Skip to main content
Top
Published in: Patient Safety in Surgery 1/2009

Open Access 01-12-2009 | Research

Collagen fleece-bound fibrin sealant is not associated with an increased risk of thromboembolic events or major bleeding after its use for haemostasis in surgery: a prospective multicentre surveillance study

Authors: Mathias Birth, Joan Figueras, Stéphane Bernardini, Tine Troen, Klaus Günther, Darius Mirza, Frank Viborg Mortensen

Published in: Patient Safety in Surgery | Issue 1/2009

Login to get access

Abstract

Background

Topical haemostatic agents are used to help achieve haemostasis during surgery when standard surgical techniques are insufficient. The objective of this study was to confirm the safety profile of an equine collagen patch coated with human fibrinogen and human thrombin with particular focus on the occurrence of thromboembolic events (TEEs), major bleeding and immunological events.

Methods

This was a non-interventional, multicentre, prospective, surveillance study in which a collagen fleece-bound fibrin sealant was prescribed in accordance with its marketing authorisation. The decision to use the sealant was based solely on current surgical practice. All patients that received the sealant and provided informed consent were included. TEEs (any coagula-based occlusion in a vessel or the heart identified by symptomatic clinical signs and/or verified by paraclinical examination), major bleeding (any bleeding that required intervention), and immunological events (hypersensitivity including anaphylaxis) that occurred during surgery, post-operative hospital stay or 6 months of follow-up were reported as adverse events. The primary endpoint was the proportion of patients experiencing a confirmed TEE.

Results

A total of 3098 patients were recruited at 227 centres in 12 European countries. The most frequent types of surgery were hepatic (33%), gastrointestinal (16%) and urological (14%) and the main indication for surgery was for primary (35%) or secondary (20%) malignancy. Forty-six patients (1.5%, 95% CI 1.1–2.0%) had at least one TEE during the study. The most commonly reported TEEs were pulmonary embolism or post-procedural pulmonary embolism (n = 18) and deep vein thrombosis (n = 9). There were 64 major bleedings in 62 patients and 9 immunological events in 8 patients.

Conclusion

Collagen fleece-bound fibrin sealant does not appear to be associated with an increased risk of TEEs, major bleeding or immunological events in patients undergoing surgery.

