Skip to main content
Top
Published in: EJNMMI Research 1/2013

Open Access 01-12-2013 | Original research

Optimization of [11C]methionine PET study: appropriate scan timing and effect of plasma amino acid concentrations on the SUV

Authors: Kayako Isohashi, Eku Shimosegawa, Hiroki Kato, Yasukazu Kanai, Sadahiro Naka, Koichi Fujino, Hiroshi Watabe, Jun Hatazawa

Published in: EJNMMI Research | Issue 1/2013

Login to get access

Abstract

Background

[11C]methionine (MET) has been used to monitor amino acid metabolism in tumors, the pancreas, liver, and myocardium. The aim of the present study was to standardize [11C]MET positron emission tomography (PET) by optimizing the timing of initiation of the scan and applying correction to the plasma concentrations of neutral amino acids (NAAs), where necessary.

Methods

Sequential whole-body MET PET/computed tomography (CT) was performed in 11 normal adults after they had fasted for at least 4 h. After whole-body CT for attenuation correction and intravenous bolus injection of MET, the subjects were scanned from the parietal to the groin. The scanning was repeated six to seven times. Decay of radioactivity during the PET scan was corrected to the time of initiation of the first scan. The standardized uptake values (SUVs) were evaluated in various organs by setting regions of interest on the tomographic images. Plasma concentrations of NAAs were examined in relation to the SUV values.

Results

The SUVs in the pancreas reached their plateau from 6.5 to 11 min after the MET injection, and in the brain, lung, and myocardium, they reached their plateau from 19.6 to 24.1 min. The MET uptake in the spleen and kidney peaked early after the injection and steadily decreased thereafter. The SUVs in the liver and stomach wall rapidly increased during the first 0 to 4.5 min and gradually elevated thereafter during the scan period. Urinary radioactivity in the bladder reached its plateau from 26.1 to 30.6 min after the MET injection. There were no correlations between the plasma concentrations of NAAs and the maximal SUV in any organs.

