Skip to main content
Top
Published in: Journal of Foot and Ankle Research 1/2014

Open Access 01-12-2014 | Research

Electromyography and sonomyography analysis of the tibialis anterior: a cross sectional study

Authors: Maria Ruiz-Muñoz, Antonio I Cuesta-Vargas

Published in: Journal of Foot and Ankle Research | Issue 1/2014

Login to get access

Abstract

Background

Foot dorsiflexion plays an essential role in both controlling balance and human gait. Electromyography (EMG) and sonomyography (SMG) can provide information on several aspects of muscle function. The aim was to establish the relationship between the EMG and SMG variables during isotonic contractions of foot dorsiflexors.

Methods

Twenty-seven healthy young adults performed the foot dorsiflexion test on a device designed ad hoc. EMG variables were maximum peak and area under the curve. Muscular architecture variables were muscle thickness and pennation angle. Descriptive statistical analysis, inferential analysis and a multivariate linear regression model were carried out. The confidence level was established with a statistically significant p-value of less than 0.05.

Results

The correlation between EMG variables and SMG variables was r = 0.462 (p < 0.05). The linear regression model to the dependent variable “peak normalized tibialis anterior (TA)” from the independent variables “pennation angle and thickness”, was significant (p = 0.002) with an explained variance of R2 = 0.693 and SEE = 0.16.

