Skip to main content
Top
Published in: BMC Infectious Diseases 1/2017

Open Access 01-12-2017 | Research article

Exploring surface cleaning strategies in hospital to prevent contact transmission of methicillin-resistant Staphylococcus aureus

Authors: Hao Lei, Rachael M. Jones, Yuguo Li

Published in: BMC Infectious Diseases | Issue 1/2017

Login to get access

Abstract

Background

Cleaning of environmental surfaces in hospitals is important for the control of methicillin-resistant Staphylococcus aureus (MRSA) and other hospital-acquired infections transmitted by the contact route. Guidance regarding the best approaches for cleaning, however, is limited.

Methods

In this study, a mathematical model based on ordinary differential equations was constructed to study MRSA concentration dynamics on high-touch and low-touch surfaces, and on the hands and noses of two patients (in two hospitals rooms) and a health care worker in a hypothetical hospital environment. Two cleaning interventions – whole room cleaning and wipe cleaning of touched surfaces – were considered. The performance of the cleaning interventions was indicated by a reduction in MRSA on the nose of a susceptible patient, relative to no intervention.

Results

Whole room cleaning just before first patient care activities of the day was more effective than whole room cleaning at other times, but even with 100% efficiency, whole room cleaning only reduced the number of MRSA transmitted to the susceptible patient by 54%. Frequent wipe cleaning of touched surfaces was shown to be more effective that whole room cleaning because surfaces are rapidly re-contaminated with MRSA after cleaning. Wipe cleaning high-touch surfaces was more effective than wipe cleaning low-touch surfaces for the same frequency of cleaning. For low wipe cleaning frequency (≤3 times per hour), high-touch surfaces should be targeted, but for high wipe cleaning frequency (>3 times per hour), cleaning should target high- and low-touch surfaces in proportion to the surface touch frequency. This study reproduces the observations from a field study of room cleaning, which provides support for the validity of our findings.