Conclusions

The present study revealed the times taken to reach the plateau of MET uptake in various important organs, and little effects of the plasma neutral amino acid concentrations on the SUVs in PET studies conducted after the patients had fasted for at least 4 h. In the MET PET study, 4 h fasting period before MET administration and the scan initiation 20 min after MET administration provide the SUV values independent of scan initiation time and the plasma neutral amino acid concentrations.
Appendix
Available only for authorised users
Literature
1.
go back to reference Shiiba M, Ishihara K, Kimura G, Kuwako T, Yoshihara H, Sato H, Kondo Y, Tsuchiya S, Kumita S: Evaluation of primary prostate cancer using 11 C-methionine-PET/CT and 18 F-FDG-PET/CT. Ann Nucl Med 2012, 26: 138–145. 10.1007/s12149-011-0551-6CrossRef Shiiba M, Ishihara K, Kimura G, Kuwako T, Yoshihara H, Sato H, Kondo Y, Tsuchiya S, Kumita S: Evaluation of primary prostate cancer using 11 C-methionine-PET/CT and 18 F-FDG-PET/CT. Ann Nucl Med 2012, 26: 138–145. 10.1007/s12149-011-0551-6CrossRef
2.
go back to reference Nariai T, Tanaka Y, Wakimoto H, Aoyagi M, Tamaki M, Ishiwata K, Senda M, Ishii K, Hirakawa K, Ohno K: Usefulness of L -[methyl- 11 C] methionine-positron emission tomography as a biological monitoring tool in the treatment of glioma. J Neurosurg 2005, 103: 498–507. 10.3171/jns.2005.103.3.0498CrossRef Nariai T, Tanaka Y, Wakimoto H, Aoyagi M, Tamaki M, Ishiwata K, Senda M, Ishii K, Hirakawa K, Ohno K: Usefulness of L -[methyl- 11 C] methionine-positron emission tomography as a biological monitoring tool in the treatment of glioma. J Neurosurg 2005, 103: 498–507. 10.3171/jns.2005.103.3.0498CrossRef
3.
go back to reference Shinozaki N, Uchino Y, Yoshikawa K, Matsutani T, Hasegawa A, Saeki N, Iwadate Y: Discrimination between low-grade oligodendrogliomas and diffuse astrocytoma with the aid of 11C-methionine positron emission tomography. J Neurosurg 2011, 114: 1640–1647. 10.3171/2010.11.JNS10553CrossRef Shinozaki N, Uchino Y, Yoshikawa K, Matsutani T, Hasegawa A, Saeki N, Iwadate Y: Discrimination between low-grade oligodendrogliomas and diffuse astrocytoma with the aid of 11C-methionine positron emission tomography. J Neurosurg 2011, 114: 1640–1647. 10.3171/2010.11.JNS10553CrossRef
4.
go back to reference Mahasittiwat P, Mizoe JE, Hasegawa A, Ishikawa H, Yoshikawa K, Mizuno H, Yanagi T, Takagi R, Pattaranutaporn P, Tsujii H: l-[Methyl-(11)C] methionine positron emission tomography for target delineation in malignant gliomas: impact on results of carbon ion radiotherapy. Int J Radiat Oncol Biol Phys 2008, 70: 515–522. 10.1016/j.ijrobp.2007.06.071CrossRef Mahasittiwat P, Mizoe JE, Hasegawa A, Ishikawa H, Yoshikawa K, Mizuno H, Yanagi T, Takagi R, Pattaranutaporn P, Tsujii H: l-[Methyl-(11)C] methionine positron emission tomography for target delineation in malignant gliomas: impact on results of carbon ion radiotherapy. Int J Radiat Oncol Biol Phys 2008, 70: 515–522. 10.1016/j.ijrobp.2007.06.071CrossRef
5.
go back to reference Coope DJ, Cízek J, Eggers C, Vollmar S, Heiss WD, Herholz K: Evaluation of primary brain tumors using 11 C-methionine PET with reference to a normal methionine uptake map. J Nucl Med 2007, 48: 1971–1980. 10.2967/jnumed.107.043240CrossRef Coope DJ, Cízek J, Eggers C, Vollmar S, Heiss WD, Herholz K: Evaluation of primary brain tumors using 11 C-methionine PET with reference to a normal methionine uptake map. J Nucl Med 2007, 48: 1971–1980. 10.2967/jnumed.107.043240CrossRef
