e84901. doi:10:1371/journal.pone.0084901.CrossRefPubMedPubMedCentral Roberge RJ, Kim J-H, Powell JB, Shaffer RE, Ylitalo CM, Sebastian JM. Impact of low filter resistances on subjective and physiological responses to filtering facepiece respirators. PLoS One. 2013;8:e84901. doi:10:1371/journal.pone.0084901.CrossRefPubMedPubMedCentral
14.
go back to reference Roberge RJ, Kim J-H, Powell JB. N95 mask use during pregnancy. Am J Infect Control. 2014;42:265–70.CrossRef Roberge RJ, Kim J-H, Powell JB. N95 mask use during pregnancy. Am J Infect Control. 2014;42:265–70.CrossRef
16.
go back to reference Bogert LWJ, van Lieshout JJ. Non-invasive pulsatile arterial pressure and stroke volume changes from the human finger. Experim Physiol. 2005;90:437–46.CrossRef Bogert LWJ, van Lieshout JJ. Non-invasive pulsatile arterial pressure and stroke volume changes from the human finger. Experim Physiol. 2005;90:437–46.CrossRef
17.
go back to reference Wesseling KH, Jansen JRC, Settels JJ, Schreuder JJ. Computation of aortic flow from pressure in humans using a nonlinear, three-element model. J Appl Physiol. 1993;74:2566–73.PubMed Wesseling KH, Jansen JRC, Settels JJ, Schreuder JJ. Computation of aortic flow from pressure in humans using a nonlinear, three-element model. J Appl Physiol. 1993;74:2566–73.PubMed
18.
go back to reference Borg C. Psychophysical basis of perceived exertion. Med Sci Sport Exerc. 1982;14:377–81. Borg C. Psychophysical basis of perceived exertion. Med Sci Sport Exerc. 1982;14:377–81.
19.
go back to reference Kuo CD, Chen GY, Yang M, Lo HM, Tsai YS. Biphasic changes in autonomic nervous activity during pregnancy. Br J Anaesth. 2000;85:323–9.CrossRef Kuo CD, Chen GY, Yang M, Lo HM, Tsai YS. Biphasic changes in autonomic nervous activity during pregnancy. Br J Anaesth. 2000;85:323–9.CrossRef
20.
go back to reference Lotgering FK, Gilbert RD, Longo LD. Maternal and fetal responses to exercise during pregnancy. Physiol Rev. 1985;65:1–36.PubMed Lotgering FK, Gilbert RD, Longo LD. Maternal and fetal responses to exercise during pregnancy. Physiol Rev. 1985;65:1–36.PubMed
21.
go back to reference Baclaus N. Measurement of baroreflex & sympathetic control of haemodynamics in mid pregnancy by orthostatic test. People’s J Sci Research. 2010;3:1–4. Baclaus N. Measurement of baroreflex & sympathetic control of haemodynamics in mid pregnancy by orthostatic test. People’s J Sci Research. 2010;3:1–4.
22.
go back to reference Ekholm E. Autonomic cardiovascular control in normal and hypertenstive pregnancy. Acta Obstet Gynecol Scand. 1995;74:82–3.CrossRef Ekholm E. Autonomic cardiovascular control in normal and hypertenstive pregnancy. Acta Obstet Gynecol Scand. 1995;74:82–3.CrossRef
23.
go back to reference Thornburg KL, Jacobson SL, Giraud GD, Morton MJ. Hemodynamic changes in pregnancy. Semin Perinatol. 2000;24:11–4.CrossRefPubMed Thornburg KL, Jacobson SL, Giraud GD, Morton MJ. Hemodynamic changes in pregnancy. Semin Perinatol. 2000;24:11–4.CrossRefPubMed
24.
go back to reference Karam M, Wise RA, Natarajan TK, Permutt S, Wagner HN. Mechanism of decreases left ventricular stroke volume during inspiration in man. Circulation. 1984;69:866–73.CrossRefPubMed Karam M, Wise RA, Natarajan TK, Permutt S, Wagner HN. Mechanism of decreases left ventricular stroke volume during inspiration in man. Circulation. 1984;69:866–73.CrossRefPubMed
25.
go back to reference Pildner von Steinberg S, Boulesteix A-L, Lederer C, et al. What is the “normal “ fetal heart rate? PeerJ. 2013;1:e82. doi:10.7717/peerj.82.CrossRef Pildner von Steinberg S, Boulesteix A-L, Lederer C, et al. What is the “normal “ fetal heart rate? PeerJ. 2013;1:e82. doi:10.7717/peerj.82.CrossRef
26.
go back to reference Rafla NM, Cook JR. The effect of maternal exercise on fetal heart rate. J Obstet Gynaecol. 1999;19:381–4.CrossRefPubMed Rafla NM, Cook JR. The effect of maternal exercise on fetal heart rate. J Obstet Gynaecol. 1999;19:381–4.CrossRefPubMed
27.
go back to reference Carballo RB, Stirling JR, Zakynthinaki M, Mulas AL. Acute maternal exercise during the third trimester of pregnancy, influence on foetal heart rate. Rev Internat J Sport Sci. 2008;4:33–43. Carballo RB, Stirling JR, Zakynthinaki M, Mulas AL. Acute maternal exercise during the third trimester of pregnancy, influence on foetal heart rate. Rev Internat J Sport Sci. 2008;4:33–43.
