Skip to main content
Top
Published in: Critical Care 1/2010

Open Access 01-02-2010 | Research

The use of a blood conservation device to reduce red blood cell transfusion requirements: a before and after study

Authors: Amartya Mukhopadhyay, Hwee S Yip, Dimple Prabhuswamy, Yiong H Chan, Jason Phua, Tow K Lim, Patricia Leong

Published in: Critical Care | Issue 1/2010

Login to get access

Abstract

Introduction

Anaemia and the associated need for packed red blood cell (PRBC) transfusions are common in patients admitted to the intensive care unit (ICU). Among many causes, blood losses from repeated diagnostic tests are contributory.

Methods

This is a before and after study in a medical ICU of a university hospital. We used a closed blood conservation device (Venous Arterial blood Management Protection, VAMP, Edwards Lifesciences, Irvine, CA, USA) to decrease PRBC transfusion requirements. We included all adult (≥18 years) patients admitted to the ICU with indwelling arterial catheters, who were expected to stay more than 24 hours and were not admitted for active gastrointestinal or any other bleeding. We collected data for six months without VAMP (control group) immediately followed by nine months (active group) with VAMP. A restrictive transfusion strategy in which clinicians were strongly discouraged from any routine transfusions when haemoglobin (Hb) levels were above 7.5 g/dL was adopted during both periods.

Results

Eighty (mean age 61.6 years, 49 male) and 170 patients (mean age 60.5 years, 101 male) were included in the control and active groups respectively. The groups were comparable for age, gender, Acute Physiology and Chronic Health Evaluation (APACHE) II score, need for renal replacement therapy, length of stay, and Hb levels on discharge and at transfusion. The control group had higher Hb levels on admission (12.4 ± 2.5 vs. 11.58 ± 2.8 gm/dL, P = 0.02). Use of a blood conservation device was significantly associated with decreased requirements for PRBC transfusion (control group 0.131 unit vs. active group 0.068 unit PRBC/patient/day, P = 0.02) on multiple linear regression analysis. The control group also had a greater decline in Hb levels (2.13 ± 2.32 vs. 1.44 ± 2.08 gm/dL, P = 0.02) at discharge.

