Skip to main content
Top
Published in: BMC Infectious Diseases 1/2018

Open Access 01-12-2018 | Research article

Environmental disinfection with photocatalyst as an adjunctive measure to control transmission of methicillin-resistant Staphylococcus aureus: a prospective cohort study in a high-incidence setting

Authors: Min Hyung Kim, Seong Gyu Lee, Ki Sook Kim, Yoon Ji Heo, Ji Eun Oh, Su Jin Jeong

Published in: BMC Infectious Diseases | Issue 1/2018

Login to get access

Abstract

Background

Environmental disinfection with continuously antimicrobial surfaces could offer superior control of surface bioburden. We sought to decide the efficacy of photocatalyst antimicrobial coating in reducing methicillin-resistant Staphylococcus aureus (MRSA) acquisition in high incidence setting.

Methods

We performed prospective cohort study involving patients hospitalized in medical intensive care unit. A titanium dioxide-based photocatalyst was coated on high touch surfaces and walls. Five months of pre-intervention data were compared with five months of post-intervention data. The incidence rates of multidrug-resistant organism acquisition and the rates of hospital-acquired blood stream infection, pneumonia, urinary tract infection, and Clostridium difficile–associated diseases were compared using Cox proportional hazards regression analysis.

Results

In total, 621 patients were included. There was significant decrease in MRSA acquisition rate after photocatalyst coating (hazard ratio, 0.37; 95% confidence interval, 0.14–0.99; p = 0.04). However, clinical identification of vancomycin-resistant Enterococcus spp. and multidrug-resistant Acinetobacter baumannii did not decrease significantly. The hazard of contracting hospital-acquired pneumonia during the intervention period compared to baseline period was 0.46 (95% confidence interval, 0.23–0.94; p = 0.03).

Conclusions

In conclusion, MRSA rate was significantly reduced after photocatalyst coating. We provide evidence that photocatalyst disinfection can be an adjunctive measure to control MRSA acquisition in high-incidence settings.

