Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2009

Open Access 01-12-2009 | Technical Note

New fluoroscopic imaging technique for investigation of 6DOF knee kinematics during treadmill gait

Authors: Guoan Li, Michal Kozanek, Ali Hosseini, Fang Liu, Samuel K Van de Velde, Harry E Rubash

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2009

Login to get access

Abstract

Introduction

This report presents a new imaging technique for non-invasive study of six degrees of freedom (DOF) knee kinematics during treadmill gait.

Materials and methods

A treadmill was integrated into a dual fluoroscopic imaging system (DFIS) to formulate a gait analysis system. To demonstrate the application of the system, a healthy subject walked on the treadmill at four different speeds (1.5, 2.0, 2.5 and 3.0 MPH) while the DFIS captured the knee motion during three strides under each speed. Characters of knee joint motion were analyzed in 6DOF during the treadmill walking.

Results

The speed of the knee motion was lower than that of the treadmill. Flexion amplitudes increased with increasing walking speed. Motion patterns in other DOF were not affected by increase in walking speed. The motion character was repeatable under each treadmill speed.

Conclusion

The presented technique can be used to accurately measure the 6DOF knee kinematics at normal walking speeds.
Appendix
Available only for authorised users
Literature
1.
go back to reference Chao EY: Biomechanics of the human gait. Frontiers in Biomechanics. Edited by: Zweifach B. 1986, New York, NY: Springer-Verlag, 225-219.CrossRef Chao EY: Biomechanics of the human gait. Frontiers in Biomechanics. Edited by: Zweifach B. 1986, New York, NY: Springer-Verlag, 225-219.CrossRef
2.
go back to reference Lafortune MA, Cavanagh PR, Sommer HJ, Kalenak A: Three-dimensional kinematics of the human knee during walking. J Biomech. 1992, 25 (4): 347-57. 10.1016/0021-9290(92)90254-X.CrossRefPubMed Lafortune MA, Cavanagh PR, Sommer HJ, Kalenak A: Three-dimensional kinematics of the human knee during walking. J Biomech. 1992, 25 (4): 347-57. 10.1016/0021-9290(92)90254-X.CrossRefPubMed
3.
go back to reference Bach BR, Mikosz RP, Andriacchi TP: The influence of changing femoral attachment positions on force displacement characteristics of the anterior cruciate ligament. Trans ORS. 1988, 13: 129- Bach BR, Mikosz RP, Andriacchi TP: The influence of changing femoral attachment positions on force displacement characteristics of the anterior cruciate ligament. Trans ORS. 1988, 13: 129-
4.
go back to reference Blankevoort L, Huiskes R, de Lange A: The envelope of passive knee joint motion. J Biomech. 1988, 21 (9): 705-20. 10.1016/0021-9290(88)90280-1.CrossRefPubMed Blankevoort L, Huiskes R, de Lange A: The envelope of passive knee joint motion. J Biomech. 1988, 21 (9): 705-20. 10.1016/0021-9290(88)90280-1.CrossRefPubMed
5.
go back to reference Karrholm J: Roentgen stereophotogrammetry. Review of orthopedic applications. Acta Orthop Scand. 1989, 60 (4): 491-503.CrossRefPubMed Karrholm J: Roentgen stereophotogrammetry. Review of orthopedic applications. Acta Orthop Scand. 1989, 60 (4): 491-503.CrossRefPubMed
6.
go back to reference Selvik G: Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. Acta Orthop Scand Suppl. 1989, 232: 1-51.CrossRefPubMed Selvik G: Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. Acta Orthop Scand Suppl. 1989, 232: 1-51.CrossRefPubMed
7.