Conclusions

There is a significant relationship and degree of contribution between EMG and SMG variables during isotonic contractions of the TA muscle. Our results suggest that EMG and SMG can be feasible tools for monitoring and assessment of foot dorsiflexors. TA muscle parameterization and assessment is relevant in order to know that increased strength accelerates the recovery of lower limb injuries.
Appendix
Available only for authorised users
Literature
1.
go back to reference Mann RA, Hagy J: Biomechanics of walking, running, and sprinting. Am J Sports Med. 1980, 8: 345-350. 10.1177/036354658000800510.CrossRefPubMed Mann RA, Hagy J: Biomechanics of walking, running, and sprinting. Am J Sports Med. 1980, 8: 345-350. 10.1177/036354658000800510.CrossRefPubMed
2.
go back to reference Cornwall MW, McPoil TG: The influence of tibialis anterior muscle activity on rearfoot motion during walking. Foot Ankle Int. 1994, 15: 75-79. 10.1177/107110079401500205.CrossRefPubMed Cornwall MW, McPoil TG: The influence of tibialis anterior muscle activity on rearfoot motion during walking. Foot Ankle Int. 1994, 15: 75-79. 10.1177/107110079401500205.CrossRefPubMed
3.
go back to reference Daubney ME, Culham EG: Lower-extremity muscle force and balance performance in adults aged 65 years and older. Phys Ther. 1999, 79: 1177-1185.PubMed Daubney ME, Culham EG: Lower-extremity muscle force and balance performance in adults aged 65 years and older. Phys Ther. 1999, 79: 1177-1185.PubMed
4.
go back to reference Nilsson J, Thorstensson A, Halbertsma J: Changes in leg movements and muscle activity with speed of locomotion and mode of progression in humans. Acta Physiol Scand. 1985, 123: 457-475. 10.1111/j.1748-1716.1985.tb07612.x.CrossRefPubMed Nilsson J, Thorstensson A, Halbertsma J: Changes in leg movements and muscle activity with speed of locomotion and mode of progression in humans. Acta Physiol Scand. 1985, 123: 457-475. 10.1111/j.1748-1716.1985.tb07612.x.CrossRefPubMed
5.
go back to reference Burridge J, Taylor P, Hagan S, Swain I: Experience of clinical use of the Odstock dropped foot stimulator. Artif Organs. 1997, 21: 254-260. 10.1111/j.1525-1594.1997.tb04662.x.CrossRefPubMed Burridge J, Taylor P, Hagan S, Swain I: Experience of clinical use of the Odstock dropped foot stimulator. Artif Organs. 1997, 21: 254-260. 10.1111/j.1525-1594.1997.tb04662.x.CrossRefPubMed
6.
go back to reference Lee SE: Effects of increasing ankle range of motion program on ambulation and balance for the elderly with balance disorder. J Korean Acad Univ Trained Phys Ther. 2005, 12: 28-36. Lee SE: Effects of increasing ankle range of motion program on ambulation and balance for the elderly with balance disorder. J Korean Acad Univ Trained Phys Ther. 2005, 12: 28-36.
7.
go back to reference Woollacott MH, Shumway-Cook A, Nashner LM: Aging and posture control: changes in sensory organization and muscular coordination. Int J Aging Hum Dev. 1986, 23: 97-114. 10.2190/VXN3-N3RT-54JB-X16X.CrossRefPubMed Woollacott MH, Shumway-Cook A, Nashner LM: Aging and posture control: changes in sensory organization and muscular coordination. Int J Aging Hum Dev. 1986, 23: 97-114. 10.2190/VXN3-N3RT-54JB-X16X.CrossRefPubMed
8.
go back to reference Dobkin BH: The Clinical Science of Neurologic Rehabilitation. 2003, Oxford: Oxford University Press Dobkin BH: The Clinical Science of Neurologic Rehabilitation. 2003, Oxford: Oxford University Press
9.
go back to reference Zwarts MJ, Stegeman DF: Multichannel surface EMG: basic aspects and clinical utility. Muscle Nerve. 2003, 28: 1-17. 10.1002/mus.10358.CrossRefPubMed Zwarts MJ, Stegeman DF: Multichannel surface EMG: basic aspects and clinical utility. Muscle Nerve. 2003, 28: 1-17. 10.1002/mus.10358.CrossRefPubMed