Conclusions

Daily whole room cleaning, even with 100% cleaning efficiency, provides limited reduction in the number of MRSA transmitted to susceptible patients via the contact route; and should be supplemented with frequent targeted cleaning of high-touch surfaces, such as by a wipe or cloth containing disinfectant.
Appendix
Available only for authorised users
Literature
1.
go back to reference Tiemersma EW, Monnet DL, Bruinsma N, Skov R, Monen JC, Grundmann H. Staphylococcus aureus bacteremia. Eur Emerg Infect Dis. 2005;11(11):1798–9. Tiemersma EW, Monnet DL, Bruinsma N, Skov R, Monen JC, Grundmann H. Staphylococcus aureus bacteremia. Eur Emerg Infect Dis. 2005;11(11):1798–9.
2.
go back to reference Siegel JD, Rhinehart E, Jackson M, Chiarello L. Guideline for isolation precautions: preventing transmission of infectious agents in health care settings. Am J Infect Control. 2007;35(10):65–164. Siegel JD, Rhinehart E, Jackson M, Chiarello L. Guideline for isolation precautions: preventing transmission of infectious agents in health care settings. Am J Infect Control. 2007;35(10):65–164.
3.
go back to reference Wilson APR, Smyth D, Moore G, Singleton J, Jackson R, Gant V, Jeanes A, Shaw S, James E, Cooper B, Kafatos G, Cookson B, Singer M, Bellingan G. The impact of enhanced cleaning within the intensive care unit on contamination of the near-patient environment with hospital pathogens: a randomized crossover study in critical care units in two hospitals. Crit Care Med. 2011;39(4):651–8.PubMed Wilson APR, Smyth D, Moore G, Singleton J, Jackson R, Gant V, Jeanes A, Shaw S, James E, Cooper B, Kafatos G, Cookson B, Singer M, Bellingan G. The impact of enhanced cleaning within the intensive care unit on contamination of the near-patient environment with hospital pathogens: a randomized crossover study in critical care units in two hospitals. Crit Care Med. 2011;39(4):651–8.PubMed
4.
go back to reference Rampling A, Wiseman S, Davis L, Hyett AP, Walbridge AN, Payne GC, Cornaby AJ. Evidence that hospital hygiene is important in the control of methicillin-resistant Staphylococcus aureus. J Hosp Infect. 2001;49(2):109–16.PubMed Rampling A, Wiseman S, Davis L, Hyett AP, Walbridge AN, Payne GC, Cornaby AJ. Evidence that hospital hygiene is important in the control of methicillin-resistant Staphylococcus aureus. J Hosp Infect. 2001;49(2):109–16.PubMed
5.
go back to reference Dancer SJ, White LF, Lamb J, Girvan KE, Robertson C. Measuring the effect of enhanced cleaning in a UK hospital: a prospective cross-over study. BMC Med. 2009;7(1):28.PubMedPubMedCentral Dancer SJ, White LF, Lamb J, Girvan KE, Robertson C. Measuring the effect of enhanced cleaning in a UK hospital: a prospective cross-over study. BMC Med. 2009;7(1):28.PubMedPubMedCentral
6.
go back to reference Sehulster L, Chinn RY. Centers for Disease Control and Prevention (CDC), Healthcare Infection Control Practices Advisory Committee (HICPAC). Guidelines for environmental infection control in health-care facilities. Recommendations of CDC and the HICPAC. MMWR Recomm Rep. 2003;52(10):1–42.PubMed Sehulster L, Chinn RY. Centers for Disease Control and Prevention (CDC), Healthcare Infection Control Practices Advisory Committee (HICPAC). Guidelines for environmental infection control in health-care facilities. Recommendations of CDC and the HICPAC. MMWR Recomm Rep. 2003;52(10):1–42.PubMed
7.
go back to reference Kundrapu S, Sunkesula V, Jury LA, Sitzlar BM, Donskey CJ. Daily disinfection of high-touch surfaces in isolation rooms to reduce contamination of healthcare workers’ hands. Infect Control Hosp Epidemiol. 2012;33(10):1039–42.PubMed Kundrapu S, Sunkesula V, Jury LA, Sitzlar BM, Donskey CJ. Daily disinfection of high-touch surfaces in isolation rooms to reduce contamination of healthcare workers’ hands. Infect Control Hosp Epidemiol. 2012;33(10):1039–42.PubMed