Trial registration

Clinicaltrials.gov number: NCT00285623
Appendix
Available only for authorised users
Literature
1.
go back to reference Bechstein WO, Strey C: Local and systemic hemostasis in surgery. Chirurg. 2007, 78: 95-100. 10.1007/s00104-006-1289-x.CrossRefPubMed Bechstein WO, Strey C: Local and systemic hemostasis in surgery. Chirurg. 2007, 78: 95-100. 10.1007/s00104-006-1289-x.CrossRefPubMed
2.
go back to reference Mankad PS, Codispoti M: The role of fibrin sealants in hemostasis. Am J Surg. 2001, 182 (2 Suppl): 21S-28S.CrossRefPubMed Mankad PS, Codispoti M: The role of fibrin sealants in hemostasis. Am J Surg. 2001, 182 (2 Suppl): 21S-28S.CrossRefPubMed
3.
go back to reference Seyednejad H, Imani M, Jamieson T, Seifalian AM: Topical haemostatic agents. Br J Surg. 2008, 95: 1197-1225. 10.1002/bjs.6357.CrossRefPubMed Seyednejad H, Imani M, Jamieson T, Seifalian AM: Topical haemostatic agents. Br J Surg. 2008, 95: 1197-1225. 10.1002/bjs.6357.CrossRefPubMed
4.
go back to reference Erdogan D, de Graaf W, van Gulik TM: Adhesive strength of fibrinogen-coated collagen patch or liquid fibrin sealant in an experimental liver resection model in pigs. Eur Surg Res. 2008, 41: 298-302. 10.1159/000155879.CrossRefPubMed Erdogan D, de Graaf W, van Gulik TM: Adhesive strength of fibrinogen-coated collagen patch or liquid fibrin sealant in an experimental liver resection model in pigs. Eur Surg Res. 2008, 41: 298-302. 10.1159/000155879.CrossRefPubMed
5.
go back to reference Carbon RT: Evaluation of biodegradable fleece-bound sealing: history, material science, and clinical application in tissue engineering and biodegradable equivalents. Scientific and clinical applications. Edited by: Lewandrowski K-U, Wise DL, Trantolo DJ, Gresser JD, Yaszemski MJ, Altobelli DE. 2002, Marcel Dekker, 587-650. Carbon RT: Evaluation of biodegradable fleece-bound sealing: history, material science, and clinical application in tissue engineering and biodegradable equivalents. Scientific and clinical applications. Edited by: Lewandrowski K-U, Wise DL, Trantolo DJ, Gresser JD, Yaszemski MJ, Altobelli DE. 2002, Marcel Dekker, 587-650.
6.
go back to reference Frilling A, Stavrou GA, Mischinger HJ, de Hemptinne B, Rokkjaer M, Klempnauer J, Thörne A, Gloor B, Beckebaum S, Ghaffar MF, Broelsch CE: Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection: a randomised prospective trial. Langenbecks Arch Surg. 2005, 390: 114-120. 10.1007/s00423-005-0543-x.CrossRefPubMed Frilling A, Stavrou GA, Mischinger HJ, de Hemptinne B, Rokkjaer M, Klempnauer J, Thörne A, Gloor B, Beckebaum S, Ghaffar MF, Broelsch CE: Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection: a randomised prospective trial. Langenbecks Arch Surg. 2005, 390: 114-120. 10.1007/s00423-005-0543-x.CrossRefPubMed
7.
go back to reference Siemer S, Lahme S, Altziebler S, Machtens S, Strohmaier W, Wechsel HW, Goebell P, Schmeller N, Oberneder R, Stolzenburg JU, Becker H, Lüftenegger W, Tetens V, Van Poppel H: Efficacy and safety of TachoSil as haemostatic treatment versus standard suturing in kidney tumour resection: a randomised prospective study. Eur Urol. 2007, 52: 1156-1163. 10.1016/j.eururo.2007.04.027.CrossRefPubMed Siemer S, Lahme S, Altziebler S, Machtens S, Strohmaier W, Wechsel HW, Goebell P, Schmeller N, Oberneder R, Stolzenburg JU, Becker H, Lüftenegger W, Tetens V, Van Poppel H: Efficacy and safety of TachoSil as haemostatic treatment versus standard suturing in kidney tumour resection: a randomised prospective study. Eur Urol. 2007, 52: 1156-1163. 10.1016/j.eururo.2007.04.027.CrossRefPubMed
8.
go back to reference Lang G, Csekeö A, Stamatis G, Lampl L, Hagman L, Marta GM, Mueller MR, Klepetko W: Efficacy and safety of topical application of human fibrinogen/thrombin-coated collagen patch (TachoComb) for treatment of air leakage after standard lobectomy. Eur J Cardiothorac Surg. 2004, 25: 160-166. 10.1016/j.ejcts.2003.11.018.CrossRefPubMed Lang G, Csekeö A, Stamatis G, Lampl L, Hagman L, Marta GM, Mueller MR, Klepetko W: Efficacy and safety of topical application of human fibrinogen/thrombin-coated collagen patch (TachoComb) for treatment of air leakage after standard lobectomy. Eur J Cardiothorac Surg. 2004, 25: 160-166. 10.1016/j.ejcts.2003.11.018.CrossRefPubMed
9.
go back to reference Anegg U, Lindenmann J, Matzi V, Smolle J, Maier A, Smolle-Jüttner F: Efficiency of fleece-bound sealing (TachoSil) of air leaks in lung surgery: a prospective randomised trial. Eur J Cardiothorac Surg. 2007, 31: 198-1202. 10.1016/j.ejcts.2006.11.033.CrossRefPubMed Anegg U, Lindenmann J, Matzi V, Smolle J, Maier A, Smolle-Jüttner F: Efficiency of fleece-bound sealing (TachoSil) of air leaks in lung surgery: a prospective randomised trial. Eur J Cardiothorac Surg. 2007, 31: 198-1202. 10.1016/j.ejcts.2006.11.033.CrossRefPubMed
10.
