Abstract

Background

In this study, we explored how various preprocessing approaches can be employed to enhance the capability of dental CBCT to accurately estimate trabecular bone microarchitectural parameters.

Methods

In total, 30 bovine vertebrae cancellous bone specimens were used for in study. Voxel resolution 18-μm micro-computed tomography (micro-CT) and 100-μm dental CBCT were used to scan each specimen. Micro-CT images were used to calculate trabecular bone microarchitectural parameters; the results were set as the gold standard. Subsequently, before the dental CBCT images were converted into binary images to calculate trabecular bone microarchitectural parameters, three preprocessing approaches were used to process the dental CBCT images. For Group 1, no preprocessing approach was applied. For Group 2, images were sharpened and despeckable noises were removed. For Group 3, the function of local thresholding was added to Group 2 to form Group 3. For Group 4, the air pixels was removed from Group 3 to form Group 4. Subsequently, all images were imported into a software package to estimate trabecular bone microarchitectural parameters (bone volume fraction (BV/TV), trabecular thickness (TbTh), trabecular number (TbN), and trabecular separation (TbSp)). Finally, a paired t-test and a Pearson correlation test were performed to compare the capability of micro-CT with the capability of dental CBCT for estimating trabecular bone microarchitectural parameters.

Results

Regardless of whether dental CBCT images underwent image preprocessing (Groups 1 to 4), the four trabecular bone microarchitectural parameters measured using dental CBCT images were significantly different from those measured using micro-CT images. However, after three image preprocessing approaches were applied to the dental CBCT images (Group 4), the BV/TV obtained using dental CBCT was highly positively correlated with that obtained using micro-CT (r = 0.87, p < 0.001); the correlation coefficient was greater than that of Group 1 (r = −0.15, p = 0.412), Group 2 (r = 0.16, p = 0.386), and Group 3 (r = 0.47, p = 0.006). After dental CBCT images underwent image preprocessing, the efficacy of using dental CBCT for estimating TbN and TbSp was enhanced.

