Skip to main content
Top
Published in: BMC Medical Research Methodology 1/2018

Open Access 01-12-2018 | Research article

Retinal vascular tortuosity assessment: inter-intra expert analysis and correlation with computational measurements

Authors: Lucía Ramos, Jorge Novo, José Rouco, Stephanie Romeo, María D. Álvarez, Marcos Ortega

Published in: BMC Medical Research Methodology | Issue 1/2018

Login to get access

Abstract

Background

The retinal vascular tortuosity can be a potential indicator of relevant vascular and non-vascular diseases. However, the lack of a precise and standard guide for the tortuosity evaluation hinders its use for diagnostic and treatment purposes. This work aims to advance in the standardization of the retinal vascular tortuosity as a clinical biomarker with diagnostic potential, allowing, thereby, the validation of objective computational measurements on the basis of the entire spectrum of the expert knowledge.

Methods

This paper describes a multi-expert validation process of the computational vascular tortuosity measurements of reference. A group of five experts, covering the different clinical profiles of an ophthalmological service, and a four-grade scale from non-tortuous to severe tortuosity as well as non-tortuous / tortuous and asymptomatic / symptomatic binary classifications are considered for the analysis of the the multi-expert validation procedure. The specialists rating process comprises two rounds involving all the experts and a joint round to establish consensual rates. The expert agreement is analyzed throughout the rating procedure and, then, the consensual rates are set as the reference to validate the prognostic performance of four computational tortuosity metrics of reference.

Results

The Kappa indexes for the intra-rater agreement analysis were obtained between 0.35 and 0.83 whereas for the inter-rater agreement in the asymptomatic / symptomatic classification were between 0.22 and 0.76. The Area Under the Curve (AUC) for each expert against the consensual rates were placed between 0.61 and 0.83 whereas the prognostic performance of the best objective tortuosity metric was 0.80.

Conclusions

There is a high inter and intra-rater variability, especially for the case of the four grade scale. The prognostic performance of the tortuosity measurements is close to the experts’ performance, especially for Grisan measurement. However, there is a gap between the automatic effectiveness and the expert perception given the lack of clinical criteria in the computational measurements.
Literature
3.
go back to reference Barreira N, Penedo MG, González S, Ramos L, Cancela B, González A. Automatic analysis of the microaneurysm turnover in a web-based framework for retinal analysis. Image Anal Model Ophthalmol. 2014;111–128. Barreira N, Penedo MG, González S, Ramos L, Cancela B, González A. Automatic analysis of the microaneurysm turnover in a web-based framework for retinal analysis. Image Anal Model Ophthalmol. 2014;111–128.
4.
go back to reference Sánchez L, Novo J, Fernandez A, Barja JM. Unified methodology for evaluating vessel tree tortuosity metrics in eye fundus images. In: Proceedings of the 26th IEEE International Symposium on Computer-Based Medical Systems, Porto, Portugal, June 20-22, 2013. Porto: IEE: 2013. p. 528–9. https://doi.org/10.1109/CBMS.2013.6627862. Sánchez L, Novo J, Fernandez A, Barja JM. Unified methodology for evaluating vessel tree tortuosity metrics in eye fundus images. In: Proceedings of the 26th IEEE International Symposium on Computer-Based Medical Systems, Porto, Portugal, June 20-22, 2013. Porto: IEE: 2013. p. 528–9. https://​doi.​org/​10.​1109/​CBMS.​2013.​6627862.
5.
go back to reference Sánchez L, Barreira N, Penedo MG, de Tuero GC. Computer aided diagnosis system for retinal analysis: Automatic assessment of the vascular tortuosity. In: Innovation in Medicine and Healthcare 2014, Proceedings of the Second KES International Conference on Innovation in Medicine and Healthcares, InMed 2014. San Sebastian: IOS Press: 2014. p. 55–64. https://doi.org/10.3233/978-1-61499-474-9-55. Sánchez L, Barreira N, Penedo MG, de Tuero GC. Computer aided diagnosis system for retinal analysis: Automatic assessment of the vascular tortuosity. In: Innovation in Medicine and Healthcare 2014, Proceedings of the Second KES International Conference on Innovation in Medicine and Healthcares, InMed 2014. San Sebastian: IOS Press: 2014. p. 55–64. https://​doi.​org/​10.​3233/​978-1-61499-474-9-55.
13.
go back to reference Onkaew D, Turior R, Uyyanonvara B, Akinori N, Sinthanayothin C. Automatic retinal vessel tortuosity measurement using curvature of improved chain code. In: International Conference on Electrical, Control and Computer Engineering 2011 (InECCE).2011. p. 183–6. https://doi.org/10.1109/INECCE.2011.5953872. Onkaew D, Turior R, Uyyanonvara B, Akinori N, Sinthanayothin C. Automatic retinal vessel tortuosity measurement using curvature of improved chain code. In: International Conference on Electrical, Control and Computer Engineering 2011 (InECCE).2011. p. 183–6. https://​doi.​org/​10.​1109/​INECCE.​2011.​5953872.
15.
go back to reference Barreira N, Ortega M, Rouco J, Penedo MG, Pose-Reino A, Mariño C. Semi-automatic procedure for the computation of the arteriovenous ratio in retinal images. J Comput Vision Biomech. 2010; 3(2):135–47. Barreira N, Ortega M, Rouco J, Penedo MG, Pose-Reino A, Mariño C. Semi-automatic procedure for the computation of the arteriovenous ratio in retinal images. J Comput Vision Biomech. 2010; 3(2):135–47.
16.
Metadata
Title
Retinal vascular tortuosity assessment: inter-intra expert analysis and correlation with computational measurements
Authors
Lucía Ramos
Jorge Novo
José Rouco
Stephanie Romeo
María D. Álvarez
Marcos Ortega
Publication date
01-12-2018
Publisher
BioMed Central
Published in
BMC Medical Research Methodology / Issue 1/2018
Electronic ISSN: 1471-2288
DOI
https://doi.org/10.1186/s12874-018-0598-3

Other articles of this Issue 1/2018

BMC Medical Research Methodology 1/2018 Go to the issue