6.
go back to reference Hasebe M, Yoshikawa K, Ohashi S, Toubaru S, Kawaguchi K, Sato J, Mizoe J, Tsujii H: A study on the prognostic evaluation of carbon ion radiotherapy for head and neck adenocarcinoma with C-11 methionine PET. Mol Imaging Biol 2010, 12: 554–562. 10.1007/s11307-010-0318-9CrossRef Hasebe M, Yoshikawa K, Ohashi S, Toubaru S, Kawaguchi K, Sato J, Mizoe J, Tsujii H: A study on the prognostic evaluation of carbon ion radiotherapy for head and neck adenocarcinoma with C-11 methionine PET. Mol Imaging Biol 2010, 12: 554–562. 10.1007/s11307-010-0318-9CrossRef
7.
go back to reference Jang HW, Choi JY, Lee JI, Kim HK, Shin HW, Shin JH, Kim SW, Chung JH: Localization of medullary thyroid carcinoma after surgery using (11)C-methionine PET/CT: comparison with (18)F-FDG PET/CT. Endocr J 2010, 57: 1045–1054. 10.1507/endocrj.K10E-258CrossRef Jang HW, Choi JY, Lee JI, Kim HK, Shin HW, Shin JH, Kim SW, Chung JH: Localization of medullary thyroid carcinoma after surgery using (11)C-methionine PET/CT: comparison with (18)F-FDG PET/CT. Endocr J 2010, 57: 1045–1054. 10.1507/endocrj.K10E-258CrossRef
8.
go back to reference Herrmann K, Takei T, Kanegae K, Shiga T, Buck AK, Altomonte J, Schwaiger M, Schuster T, Nishijima K, Kuge Y, Tamaki N: Clinical value and limitations of [ 11 C]-methionine PET for detection and localization of suspected parathyroid adenomas. Mol Imaging Biol 2009, 11: 356–363. 10.1007/s11307-009-0205-4CrossRef Herrmann K, Takei T, Kanegae K, Shiga T, Buck AK, Altomonte J, Schwaiger M, Schuster T, Nishijima K, Kuge Y, Tamaki N: Clinical value and limitations of [ 11 C]-methionine PET for detection and localization of suspected parathyroid adenomas. Mol Imaging Biol 2009, 11: 356–363. 10.1007/s11307-009-0205-4CrossRef
9.
go back to reference Kanegae K, Nakano I, Kimura K, Kaji H, Kuge Y, Shiga T, Zhao S, Okamoto S, Tamaki N: Comparison of MET-PET and FDG-PET for differentiation between benign lesions and lung cancer in pneumoconiosis. Ann Nucl Med 2007, 21: 331–337. 10.1007/s12149-007-0035-xCrossRef Kanegae K, Nakano I, Kimura K, Kaji H, Kuge Y, Shiga T, Zhao S, Okamoto S, Tamaki N: Comparison of MET-PET and FDG-PET for differentiation between benign lesions and lung cancer in pneumoconiosis. Ann Nucl Med 2007, 21: 331–337. 10.1007/s12149-007-0035-xCrossRef
10.
go back to reference Hsieh HJ, Lin SH, Lin KH, Lee CY, Chang CP, Wang SJ: The feasibility of 11 C-methionine-PET in diagnosis of solitary lung nodules/masses when compared with 18 F-FDG-PET. Ann Nucl Med 2008, 22: 533–538. 10.1007/s12149-007-0142-8CrossRef Hsieh HJ, Lin SH, Lin KH, Lee CY, Chang CP, Wang SJ: The feasibility of 11 C-methionine-PET in diagnosis of solitary lung nodules/masses when compared with 18 F-FDG-PET. Ann Nucl Med 2008, 22: 533–538. 10.1007/s12149-007-0142-8CrossRef
11.
go back to reference Lindholm P, Lapela M, Någren K, Lehikoinen P, Minn H, Jyrkkiö S: Preliminary study of carbon-11 methionine PET in the evaluation of early response to therapy in advanced breast cancer. Nucl Med Commun 2009, 30: 30–36. 10.1097/MNM.0b013e328313b7bcCrossRef Lindholm P, Lapela M, Någren K, Lehikoinen P, Minn H, Jyrkkiö S: Preliminary study of carbon-11 methionine PET in the evaluation of early response to therapy in advanced breast cancer. Nucl Med Commun 2009, 30: 30–36. 10.1097/MNM.0b013e328313b7bcCrossRef