Conclusions

Image preprocessing approaches can be used to enhance the efficacy of using dental CBCT for predicting trabecular bone microarchitectural parameters.
Literature
1.
go back to reference Keaveny TM, Morgan EF, Niebur GL, Yeh OC. Biomechanics of trabecular bone. Annu Rev Biomed Eng. 2001;3(1):307–33.CrossRef Keaveny TM, Morgan EF, Niebur GL, Yeh OC. Biomechanics of trabecular bone. Annu Rev Biomed Eng. 2001;3(1):307–33.CrossRef
2.
go back to reference Ho JT, Wu J, Huang HL, Chen MY, Fuh LJ, Hsu JT. Trabecular bone structural parameters evaluated using dental cone-beam computed tomography: cellular synthetic bones. Biomed Eng Online. 2013;12:115.CrossRef Ho JT, Wu J, Huang HL, Chen MY, Fuh LJ, Hsu JT. Trabecular bone structural parameters evaluated using dental cone-beam computed tomography: cellular synthetic bones. Biomed Eng Online. 2013;12:115.CrossRef
3.
go back to reference Hsu JT, Wang SP, Huang HL, Chen YJ, Wu J, Tsai MT. The assessment of trabecular bone parameters and cortical bone strength: a comparison of micro-CT and dental cone-beam CT. J Biomech. 2013;46(15):2611–8.CrossRef Hsu JT, Wang SP, Huang HL, Chen YJ, Wu J, Tsai MT. The assessment of trabecular bone parameters and cortical bone strength: a comparison of micro-CT and dental cone-beam CT. J Biomech. 2013;46(15):2611–8.CrossRef
4.
go back to reference Gibson L. The mechanical behaviour of cancellous bone. J Biomech. 1985;18(5):317–28.CrossRef Gibson L. The mechanical behaviour of cancellous bone. J Biomech. 1985;18(5):317–28.CrossRef
5.
go back to reference Donnelly E. Methods for assessing bone quality: a review. Clin Orthop Relat Res. 2011;469(8):2128–38.CrossRef Donnelly E. Methods for assessing bone quality: a review. Clin Orthop Relat Res. 2011;469(8):2128–38.CrossRef
6.
go back to reference Cendre E, Mitton D, Roux J-P, Arlot M, Duboeuf F, Burt-Pichat B, Rumelhart C, Peix G, Meunier P. High-resolution computed tomography for architectural characterization of human lumbar cancellous bone: relationships with histomorphometry and biomechanics. Osteoporos Int. 1999;10(5):353–60.CrossRef Cendre E, Mitton D, Roux J-P, Arlot M, Duboeuf F, Burt-Pichat B, Rumelhart C, Peix G, Meunier P. High-resolution computed tomography for architectural characterization of human lumbar cancellous bone: relationships with histomorphometry and biomechanics. Osteoporos Int. 1999;10(5):353–60.CrossRef
7.
go back to reference Bouxsein ML, Boyd SK, Christiansen BA, Guldberg RE, Jepsen KJ, Müller R. Guidelines for assessment of bone microstructure in rodents using micro–computed tomography. J Bone Miner Res. 2010;25(7):1468–86.CrossRef Bouxsein ML, Boyd SK, Christiansen BA, Guldberg RE, Jepsen KJ, Müller R. Guidelines for assessment of bone microstructure in rodents using micro–computed tomography. J Bone Miner Res. 2010;25(7):1468–86.CrossRef
8.
go back to reference Doube M, Kłosowski MM, Arganda-Carreras I, Cordelières FP, Dougherty RP, Jackson JS, Schmid B, Hutchinson JR, Shefelbine SJ. BoneJ: free and extensible bone image analysis in ImageJ. Bone. 2010;47(6):1076–9.CrossRef Doube M, Kłosowski MM, Arganda-Carreras I, Cordelières FP, Dougherty RP, Jackson JS, Schmid B, Hutchinson JR, Shefelbine SJ. BoneJ: free and extensible bone image analysis in ImageJ. Bone. 2010;47(6):1076–9.CrossRef
9.
go back to reference Benavides E, Rios HF, Ganz SD, An C-H, Resnik R, Reardon GT, Feldman SJ, Mah JK, Hatcher D, Kim MJ. Use of cone beam computed tomography in implant dentistry: the international congress of Oral Implantologists consensus report. Implant Dent. 2012;21(2):78–86.CrossRef Benavides E, Rios HF, Ganz SD, An C-H, Resnik R, Reardon GT, Feldman SJ, Mah JK, Hatcher D, Kim MJ. Use of cone beam computed tomography in implant dentistry: the international congress of Oral Implantologists consensus report. Implant Dent. 2012;21(2):78–86.CrossRef
10.
go back to reference Dawood A, Brown J, Sauret-Jackson V, Purkayastha S. Optimization of cone beam CT exposure for pre-surgical evaluation of the implant site. Dentomaxillofac Radiol. 2012;41(1):70–4.CrossRef Dawood A, Brown J, Sauret-Jackson V, Purkayastha S. Optimization of cone beam CT exposure for pre-surgical evaluation of the implant site. Dentomaxillofac Radiol. 2012;41(1):70–4.CrossRef