go back to reference van Dijk R, Huiskes R, Selvik G: Roentgen stereophotogrammetric methods for the evaluation of the three dimensional kinematic behaviour and cruciate ligament length patterns of the human knee joint. J Biomech. 1979, 12 (9): 727-31. 10.1016/0021-9290(79)90021-6.CrossRefPubMed van Dijk R, Huiskes R, Selvik G: Roentgen stereophotogrammetric methods for the evaluation of the three dimensional kinematic behaviour and cruciate ligament length patterns of the human knee joint. J Biomech. 1979, 12 (9): 727-31. 10.1016/0021-9290(79)90021-6.CrossRefPubMed
8.
go back to reference Andriacchi TP, Alexander EJ, Toney MK, Dyrby C, Sum J: A point cluster method for in vivo motion analysis: applied to a study of knee kinematics. J Biomech Eng. 1998, 120 (6): 743-9. 10.1115/1.2834888.CrossRefPubMed Andriacchi TP, Alexander EJ, Toney MK, Dyrby C, Sum J: A point cluster method for in vivo motion analysis: applied to a study of knee kinematics. J Biomech Eng. 1998, 120 (6): 743-9. 10.1115/1.2834888.CrossRefPubMed
9.
go back to reference Li G, Suggs J, Hanson G, Durbhakula S, Johnson T, Freiberg A: Three-dimensional tibiofemoral articular contact kinematics of a cruciate-retaining total knee arthroplasty. J Bone Joint Surg Am. 2006, 88 (2): 395-402. 10.2106/JBJS.D.03028.CrossRefPubMed Li G, Suggs J, Hanson G, Durbhakula S, Johnson T, Freiberg A: Three-dimensional tibiofemoral articular contact kinematics of a cruciate-retaining total knee arthroplasty. J Bone Joint Surg Am. 2006, 88 (2): 395-402. 10.2106/JBJS.D.03028.CrossRefPubMed
10.
go back to reference Banks SA, Hodge WA: Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans Biomed Eng. 1996, 43 (6): 638-49. 10.1109/10.495283.CrossRefPubMed Banks SA, Hodge WA: Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans Biomed Eng. 1996, 43 (6): 638-49. 10.1109/10.495283.CrossRefPubMed
11.
go back to reference Stiehl JB, Komistek RD, Dennis DA, Paxson RD, Hoff WA: Fluoroscopic analysis of kinematics after posterior-cruciate-retaining knee arthroplasty. J Bone Joint Surg Br. 1995, 77 (6): 884-9.PubMed Stiehl JB, Komistek RD, Dennis DA, Paxson RD, Hoff WA: Fluoroscopic analysis of kinematics after posterior-cruciate-retaining knee arthroplasty. J Bone Joint Surg Br. 1995, 77 (6): 884-9.PubMed
12.
go back to reference Li G, Wuerz TH, DeFrate LE: Feasibility of using orthogonal fluoroscopic images to measure in vivo joint kinematics. J Biomech Eng. 2004, 126 (2): 314-8. 10.1115/1.1691448.CrossRefPubMed Li G, Wuerz TH, DeFrate LE: Feasibility of using orthogonal fluoroscopic images to measure in vivo joint kinematics. J Biomech Eng. 2004, 126 (2): 314-8. 10.1115/1.1691448.CrossRefPubMed
13.
go back to reference You BM, Siy P, Anderst W, Tashman S: In vivo measurement of 3-D skeletal kinematics from sequences of biplane radiographs: application to knee kinematics. IEEE Trans Med Imaging. 2001, 20 (6): 514-25. 10.1109/42.929617.CrossRefPubMed You BM, Siy P, Anderst W, Tashman S: In vivo measurement of 3-D skeletal kinematics from sequences of biplane radiographs: application to knee kinematics. IEEE Trans Med Imaging. 2001, 20 (6): 514-25. 10.1109/42.929617.CrossRefPubMed
14.
go back to reference Li G, Velde Van de SK, Bingham JT: Validation of a non-invasive fluoroscopic imaging technique for the measurement of dynamic knee joint motion. J Biomech. 2008, 41 (7): 1616-22. 10.1016/j.jbiomech.2008.01.034.CrossRefPubMed Li G, Velde Van de SK, Bingham JT: Validation of a non-invasive fluoroscopic imaging technique for the measurement of dynamic knee joint motion. J Biomech. 2008, 41 (7): 1616-22. 10.1016/j.jbiomech.2008.01.034.CrossRefPubMed
15.
go back to reference Varadarajan KM, Moynihan AL, D'Lima D, Colwell CW, Li G: In vivo contact kinematics and contact forces of the knee after total knee arthroplasty during dynamic weight-bearing activities. J Biomech. 2008, 41 (10): 2159-68. 10.1016/j.jbiomech.2008.04.021.PubMedCentralCrossRefPubMed Varadarajan KM, Moynihan AL, D'Lima D, Colwell CW, Li G: In vivo contact kinematics and contact forces of the knee after total knee arthroplasty during dynamic weight-bearing activities. J Biomech. 2008, 41 (10): 2159-68. 10.1016/j.jbiomech.2008.04.021.PubMedCentralCrossRefPubMed