12.
go back to reference Sasaki M, Kuwabara Y, Ichiya Y, Akashi Y, Yoshida T, Nakagawa M, Murayama S, Masuda K: Differential diagnosis of thymic tumors using a combination of 11 C-methionine PET and FDG PET. J Nucl Med 1999, 40: 1595–1601. Sasaki M, Kuwabara Y, Ichiya Y, Akashi Y, Yoshida T, Nakagawa M, Murayama S, Masuda K: Differential diagnosis of thymic tumors using a combination of 11 C-methionine PET and FDG PET. J Nucl Med 1999, 40: 1595–1601.
13.
go back to reference Koizumi M, Saga T, Yoshikawa K, Suzuki K, Yamada S, Hasebe M, Ohashi S, Abd-Elrazek S, Ishikawa H, Sagou K, Tamura K, Hara R, Kato H, Yasuda S, Yanagi T, Tsujii H: 11 C-methionine-PET for evaluation of carbon ion radiotherapy in patients with pelvic recurrence of rectal cancer. Mol Imaging Biol 2008, 10: 374–380. 10.1007/s11307-008-0156-1CrossRef Koizumi M, Saga T, Yoshikawa K, Suzuki K, Yamada S, Hasebe M, Ohashi S, Abd-Elrazek S, Ishikawa H, Sagou K, Tamura K, Hara R, Kato H, Yasuda S, Yanagi T, Tsujii H: 11 C-methionine-PET for evaluation of carbon ion radiotherapy in patients with pelvic recurrence of rectal cancer. Mol Imaging Biol 2008, 10: 374–380. 10.1007/s11307-008-0156-1CrossRef
14.
go back to reference Macapinlac HA, Humm JL, Akhurst T, Osman I, Pentlow K, Shangde C, Yeung HW, Squire O, Finn RD, Scher HI, Larson SM: Differential metabolism and pharmacokinetics of L-[1-(11)C]-methionine and 2-[(18)F] fluoro-2-deoxy-D-glucose (FDG) in androgen independent prostate cancer. Clin Positron Imaging 1999, 2: 173–181. 10.1016/S1095-0397(99)00015-1CrossRef Macapinlac HA, Humm JL, Akhurst T, Osman I, Pentlow K, Shangde C, Yeung HW, Squire O, Finn RD, Scher HI, Larson SM: Differential metabolism and pharmacokinetics of L-[1-(11)C]-methionine and 2-[(18)F] fluoro-2-deoxy-D-glucose (FDG) in androgen independent prostate cancer. Clin Positron Imaging 1999, 2: 173–181. 10.1016/S1095-0397(99)00015-1CrossRef
15.
go back to reference Wieder H, Ott K, Zimmermann F, Nekarda H, Stollfuss J, Watzlowik P, Siewert JR, Fink U, Becker K, Schwaiger M, Weber WA: PET imaging with [ 11 C]methyl- L -methionine for therapy monitoring in patients with rectal cancer. Eur J Nucl Med Mol Imaging 2002, 29: 789–796. 10.1007/s00259-002-0779-4CrossRef Wieder H, Ott K, Zimmermann F, Nekarda H, Stollfuss J, Watzlowik P, Siewert JR, Fink U, Becker K, Schwaiger M, Weber WA: PET imaging with [ 11 C]methyl- L -methionine for therapy monitoring in patients with rectal cancer. Eur J Nucl Med Mol Imaging 2002, 29: 789–796. 10.1007/s00259-002-0779-4CrossRef
16.
go back to reference Lapela M, Leskinen-Kallio S, Varpula M, Grénman S, Salmi T, Alanen K, Någren K, Lehikoinen P, Ruotsalainen U, Teräs M, Joensuu H: Metabolic imaging of ovarian tumors with carbon-11-methionine: a PET study. J Nucl Med 1995, 36: 2196–2200. Lapela M, Leskinen-Kallio S, Varpula M, Grénman S, Salmi T, Alanen K, Någren K, Lehikoinen P, Ruotsalainen U, Teräs M, Joensuu H: Metabolic imaging of ovarian tumors with carbon-11-methionine: a PET study. J Nucl Med 1995, 36: 2196–2200.
17.