Trial registration

ISRCTN Registry (ISRCTN31972004). Registered retrospectively on November 19, 2018.
Appendix
Available only for authorised users
Literature
1.
go back to reference Smith PW, Bennett G, Bradley S, Drinka P, Lautenbach E, Marx J, Mody L, Nicolle L, Stevenson K, Society for Healthcare Epidemiology of America, et al. SHEA/APIC guideline: infection prevention and control in the long-term care facility. Am J Infect Control. 2008;36(7):504–35.CrossRefPubMedPubMedCentral Smith PW, Bennett G, Bradley S, Drinka P, Lautenbach E, Marx J, Mody L, Nicolle L, Stevenson K, Society for Healthcare Epidemiology of America, et al. SHEA/APIC guideline: infection prevention and control in the long-term care facility. Am J Infect Control. 2008;36(7):504–35.CrossRefPubMedPubMedCentral
2.
go back to reference Grundmann H, Aires-de-Sousa M, Boyce J, Tiemersma E. Emergence and resurgence of meticillin-resistant Staphylococcus aureus as a public-health threat. Lancet (London, England). 2006;368(9538):874–85.CrossRef Grundmann H, Aires-de-Sousa M, Boyce J, Tiemersma E. Emergence and resurgence of meticillin-resistant Staphylococcus aureus as a public-health threat. Lancet (London, England). 2006;368(9538):874–85.CrossRef
3.
go back to reference Furuno JP, Hebden JN, Standiford HC, Perencevich EN, Miller RR, Moore AC, Strauss SM, Harris AD. Prevalence of methicillin-resistant Staphylococcus aureus and Acinetobacter baumannii in a long-term acute care facility. Am J Infect Control. 2008;36(7):468–71.CrossRefPubMedPubMedCentral Furuno JP, Hebden JN, Standiford HC, Perencevich EN, Miller RR, Moore AC, Strauss SM, Harris AD. Prevalence of methicillin-resistant Staphylococcus aureus and Acinetobacter baumannii in a long-term acute care facility. Am J Infect Control. 2008;36(7):468–71.CrossRefPubMedPubMedCentral
4.
go back to reference Calfee DP, Salgado CD, Milstone AM, Harris AD, Kuhar DT, Moody J, Aureden K, Huang SS, Maragakis LL, Yokoe DS. Strategies to prevent methicillin-resistant Staphylococcus aureus transmission and infection in acute care hospitals: 2014 update. Infect Control Hosp Epidemiol. 2014;35(Suppl 2):S108–32.CrossRefPubMed Calfee DP, Salgado CD, Milstone AM, Harris AD, Kuhar DT, Moody J, Aureden K, Huang SS, Maragakis LL, Yokoe DS. Strategies to prevent methicillin-resistant Staphylococcus aureus transmission and infection in acute care hospitals: 2014 update. Infect Control Hosp Epidemiol. 2014;35(Suppl 2):S108–32.CrossRefPubMed
5.
go back to reference Marra AR, Edmond MB, Schweizer ML, Ryan GW, Diekema DJ. Discontinuing contact precautions for multidrug-resistant organisms: a systematic literature review and meta-analysis. Am J Infect Control. 2018;46(3):333–40.CrossRefPubMed Marra AR, Edmond MB, Schweizer ML, Ryan GW, Diekema DJ. Discontinuing contact precautions for multidrug-resistant organisms: a systematic literature review and meta-analysis. Am J Infect Control. 2018;46(3):333–40.CrossRefPubMed
6.
go back to reference Hardy KJ, Oppenheim BA, Gossain S, Gao F, Hawkey PM. A study of the relationship between environmental contamination with methicillin-resistant Staphylococcus aureus (MRSA) and patients' acquisition of MRSA. Infect Control Hosp Epidemiol. 2006;27(2):127–32.CrossRefPubMed Hardy KJ, Oppenheim BA, Gossain S, Gao F, Hawkey PM. A study of the relationship between environmental contamination with methicillin-resistant Staphylococcus aureus (MRSA) and patients' acquisition of MRSA. Infect Control Hosp Epidemiol. 2006;27(2):127–32.CrossRefPubMed
7.
go back to reference Dancer SJ. Importance of the environment in meticillin-resistant Staphylococcus aureus acquisition: the case for hospital cleaning. Lancet Infect Dis. 2008;8(2):101–13.CrossRefPubMed Dancer SJ. Importance of the environment in meticillin-resistant Staphylococcus aureus acquisition: the case for hospital cleaning. Lancet Infect Dis. 2008;8(2):101–13.CrossRefPubMed
8.
go back to reference Boyce JM. Environmental contamination makes an important contribution to hospital infection. J Hosp Infect. 2007;65(Suppl 2):50–4.CrossRefPubMed Boyce JM. Environmental contamination makes an important contribution to hospital infection. J Hosp Infect. 2007;65(Suppl 2):50–4.CrossRefPubMed
9.
go back to reference Hota B. Contamination, disinfection, and cross-colonization: are hospital surfaces reservoirs for nosocomial infection? Clin Infect Dis. 2004;39(8):1182–9.CrossRefPubMed Hota B. Contamination, disinfection, and cross-colonization: are hospital surfaces reservoirs for nosocomial infection? Clin Infect Dis. 2004;39(8):1182–9.CrossRefPubMed