8.
go back to reference Cosgrove SE, Qi Y, Kaye KS, Harbarth S, Karchmer AW, Carmeli Y. The impact of methicillin resistance in Staphylococcus aureus bacteremia on patient outcomes: mortality, length of stay, and hospital charges. Infect Control Hosp Epidemio. 2005;26(02):166–74. Cosgrove SE, Qi Y, Kaye KS, Harbarth S, Karchmer AW, Carmeli Y. The impact of methicillin resistance in Staphylococcus aureus bacteremia on patient outcomes: mortality, length of stay, and hospital charges. Infect Control Hosp Epidemio. 2005;26(02):166–74.
9.
go back to reference Wang JT, Hsu LY, Lauderdale TL, Fan WC, Wang FD. Comparison of outcomes among adult patients with nosocomial bacteremia caused by methicillin-susceptible and methicillin-resistant staphylococcus aureus: A retrospective cohort study. PLoS One. 2015;10(12):e0144710.PubMedPubMedCentral Wang JT, Hsu LY, Lauderdale TL, Fan WC, Wang FD. Comparison of outcomes among adult patients with nosocomial bacteremia caused by methicillin-susceptible and methicillin-resistant staphylococcus aureus: A retrospective cohort study. PLoS One. 2015;10(12):e0144710.PubMedPubMedCentral
10.
go back to reference Neuraz A, Guérin C, Payet C, Polazzi S, Aubrun F, Dailler F, Lehot JJ, Piriou V, Neidecker J, Rimmelé T, Schott AM, Duclos A. Patient mortality is associated with staff resources and workload in the ICU: a multicenter observational study. Crit Care Med. 2015;43(8):1587–94.PubMed Neuraz A, Guérin C, Payet C, Polazzi S, Aubrun F, Dailler F, Lehot JJ, Piriou V, Neidecker J, Rimmelé T, Schott AM, Duclos A. Patient mortality is associated with staff resources and workload in the ICU: a multicenter observational study. Crit Care Med. 2015;43(8):1587–94.PubMed
11.
go back to reference Han JH, Sullivan N, Leas BF, Pegues DA, Kaczmarek JL, Umscheid CA. Cleaning Hospital Room Surfaces to Prevent Health Care–Associated Infections: A Technical Brief. Ann Intern Med. 2015;163(8):598–607.PubMedPubMedCentral Han JH, Sullivan N, Leas BF, Pegues DA, Kaczmarek JL, Umscheid CA. Cleaning Hospital Room Surfaces to Prevent Health Care–Associated Infections: A Technical Brief. Ann Intern Med. 2015;163(8):598–607.PubMedPubMedCentral
12.
go back to reference Gold KM, Hitchins VM. Cleaning assessment of disinfectant cleaning wipes on an external surface of a medical device contaminated with artificial blood or Streptococcus pneumoniae. Am J Infect Control. 2013;41(10):901–7.PubMed Gold KM, Hitchins VM. Cleaning assessment of disinfectant cleaning wipes on an external surface of a medical device contaminated with artificial blood or Streptococcus pneumoniae. Am J Infect Control. 2013;41(10):901–7.PubMed
13.
go back to reference Ramm L, Siani H, Wesgate R, Maillard JY. Pathogen transfer and high variability in pathogen removal by detergent wipes. Am J Infect Control. 2015;43(7):724–8.PubMed Ramm L, Siani H, Wesgate R, Maillard JY. Pathogen transfer and high variability in pathogen removal by detergent wipes. Am J Infect Control. 2015;43(7):724–8.PubMed
14.
go back to reference Wiemken TL, Curran DR, Pacholski EB, Kelley RR, Abdelfattah RR, Carrico RM, Ramirez JA. The value of ready-to-use disinfectant wipes: compliance, employee time, and costs. Am J Infect Control. 2014;42(3):329–30.PubMed Wiemken TL, Curran DR, Pacholski EB, Kelley RR, Abdelfattah RR, Carrico RM, Ramirez JA. The value of ready-to-use disinfectant wipes: compliance, employee time, and costs. Am J Infect Control. 2014;42(3):329–30.PubMed
15.