go back to reference Lapela M, Leskinen-Kallio S, Varpula M, Grenman S, Alanen K, Någren K, Lehikoinen P, Ruotsalainen U, Teräs M, Joensuu H: Imaging of uterine carcinoma by carbon-11-methionine and PET. J Nucl Med 1994, 35: 1618–1623. Lapela M, Leskinen-Kallio S, Varpula M, Grenman S, Alanen K, Någren K, Lehikoinen P, Ruotsalainen U, Teräs M, Joensuu H: Imaging of uterine carcinoma by carbon-11-methionine and PET. J Nucl Med 1994, 35: 1618–1623.
18.
go back to reference Dankerl A, Liebisch P, Glatting G, Friesen C, Blumstein NM, Kocot D, Wendl C, Bunjes D, Reske SN: Multiple myeloma: molecular imaging with 11C-methionine PET/CT–initial experience. Radiology 2007, 242: 498–508.CrossRef Dankerl A, Liebisch P, Glatting G, Friesen C, Blumstein NM, Kocot D, Wendl C, Bunjes D, Reske SN: Multiple myeloma: molecular imaging with 11C-methionine PET/CT–initial experience. Radiology 2007, 242: 498–508.CrossRef
19.
go back to reference Syrota A, Duquesnoy N, Paraf A, Kellershohn C: The role of positron emission tomography in the detection of pancreatic disease. Radiology 1982, 143: 249–253.CrossRef Syrota A, Duquesnoy N, Paraf A, Kellershohn C: The role of positron emission tomography in the detection of pancreatic disease. Radiology 1982, 143: 249–253.CrossRef
20.
go back to reference Kubota K, Ito M, Fukuda H, Abe Y, Ito K, Fujiwara T, Yoshioka S, Hatazawa J, Matsuzawa T, Iwata R, Watanuki S, Ishiwata K, Ido T: Cancer diagnosis with positron computed tomography and carbon-11-labelled L-methionine. Lancet 1983, 2: 1192.CrossRef Kubota K, Ito M, Fukuda H, Abe Y, Ito K, Fujiwara T, Yoshioka S, Hatazawa J, Matsuzawa T, Iwata R, Watanuki S, Ishiwata K, Ido T: Cancer diagnosis with positron computed tomography and carbon-11-labelled L-methionine. Lancet 1983, 2: 1192.CrossRef
21.
go back to reference Okita Y, Kinoshita M, Goto T, Kagawa N, Kishima H, Shimosegawa E, Hatazawa J, Hashimoto N, Yoshimine T: (11)C-methionine uptake correlates with tumor cell density rather than with microvessel density in glioma: a stereotactic image-histology comparison. NeuroImage 2010, 49: 2977–2982. 10.1016/j.neuroimage.2009.11.024CrossRef Okita Y, Kinoshita M, Goto T, Kagawa N, Kishima H, Shimosegawa E, Hatazawa J, Hashimoto N, Yoshimine T: (11)C-methionine uptake correlates with tumor cell density rather than with microvessel density in glioma: a stereotactic image-histology comparison. NeuroImage 2010, 49: 2977–2982. 10.1016/j.neuroimage.2009.11.024CrossRef
22.
go back to reference Takasu A, Shimosegawa T, Shimosegawa E, Hatazawa J, Kimura K, Fujita M, Koizumi M, Kanno I, Toyota T: 11C-methionine uptake to the pancreas and its secretion: a positron emission tomography study in humans. Pancreas 1999, 18: 392–398. 10.1097/00006676-199905000-00010CrossRef Takasu A, Shimosegawa T, Shimosegawa E, Hatazawa J, Kimura K, Fujita M, Koizumi M, Kanno I, Toyota T: 11C-methionine uptake to the pancreas and its secretion: a positron emission tomography study in humans. Pancreas 1999, 18: 392–398. 10.1097/00006676-199905000-00010CrossRef
23.
go back to reference Takasu A, Shimosegawa T, Shimosegawa E, Hatazawa J, Nagasaki Y, Kimura K, Fujita M, Toyota T: [11C]methionine positron emission tomography for the evaluation of pancreatic exocrine function in chronic pancreatitis. Pancreas 2001, 22: 203–209. 10.1097/00006676-200103000-00016CrossRef Takasu A, Shimosegawa T, Shimosegawa E, Hatazawa J, Nagasaki Y, Kimura K, Fujita M, Toyota T: [11C]methionine positron emission tomography for the evaluation of pancreatic exocrine function in chronic pancreatitis. Pancreas 2001, 22: 203–209. 10.1097/00006676-200103000-00016CrossRef
