High cut-off membrane for in-vivo dialysis of free plasma hemoglobin in a patient with massive hemolysis

Authors: David Cucchiari, Enric Reverter, Miquel Blasco, Alicia Molina-Andujar, Adriá Carpio, Miquel Sanz, Angels Escorsell, Javier Fernández, Esteban Poch

Published in: BMC Nephrology | Issue 1/2018

Login to get access

Abstract

Background

The possibility of clearing Cell-free Plasma Hemoglobin (CPH) from human plasma may appear attractive, especially when considering the noxious effects that CPH has on the immune function and the renal damage caused by its filtration. The existence of the so-called High Cut-Off (HCO) filters, possessing pores as big as 60 kDa, could potentially allow the clearance of the αβ dimers (31.3 kDa), the form in which the α2β2 hemoglobin tetramers (62.6 kDa) physiologically dissociate in plasma. We present herein the first reported case in which such an attempt was made.

Case presentation

The patient was a 51-year-old man with hemolytic crisis due to glucose-6-phosphate dehydrogenase deficiency, further complicated by pigment-induced nephropathy. He underwent a 48-h CVVHD session, in which a HCO filter was used. The Sieving Coefficient (SC) for CPH was initially 0.08 and decreased to 0.02 after 24 h. This unexpected low SC was due to the initial high concentration of CPH (4.24 g/L). At such concentrations, the α2β2 tetramer poorly dissociates into the αβ dimer; but increases exponentially at concentrations lower than 1 g/L.