10.
go back to reference Bartels MD, Kristoffersen K, Slotsbjerg T, Rohde SM, Lundgren B, Westh H. Environmental meticillin-resistant Staphylococcus aureus (MRSA) disinfection using dry-mist-generated hydrogen peroxide. J Hosp Infect. 2008;70(1):35–41.CrossRefPubMed Bartels MD, Kristoffersen K, Slotsbjerg T, Rohde SM, Lundgren B, Westh H. Environmental meticillin-resistant Staphylococcus aureus (MRSA) disinfection using dry-mist-generated hydrogen peroxide. J Hosp Infect. 2008;70(1):35–41.CrossRefPubMed
11.
go back to reference Otter JA, Cummins M, Ahmad F, van Tonder C, Drabu YJ. Assessing the biological efficacy and rate of recontamination following hydrogen peroxide vapour decontamination. J Hospit Infect. 2007;67(2):182–8.CrossRef Otter JA, Cummins M, Ahmad F, van Tonder C, Drabu YJ. Assessing the biological efficacy and rate of recontamination following hydrogen peroxide vapour decontamination. J Hospit Infect. 2007;67(2):182–8.CrossRef
12.
go back to reference Hardy KJ, Gossain S, Henderson N, Drugan C, Oppenheim BA, Gao F, Hawkey PM. Rapid recontamination with MRSA of the environment of an intensive care unit after decontamination with hydrogen peroxide vapour. J Hospit Infect. 2007;66(4):360–8.CrossRef Hardy KJ, Gossain S, Henderson N, Drugan C, Oppenheim BA, Gao F, Hawkey PM. Rapid recontamination with MRSA of the environment of an intensive care unit after decontamination with hydrogen peroxide vapour. J Hospit Infect. 2007;66(4):360–8.CrossRef
13.
go back to reference French GL, Otter JA, Shannon KP, Adams NM, Watling D, Parks MJ. Tackling contamination of the hospital environment by methicillin-resistant Staphylococcus aureus (MRSA): a comparison between conventional terminal cleaning and hydrogen peroxide vapour decontamination. J Hospit Infect. 2004;57(1):31–7.CrossRef French GL, Otter JA, Shannon KP, Adams NM, Watling D, Parks MJ. Tackling contamination of the hospital environment by methicillin-resistant Staphylococcus aureus (MRSA): a comparison between conventional terminal cleaning and hydrogen peroxide vapour decontamination. J Hospit Infect. 2004;57(1):31–7.CrossRef
14.
go back to reference Shapey S, Machin K, Levi K, Boswell TC. Activity of a dry mist hydrogen peroxide system against environmental Clostridium difficile contamination in elderly care wards. J Hospit Infect. 2008;70(2):136–41.CrossRef Shapey S, Machin K, Levi K, Boswell TC. Activity of a dry mist hydrogen peroxide system against environmental Clostridium difficile contamination in elderly care wards. J Hospit Infect. 2008;70(2):136–41.CrossRef
16.
17.
go back to reference Noyce JO, Michels H, Keevil CW. Potential use of copper surfaces to reduce survival of epidemic meticillin-resistant Staphylococcus aureus in the healthcare environment. J Hospit Infect. 2006;63(3):289–97.CrossRef Noyce JO, Michels H, Keevil CW. Potential use of copper surfaces to reduce survival of epidemic meticillin-resistant Staphylococcus aureus in the healthcare environment. J Hospit Infect. 2006;63(3):289–97.CrossRef
18.
go back to reference Codita I, Caplan DM, Dragulescu EC, Lixandru BE, Coldea IL, Dragomirescu CC, Surdu-Bob C, Badulescu M. Antimicrobial activity of copper and silver nanofilms on nosocomial bacterial species. Roum Arch Microbiol Immunol. 2010;69(4):204–12.PubMed Codita I, Caplan DM, Dragulescu EC, Lixandru BE, Coldea IL, Dragomirescu CC, Surdu-Bob C, Badulescu M. Antimicrobial activity of copper and silver nanofilms on nosocomial bacterial species. Roum Arch Microbiol Immunol. 2010;69(4):204–12.PubMed
19.
go back to reference Karpanen TJ, Casey AL, Lambert PA, Cookson BD, Nightingale P, Miruszenko L, Elliott TS. The antimicrobial efficacy of copper alloy furnishing in the clinical environment: a crossover study. Infect Control Hosp Epidemiol. 2012;33(1):3–9.CrossRefPubMed Karpanen TJ, Casey AL, Lambert PA, Cookson BD, Nightingale P, Miruszenko L, Elliott TS. The antimicrobial efficacy of copper alloy furnishing in the clinical environment: a crossover study. Infect Control Hosp Epidemiol. 2012;33(1):3–9.CrossRefPubMed
20.
go back to reference Nakano R, Hara M, Ishiguro H, Yao Y, Ochiai T, Nakata K, Murakami T, Kajioka J, Sunada K, Hashimoto K, et al. Broad Spectrum Microbicidal activity of Photocatalysis by TiO2. Catalysts. 2013;3(1):310.CrossRef Nakano R, Hara M, Ishiguro H, Yao Y, Ochiai T, Nakata K, Murakami T, Kajioka J, Sunada K, Hashimoto K, et al. Broad Spectrum Microbicidal activity of Photocatalysis by TiO2. Catalysts. 2013;3(1):310.CrossRef