11.
go back to reference Hsu JT, Chen YJ, Ho JT, Huang HL, Wang SP, Cheng FC, Wu J, Tsai MT. A comparison of micro-CT and dental CT in assessing cortical bone morphology and trabecular bone microarchitecture. PLoS One. 2014;9(9):e107545.CrossRef Hsu JT, Chen YJ, Ho JT, Huang HL, Wang SP, Cheng FC, Wu J, Tsai MT. A comparison of micro-CT and dental CT in assessing cortical bone morphology and trabecular bone microarchitecture. PLoS One. 2014;9(9):e107545.CrossRef
12.
go back to reference Eggmann F, Connert T, Bühler J, Dagassan-Berndt D, Weiger R, Walter C. Do periapical and periodontal pathologies affect Schneiderian membrane appearance? Systematic review of studies using cone-beam computed tomography. Clin Oral Investig. 2017;21(5):1611–30.CrossRef Eggmann F, Connert T, Bühler J, Dagassan-Berndt D, Weiger R, Walter C. Do periapical and periodontal pathologies affect Schneiderian membrane appearance? Systematic review of studies using cone-beam computed tomography. Clin Oral Investig. 2017;21(5):1611–30.CrossRef
13.
go back to reference Benic GI, Elmasry M, Hämmerle CH. Novel digital imaging techniques to assess the outcome in oral rehabilitation with dental implants: a narrative review. Clin Orthop Relat Res. 2015;26(S11):86–96. Benic GI, Elmasry M, Hämmerle CH. Novel digital imaging techniques to assess the outcome in oral rehabilitation with dental implants: a narrative review. Clin Orthop Relat Res. 2015;26(S11):86–96.
14.
go back to reference Parsa A, Ibrahim N, Hassan B, Stelt P, Wismeijer D. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT. Clin Orthop Relat Res. 2015;26(1):e1–7. Parsa A, Ibrahim N, Hassan B, Stelt P, Wismeijer D. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT. Clin Orthop Relat Res. 2015;26(1):e1–7.
15.
go back to reference Hao Y, Zhao W, Wang Y, Yu J, Zou D. Assessments of jaw bone density at implant sites using 3D cone-beam computed tomography. Eur Rev Med Pharmacol Sci. 2014;18(9):1398–403.PubMed Hao Y, Zhao W, Wang Y, Yu J, Zou D. Assessments of jaw bone density at implant sites using 3D cone-beam computed tomography. Eur Rev Med Pharmacol Sci. 2014;18(9):1398–403.PubMed
16.
go back to reference Loveless TP, Kilinc Y, Altay MA, Flores-Hidalgo A, Baur DA, Quereshy FA. Hounsfield unit comparison of grafted versus non-grafted extraction sockets. J Oral Sci. 2015;57(3):195–200.CrossRef Loveless TP, Kilinc Y, Altay MA, Flores-Hidalgo A, Baur DA, Quereshy FA. Hounsfield unit comparison of grafted versus non-grafted extraction sockets. J Oral Sci. 2015;57(3):195–200.CrossRef
17.
go back to reference Van Dessel J, Nicolielo L, Huang Y, Slagmolen P, Politis C, Lambrichts I, Jacobs R. Quantification of bone quality using different cone beam computed tomography devices: accuracy assessment for edentulous human mandibles. Eur J Oral Implantol. 2016;9(4):411–24.PubMed Van Dessel J, Nicolielo L, Huang Y, Slagmolen P, Politis C, Lambrichts I, Jacobs R. Quantification of bone quality using different cone beam computed tomography devices: accuracy assessment for edentulous human mandibles. Eur J Oral Implantol. 2016;9(4):411–24.PubMed
18.
go back to reference Mullender M, Huiskes R, Versleyen H, Buma P. Osteocyte density and histomorphometric parameters in cancellous bone of the proximal femur in five mammalian species. J Orthop Res. 1996;14(6):972–9.CrossRef Mullender M, Huiskes R, Versleyen H, Buma P. Osteocyte density and histomorphometric parameters in cancellous bone of the proximal femur in five mammalian species. J Orthop Res. 1996;14(6):972–9.CrossRef
19.
go back to reference Ito M, Nakamura T, Matsumoto T, Tsurusaki K, Hayashi K. Analysis of trabecular microarchitecture of human iliac bone using microcomputed tomography in patients with hip arthrosis with or without vertebral fracture. Bone. 1998;23(2):163–9.CrossRef Ito M, Nakamura T, Matsumoto T, Tsurusaki K, Hayashi K. Analysis of trabecular microarchitecture of human iliac bone using microcomputed tomography in patients with hip arthrosis with or without vertebral fracture. Bone. 1998;23(2):163–9.CrossRef
20.