Conclusions

The use of a blood conservation device is associated with 1) reduced PRBC transfusion requirements and 2) a smaller decrease in Hb levels in the ICU.
Appendix
Available only for authorised users
Literature
1.
go back to reference Corwin HL, Gettinger A, Pearl RG, Fink MP, Levy MM, Abraham E, MacIntyre NR, Shabot MM, Duh MS, Shapiro MJ: The CRIT Study: Anemia and blood transfusion in the critically ill--current clinical practice in the United States. Crit Care Med. 2004, 32: 39-52. 10.1097/01.CCM.0000104112.34142.79.CrossRefPubMed Corwin HL, Gettinger A, Pearl RG, Fink MP, Levy MM, Abraham E, MacIntyre NR, Shabot MM, Duh MS, Shapiro MJ: The CRIT Study: Anemia and blood transfusion in the critically ill--current clinical practice in the United States. Crit Care Med. 2004, 32: 39-52. 10.1097/01.CCM.0000104112.34142.79.CrossRefPubMed
2.
go back to reference Tinmouth AT, McIntyre LA, Fowler RA: Blood conservation strategies to reduce the need for red blood cell transfusion in critically ill patients. CMAJ. 2008, 178: 49-57.PubMedCentralCrossRefPubMed Tinmouth AT, McIntyre LA, Fowler RA: Blood conservation strategies to reduce the need for red blood cell transfusion in critically ill patients. CMAJ. 2008, 178: 49-57.PubMedCentralCrossRefPubMed
3.
go back to reference von Ahsen N, Muller C, Serke S, Frei U, Eckardt KU: Important role of nondiagnostic blood loss and blunted erythropoietic response in the anemia of medical intensive care patients. Crit Care Med. 1999, 27: 2630-2639. 10.1097/00003246-199912000-00005.CrossRefPubMed von Ahsen N, Muller C, Serke S, Frei U, Eckardt KU: Important role of nondiagnostic blood loss and blunted erythropoietic response in the anemia of medical intensive care patients. Crit Care Med. 1999, 27: 2630-2639. 10.1097/00003246-199912000-00005.CrossRefPubMed
4.
go back to reference Fowler RA, Berenson M: Blood conservation in the intensive care unit. Crit Care Med. 2003, 31: S715-S720. 10.1097/01.CCM.0000099350.50651.46.CrossRefPubMed Fowler RA, Berenson M: Blood conservation in the intensive care unit. Crit Care Med. 2003, 31: S715-S720. 10.1097/01.CCM.0000099350.50651.46.CrossRefPubMed
5.
go back to reference Vincent JL, Baron JF, Reinhart K, Gattinoni L, Thijs L, Webb A, Meier-Hellmann A, Nollet G, Peres-Bota D: Anemia and blood transfusion in critically ill patients. JAMA. 2002, 288: 1499-1507. 10.1001/jama.288.12.1499.CrossRefPubMed Vincent JL, Baron JF, Reinhart K, Gattinoni L, Thijs L, Webb A, Meier-Hellmann A, Nollet G, Peres-Bota D: Anemia and blood transfusion in critically ill patients. JAMA. 2002, 288: 1499-1507. 10.1001/jama.288.12.1499.CrossRefPubMed
6.
go back to reference Corwin HL, Parsonnet KC, Gettinger A: RBC Transfusion in the ICU. Chest. 1995, 108: 767-771. 10.1378/chest.108.3.767.CrossRefPubMed Corwin HL, Parsonnet KC, Gettinger A: RBC Transfusion in the ICU. Chest. 1995, 108: 767-771. 10.1378/chest.108.3.767.CrossRefPubMed
7.
go back to reference Smoller BR, Kruskall MS: Phlebotomy for diagnostic laboratory tests in adults. Pattern of use and effect on transfusion requirements. N Engl J Med. 1986, 314: 1233-1235.CrossRefPubMed Smoller BR, Kruskall MS: Phlebotomy for diagnostic laboratory tests in adults. Pattern of use and effect on transfusion requirements. N Engl J Med. 1986, 314: 1233-1235.CrossRefPubMed
8.
go back to reference Zimmerman JE, Seneff MG, Sun X, Wagner DP, Knaus WA: Evaluating laboratory usage in the intensive care unit: patient and institutional characteristics that influence frequency of blood sampling. Crit Care Med. 1997, 25: 737-748. 10.1097/00003246-199705000-00006.CrossRefPubMed Zimmerman JE, Seneff MG, Sun X, Wagner DP, Knaus WA: Evaluating laboratory usage in the intensive care unit: patient and institutional characteristics that influence frequency of blood sampling. Crit Care Med. 1997, 25: 737-748. 10.1097/00003246-199705000-00006.CrossRefPubMed
9.
go back to reference Hebert PC, Wells G, Blajchman MA, Marshall J, Martin C, Pagliarello G, Tweeddale M, Schweitzer I, Yetisir E, The Transfusion Requirements in Critical Care Investigators for the Canadian Critical Care Trials Group: A Multicenter, Randomized, Controlled Clinical Trial of Transfusion Requirements in Critical Care. N Engl J Med. 1999, 340: 409-417. 10.1056/NEJM199902113400601.CrossRefPubMed Hebert PC, Wells G, Blajchman MA, Marshall J, Martin C, Pagliarello G, Tweeddale M, Schweitzer I, Yetisir E, The Transfusion Requirements in Critical Care Investigators for the Canadian Critical Care Trials Group: A Multicenter, Randomized, Controlled Clinical Trial of Transfusion Requirements in Critical Care. N Engl J Med. 1999, 340: 409-417. 10.1056/NEJM199902113400601.CrossRefPubMed
10.
go back to reference Kleinman S, Chan P, Robillard P: Risks associated with transfusion of cellular blood components in Canada. Transfus Med Rev. 2003, 17: 120-162.CrossRefPubMed Kleinman S, Chan P, Robillard P: Risks associated with transfusion of cellular blood components in Canada. Transfus Med Rev. 2003, 17: 120-162.CrossRefPubMed
11.
go back to reference Shorr AF, Jackson WL, Kelly KM, Fu M, Kollef MH: Transfusion practice and blood stream infections in critically ill patients. Chest. 2005, 127: 1722-1728. 10.1378/chest.127.5.1722.CrossRefPubMed Shorr AF, Jackson WL, Kelly KM, Fu M, Kollef MH: Transfusion practice and blood stream infections in critically ill patients. Chest. 2005, 127: 1722-1728. 10.1378/chest.127.5.1722.CrossRefPubMed
12.