go back to reference Bonten MJM, Bootsma MCJ. Nosocomial transmission: methicillin-resistant Staphylococcus aureus (MRSA). Modern Infectious Disease Epidemiology. New York: Springer; 2010. p. 395–407. Bonten MJM, Bootsma MCJ. Nosocomial transmission: methicillin-resistant Staphylococcus aureus (MRSA). Modern Infectious Disease Epidemiology. New York: Springer; 2010. p. 395–407.
16.
go back to reference Coen P. Models of hospital acquired infection. China: INTECH Open Access Publisher; 2012. Coen P. Models of hospital acquired infection. China: INTECH Open Access Publisher; 2012.
17.
go back to reference Grundmann H, Hellriegel B. Mathematical modelling: a tool for hospital infection control. Lancet Infect Dis. 2006;6:39–45.PubMed Grundmann H, Hellriegel B. Mathematical modelling: a tool for hospital infection control. Lancet Infect Dis. 2006;6:39–45.PubMed
18.
go back to reference Wang X, Xiao Y, Wang J, Lu X. A mathematical model of effects of environmental contamination and presence of volunteers on hospital infections in China. J Theor Biol. 2012;293:161–73.PubMed Wang X, Xiao Y, Wang J, Lu X. A mathematical model of effects of environmental contamination and presence of volunteers on hospital infections in China. J Theor Biol. 2012;293:161–73.PubMed
19.
go back to reference Huslage K, Rutala WA, Weber DJ. A quantitative approach to defining “high‐touch” surfaces in hospitals. Infect Control Hosp Epidemiol. 2010;31(8):850–3.PubMed Huslage K, Rutala WA, Weber DJ. A quantitative approach to defining “high‐touch” surfaces in hospitals. Infect Control Hosp Epidemiol. 2010;31(8):850–3.PubMed
20.
go back to reference Plipat N, Spicknall LH, Koopman JS, Eisenberg JNS. The dynamics of methicillin-resistant Staphylococcus aureus exposure in a hospital model and the potential for environmental intervention. BMC Infect Dis. 2013;13(1):595.PubMedPubMedCentral Plipat N, Spicknall LH, Koopman JS, Eisenberg JNS. The dynamics of methicillin-resistant Staphylococcus aureus exposure in a hospital model and the potential for environmental intervention. BMC Infect Dis. 2013;13(1):595.PubMedPubMedCentral
21.
go back to reference Gehanno JF, Louvel A, Nouvellon M, Caillard JF, Pestel-Caron M. Aerial dispersal of methicillin-resistant Staphylococcus aureus in hospital rooms by infected or colonized patients. J Hosp Infect. 2009;71:256–62.PubMed Gehanno JF, Louvel A, Nouvellon M, Caillard JF, Pestel-Caron M. Aerial dispersal of methicillin-resistant Staphylococcus aureus in hospital rooms by infected or colonized patients. J Hosp Infect. 2009;71:256–62.PubMed
22.
go back to reference Hambraeus A. Dispersal and transfer of Staphylococcus aureus in an isolation ward for burned patients. J Hyg Camb. 1973;71:787–97.PubMed Hambraeus A. Dispersal and transfer of Staphylococcus aureus in an isolation ward for burned patients. J Hyg Camb. 1973;71:787–97.PubMed
23.
go back to reference Walter CW, Kundsin RB, Shilkret MA, Day MM. The spread of staphylococci in the environment. Antibiot Annu. 1957;6:952–7. Walter CW, Kundsin RB, Shilkret MA, Day MM. The spread of staphylococci in the environment. Antibiot Annu. 1957;6:952–7.
25.
go back to reference Ninomura P, Rousseau C, Bartley J. Updated guidelines for design and construction of hospital and health care facilities. ASHRAE J. 2006;48(6):33–7. Ninomura P, Rousseau C, Bartley J. Updated guidelines for design and construction of hospital and health care facilities. ASHRAE J. 2006;48(6):33–7.
26.
go back to reference Drake B. Infection control in hospitals. ASHRAE J. 2006;48(6):12–7. Drake B. Infection control in hospitals. ASHRAE J. 2006;48(6):12–7.
27.
go back to reference Noble WC, Lidwell OM, Kingston D. The size distribution of airborne particles carrying micro-organisms. J Hyg. 1963;61:385–91.PubMed Noble WC, Lidwell OM, Kingston D. The size distribution of airborne particles carrying micro-organisms. J Hyg. 1963;61:385–91.PubMed