go back to reference Hara T, Tanck E, Homminga J, Huiskes R. The influence of microcomputed tomography threshold variations on the assessment of structural and mechanical trabecular bone properties. Bone. 2002;31(1):107–9.CrossRef Hara T, Tanck E, Homminga J, Huiskes R. The influence of microcomputed tomography threshold variations on the assessment of structural and mechanical trabecular bone properties. Bone. 2002;31(1):107–9.CrossRef
21.
go back to reference Rüegsegger P, Koller B, Müller R. A microtomographic system for the nondestructive evaluation of bone architecture. Calcif Tissue Int. 1996;58(1):24–9.CrossRef Rüegsegger P, Koller B, Müller R. A microtomographic system for the nondestructive evaluation of bone architecture. Calcif Tissue Int. 1996;58(1):24–9.CrossRef
22.
go back to reference Ibrahim N, Parsa A, Hassan B, Stelt P, Aartman IH, Wismeijer D. Accuracy of trabecular bone microstructural measurement at planned dental implant sites using cone-beam CT datasets. Clin Oral Implants Res. 2014;25(8):941–5.CrossRef Ibrahim N, Parsa A, Hassan B, Stelt P, Aartman IH, Wismeijer D. Accuracy of trabecular bone microstructural measurement at planned dental implant sites using cone-beam CT datasets. Clin Oral Implants Res. 2014;25(8):941–5.CrossRef
23.
go back to reference Kim JE, Yi WJ, Heo MS, Lee SS, Choi SC, Huh KH. Three-dimensional evaluation of human jaw bone microarchitecture: correlation between the microarchitectural parameters of cone beam computed tomography and micro-computer tomography. Oral Surg Oral Med Oral Pathol Oral Radiol. 2015;120(6):762–70.CrossRef Kim JE, Yi WJ, Heo MS, Lee SS, Choi SC, Huh KH. Three-dimensional evaluation of human jaw bone microarchitecture: correlation between the microarchitectural parameters of cone beam computed tomography and micro-computer tomography. Oral Surg Oral Med Oral Pathol Oral Radiol. 2015;120(6):762–70.CrossRef
24.
go back to reference Van Dessel J, Huang Y, Depypere M, Rubira-Bullen I, Maes F, Jacobs R. A comparative evaluation of cone beam CT and micro-CT on trabecular bone structures in the human mandible. Dentomaxillofac Radiol. 2013;42(8):20130145.CrossRef Van Dessel J, Huang Y, Depypere M, Rubira-Bullen I, Maes F, Jacobs R. A comparative evaluation of cone beam CT and micro-CT on trabecular bone structures in the human mandible. Dentomaxillofac Radiol. 2013;42(8):20130145.CrossRef
25.
go back to reference de Groot R, Oomens M, Forouzanfar T, Schulten E. Bone augmentation followed by implant surgery in the edentulous mandible: a systematic review. J Oral Rehabil. 2018;45(4):334-43. de Groot R, Oomens M, Forouzanfar T, Schulten E. Bone augmentation followed by implant surgery in the edentulous mandible: a systematic review. J Oral Rehabil. 2018;45(4):334-43.
26.
go back to reference Lee CT, Chen YW, Starr JR, Chuang SK. Survival analysis of wide dental implant: systematic review and meta-analysis. Clin Oral Implants Res. 2016;27(10):1251–64.CrossRef Lee CT, Chen YW, Starr JR, Chuang SK. Survival analysis of wide dental implant: systematic review and meta-analysis. Clin Oral Implants Res. 2016;27(10):1251–64.CrossRef
27.
go back to reference Ko YC, Huang HL, Shen YW, Cai JY, Fuh LJ, Hsu JT. Variations in crestal cortical bone thickness at dental implant sites in different regions of the jawbone. Clin Implant Dent Relat Res. 2017;19(3):440–6.CrossRef Ko YC, Huang HL, Shen YW, Cai JY, Fuh LJ, Hsu JT. Variations in crestal cortical bone thickness at dental implant sites in different regions of the jawbone. Clin Implant Dent Relat Res. 2017;19(3):440–6.CrossRef
28.
go back to reference Fuh LJ, Huang HL, Chen CS, Fu KL, Shen YW, Tu MG, Shen W, Hsu JT. Variations in bone density at dental implant sites in different regions of the jawbone. J Oral Rehabil. 2010;37(5):346–51.CrossRef Fuh LJ, Huang HL, Chen CS, Fu KL, Shen YW, Tu MG, Shen W, Hsu JT. Variations in bone density at dental implant sites in different regions of the jawbone. J Oral Rehabil. 2010;37(5):346–51.CrossRef
29.
go back to reference Panmekiate S, Ngonphloy N, Charoenkarn T, Faruangsaeng T, Pauwels R. Comparison of mandibular bone microarchitecture between micro-CT and CBCT images. Dentomaxillofac Radiol. 2015;44(5):20140322.CrossRef Panmekiate S, Ngonphloy N, Charoenkarn T, Faruangsaeng T, Pauwels R. Comparison of mandibular bone microarchitecture between micro-CT and CBCT images. Dentomaxillofac Radiol. 2015;44(5):20140322.CrossRef
