Skip to main content
Top
Published in: The Ultrasound Journal 1/2014

Open Access 01-12-2014 | Original article

Detection of soft tissue foreign bodies by nurse practitioner-performed ultrasound

Authors: Paul Atkinson, Rajeev Madan, Richard Kendall, Jacqueline Fraser, David Lewis

Published in: The Ultrasound Journal | Issue 1/2014

Login to get access

Abstract

Background

This study aimed to evaluate the accuracy of emergency nurse practitioner (NP)-performed point-of-care ultrasound (POCUS) for the detection of soft tissue foreign bodies (FBs).

Methods

Following a 2-h training session, ten NPs were assessed on their ability to detect various FBs in an experimental model. FBs (wood, metal and plastic) were inserted randomly into eight experimental models (uncooked chicken thighs) by an independent observer. Control experimental models had no FB inserted, but all had a 1-cm incision made on their surface. NPs, blinded to the type of model, were then assessed on their ability to detect the FBs by ultrasound examination using high-frequency linear transducers (Toshiba Nemio). Models were also scanned by two experienced emergency physicians (EPs) as a further control.

Results

Overall, NP-performed POCUS detected 47 of the 60 foreign bodies with a sensitivity, specificity, positive predictive value and negative predictive value of 78.3%, 50%, 82% and 43%, respectively, compared with 83.3%, 75%, 90.9% and 60% for EPs. Sensitivity for detecting specific types of FB was 95%, 85% and 50% for wood, metal and plastic, respectively, for NP-performed POCUS, compared with 100%, 100% and 50% in the EP group.

Conclusions

NPs with no previous ultrasound experience can detect soft tissue FBs with accuracy comparable to that of EPs in an experimental model. Test sensitivity was high for wood and metal foreign bodies. Specificity was generally low.
Appendix
Available only for authorised users
Literature
1.
go back to reference Noble VE, Nelson BP: Manual of emergency and critical care ultrasound. 2nd edition. Cambridge: Cambridge University Press; 2001. Noble VE, Nelson BP: Manual of emergency and critical care ultrasound. 2nd edition. Cambridge: Cambridge University Press; 2001.
2.
go back to reference Orlinsky M, Knittel P, Feit T, Chan L, Mandavia D: The comparative accuracy of radiolucent foreign body detection using ultrasonography. Am J Emerg Med 2000,18(4):401–403. 10.1053/ajem.2000.7315CrossRefPubMed Orlinsky M, Knittel P, Feit T, Chan L, Mandavia D: The comparative accuracy of radiolucent foreign body detection using ultrasonography. Am J Emerg Med 2000,18(4):401–403. 10.1053/ajem.2000.7315CrossRefPubMed
3.
go back to reference Nienaber A, Harvey M, Cave G: Accuracy of bedside ultrasound for the detection of soft tissue foreign bodies by emergency doctors. Emerg Med Australas 2010,22(1):30–34. 10.1111/j.1742-6723.2009.01255.xCrossRefPubMed Nienaber A, Harvey M, Cave G: Accuracy of bedside ultrasound for the detection of soft tissue foreign bodies by emergency doctors. Emerg Med Australas 2010,22(1):30–34. 10.1111/j.1742-6723.2009.01255.xCrossRefPubMed
4.
go back to reference Hill R, Conron R, Greissinger P, Heller M: Ultrasound for the detection of foreign bodies in human tissue. Ann Emerg Med 1997, 29: 353–356. 10.1016/S0196-0644(97)70347-0CrossRefPubMed Hill R, Conron R, Greissinger P, Heller M: Ultrasound for the detection of foreign bodies in human tissue. Ann Emerg Med 1997, 29: 353–356. 10.1016/S0196-0644(97)70347-0CrossRefPubMed
5.
go back to reference Blaivas M, Lyon M: The effect of ultrasound guidance on the perceived difficulty of emergency nurse-obtained peripheral IV access. J EMerg Med 2006,31(4):407–410. 10.1016/j.jemermed.2006.04.014CrossRefPubMed Blaivas M, Lyon M: The effect of ultrasound guidance on the perceived difficulty of emergency nurse-obtained peripheral IV access. J EMerg Med 2006,31(4):407–410. 10.1016/j.jemermed.2006.04.014CrossRefPubMed
6.
go back to reference Henderson SO, Ahern T, Williams D, Mailhot T, Mandavia D: Emergency department ultrasound by nurse practitioners. J Am Acad Nurse Pract 2010, 22: 352–355. 10.1111/j.1745-7599.2010.00518.xCrossRefPubMed Henderson SO, Ahern T, Williams D, Mailhot T, Mandavia D: Emergency department ultrasound by nurse practitioners. J Am Acad Nurse Pract 2010, 22: 352–355. 10.1111/j.1745-7599.2010.00518.xCrossRefPubMed
7.
go back to reference Imoisili MA, Bonwit AM, Bulas DI: Toothpick puncture injuries of the foot in children. Pediatr Infect Dis J 2004,23(1):80–82. 10.1097/00006454-200401000-00026CrossRefPubMed Imoisili MA, Bonwit AM, Bulas DI: Toothpick puncture injuries of the foot in children. Pediatr Infect Dis J 2004,23(1):80–82. 10.1097/00006454-200401000-00026CrossRefPubMed
Metadata
Title
Detection of soft tissue foreign bodies by nurse practitioner-performed ultrasound
Authors
Paul Atkinson
Rajeev Madan
Richard Kendall
Jacqueline Fraser
David Lewis
Publication date
01-12-2014
Publisher
Springer Milan
Published in
The Ultrasound Journal / Issue 1/2014
Electronic ISSN: 2524-8987
DOI
https://doi.org/10.1186/2036-7902-6-2

Other articles of this Issue 1/2014