Skip to main content
Top
Published in: Journal of Medical Case Reports 1/2012

Open Access 01-12-2012 | Case report

Colovesical fistula causing an uncommon reason for failure of computed tomography colonography: a case report

Published in: Journal of Medical Case Reports | Issue 1/2012

Login to get access

Abstract

Introduction

Computed tomography colonography, or virtual colonoscopy, is a good alternative to optical colonoscopy. However, suboptimal patient preparation or colon distension may reduce the diagnostic accuracy of this imaging technique.

Case presentation

We report the case of an 83-year-old Caucasian woman who presented with a five-month history of pneumaturia and fecaluria and an acute episode of macrohematuria, leading to a high clinical suspicion of a colovesical fistula. The fistula was confirmed by standard contrast-enhanced computed tomography. Optical colonoscopy was performed to exclude the presence of an underlying colonic neoplasm. Since optical colonoscopy was incomplete, computed tomography colonography was performed, but also failed due to inadequate colon distension. The insufflated air directly accumulated within the bladder via the large fistula.

Conclusions

Clinicians should consider colovesical fistula as a potential reason for computed tomography colonography failure.
Appendix
Available only for authorised users
Literature
1.
go back to reference Blachar A, Sosna J: CT colonography (virtual colonoscopy): technique, indications and performance. Digestion. 2007, 76: 34-41. 10.1159/000108392.CrossRefPubMed Blachar A, Sosna J: CT colonography (virtual colonoscopy): technique, indications and performance. Digestion. 2007, 76: 34-41. 10.1159/000108392.CrossRefPubMed
2.
go back to reference Ing A, Lienert A, Frizelle F: Medical image. CT colonography for colovesical fistula. N Z Med J. 2008, 121: 105-108.PubMed Ing A, Lienert A, Frizelle F: Medical image. CT colonography for colovesical fistula. N Z Med J. 2008, 121: 105-108.PubMed
3.
go back to reference Murata A, Miyagi Y, Osoegawa T, Tanaka M, Nakamura K: Detection of retroperitoneal fistula of the colon by CT colonography. Indian J Gastroenterol. 2008, 27: 256-PubMed Murata A, Miyagi Y, Osoegawa T, Tanaka M, Nakamura K: Detection of retroperitoneal fistula of the colon by CT colonography. Indian J Gastroenterol. 2008, 27: 256-PubMed
4.
go back to reference Nadir I, Ozin Y, Kilic ZM, Oguz D, Ulker A, Arda K: Colovesical fistula as a complication of colonic diverticulosis: diagnosis with virtual colonoscopy. Turk J Gastroenterol. 2011, 22: 86-88.CrossRefPubMed Nadir I, Ozin Y, Kilic ZM, Oguz D, Ulker A, Arda K: Colovesical fistula as a complication of colonic diverticulosis: diagnosis with virtual colonoscopy. Turk J Gastroenterol. 2011, 22: 86-88.CrossRefPubMed
5.
go back to reference Javeri K, Williams TR, Bonnett JW: An overview of the method, application, and various findings of computed tomographic colonography in patients after incomplete colonoscopy. Curr Probl Diagn Radiol. 2010, 39: 262-274. 10.1067/j.cpradiol.2009.08.002.CrossRefPubMed Javeri K, Williams TR, Bonnett JW: An overview of the method, application, and various findings of computed tomographic colonography in patients after incomplete colonoscopy. Curr Probl Diagn Radiol. 2010, 39: 262-274. 10.1067/j.cpradiol.2009.08.002.CrossRefPubMed
6.
go back to reference Kim DH, Pickhardt PJ, Taylor AJ, Leung WK, Winter TC, Hinshaw JL, Gopal DV, Reichelderfer M, Hsu RH, Pfau PR: CT colonography versus colonoscopy for the detection of advanced neoplasia. N Engl J Med. 2007, 357: 1403-1412. 10.1056/NEJMoa070543.CrossRefPubMed Kim DH, Pickhardt PJ, Taylor AJ, Leung WK, Winter TC, Hinshaw JL, Gopal DV, Reichelderfer M, Hsu RH, Pfau PR: CT colonography versus colonoscopy for the detection of advanced neoplasia. N Engl J Med. 2007, 357: 1403-1412. 10.1056/NEJMoa070543.CrossRefPubMed
7.
go back to reference Johnson CD, Manduca A, Fletcher JG, MacCarty RL, Carston MJ, Harmsen WS, Mandrekar JN: Noncathartic CT colonography with stool tagging: performance with and without electronic stool subtraction. AJR Am J Roentgenol. 2008, 190: 361-366. 10.2214/AJR.07.2700.CrossRefPubMed Johnson CD, Manduca A, Fletcher JG, MacCarty RL, Carston MJ, Harmsen WS, Mandrekar JN: Noncathartic CT colonography with stool tagging: performance with and without electronic stool subtraction. AJR Am J Roentgenol. 2008, 190: 361-366. 10.2214/AJR.07.2700.CrossRefPubMed
8.
go back to reference Mang T, Maier A, Plank C, Mueller-Mang C, Herold C, Schima W: Pitfalls in multi-detector row CT colonography: a systematic approach. Radiographics. 2007, 27: 431-454. 10.1148/rg.272065081.CrossRefPubMed Mang T, Maier A, Plank C, Mueller-Mang C, Herold C, Schima W: Pitfalls in multi-detector row CT colonography: a systematic approach. Radiographics. 2007, 27: 431-454. 10.1148/rg.272065081.CrossRefPubMed
Metadata
Title
Colovesical fistula causing an uncommon reason for failure of computed tomography colonography: a case report
Publication date
01-12-2012
Published in
Journal of Medical Case Reports / Issue 1/2012
Electronic ISSN: 1752-1947
DOI
https://doi.org/10.1186/1752-1947-6-214

Other articles of this Issue 1/2012

Journal of Medical Case Reports 1/2012 Go to the issue