21.
go back to reference MAMLd J, Neto JTS, Timò G, Paiva PRP, Dantas MSS, Ferreira AM. Superhydrophilic self-cleaning surfaces based on TiO2 and TiO2/SiO2 composite films for photovoltaic module cover glass. Appl Adhes Sci. 2015;3(1):5.CrossRef MAMLd J, Neto JTS, Timò G, Paiva PRP, Dantas MSS, Ferreira AM. Superhydrophilic self-cleaning surfaces based on TiO2 and TiO2/SiO2 composite films for photovoltaic module cover glass. Appl Adhes Sci. 2015;3(1):5.CrossRef
22.
go back to reference Warheit DB. How to measure hazards/risks following exposures to nanoscale or pigment-grade titanium dioxide particles. Toxicol Lett. 2013;220(2):193–204.CrossRefPubMed Warheit DB. How to measure hazards/risks following exposures to nanoscale or pigment-grade titanium dioxide particles. Toxicol Lett. 2013;220(2):193–204.CrossRefPubMed
23.
go back to reference Ramsden J. Photocatalytic antimicrobial coatings. Nanotechnol Percept. 2015;11:146–68.CrossRef Ramsden J. Photocatalytic antimicrobial coatings. Nanotechnol Percept. 2015;11:146–68.CrossRef
24.
25.
go back to reference Chow WL, Tin AS, Lim WW, Lim J, Kurup A, Ling ML, Tan AL, Ong BC. Efficacy of titanium dioxide compounds in preventing environmental contamination by meticillin resistant Staphylococcus aureus (MRSA). Int J Infect Control. 2013;9(3):1-8. Chow WL, Tin AS, Lim WW, Lim J, Kurup A, Ling ML, Tan AL, Ong BC. Efficacy of titanium dioxide compounds in preventing environmental contamination by meticillin resistant Staphylococcus aureus (MRSA). Int J Infect Control. 2013;9(3):1-8.
26.
go back to reference Petti S, Messano G. Nano-TiO2-based photocatalytic disinfection of environmental surfaces contaminated by meticillin-resistant Staphylococcus aureus. J Hosp Infect. 2016;93(1):78–82.CrossRefPubMed Petti S, Messano G. Nano-TiO2-based photocatalytic disinfection of environmental surfaces contaminated by meticillin-resistant Staphylococcus aureus. J Hosp Infect. 2016;93(1):78–82.CrossRefPubMed
27.
go back to reference de Jong B, Meeder A, Koekkoek K, Schouten M, Westers P, van Zanten A. Pre–post evaluation of effects of a titanium dioxide coating on environmental contamination of an intensive care unit: the TITANIC study. J Hosp Infect. 2018;99(3):256–62.CrossRefPubMed de Jong B, Meeder A, Koekkoek K, Schouten M, Westers P, van Zanten A. Pre–post evaluation of effects of a titanium dioxide coating on environmental contamination of an intensive care unit: the TITANIC study. J Hosp Infect. 2018;99(3):256–62.CrossRefPubMed
28.
go back to reference Sehulster L, Chinn RY. Guidelines for environmental infection control in health-care facilities. Recommendations of CDC and the healthcare infection control practices advisory committee (HICPAC). MMWR Recomm Rep. 2003;52(Rr-10):1–42.PubMed Sehulster L, Chinn RY. Guidelines for environmental infection control in health-care facilities. Recommendations of CDC and the healthcare infection control practices advisory committee (HICPAC). MMWR Recomm Rep. 2003;52(Rr-10):1–42.PubMed
29.
go back to reference Horan TC, Andrus M, Dudeck MA. CDC/NHSN surveillance definition of health care-associated infection and criteria for specific types of infections in the acute care setting. Am J Infect Control. 2008;36(5):309–32.CrossRefPubMed Horan TC, Andrus M, Dudeck MA. CDC/NHSN surveillance definition of health care-associated infection and criteria for specific types of infections in the acute care setting. Am J Infect Control. 2008;36(5):309–32.CrossRefPubMed
30.
go back to reference Cho SY, Chung DR. Infection prevention strategy in hospitals in the era of community-associated methicillin-resistant Staphylococcus aureus in the Asia-Pacific region: a review. Clin Infect Dis. 2017;64(suppl_2):S82–s90.CrossRefPubMed Cho SY, Chung DR. Infection prevention strategy in hospitals in the era of community-associated methicillin-resistant Staphylococcus aureus in the Asia-Pacific region: a review. Clin Infect Dis. 2017;64(suppl_2):S82–s90.CrossRefPubMed
31.