go back to reference Czerny M, Fleck T, Salat A, Zimpfer D, Klepetko W, Wolner E, Mueller MR: Sealing of the mediastinum with a local hemostyptic agent reduces chest tube duration after complete mediastinal lymph node dissection for stage I and II non-small cell lung carcinoma. Ann Thorac Surg. 2004, 77: 1028-1032. 10.1016/j.athoracsur.2003.08.041.CrossRefPubMed Czerny M, Fleck T, Salat A, Zimpfer D, Klepetko W, Wolner E, Mueller MR: Sealing of the mediastinum with a local hemostyptic agent reduces chest tube duration after complete mediastinal lymph node dissection for stage I and II non-small cell lung carcinoma. Ann Thorac Surg. 2004, 77: 1028-1032. 10.1016/j.athoracsur.2003.08.041.CrossRefPubMed
11.
go back to reference Haas S: The use of a surgical patch coated with human coagulation factors in surgical routine: a multicenter postauthorization surveillance. Clin Appl Thromb Hemost. 2006, 12: 445-450. 10.1177/1076029606293420.CrossRefPubMed Haas S: The use of a surgical patch coated with human coagulation factors in surgical routine: a multicenter postauthorization surveillance. Clin Appl Thromb Hemost. 2006, 12: 445-450. 10.1177/1076029606293420.CrossRefPubMed
12.
go back to reference Clagett GP, Reisch JS: Prevention of venous thromboembolism in general surgical patients. Results of meta-analysis. Ann Surg. 1988, 208: 227-240. 10.1097/00000658-198808000-00016.PubMedCentralCrossRefPubMed Clagett GP, Reisch JS: Prevention of venous thromboembolism in general surgical patients. Results of meta-analysis. Ann Surg. 1988, 208: 227-240. 10.1097/00000658-198808000-00016.PubMedCentralCrossRefPubMed
13.
go back to reference Mismetti P, Laporte S, Darmon JY, Buchmüller A, Decousus H: Meta-analysis of low molecular weight heparin in the prevention of venous thromboembolism in general surgery. Br J Surg. 2001, 88: 913-30. 10.1046/j.0007-1323.2001.01800.x.CrossRefPubMed Mismetti P, Laporte S, Darmon JY, Buchmüller A, Decousus H: Meta-analysis of low molecular weight heparin in the prevention of venous thromboembolism in general surgery. Br J Surg. 2001, 88: 913-30. 10.1046/j.0007-1323.2001.01800.x.CrossRefPubMed
14.
go back to reference Bottaro FJ, Elizondo MC, Doti C, Bruetman JE, Perez Moreno PD, Bullorsky EO, Ceresetto JM: Efficacy of extended thrombo-prophylaxis in major abdominal surgery: what does the evidence show? A meta-analysis. Thromb Haemost. 2008, 99: 1104-1111.PubMed Bottaro FJ, Elizondo MC, Doti C, Bruetman JE, Perez Moreno PD, Bullorsky EO, Ceresetto JM: Efficacy of extended thrombo-prophylaxis in major abdominal surgery: what does the evidence show? A meta-analysis. Thromb Haemost. 2008, 99: 1104-1111.PubMed
15.
go back to reference Marik PE, Corwin HL: Efficacy of red blood cell transfusion in the critically ill: a systematic review of the literature. Crit Care Med. 2008, 36: 2667-2674. 10.1097/CCM.0b013e3181844677.CrossRefPubMed Marik PE, Corwin HL: Efficacy of red blood cell transfusion in the critically ill: a systematic review of the literature. Crit Care Med. 2008, 36: 2667-2674. 10.1097/CCM.0b013e3181844677.CrossRefPubMed
16.
go back to reference Rapaport SI, Zivelin A, Minow RA, Hunter CS, Donnelly K: Clinical significance of antibodies to bovine and human thrombin and factor V after surgical use of bovine thrombin. Am J Clin Pathol. 1992, 97: 84-91.PubMed Rapaport SI, Zivelin A, Minow RA, Hunter CS, Donnelly K: Clinical significance of antibodies to bovine and human thrombin and factor V after surgical use of bovine thrombin. Am J Clin Pathol. 1992, 97: 84-91.PubMed
17.
go back to reference Berruyer M, Amiral J, Ffrench P, Belleville J, Bastien O, Clerc J, Kassir A, Estanove S, Dechavanne M: Immunization by bovine thrombin used with fibrin glue during cardiovascular operations. Development of thrombin and factor V inhibitors. J Thorac Cardiovasc Surg. 1993, 105: 892-897.PubMed Berruyer M, Amiral J, Ffrench P, Belleville J, Bastien O, Clerc J, Kassir A, Estanove S, Dechavanne M: Immunization by bovine thrombin used with fibrin glue during cardiovascular operations. Development of thrombin and factor V inhibitors. J Thorac Cardiovasc Surg. 1993, 105: 892-897.PubMed
18.
go back to reference Streiff MB, Ness PM: Acquired FV inhibitors: a needless iatrogenic complication of bovine thrombin exposure. Transfusion. 2002, 42: 18-26. 10.1046/j.1537-2995.2002.00011.x.CrossRefPubMed Streiff MB, Ness PM: Acquired FV inhibitors: a needless iatrogenic complication of bovine thrombin exposure. Transfusion. 2002, 42: 18-26. 10.1046/j.1537-2995.2002.00011.x.CrossRefPubMed
19.
go back to reference Adelmann-Grill BC, Otto K: Immunological safety evaluation of a haemostatic agent and wound dressing made of horse collagen fibrils. Arzneimittelforschung. 1987, 37: 802-805.PubMed Adelmann-Grill BC, Otto K: Immunological safety evaluation of a haemostatic agent and wound dressing made of horse collagen fibrils. Arzneimittelforschung. 1987, 37: 802-805.PubMed
Metadata
Title
Collagen fleece-bound fibrin sealant is not associated with an increased risk of thromboembolic events or major bleeding after its use for haemostasis in surgery: a prospective multicentre surveillance study
Authors
Mathias Birth
Joan Figueras
Stéphane Bernardini
Tine Troen
Klaus Günther
Darius Mirza
Frank Viborg Mortensen
Publication date
01-12-2009
Publisher
BioMed Central
Published in
Patient Safety in Surgery / Issue 1/2009
Electronic ISSN: 1754-9493
DOI
https://doi.org/10.1186/1754-9493-3-13

Other articles of this Issue 1/2009

Patient Safety in Surgery 1/2009 Go to the issue