24.
go back to reference Otsuki K, Kenmochi T, Saigo K, Maruyama M, Akutsu N, Iwashita C, Kono T, Okazumi S, Asano T, Yoshikawa K: Evaluation of segmental pancreatic function using 11C-methionine positron emission tomography for safe operation of living donor pancreas transplantation. Transplant Proc 2008, 40: 2562–2564. 10.1016/j.transproceed.2008.08.067CrossRef Otsuki K, Kenmochi T, Saigo K, Maruyama M, Akutsu N, Iwashita C, Kono T, Okazumi S, Asano T, Yoshikawa K: Evaluation of segmental pancreatic function using 11C-methionine positron emission tomography for safe operation of living donor pancreas transplantation. Transplant Proc 2008, 40: 2562–2564. 10.1016/j.transproceed.2008.08.067CrossRef
25.
go back to reference Morooka M, Kubota K, Kadowaki H, Ito K, Okazaki O, Kashida M, Mitsumoto T, Iwata R, Ohtomo K, Hiroe M: 11C-methionine PET of acute myocardial infarction. J Nucl Med 2009, 50: 1283–1287. 10.2967/jnumed.108.061341CrossRef Morooka M, Kubota K, Kadowaki H, Ito K, Okazaki O, Kashida M, Mitsumoto T, Iwata R, Ohtomo K, Hiroe M: 11C-methionine PET of acute myocardial infarction. J Nucl Med 2009, 50: 1283–1287. 10.2967/jnumed.108.061341CrossRef
26.
go back to reference Enomoto K, Matsui Y, Okazumi S, Ioku T, Asano T, Isono K, Yoshikawa K, Itoh H, Imazeki K, Yoshida H, Uno K, Arimizu N: Evaluation of clinical usefulness of 11C-methionine positron emission tomography (11C-MET-PET) as a tool for liver functional imaging. Kaku Igaku 1994, 31: 271–275. Enomoto K, Matsui Y, Okazumi S, Ioku T, Asano T, Isono K, Yoshikawa K, Itoh H, Imazeki K, Yoshida H, Uno K, Arimizu N: Evaluation of clinical usefulness of 11C-methionine positron emission tomography (11C-MET-PET) as a tool for liver functional imaging. Kaku Igaku 1994, 31: 271–275.
27.
go back to reference Mejia AA, Nakamura T, Masatoshi I, Hatazawa J, Masaki M, Watanuki S: Estimation of absorbed doses in humans due to intravenous administration of fluorine-18-fluorodeoxyglucose in PET studies. J Nucl Med 1991, 32: 699–706. Mejia AA, Nakamura T, Masatoshi I, Hatazawa J, Masaki M, Watanuki S: Estimation of absorbed doses in humans due to intravenous administration of fluorine-18-fluorodeoxyglucose in PET studies. J Nucl Med 1991, 32: 699–706.
28.
go back to reference Oldendorf WH: Brain uptake of radiolabeled amino acids, amines, and hexoses after arterial injection. Am J Physiol 1971, 221: 1629–1639. Oldendorf WH: Brain uptake of radiolabeled amino acids, amines, and hexoses after arterial injection. Am J Physiol 1971, 221: 1629–1639.
29.
go back to reference Ito H, Hatazawa J, Murakami M, Miura S, Iida H, Bloomfield PM, Kanno I, Fukuda H, Uemura K: Aging effect on neutral amino acid transport at the blood–brain barrier measured with L-[2–18 F]-fluorophenylalanine and PET. J Nucl Med 1995, 36: 1232–1237. Ito H, Hatazawa J, Murakami M, Miura S, Iida H, Bloomfield PM, Kanno I, Fukuda H, Uemura K: Aging effect on neutral amino acid transport at the blood–brain barrier measured with L-[2–18 F]-fluorophenylalanine and PET. J Nucl Med 1995, 36: 1232–1237.
30.