16.
go back to reference Defrate LE, Papannagari R, Gill TJ, Moses JM, Pathare NP, Li G: The 6 degrees of freedom kinematics of the knee after anterior cruciate ligament deficiency: an in vivo imaging analysis. Am J Sports Med. 2006, 34 (8): 1240-6. 10.1177/0363546506287299.CrossRefPubMed Defrate LE, Papannagari R, Gill TJ, Moses JM, Pathare NP, Li G: The 6 degrees of freedom kinematics of the knee after anterior cruciate ligament deficiency: an in vivo imaging analysis. Am J Sports Med. 2006, 34 (8): 1240-6. 10.1177/0363546506287299.CrossRefPubMed
17.
go back to reference Zihlmann MS, Gerber H, Stacoff A, Burckhardt K, Szekely G, Stussi E: Three-dimensional kinematics and kinetics of total knee arthroplasty during level walking using single plane video-fluoroscopy and force plates: a pilot study. Gait Posture. 2006, 24 (4): 475-81. 10.1016/j.gaitpost.2005.12.012.CrossRefPubMed Zihlmann MS, Gerber H, Stacoff A, Burckhardt K, Szekely G, Stussi E: Three-dimensional kinematics and kinetics of total knee arthroplasty during level walking using single plane video-fluoroscopy and force plates: a pilot study. Gait Posture. 2006, 24 (4): 475-81. 10.1016/j.gaitpost.2005.12.012.CrossRefPubMed
18.
go back to reference Bohannon RW: Comfortable and maximum walking speed of adults aged 20–79 years: reference values and determinants. Age Ageing. 1997, 26 (1): 15-9. 10.1093/ageing/26.1.15.CrossRefPubMed Bohannon RW: Comfortable and maximum walking speed of adults aged 20–79 years: reference values and determinants. Age Ageing. 1997, 26 (1): 15-9. 10.1093/ageing/26.1.15.CrossRefPubMed
19.
go back to reference Lelas JL, Merriman GJ, Riley PO, Kerrigan DC: Predicting peak kinematic and kinetic parameters from gait speed. Gait Posture. 2003, 17 (2): 106-12. 10.1016/S0966-6362(02)00060-7.CrossRefPubMed Lelas JL, Merriman GJ, Riley PO, Kerrigan DC: Predicting peak kinematic and kinetic parameters from gait speed. Gait Posture. 2003, 17 (2): 106-12. 10.1016/S0966-6362(02)00060-7.CrossRefPubMed
20.
go back to reference Miyoshi T, Shirota T, Yamamoto S, Nakazawa K, Akai M: Effect of the walking speed to the lower limb joint angular displacements, joint moments and ground reaction forces during walking in water. Disabil Rehabil. 2004, 26 (12): 724-32. 10.1080/09638280410001704313.CrossRefPubMed Miyoshi T, Shirota T, Yamamoto S, Nakazawa K, Akai M: Effect of the walking speed to the lower limb joint angular displacements, joint moments and ground reaction forces during walking in water. Disabil Rehabil. 2004, 26 (12): 724-32. 10.1080/09638280410001704313.CrossRefPubMed
21.
go back to reference Andriacchi TP, Ogle JA, Galante JO: Walking speed as a basis for normal and abnormal gait measurements. J Biomech. 1977, 10 (4): 261-8. 10.1016/0021-9290(77)90049-5.CrossRefPubMed Andriacchi TP, Ogle JA, Galante JO: Walking speed as a basis for normal and abnormal gait measurements. J Biomech. 1977, 10 (4): 261-8. 10.1016/0021-9290(77)90049-5.CrossRefPubMed
Metadata
Title
New fluoroscopic imaging technique for investigation of 6DOF knee kinematics during treadmill gait
Authors
Guoan Li
Michal Kozanek
Ali Hosseini
Fang Liu
Samuel K Van de Velde
Harry E Rubash
Publication date
01-12-2009
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2009
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/1749-799X-4-6

Other articles of this Issue 1/2009

Journal of Orthopaedic Surgery and Research 1/2009 Go to the issue