10.
go back to reference Fukuda K, Umezu Y, Shiba N, Tajima F, Nagata K: Electromyographic fatigue analysis of back muscles during remote muscle contraction. J Back Musculoskelet Rehabil. 2006, 19: 61-66. Fukuda K, Umezu Y, Shiba N, Tajima F, Nagata K: Electromyographic fatigue analysis of back muscles during remote muscle contraction. J Back Musculoskelet Rehabil. 2006, 19: 61-66.
11.
go back to reference Haig AJ, Gelblum JB, Rechtien JJ, Gitter AJ: Technology assessment: the use of surface EMG in the diagnosis and treatment of nerve and muscle disorders. Muscle Nerve. 1996, 19: 392-395. 10.1002/(SICI)1097-4598(199603)19:3<392::AID-MUS21>3.0.CO;2-T.CrossRefPubMed Haig AJ, Gelblum JB, Rechtien JJ, Gitter AJ: Technology assessment: the use of surface EMG in the diagnosis and treatment of nerve and muscle disorders. Muscle Nerve. 1996, 19: 392-395. 10.1002/(SICI)1097-4598(199603)19:3<392::AID-MUS21>3.0.CO;2-T.CrossRefPubMed
12.
go back to reference Masuda K, Masuda T, Sadoyama T, Inaki M, Katsuta S: Changes in surface EMG parameters during static and dynamic fatiguing contractions. J Electromyogr Kinesiol. 1999, 9: 39-46. 10.1016/S1050-6411(98)00021-2.CrossRefPubMed Masuda K, Masuda T, Sadoyama T, Inaki M, Katsuta S: Changes in surface EMG parameters during static and dynamic fatiguing contractions. J Electromyogr Kinesiol. 1999, 9: 39-46. 10.1016/S1050-6411(98)00021-2.CrossRefPubMed
13.
go back to reference Hogrel JY: Clinical applications of surface electromyography in neuromuscular disorders. Neurophysiol Clin. 2005, 35: 59-71. 10.1016/j.neucli.2005.03.001.CrossRefPubMed Hogrel JY: Clinical applications of surface electromyography in neuromuscular disorders. Neurophysiol Clin. 2005, 35: 59-71. 10.1016/j.neucli.2005.03.001.CrossRefPubMed
14.
go back to reference Boostani R, Moradi MH: Evaluation of the forearm EMG signal features for the control of a prosthetic hand. Physiol Meas. 2003, 24: 309-319. 10.1088/0967-3334/24/2/307.CrossRefPubMed Boostani R, Moradi MH: Evaluation of the forearm EMG signal features for the control of a prosthetic hand. Physiol Meas. 2003, 24: 309-319. 10.1088/0967-3334/24/2/307.CrossRefPubMed
15.
go back to reference Soares A, Andrade A, Lamounier E, Carrijo R: The development of a virtual myoelectric prosthesis controlled by an EMG pattern recognition system based on neural networks. J Intell Inf Syst. 2003, 21: 127-141. 10.1023/A:1024758415877.CrossRef Soares A, Andrade A, Lamounier E, Carrijo R: The development of a virtual myoelectric prosthesis controlled by an EMG pattern recognition system based on neural networks. J Intell Inf Syst. 2003, 21: 127-141. 10.1023/A:1024758415877.CrossRef
16.
go back to reference Shi J, Zheng YP, Chen X, Huang QH: Assessment of muscle fatigue using sonomyography: muscle thickness change detected from ultrasound images. Med Eng Phys. 2007, 29: 472-479. 10.1016/j.medengphy.2006.07.004.CrossRefPubMed Shi J, Zheng YP, Chen X, Huang QH: Assessment of muscle fatigue using sonomyography: muscle thickness change detected from ultrasound images. Med Eng Phys. 2007, 29: 472-479. 10.1016/j.medengphy.2006.07.004.CrossRefPubMed
17.
go back to reference Shi J, Zheng Y-P, Huang Q-H, Chen X: Continuous monitoring of sonomyography, electromyography and torque generated by normal upper arm muscles during isometric contraction: sonomyography assessment for arm muscles. IEEE Trans Biomed Eng. 2008, 55: 1191-1198.CrossRefPubMed Shi J, Zheng Y-P, Huang Q-H, Chen X: Continuous monitoring of sonomyography, electromyography and torque generated by normal upper arm muscles during isometric contraction: sonomyography assessment for arm muscles. IEEE Trans Biomed Eng. 2008, 55: 1191-1198.CrossRefPubMed