Conclusions

Clearance of CPH through a HCO filter is technically feasible but its performance markedly relies on the initial concentration of CPH. Critically ill patients with smoldering hemolysis, as it happens during septic shock or ECMO treatment, may benefit the most from the use of this membrane in order to clear CPH.
Literature
1.
go back to reference Shih HM, Chen YC, Pan CF, Lin HC, Wu CJ, Chen HH. Hemolysis-induced acute kidney injury following cardiac surgery: a case report and review of the literature. Hemodial Int. 2013;17(1):101–6.CrossRef Shih HM, Chen YC, Pan CF, Lin HC, Wu CJ, Chen HH. Hemolysis-induced acute kidney injury following cardiac surgery: a case report and review of the literature. Hemodial Int. 2013;17(1):101–6.CrossRef
2.
go back to reference Bloom O, Wang H, Ivanova S, Vishnubhakat JM, Ombrellino M, Tracey KJ. Hypophysectomy, high tumor necrosis factor levels, and hemoglobinemia in lethal endotoxemic shock. Shock. 1998;10(6):395–400.CrossRef Bloom O, Wang H, Ivanova S, Vishnubhakat JM, Ombrellino M, Tracey KJ. Hypophysectomy, high tumor necrosis factor levels, and hemoglobinemia in lethal endotoxemic shock. Shock. 1998;10(6):395–400.CrossRef
3.
go back to reference Su D, Roth RI, Levin J. Hemoglobin infusion augments the tumor necrosis factor response to bacterial endotoxin (lipopolysaccharide) in mice. Crit Care Med. 1999;27(4):771–8.CrossRef Su D, Roth RI, Levin J. Hemoglobin infusion augments the tumor necrosis factor response to bacterial endotoxin (lipopolysaccharide) in mice. Crit Care Med. 1999;27(4):771–8.CrossRef
4.
go back to reference Adamzik M, Hamburger T, Petrat F, Peters J, de Groot H, Hartmann M. CPH concentration in severe sepsis: methods of measurement and prediction of outcome. Crit Care. 2012;16(4):R125.CrossRef Adamzik M, Hamburger T, Petrat F, Peters J, de Groot H, Hartmann M. CPH concentration in severe sepsis: methods of measurement and prediction of outcome. Crit Care. 2012;16(4):R125.CrossRef
5.
go back to reference Hulko M, Kunz M, Yildirim M, Homeyer S, Amon O, Krause B. Cell-free plasma hemoglobin removal by dialyzers with various permeability profiles. Sci Rep. 2015;5:16367.CrossRef Hulko M, Kunz M, Yildirim M, Homeyer S, Amon O, Krause B. Cell-free plasma hemoglobin removal by dialyzers with various permeability profiles. Sci Rep. 2015;5:16367.CrossRef
6.
go back to reference Bunn HF, Esham WT, Bull RW. The renal handling of hemoglobin. I. Glomerular filtration. J Exp Med. 1969;129(5):909–23.CrossRef Bunn HF, Esham WT, Bull RW. The renal handling of hemoglobin. I. Glomerular filtration. J Exp Med. 1969;129(5):909–23.CrossRef
7.
go back to reference Haase M, Bellomo R, Baldwin I, et al. Hemodialysis membrane with a high-molecular-weight cutoff and cytokine levels in sepsis complicated by acute renal failure: a phase 1 randomized trial. Am J Kidney Dis. 2007;50(2):296–304.CrossRef Haase M, Bellomo R, Baldwin I, et al. Hemodialysis membrane with a high-molecular-weight cutoff and cytokine levels in sepsis complicated by acute renal failure: a phase 1 randomized trial. Am J Kidney Dis. 2007;50(2):296–304.CrossRef
8.
go back to reference Morgera S, Klonower D, Rocktäschel J, et al. TNF-alpha elimination with high cut-off haemofilters: a feasible clinical modality for septic patients? Nephrol Dial Transplant. 2003;18(7):1361–9.CrossRef Morgera S, Klonower D, Rocktäschel J, et al. TNF-alpha elimination with high cut-off haemofilters: a feasible clinical modality for septic patients? Nephrol Dial Transplant. 2003;18(7):1361–9.CrossRef
9.
go back to reference Morgera S, Haase M, Rocktäschel J, et al. High permeability haemofiltration improves peripheral blood mononuclear cell proliferation in septic patients with acute renal failure. Nephrol Dial Transplant. 2003;18(12):2570–6.CrossRef Morgera S, Haase M, Rocktäschel J, et al. High permeability haemofiltration improves peripheral blood mononuclear cell proliferation in septic patients with acute renal failure. Nephrol Dial Transplant. 2003;18(12):2570–6.CrossRef
10.
go back to reference Morgera S, Haase M, Kuss T, et al. Pilot study on the effects of high cutoff hemofiltration on the need for norepinephrine in septic patients with acute renal failure. Crit Care Med. 2006;34(8):2099–104.CrossRef Morgera S, Haase M, Kuss T, et al. Pilot study on the effects of high cutoff hemofiltration on the need for norepinephrine in septic patients with acute renal failure. Crit Care Med. 2006;34(8):2099–104.CrossRef
11.
go back to reference Cornelius AM, Riley JB, Schears GJ, Burkhart HM. Plasma-free hemoglobin levels in advanced vs. conventional infant and pediatric extracorporeal life support circuits. J Extra Corpor Technol. 2013;45(1):21–5.PubMedPubMedCentral Cornelius AM, Riley JB, Schears GJ, Burkhart HM. Plasma-free hemoglobin levels in advanced vs. conventional infant and pediatric extracorporeal life support circuits. J Extra Corpor Technol. 2013;45(1):21–5.PubMedPubMedCentral
Metadata
Title
High cut-off membrane for in-vivo dialysis of free plasma hemoglobin in a patient with massive hemolysis
Authors
David Cucchiari
Enric Reverter
Miquel Blasco
Alicia Molina-Andujar
Adriá Carpio
Miquel Sanz
Angels Escorsell
Javier Fernández
Esteban Poch
Publication date
01-12-2018
Publisher
BioMed Central
Published in
BMC Nephrology / Issue 1/2018
Electronic ISSN: 1471-2369
DOI
https://doi.org/10.1186/s12882-018-1051-x

Other articles of this Issue 1/2018

BMC Nephrology 1/2018 Go to the issue