go back to reference Delbeke D, Coleman RE, Guiberteau MJ, Brown ML, Royal HD, Siegel BA, Townsend DW, Berland LL, Parker JA, Hubner K, Stabin MG, Zubal G, Kachelriess M, Cronin V, Holbrook S: Procedure guideline for tumor imaging with 18 F-FDG PET/CT 1.0. J Nucl Med 2006, 47: 885–895. Delbeke D, Coleman RE, Guiberteau MJ, Brown ML, Royal HD, Siegel BA, Townsend DW, Berland LL, Parker JA, Hubner K, Stabin MG, Zubal G, Kachelriess M, Cronin V, Holbrook S: Procedure guideline for tumor imaging with 18 F-FDG PET/CT 1.0. J Nucl Med 2006, 47: 885–895.
31.
go back to reference Boellaard R, O’Doherty MJ, Weber WA, Mottaghy FM, Lonsdale MN, Stroobants SG, Oyen WJ, Kotzerke J, Hoekstra OS, Pruim J, Marsden PK, Tatsch K, Hoekstra CJ, Visser EP, Arends B, Verzijlbergen FJ, Zijlstra JM, Comans EF, Lammertsma AA, Paans AM, Willemsen AT, Beyer T, Bockisch A, Schaefer-Prokop C, Delbeke D, Baum RP, Chiti A, Krause BJ: FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0. Eur J Nucl Med Mol Imaging 2010, 37: 181–200. 10.1007/s00259-009-1297-4PubMedCentralCrossRef Boellaard R, O’Doherty MJ, Weber WA, Mottaghy FM, Lonsdale MN, Stroobants SG, Oyen WJ, Kotzerke J, Hoekstra OS, Pruim J, Marsden PK, Tatsch K, Hoekstra CJ, Visser EP, Arends B, Verzijlbergen FJ, Zijlstra JM, Comans EF, Lammertsma AA, Paans AM, Willemsen AT, Beyer T, Bockisch A, Schaefer-Prokop C, Delbeke D, Baum RP, Chiti A, Krause BJ: FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0. Eur J Nucl Med Mol Imaging 2010, 37: 181–200. 10.1007/s00259-009-1297-4PubMedCentralCrossRef
32.
go back to reference Lilja A, Bergström K, Hartvig P, Spännare B, Halldin C, Lundqvist H, Långstrom B: Dynamic study of supratentorial gliomas with L-methyl-11C-methionine and positron emission tomography. AJNR Am J Neuroradiol 1985, 6: 505–514. Lilja A, Bergström K, Hartvig P, Spännare B, Halldin C, Lundqvist H, Långstrom B: Dynamic study of supratentorial gliomas with L-methyl-11C-methionine and positron emission tomography. AJNR Am J Neuroradiol 1985, 6: 505–514.
33.
go back to reference Kubota K, Matsuzawa T, Ito M, Ito K, Fujiwara T, Abe Y, Yoshioka S, Fukuda H, Hatazawa J, Iwata R, Watanuki S, Ido T: Lung tumor imaging by positron emission tomography using C-11 L-methionine. J Nucl Med 1985, 26: 37–42. Kubota K, Matsuzawa T, Ito M, Ito K, Fujiwara T, Abe Y, Yoshioka S, Fukuda H, Hatazawa J, Iwata R, Watanuki S, Ido T: Lung tumor imaging by positron emission tomography using C-11 L-methionine. J Nucl Med 1985, 26: 37–42.
34.
go back to reference Hatazawa J, Ishiwata K, Itoh M, Kameyama M, Kubota K, Ido T, Matsuzawa T, Yoshimoto T, Watanuki S, Seo S: Quantitative evaluation of L-[methyl-C-11] methionine uptake in tumor using positron emission tomography. J Nucl Med 1989, 30: 1809–1813. Hatazawa J, Ishiwata K, Itoh M, Kameyama M, Kubota K, Ido T, Matsuzawa T, Yoshimoto T, Watanuki S, Seo S: Quantitative evaluation of L-[methyl-C-11] methionine uptake in tumor using positron emission tomography. J Nucl Med 1989, 30: 1809–1813.
Metadata
Title
Optimization of [11C]methionine PET study: appropriate scan timing and effect of plasma amino acid concentrations on the SUV
Authors
Kayako Isohashi
Eku Shimosegawa
Hiroki Kato
Yasukazu Kanai
Sadahiro Naka
Koichi Fujino
Hiroshi Watabe
Jun Hatazawa
Publication date
01-12-2013
Publisher
Springer Berlin Heidelberg
Published in
EJNMMI Research / Issue 1/2013
Electronic ISSN: 2191-219X
DOI
https://doi.org/10.1186/2191-219X-3-27

Other articles of this Issue 1/2013

EJNMMI Research 1/2013 Go to the issue