18.
go back to reference Zhou Y, Zheng Y-P: Estimation of muscle fiber orientation in ultrasound images using revoting hough transform (RVHT). Ultrasound Med Bio. 2008, 34: 1474-1481. 10.1016/j.ultrasmedbio.2008.02.009.CrossRef Zhou Y, Zheng Y-P: Estimation of muscle fiber orientation in ultrasound images using revoting hough transform (RVHT). Ultrasound Med Bio. 2008, 34: 1474-1481. 10.1016/j.ultrasmedbio.2008.02.009.CrossRef
19.
go back to reference Guo J-Y, Zheng Y-P, Huang Q-H, Chen X: Dynamic monitoring of forearm muscles using one-dimensional sonomyography system. J Rehabil Res Dev. 2008, 45: 187-195. 10.1682/JRRD.2007.02.0026.CrossRefPubMed Guo J-Y, Zheng Y-P, Huang Q-H, Chen X: Dynamic monitoring of forearm muscles using one-dimensional sonomyography system. J Rehabil Res Dev. 2008, 45: 187-195. 10.1682/JRRD.2007.02.0026.CrossRefPubMed
20.
go back to reference Xie H-B, Zheng Y-P, Guo J-Y, Chen X, Shi J: Estimation of wrist angle from sonomyography using support vector machine and artificial neural network models. Med Eng Phys. 2009, 31: 384-391. 10.1016/j.medengphy.2008.05.005.CrossRefPubMed Xie H-B, Zheng Y-P, Guo J-Y, Chen X, Shi J: Estimation of wrist angle from sonomyography using support vector machine and artificial neural network models. Med Eng Phys. 2009, 31: 384-391. 10.1016/j.medengphy.2008.05.005.CrossRefPubMed
21.
go back to reference Zheng YP, Chan MMF, Shi J, Chen X, Huang QH: Sonomyography: monitoring morphological changes of forearm muscles in actions with the feasibility for the control of powered prosthesis. Med Eng Phys. 2006, 28: 405-415. 10.1016/j.medengphy.2005.07.012.CrossRefPubMed Zheng YP, Chan MMF, Shi J, Chen X, Huang QH: Sonomyography: monitoring morphological changes of forearm muscles in actions with the feasibility for the control of powered prosthesis. Med Eng Phys. 2006, 28: 405-415. 10.1016/j.medengphy.2005.07.012.CrossRefPubMed
22.
go back to reference Brancaccio P, Limongelli FM, D’Aponte A, Narici M, Maffulli N: Changes in skeletal muscle architecture following a cycloergometer test to exhaustion in athletes. J Sci Med Sport. 2008, 11: 538-541. 10.1016/j.jsams.2007.05.011.CrossRefPubMed Brancaccio P, Limongelli FM, D’Aponte A, Narici M, Maffulli N: Changes in skeletal muscle architecture following a cycloergometer test to exhaustion in athletes. J Sci Med Sport. 2008, 11: 538-541. 10.1016/j.jsams.2007.05.011.CrossRefPubMed
23.
go back to reference Legerlotz K, Smith HK, Hing WA: Variation and reliability of ultrasonographic quantification of the architecture of the medial gastrocnemius muscle in young children. Clin Physiol Funct Imaging. 2010, 30: 198-205. 10.1111/j.1475-097X.2010.00925.x.CrossRefPubMed Legerlotz K, Smith HK, Hing WA: Variation and reliability of ultrasonographic quantification of the architecture of the medial gastrocnemius muscle in young children. Clin Physiol Funct Imaging. 2010, 30: 198-205. 10.1111/j.1475-097X.2010.00925.x.CrossRefPubMed
24.
go back to reference Rutherford OM, Jones DA: Measurement of fiber pennation using ultrasound in the human quadriceps in vivo. Eur J Appl Physiol Occup Physiol. 1992, 65: 433-437. 10.1007/BF00243510.CrossRefPubMed Rutherford OM, Jones DA: Measurement of fiber pennation using ultrasound in the human quadriceps in vivo. Eur J Appl Physiol Occup Physiol. 1992, 65: 433-437. 10.1007/BF00243510.CrossRefPubMed
25.