30.
go back to reference Pauwels R, Faruangsaeng T, Charoenkarn T, Ngonphloy N, Panmekiate S. Effect of exposure parameters and voxel size on bone structure analysis in CBCT. Dentomaxillofac Radiol. 2015;44(8):20150078.CrossRef Pauwels R, Faruangsaeng T, Charoenkarn T, Ngonphloy N, Panmekiate S. Effect of exposure parameters and voxel size on bone structure analysis in CBCT. Dentomaxillofac Radiol. 2015;44(8):20150078.CrossRef
31.
go back to reference Naitoh M, Aimiya H, Hirukawa A, Ariji E. Morphometric analysis of mandibular trabecular bone using cone beam computed tomography: an in vitro study. Int J Oral Maxillofac Implants. 2010;25(6):1093–8.PubMed Naitoh M, Aimiya H, Hirukawa A, Ariji E. Morphometric analysis of mandibular trabecular bone using cone beam computed tomography: an in vitro study. Int J Oral Maxillofac Implants. 2010;25(6):1093–8.PubMed
32.
go back to reference Kang SR, Bok SC, Choi SC, Lee SS, Heo MS, Huh KH, Kim TI, Yi WJ. The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography. J Periodontal Implant Sci. 2016;46(2):116–27.CrossRef Kang SR, Bok SC, Choi SC, Lee SS, Heo MS, Huh KH, Kim TI, Yi WJ. The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography. J Periodontal Implant Sci. 2016;46(2):116–27.CrossRef
33.
go back to reference Ibrahim N, Parsa A, Hassan B, van der Stelt P, Aartman IH, Nambiar P. Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study. Dentomaxillofac Radiol. 2014;43(2):20130329.CrossRef Ibrahim N, Parsa A, Hassan B, van der Stelt P, Aartman IH, Nambiar P. Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study. Dentomaxillofac Radiol. 2014;43(2):20130329.CrossRef
34.
go back to reference Ibrahim N. Assessment of Trabecular Bone Microstructure using Dental Cone Beam CT: Thesis of Vrige University Amsterdam; 2014. p. 98–109. Ibrahim N. Assessment of Trabecular Bone Microstructure using Dental Cone Beam CT: Thesis of Vrige University Amsterdam; 2014. p. 98–109.
35.
go back to reference Ibrahim N, Parsa A, Hassan B, Van der Stelt P, Wismeijer D. Diagnostic imaging of trabecular bone microstructure for oral implants: a literature review. Dentomaxillofac Radiol. 2013;42(3):20120075.CrossRef Ibrahim N, Parsa A, Hassan B, Van der Stelt P, Wismeijer D. Diagnostic imaging of trabecular bone microstructure for oral implants: a literature review. Dentomaxillofac Radiol. 2013;42(3):20120075.CrossRef
36.
go back to reference Huang Y, Dessel J, Liang X, Depypere M, Zhong W, Ma G, Lambrichts I, Maes F, Jacobs R. Effects of immediate and delayed loading on Peri-implant trabecular structures: a cone beam CT evaluation. Clin Implant Dent Relat Res. 2014;16(6):873–83.CrossRef Huang Y, Dessel J, Liang X, Depypere M, Zhong W, Ma G, Lambrichts I, Maes F, Jacobs R. Effects of immediate and delayed loading on Peri-implant trabecular structures: a cone beam CT evaluation. Clin Implant Dent Relat Res. 2014;16(6):873–83.CrossRef
37.
go back to reference Klintström E, Smedby Ö, Moreno R, Brismar TB. Trabecular bone structure parameters from 3D image processing of clinical multi-slice and cone-beam computed tomography data. Skelet Radiol. 2014;43(2):197–204.CrossRef Klintström E, Smedby Ö, Moreno R, Brismar TB. Trabecular bone structure parameters from 3D image processing of clinical multi-slice and cone-beam computed tomography data. Skelet Radiol. 2014;43(2):197–204.CrossRef
38.
go back to reference Tsai WH. Moment-preserving thresolding: a new approach. Comput Vis Graph Image Process. 1985;29(3):377–93.CrossRef Tsai WH. Moment-preserving thresolding: a new approach. Comput Vis Graph Image Process. 1985;29(3):377–93.CrossRef
Metadata
Title
Improving the prediction of the trabecular bone microarchitectural parameters using dental cone-beam computed tomography
Authors
Rong-Ting He
Ming-Gene Tu
Heng-Li Huang
Ming-Tzu Tsai
Jay Wu
Jui-Ting Hsu
Publication date
01-12-2019
Publisher
BioMed Central
Published in
BMC Medical Imaging / Issue 1/2019
Electronic ISSN: 1471-2342
DOI
https://doi.org/10.1186/s12880-019-0313-9

Other articles of this Issue 1/2019

BMC Medical Imaging 1/2019 Go to the issue