go back to reference Shorr AF, Duh MS, Kelly KM, Kollef MH: Red blood cell transfusion and ventilator-associated pneumonia: A potential link?. Crit Care Med. 2004, 32: 666-674. 10.1097/01.CCM.0000114810.30477.C3.CrossRefPubMed Shorr AF, Duh MS, Kelly KM, Kollef MH: Red blood cell transfusion and ventilator-associated pneumonia: A potential link?. Crit Care Med. 2004, 32: 666-674. 10.1097/01.CCM.0000114810.30477.C3.CrossRefPubMed
13.
go back to reference Gong MN, Thompson BT, Williams P, Pothier L, Boyce PD, Christiani DC: Clinical predictors of and mortality in acute respiratory distress syndrome: potential role of red cell transfusion. Crit Care Med. 2005, 33: 1191-1198. 10.1097/01.CCM.0000165566.82925.14.CrossRefPubMed Gong MN, Thompson BT, Williams P, Pothier L, Boyce PD, Christiani DC: Clinical predictors of and mortality in acute respiratory distress syndrome: potential role of red cell transfusion. Crit Care Med. 2005, 33: 1191-1198. 10.1097/01.CCM.0000165566.82925.14.CrossRefPubMed
14.
go back to reference Zilberberg MD, Carter C, Lefebvre P, Raut M, Vekeman F, Duh MS, Shorr AF: Red blood cell transfusions and the risk of acute respiratory distress syndrome among the critically ill: a cohort study. Crit Care. 2007, 11: R63-10.1186/cc5934.PubMedCentralCrossRefPubMed Zilberberg MD, Carter C, Lefebvre P, Raut M, Vekeman F, Duh MS, Shorr AF: Red blood cell transfusions and the risk of acute respiratory distress syndrome among the critically ill: a cohort study. Crit Care. 2007, 11: R63-10.1186/cc5934.PubMedCentralCrossRefPubMed
15.
go back to reference Gleason E, Grossman S, Campbell C: Minimizing diagnostic blood loss in critically ill patients. Am J Crit Care. 1992, 1: 85-90.PubMed Gleason E, Grossman S, Campbell C: Minimizing diagnostic blood loss in critically ill patients. Am J Crit Care. 1992, 1: 85-90.PubMed
16.
go back to reference Silver MJ, Jubran H, Stein S, McSweeney T, Jubran F: Evaluation of a new blood-conserving arterial line system for patients in intensive care units. Crit Care Med. 1993, 21: 507-511. 10.1097/00003246-199304000-00008.CrossRefPubMed Silver MJ, Jubran H, Stein S, McSweeney T, Jubran F: Evaluation of a new blood-conserving arterial line system for patients in intensive care units. Crit Care Med. 1993, 21: 507-511. 10.1097/00003246-199304000-00008.CrossRefPubMed
17.
go back to reference MacIsaac CM, Presneill JJ, Boyce CA, Byron KL, Cade JF: The influence of a blood conserving device on anaemia in intensive care patients. Anaesth Intensive Care. 2003, 31: 653-657.PubMed MacIsaac CM, Presneill JJ, Boyce CA, Byron KL, Cade JF: The influence of a blood conserving device on anaemia in intensive care patients. Anaesth Intensive Care. 2003, 31: 653-657.PubMed
18.
go back to reference Silver MJ, Li YH, Gragg LA, Jubran F, Stoller JK: Reduction of blood loss from diagnostic sampling in critically ill patients using a blood-conserving arterial line system. Chest. 1993, 104: 1711-1715. 10.1378/chest.104.6.1711.CrossRefPubMed Silver MJ, Li YH, Gragg LA, Jubran F, Stoller JK: Reduction of blood loss from diagnostic sampling in critically ill patients using a blood-conserving arterial line system. Chest. 1993, 104: 1711-1715. 10.1378/chest.104.6.1711.CrossRefPubMed
19.
go back to reference Peruzzi WT, Parker MA, Lichtenthal PR, Cochran-Zull C, Toth B, Blake M: A clinical evaluation of a blood conservation device in medical intensive care unit patients. Crit Care Med. 1993, 21: 501-506. 10.1097/00003246-199304000-00007.CrossRefPubMed Peruzzi WT, Parker MA, Lichtenthal PR, Cochran-Zull C, Toth B, Blake M: A clinical evaluation of a blood conservation device in medical intensive care unit patients. Crit Care Med. 1993, 21: 501-506. 10.1097/00003246-199304000-00007.CrossRefPubMed
20.
go back to reference Corwin HL: Blood conservation in the critically ill patient. Anesthesiol Clin North America. 2005, 23: 363-72. 10.1016/j.atc.2005.02.003. viiiCrossRefPubMed Corwin HL: Blood conservation in the critically ill patient. Anesthesiol Clin North America. 2005, 23: 363-72. 10.1016/j.atc.2005.02.003. viiiCrossRefPubMed
21.
go back to reference Peruzzi WT, Noskin GA, Moen SG, Yungbluth M, Lichtenthal P, Shapiro BA: Microbial contamination of blood conservation devices during routine use in the critical care setting: results of a prospective, randomized trial. Crit Care Med. 1996, 24: 1157-1162. 10.1097/00003246-199607000-00015.CrossRefPubMed Peruzzi WT, Noskin GA, Moen SG, Yungbluth M, Lichtenthal P, Shapiro BA: Microbial contamination of blood conservation devices during routine use in the critical care setting: results of a prospective, randomized trial. Crit Care Med. 1996, 24: 1157-1162. 10.1097/00003246-199607000-00015.CrossRefPubMed
22.
go back to reference O'Hare D, Chilvers RJ: Arterial blood sampling practices in intensive care units in England and Wales. Anaesthesia. 2001, 56: 568-571. 10.1046/j.1365-2044.2001.01913.x.CrossRefPubMed O'Hare D, Chilvers RJ: Arterial blood sampling practices in intensive care units in England and Wales. Anaesthesia. 2001, 56: 568-571. 10.1046/j.1365-2044.2001.01913.x.CrossRefPubMed
Metadata
Title
The use of a blood conservation device to reduce red blood cell transfusion requirements: a before and after study
Authors
Amartya Mukhopadhyay
Hwee S Yip
Dimple Prabhuswamy
Yiong H Chan
Jason Phua
Tow K Lim
Patricia Leong
Publication date
01-02-2010
Publisher
BioMed Central
Published in
Critical Care / Issue 1/2010
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc8859

Other articles of this Issue 1/2010

Critical Care 1/2010 Go to the issue