go back to reference Fukunaga T, Ichinose Y, Ito M, Kawakami Y, Fukashiro S: Determination of fascicle length and pennation in a contracting human muscle in vivo. J Appl Physiol (1985). 1997, 82: 354-358. Fukunaga T, Ichinose Y, Ito M, Kawakami Y, Fukashiro S: Determination of fascicle length and pennation in a contracting human muscle in vivo. J Appl Physiol (1985). 1997, 82: 354-358.
26.
go back to reference Reeves ND, Maganaris CN, Narici MV: Ultrasonographic assessment of human skeletal muscle size. Eur J Appl Physiol. 2004, 91: 116-118. 10.1007/s00421-003-0961-9.CrossRefPubMed Reeves ND, Maganaris CN, Narici MV: Ultrasonographic assessment of human skeletal muscle size. Eur J Appl Physiol. 2004, 91: 116-118. 10.1007/s00421-003-0961-9.CrossRefPubMed
27.
go back to reference Fukunaga T, Kawakami Y, Kuno S, Funato K, Fukashiro S: Muscle architecture and function in humans. J Biomech. 1997, 30: 457-463. 10.1016/S0021-9290(96)00171-6.CrossRefPubMed Fukunaga T, Kawakami Y, Kuno S, Funato K, Fukashiro S: Muscle architecture and function in humans. J Biomech. 1997, 30: 457-463. 10.1016/S0021-9290(96)00171-6.CrossRefPubMed
28.
go back to reference Hodges PW, Pengel LHM, Herbert RD, Gandevia SC: Measurement of muscle contraction with ultrasound imaging. Muscle Nerve. 2003, 27: 682-692. 10.1002/mus.10375.CrossRefPubMed Hodges PW, Pengel LHM, Herbert RD, Gandevia SC: Measurement of muscle contraction with ultrasound imaging. Muscle Nerve. 2003, 27: 682-692. 10.1002/mus.10375.CrossRefPubMed
29.
go back to reference Lloyd D: EMG-Assisted neuromuscular skeletal modelling: going beyond emg to assess the action of muscles in movement. Proceedings of the XIXth Congress of the International Society of Electrophysiology & Kinesiology: 19-21 July. 2012, Brisbane, Australia, 31 Lloyd D: EMG-Assisted neuromuscular skeletal modelling: going beyond emg to assess the action of muscles in movement. Proceedings of the XIXth Congress of the International Society of Electrophysiology & Kinesiology: 19-21 July. 2012, Brisbane, Australia, 31
30.
go back to reference Whittaker JL, Warner MB, Stokes M: Comparison of the sonographic features of the abdominal wall muscles and connective tissues in individuals with and without lumbopelvic pain. J Orthop Sports Phys Ther. 2013, 43: 11-19. 10.2519/jospt.2013.4450.CrossRefPubMed Whittaker JL, Warner MB, Stokes M: Comparison of the sonographic features of the abdominal wall muscles and connective tissues in individuals with and without lumbopelvic pain. J Orthop Sports Phys Ther. 2013, 43: 11-19. 10.2519/jospt.2013.4450.CrossRefPubMed
31.
go back to reference Brown SHM, McGill SM: A comparison of ultrasound and electromyography measures of force and activation to examine the mechanics of abdominal wall contraction. Clin Biomech (Bristol, Avon). 2010, 25: 115-123. 10.1016/j.clinbiomech.2009.10.001.CrossRef Brown SHM, McGill SM: A comparison of ultrasound and electromyography measures of force and activation to examine the mechanics of abdominal wall contraction. Clin Biomech (Bristol, Avon). 2010, 25: 115-123. 10.1016/j.clinbiomech.2009.10.001.CrossRef
32.
go back to reference Stokes M, Hides J, Elliott J, Kiesel K, Hodges P: Rehabilitative ultrasound imaging of the posterior paraspinal muscles. J Orthop Sports Phys Ther. 2007, 37: 581-595. 10.2519/jospt.2007.2599.CrossRefPubMed Stokes M, Hides J, Elliott J, Kiesel K, Hodges P: Rehabilitative ultrasound imaging of the posterior paraspinal muscles. J Orthop Sports Phys Ther. 2007, 37: 581-595. 10.2519/jospt.2007.2599.CrossRefPubMed
33.