28.
go back to reference Nama V, Antonios TF, Onwude J, Manyonda IT. Mid-trimester blood pressure drop in normal pregnancy: myth or reality? J Hyperstens. 2011;29:763–8.CrossRef Nama V, Antonios TF, Onwude J, Manyonda IT. Mid-trimester blood pressure drop in normal pregnancy: myth or reality? J Hyperstens. 2011;29:763–8.CrossRef
29.
go back to reference Elvan-Taspinar A, Schoot Uiterkamp LAM, Sikkema JM, et al. Validation and use of athe FinoMeter™ for blood pressure measurement in normal, hypertensive and pre-eclamptic pregnancy. J Hypertens. 2003;21:2053–60.CrossRefPubMed Elvan-Taspinar A, Schoot Uiterkamp LAM, Sikkema JM, et al. Validation and use of athe FinoMeter™ for blood pressure measurement in normal, hypertensive and pre-eclamptic pregnancy. J Hypertens. 2003;21:2053–60.CrossRefPubMed
30.
31.
go back to reference Jones J. The physiological cost of wearing a disposable respirator. Am Ind Hyg Assoc J. 1991;52:219–25.CrossRefPubMed Jones J. The physiological cost of wearing a disposable respirator. Am Ind Hyg Assoc J. 1991;52:219–25.CrossRefPubMed
32.
go back to reference Ryan KL, Cooke WH, Rickards CA, Lurie KG, Convertino VA. Breathing through an inspiratory threshold device improves stroke volume during central hypovolemia in humans. J Appl Physiol. 2008;102:1402–9.CrossRef Ryan KL, Cooke WH, Rickards CA, Lurie KG, Convertino VA. Breathing through an inspiratory threshold device improves stroke volume during central hypovolemia in humans. J Appl Physiol. 2008;102:1402–9.CrossRef
33.
go back to reference Roberge RJ, Kim J-H, Coca A. Protective facemask impact on human thermoregulation: an overview. Ann Occup Hyg. 2012;56:102–12.CrossRefPubMed Roberge RJ, Kim J-H, Coca A. Protective facemask impact on human thermoregulation: an overview. Ann Occup Hyg. 2012;56:102–12.CrossRefPubMed
34.
go back to reference Roberge RJ, Kim J-H, Benson SM. Absence of consequential changes in physiological, thermal and subjective responses from wearing a surgical mask. Resp Physiol Neurobiol. 2012;181:29–35.CrossRef Roberge RJ, Kim J-H, Benson SM. Absence of consequential changes in physiological, thermal and subjective responses from wearing a surgical mask. Resp Physiol Neurobiol. 2012;181:29–35.CrossRef
35.
go back to reference Ristuccia HL, Grossman P, Watkins LL, Lown B. Incremental bias in Finapres estimation of baseline blood pressure levels over time. Hypertension. 1997;29:1039–43.CrossRefPubMed Ristuccia HL, Grossman P, Watkins LL, Lown B. Incremental bias in Finapres estimation of baseline blood pressure levels over time. Hypertension. 1997;29:1039–43.CrossRefPubMed
36.
go back to reference Imholz BPM, Wieling W, van Montfrans GA, Wesseling KH. Fifteen years experience with finger arterial pressure monitoring: assessment of the technology. Cardiovasc Research. 1998;38:605–16.CrossRef Imholz BPM, Wieling W, van Montfrans GA, Wesseling KH. Fifteen years experience with finger arterial pressure monitoring: assessment of the technology. Cardiovasc Research. 1998;38:605–16.CrossRef
37.
go back to reference Roberge RJ, Coca A, Williams WJ, Powell JB, Palmiero AJ. Physiological impact of the N95 filtering facepiece respirator on healthcare workers. Resp Care. 2010;55:569–77. Roberge RJ, Coca A, Williams WJ, Powell JB, Palmiero AJ. Physiological impact of the N95 filtering facepiece respirator on healthcare workers. Resp Care. 2010;55:569–77.
38.
go back to reference Wu S, Harber P, Yun D, Bansal S, Li Y, Santiago S. Anxiety during respirator use: comparison of two respirator types. J Occup Environ Hyg. 2011;8:123–8.CrossRefPubMed Wu S, Harber P, Yun D, Bansal S, Li Y, Santiago S. Anxiety during respirator use: comparison of two respirator types. J Occup Environ Hyg. 2011;8:123–8.CrossRefPubMed
Metadata
Title
Effect of external airflow resistive load on postural and exercise-associated cardiovascular and pulmonary responses in pregnancy: a case control study
Authors
Jung-Hyun Kim
Raymond J Roberge
Jeffrey B Powell
Publication date
01-12-2015
Publisher
BioMed Central
Published in
BMC Pregnancy and Childbirth / Issue 1/2015
Electronic ISSN: 1471-2393
DOI
https://doi.org/10.1186/s12884-015-0474-7

Other articles of this Issue 1/2015

BMC Pregnancy and Childbirth 1/2015 Go to the issue