go back to reference Stiefel U, Cadnum JL, Eckstein BC, Guerrero DM, Tima MA, Donskey CJ. Contamination of hands with methicillin-resistant Staphylococcus aureus after contact with environmental surfaces and after contact with the skin of colonized patients. Infect Control Hosp Epidemiol. 2011;32(2):185–7.CrossRefPubMed Stiefel U, Cadnum JL, Eckstein BC, Guerrero DM, Tima MA, Donskey CJ. Contamination of hands with methicillin-resistant Staphylococcus aureus after contact with environmental surfaces and after contact with the skin of colonized patients. Infect Control Hosp Epidemiol. 2011;32(2):185–7.CrossRefPubMed
32.
go back to reference Wagenvoort JH, Penders RJ. Long-term in-vitro survival of an epidemic MRSA phage-group III-29 strain. The J Hospit Infect. 1997;35(4):322–5.CrossRef Wagenvoort JH, Penders RJ. Long-term in-vitro survival of an epidemic MRSA phage-group III-29 strain. The J Hospit Infect. 1997;35(4):322–5.CrossRef
33.
go back to reference Wagenvoort JH, Sluijsmans W, Penders RJ. Better environmental survival of outbreak vs. sporadic MRSA isolates. J Hospit Infect. 2000;45(3):231–4.CrossRef Wagenvoort JH, Sluijsmans W, Penders RJ. Better environmental survival of outbreak vs. sporadic MRSA isolates. J Hospit Infect. 2000;45(3):231–4.CrossRef
34.
go back to reference Yadav HM, Kolekar TV, Pawar SH, Kim J-S. Enhanced photocatalytic inactivation of bacteria on Fe-containing TiO 2 nanoparticles under fluorescent light. J Mater Sci Mater Med. 2016;27(3):57.CrossRefPubMed Yadav HM, Kolekar TV, Pawar SH, Kim J-S. Enhanced photocatalytic inactivation of bacteria on Fe-containing TiO 2 nanoparticles under fluorescent light. J Mater Sci Mater Med. 2016;27(3):57.CrossRefPubMed
35.
go back to reference Hassan MM, Dylla H, Mohammad LN, Rupnow T. Evaluation of the durability of titanium dioxide photocatalyst coating for concrete pavement. Constr Build Mater. 2010;24(8):1456–61.CrossRef Hassan MM, Dylla H, Mohammad LN, Rupnow T. Evaluation of the durability of titanium dioxide photocatalyst coating for concrete pavement. Constr Build Mater. 2010;24(8):1456–61.CrossRef
36.
go back to reference Pulliam JR. Lower infection rates after introduction of a photocatalytic surface coating. Am J Infect Control. 2015;43(2):180–1.CrossRefPubMed Pulliam JR. Lower infection rates after introduction of a photocatalytic surface coating. Am J Infect Control. 2015;43(2):180–1.CrossRefPubMed
37.
go back to reference El Haddad L, Ghantoji SS, Stibich M, Fleming JB, Segal C, Ware KM, Chemaly RF. Evaluation of a pulsed xenon ultraviolet disinfection system to decrease bacterial contamination in operating rooms. BMC Infect Dis. 2017;17. El Haddad L, Ghantoji SS, Stibich M, Fleming JB, Segal C, Ware KM, Chemaly RF. Evaluation of a pulsed xenon ultraviolet disinfection system to decrease bacterial contamination in operating rooms. BMC Infect Dis. 2017;17.
38.
go back to reference Schmidt MG, Attaway HH, Sharpe PA, John J Jr, Sepkowitz KA, Morgan A, Fairey SE, Singh S, Steed LL, Cantey JR, et al. Sustained reduction of microbial burden on common hospital surfaces through introduction of copper. J Clin Microbiol. 2012;50(7):2217–23.CrossRefPubMedPubMedCentral Schmidt MG, Attaway HH, Sharpe PA, John J Jr, Sepkowitz KA, Morgan A, Fairey SE, Singh S, Steed LL, Cantey JR, et al. Sustained reduction of microbial burden on common hospital surfaces through introduction of copper. J Clin Microbiol. 2012;50(7):2217–23.CrossRefPubMedPubMedCentral
39.
go back to reference Yadav HM. Antibacterial studies with metal doped TiO2 nanoparticles; 2014. Yadav HM. Antibacterial studies with metal doped TiO2 nanoparticles; 2014.
40.
go back to reference Sugawara E, Nikaido H: OmpA is the principal nonspecific slow porin of Acinetobacter baumannii. J Bacteriol 2012:JB. 00435–00412. Sugawara E, Nikaido H: OmpA is the principal nonspecific slow porin of Acinetobacter baumannii. J Bacteriol 2012:JB. 00435–00412.
41.
go back to reference Binas V, Venieri D, Kotzias D, Kiriakidis G. Modified TiO2 based photocatalysts for improved air and health quality. J Mater. 2017;3(1):3–16. Binas V, Venieri D, Kotzias D, Kiriakidis G. Modified TiO2 based photocatalysts for improved air and health quality. J Mater. 2017;3(1):3–16.
Metadata
Title
Environmental disinfection with photocatalyst as an adjunctive measure to control transmission of methicillin-resistant Staphylococcus aureus: a prospective cohort study in a high-incidence setting
Authors
Min Hyung Kim
Seong Gyu Lee
Ki Sook Kim
Yoon Ji Heo
Ji Eun Oh
Su Jin Jeong
Publication date
01-12-2018
Publisher
BioMed Central
Published in
BMC Infectious Diseases / Issue 1/2018
Electronic ISSN: 1471-2334
DOI
https://doi.org/10.1186/s12879-018-3555-1

Other articles of this Issue 1/2018