go back to reference Masuda T, Miyamoto K, Oguri K, Matsuoka T, Shimizu K: Relationship between the thickness and hemodynamics of the erector spinae muscles in various lumbar curvatures. Clin Biomech (Bristol, Avon). 2005, 20: 247-253. 10.1016/j.clinbiomech.2004.10.008.CrossRef Masuda T, Miyamoto K, Oguri K, Matsuoka T, Shimizu K: Relationship between the thickness and hemodynamics of the erector spinae muscles in various lumbar curvatures. Clin Biomech (Bristol, Avon). 2005, 20: 247-253. 10.1016/j.clinbiomech.2004.10.008.CrossRef
34.
go back to reference Watanabe K, Miyamoto K, Masuda T, Shimizu K: Use of ultrasonography to evaluate thickness of the erector spinae muscle in maximum flexion and extension of the lumbar spine. Spine. 2004, 29: 1472-1477. 10.1097/01.BRS.0000128755.84693.10.CrossRefPubMed Watanabe K, Miyamoto K, Masuda T, Shimizu K: Use of ultrasonography to evaluate thickness of the erector spinae muscle in maximum flexion and extension of the lumbar spine. Spine. 2004, 29: 1472-1477. 10.1097/01.BRS.0000128755.84693.10.CrossRefPubMed
35.
go back to reference Masuda T, Miyamoto K, Shimizu K: Intramuscular hemodynamics in bilateral erector spinae muscles in symmetrical and asymmetrical postures with and without loading. Clin Biomech (Bristol, Avon). 2006, 21: 245-253. 10.1016/j.clinbiomech.2005.10.008.CrossRef Masuda T, Miyamoto K, Shimizu K: Intramuscular hemodynamics in bilateral erector spinae muscles in symmetrical and asymmetrical postures with and without loading. Clin Biomech (Bristol, Avon). 2006, 21: 245-253. 10.1016/j.clinbiomech.2005.10.008.CrossRef
36.
go back to reference Cuesta-Vargas AI, Gonález-Sánchez M: Relationship of moderate and low isometric lumbar extension through architectural and muscular activity variables: a cross sectional study. BMC Med Imaging. 2013, 13: 38-10.1186/1471-2342-13-38.CrossRefPubMedPubMedCentral Cuesta-Vargas AI, Gonález-Sánchez M: Relationship of moderate and low isometric lumbar extension through architectural and muscular activity variables: a cross sectional study. BMC Med Imaging. 2013, 13: 38-10.1186/1471-2342-13-38.CrossRefPubMedPubMedCentral
37.
go back to reference Huang QH, Zheng YP, Chena X, He JF, Shi J: A system for the synchronized recording of sonomyography, electromyography and joint angle. Open Biomed Eng J. 2007, 1: 77-84. 10.2174/1874120700701010077.CrossRefPubMedPubMedCentral Huang QH, Zheng YP, Chena X, He JF, Shi J: A system for the synchronized recording of sonomyography, electromyography and joint angle. Open Biomed Eng J. 2007, 1: 77-84. 10.2174/1874120700701010077.CrossRefPubMedPubMedCentral
38.
go back to reference Manal K, Roberts DP, Buchanan TS: Can pennation angles be predicted from EMGs for the primary ankle plantar and dorsiflexors during isometric contractions?. J Biomech. 2008, 41: 2492-2497. 10.1016/j.jbiomech.2008.05.005.CrossRefPubMedPubMedCentral Manal K, Roberts DP, Buchanan TS: Can pennation angles be predicted from EMGs for the primary ankle plantar and dorsiflexors during isometric contractions?. J Biomech. 2008, 41: 2492-2497. 10.1016/j.jbiomech.2008.05.005.CrossRefPubMedPubMedCentral
39.
go back to reference Guo J-Y, Zheng Y-P, Xie H-B, Chen X: Continuous monitoring of electromyography (EMG), mechanomyography (MMG), sonomyography (SMG) and torque output during ramp and step isometric contractions. Med Eng Phys. 2010, 32: 1032-1042. 10.1016/j.medengphy.2010.07.004.CrossRefPubMed Guo J-Y, Zheng Y-P, Xie H-B, Chen X: Continuous monitoring of electromyography (EMG), mechanomyography (MMG), sonomyography (SMG) and torque output during ramp and step isometric contractions. Med Eng Phys. 2010, 32: 1032-1042. 10.1016/j.medengphy.2010.07.004.CrossRefPubMed
40.
go back to reference Kim EJ, Kim TS, Bae SS: Fall-related injury and balance of the elderly. J Korean Acad Univ Trained Phys Ther. 1998, 10: 161-171. Kim EJ, Kim TS, Bae SS: Fall-related injury and balance of the elderly. J Korean Acad Univ Trained Phys Ther. 1998, 10: 161-171.