28.
go back to reference Thatcher TL, Lai ACK, Moreno-Jackson R, Sextro RG, Nazaroff WW. Effects of room furnishings and air speed on particle deposition rates indoors. Atmos Environ. 2002;36(11):1811–9. Thatcher TL, Lai ACK, Moreno-Jackson R, Sextro RG, Nazaroff WW. Effects of room furnishings and air speed on particle deposition rates indoors. Atmos Environ. 2002;36(11):1811–9.
29.
go back to reference Pessoa-Silva CL, Dharan S, Hugonnet S, Touveneau S, Posfay-Barbe K, Pfister R. Dynamics of bacterial hand contamination during routine neonatal care. Infect Control Hosp Epidemiol. 2004;25:192–7.PubMed Pessoa-Silva CL, Dharan S, Hugonnet S, Touveneau S, Posfay-Barbe K, Pfister R. Dynamics of bacterial hand contamination during routine neonatal care. Infect Control Hosp Epidemiol. 2004;25:192–7.PubMed
30.
go back to reference Cheng KL, Boost MV, Yee JY. Study on the effectiveness of disinfection with wipes against methicillin-resistant Staphylococcus aureus and implications for hospital hygiene. Am J Infect Control. 2011;39(7):577–80.PubMed Cheng KL, Boost MV, Yee JY. Study on the effectiveness of disinfection with wipes against methicillin-resistant Staphylococcus aureus and implications for hospital hygiene. Am J Infect Control. 2011;39(7):577–80.PubMed
31.
go back to reference Hayden MK, Bonten MJM, Blom DW, Lyle EA, van de Vijver DA, Weinstein RA. Reduction in acquisition of vancomycin-resistant enterococcus after enforcement of routine environmental cleaning measures. Clin Infect Dis. 2006;42(11):1552–60.PubMed Hayden MK, Bonten MJM, Blom DW, Lyle EA, van de Vijver DA, Weinstein RA. Reduction in acquisition of vancomycin-resistant enterococcus after enforcement of routine environmental cleaning measures. Clin Infect Dis. 2006;42(11):1552–60.PubMed
32.
go back to reference Carling PC, Parry MF, Rupp ME, Po JL, Dick B, Beheren SV. Improving cleaning of the environment surrounding the patients in 36 acute care hospitals. Infect Control Hosp Epidemiol. 2008;29:1035–41.PubMed Carling PC, Parry MF, Rupp ME, Po JL, Dick B, Beheren SV. Improving cleaning of the environment surrounding the patients in 36 acute care hospitals. Infect Control Hosp Epidemiol. 2008;29:1035–41.PubMed
33.
go back to reference Rosenthal VD, Guzman S, Safdar N. Reduction in nosocomial infection with improved hand hygiene in intensive care units of a tertiary care hospital in Argentina. Am J Infect Control. 2005;33(7):392–7.PubMed Rosenthal VD, Guzman S, Safdar N. Reduction in nosocomial infection with improved hand hygiene in intensive care units of a tertiary care hospital in Argentina. Am J Infect Control. 2005;33(7):392–7.PubMed
34.
go back to reference Pittet D. Compliance with hand disinfection and its impact on hospital-acquired infections. J Hosp Infect. 2001;48:40–6. Pittet D. Compliance with hand disinfection and its impact on hospital-acquired infections. J Hosp Infect. 2001;48:40–6.
35.
go back to reference Temime L, Opatowski L, Pannet Y, Brun-Buisson C, Boëlle PY, Guillemot D. Peripatetic health-care workers as potential superspreaders. Proc Natl Acad Sci U S A. 2009;106(43):18420–5.PubMedPubMedCentral Temime L, Opatowski L, Pannet Y, Brun-Buisson C, Boëlle PY, Guillemot D. Peripatetic health-care workers as potential superspreaders. Proc Natl Acad Sci U S A. 2009;106(43):18420–5.PubMedPubMedCentral
36.
go back to reference Rose JB, Haas CN. A risk assessment framework for the evaluation of skin infections and the potential impact of antibacterial soap washing. Am J Infect Control. 1999;27(6):26–33. Rose JB, Haas CN. A risk assessment framework for the evaluation of skin infections and the potential impact of antibacterial soap washing. Am J Infect Control. 1999;27(6):26–33.