46.
go back to reference Cohen J: Statistical Power Analysis for the Behavioral Sciences. 1988, New Jersey: Lawrence Erlbaum Associates Cohen J: Statistical Power Analysis for the Behavioral Sciences. 1988, New Jersey: Lawrence Erlbaum Associates
47.
go back to reference Cohen J: Statistical Power Analysis for the Behavioral Sciences. 1987, Hillsdale, New Jersey: L. Erlbaum Associates Cohen J: Statistical Power Analysis for the Behavioral Sciences. 1987, Hillsdale, New Jersey: L. Erlbaum Associates
48.
go back to reference Guo J-Y, Zheng Y-P, Kenney LP, Xie H-B: Evaluation of sonomyography (SMG) for control compared with electromyography (EMG) in a discrete target tracking task. Conf Proc IEEE Eng Med Biol Soc. 2009, 2009: 1549-1552.PubMed Guo J-Y, Zheng Y-P, Kenney LP, Xie H-B: Evaluation of sonomyography (SMG) for control compared with electromyography (EMG) in a discrete target tracking task. Conf Proc IEEE Eng Med Biol Soc. 2009, 2009: 1549-1552.PubMed
49.
go back to reference Shi J, Chang Q, Zheng Y-P: Feasibility of controlling prosthetic hand using sonomyography signal in real time: preliminary study. J Rehabil Res Dev. 2010, 47: 87-98. 10.1682/JRRD.2009.03.0031.CrossRefPubMed Shi J, Chang Q, Zheng Y-P: Feasibility of controlling prosthetic hand using sonomyography signal in real time: preliminary study. J Rehabil Res Dev. 2010, 47: 87-98. 10.1682/JRRD.2009.03.0031.CrossRefPubMed
50.
go back to reference Ghori GM, Donne B, Luckwill RG: Relationship between torque and EMG activity of a knee extensor muscle during isokinetic concentric and eccentric actions. J Electromyogr Kinesiol. 1995, 5: 109-115. 10.1016/1050-6411(94)00013-C.CrossRefPubMed Ghori GM, Donne B, Luckwill RG: Relationship between torque and EMG activity of a knee extensor muscle during isokinetic concentric and eccentric actions. J Electromyogr Kinesiol. 1995, 5: 109-115. 10.1016/1050-6411(94)00013-C.CrossRefPubMed
51.
go back to reference Maganaris CN, Baltzopoulos V: Predictability of in vivo changes in pennation angle of human tibialis anterior muscle from rest to maximum isometric dorsiflexion. Eur J Appl Physiol Occup Physiol. 1999, 79: 294-297. 10.1007/s004210050510.CrossRefPubMed Maganaris CN, Baltzopoulos V: Predictability of in vivo changes in pennation angle of human tibialis anterior muscle from rest to maximum isometric dorsiflexion. Eur J Appl Physiol Occup Physiol. 1999, 79: 294-297. 10.1007/s004210050510.CrossRefPubMed
52.
go back to reference Shi J, Zheng Y, Yan Z, Huang Q: Preliminary study of skeletal muscle with multi-signals during isometric contraction. Conf Proc IEEE Eng Med Biol Soc. 2006, 1: 5080-5083.PubMed Shi J, Zheng Y, Yan Z, Huang Q: Preliminary study of skeletal muscle with multi-signals during isometric contraction. Conf Proc IEEE Eng Med Biol Soc. 2006, 1: 5080-5083.PubMed
53.
go back to reference Shi J, Zheng Y, Yan Z: SVM for estimation of wrist angle from sonomyography and SEMG signals. Conf Proc IEEE Eng Med Biol Soc. 2007, 2007: 4806-4809.PubMed Shi J, Zheng Y, Yan Z: SVM for estimation of wrist angle from sonomyography and SEMG signals. Conf Proc IEEE Eng Med Biol Soc. 2007, 2007: 4806-4809.PubMed
Metadata
Title
Electromyography and sonomyography analysis of the tibialis anterior: a cross sectional study
Authors
Maria Ruiz-Muñoz
Antonio I Cuesta-Vargas
Publication date
01-12-2014
Publisher
BioMed Central
Published in
Journal of Foot and Ankle Research / Issue 1/2014
Electronic ISSN: 1757-1146
DOI
https://doi.org/10.1186/1757-1146-7-11

Other articles of this Issue 1/2014

Journal of Foot and Ankle Research 1/2014 Go to the issue