37.
go back to reference Singh G, Marples RR, Kligman AM. Experimental Staphylococcus aureus infections in humans. J Invest Dermato. 1971;57(3):149–62. Singh G, Marples RR, Kligman AM. Experimental Staphylococcus aureus infections in humans. J Invest Dermato. 1971;57(3):149–62.
38.
go back to reference Haas CN, Rose JB, Gerba CP. Quantitative microbial risk assessment. John Wiley & Sons, 1999. Haas CN, Rose JB, Gerba CP. Quantitative microbial risk assessment. John Wiley & Sons, 1999.
39.
go back to reference Dara SI, Afessa B. Intensivist-to-bed ratio: association with outcomes in the medical ICU. Chest. 2005;128(2):567–72.PubMed Dara SI, Afessa B. Intensivist-to-bed ratio: association with outcomes in the medical ICU. Chest. 2005;128(2):567–72.PubMed
40.
go back to reference Pittet D, Allegranzi B, Sax H, Dharan S, Pessoa-Silva CL, Donaldson L, Boyce JM. Evidence-based model for hand transmission during patient care and the role of improved practices. Lancet Infect Dis. 2006;6(10):641–52.PubMed Pittet D, Allegranzi B, Sax H, Dharan S, Pessoa-Silva CL, Donaldson L, Boyce JM. Evidence-based model for hand transmission during patient care and the role of improved practices. Lancet Infect Dis. 2006;6(10):641–52.PubMed
41.
go back to reference Dancer SJ. The role of environmental cleaning in the control of hospital-acquired infection. J Hosp Infect. 2009;73:378–85.PubMed Dancer SJ. The role of environmental cleaning in the control of hospital-acquired infection. J Hosp Infect. 2009;73:378–85.PubMed
42.
go back to reference Rheinbaben F, Schunemann S, Gross T, Wolff H. Transmission of viruses via contact in a household setting: experiments using bacteriophage straight phiX174 as a mode virus. J Hosp Infect. 2000;46:61–6.PubMed Rheinbaben F, Schunemann S, Gross T, Wolff H. Transmission of viruses via contact in a household setting: experiments using bacteriophage straight phiX174 as a mode virus. J Hosp Infect. 2000;46:61–6.PubMed
43.
go back to reference Bogusz A, Stewart M, Hunter J, Yip B, Reid D, Robertson C, Dancer SJ. How quickly do hospital surfaces become contaminated after detergent cleaning? Healthc Infect. 2013;18(1):3–9. Bogusz A, Stewart M, Hunter J, Yip B, Reid D, Robertson C, Dancer SJ. How quickly do hospital surfaces become contaminated after detergent cleaning? Healthc Infect. 2013;18(1):3–9.
44.
go back to reference Hardy KJ, Gossain S, Henderson N, Drugan C, Oppenheim BA, Gao F, Hawkey PM. Rapid recontamination with MRSA of the environment of an intensive care unit after decontamination with hydrogen peroxide vapour. J Hosp Infect. 2007;66(4):360–8.PubMed Hardy KJ, Gossain S, Henderson N, Drugan C, Oppenheim BA, Gao F, Hawkey PM. Rapid recontamination with MRSA of the environment of an intensive care unit after decontamination with hydrogen peroxide vapour. J Hosp Infect. 2007;66(4):360–8.PubMed
45.
go back to reference Williams GJ, Denyer SP, Hosein IK, Hill DW, Maillard J. Limitations of the efficacy of surface disinfection in the healthcare setting. Infect Control Hosp Epidemiol. 2009;30(6):570–3.PubMed Williams GJ, Denyer SP, Hosein IK, Hill DW, Maillard J. Limitations of the efficacy of surface disinfection in the healthcare setting. Infect Control Hosp Epidemiol. 2009;30(6):570–3.PubMed
Metadata
Title
Exploring surface cleaning strategies in hospital to prevent contact transmission of methicillin-resistant Staphylococcus aureus
Authors
Hao Lei
Rachael M. Jones
Yuguo Li
Publication date
01-12-2017
Publisher
BioMed Central
Published in
BMC Infectious Diseases / Issue 1/2017
Electronic ISSN: 1471-2334
DOI
https://doi.org/10.1186/s12879-016-2120-z

Other articles of this Issue 1/2017

BMC Infectious Diseases 1/2017 Go to the issue