Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2009

Open Access 01-12-2009 | Research article

Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty

Authors: Brad Ellison, Nicholas A Cheney, Keith R Berend, Adolph V Lombardi Jr, Thomas H Mallory

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2009

Login to get access

Abstract

Background

As longevity of cementless femoral components enters the third decade, concerns arise with long-term effects of fixation mode on femoral bone morphology. We examined the long-term consequences on femoral remodeling following total hip arthroplasty with a porous plasma-sprayed tapered titanium stem.

Methods

Clinical data and radiographs were reviewed from a single center for 97 randomly selected cases implanted with the Mallory-Head Porous femoral component during primary total hip arthroplasty. Measurements were taken from preoperative and long-term follow-up radiographs averaging 14 years postoperative. Average changes in the proximal, middle and diaphyseal zones were determined.

Results

On anteroposterior radiographs, the proximal cortical thickness was unchanged medially and the lateral zone increased 1.3%. Middle cortical thickness increased 4.3% medially and 1.2% laterally. Distal cortical thickness increased 9.6% medially and 1.9% laterally. Using the anteroposterior radiographs, canal fill at 100 mm did not correlate with bony changes at any level (Spearman's rank correlation coefficient of -0.18, 0.05, and 0.00; p value = 0.09, 0.67, 0.97). On lateral radiographs, the proximal cortical thickness increased 1.5% medially and 0.98% laterally. Middle cortical thickness increased 2.4% medially and 1.3% laterally. Distal cortical thickness increased 3.5% medially and 2.1% laterally. From lateral radiographs, canal fill at 100 mm correlated with bony hypertrophy at the proximal, mid-level, and distal femur (Spearman's rank correlation coefficient of 0.85, 0.33, and 0.28, respectively; p value = 0.001, 0.016, and 0.01, respectively).

Conclusion

Stress shielding is minimized with the Mallory-Head titanium tapered femoral stem with circumferential proximal plasma-sprayed coating in well-fixed and well-functioning total hip arthroplasty. Additionally, the majority of femora demonstrated increased cortical thickness in all zones around the stem prosthesis. Level of Evidence: Therapeutic Level III.
Appendix
Available only for authorised users
Literature
1.
go back to reference Aldinger PR, Sabo D, Pritsch M, Thomsen M, Mau H, Ewerbeck V, Breusch SJ: Pattern of periprosthetic bone remodeling around stable uncemented tapered stems: a prospective 84-month follow-up study and a median 156-month cross-sectional study with DXA. Calcif Tissue Int. 2003, 73 (2): 115-121. 10.1007/s00223-002-2036-z.CrossRefPubMed Aldinger PR, Sabo D, Pritsch M, Thomsen M, Mau H, Ewerbeck V, Breusch SJ: Pattern of periprosthetic bone remodeling around stable uncemented tapered stems: a prospective 84-month follow-up study and a median 156-month cross-sectional study with DXA. Calcif Tissue Int. 2003, 73 (2): 115-121. 10.1007/s00223-002-2036-z.CrossRefPubMed
2.
go back to reference Crowninshield RD, Maloney WJ, Wentz DH, Levine DL: The role of proximal femoral support in stress development within hip prostheses. Clin Orthop Relat Res. 2004, 420: 176-180. 10.1097/00003086-200403000-00024.CrossRefPubMed Crowninshield RD, Maloney WJ, Wentz DH, Levine DL: The role of proximal femoral support in stress development within hip prostheses. Clin Orthop Relat Res. 2004, 420: 176-180. 10.1097/00003086-200403000-00024.CrossRefPubMed
3.
go back to reference Emerson RH: Proximal ingrowth components. Clin Orthop Relat Res. 2004, 420: 130-134. 10.1097/00003086-200403000-00018.CrossRefPubMed Emerson RH: Proximal ingrowth components. Clin Orthop Relat Res. 2004, 420: 130-134. 10.1097/00003086-200403000-00018.CrossRefPubMed
4.
go back to reference Engh CA, Massin P, Suthers KE: Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res. 1990, 257: 107-128.PubMed Engh CA, Massin P, Suthers KE: Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res. 1990, 257: 107-128.PubMed
5.
go back to reference Engh CA, O'Connor D, Jasty M, McGovern TF, Bobyn JD, Harris WH: Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses. Clin Orthop Relat Res. 1992, 285: 13-29.PubMed Engh CA, O'Connor D, Jasty M, McGovern TF, Bobyn JD, Harris WH: Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses. Clin Orthop Relat Res. 1992, 285: 13-29.PubMed
6.
go back to reference Rubash HE, Sinha RK, Shanbhag AS, Kim SY: Pathogenesis of bone loss after total hip arthroplasty. Orthop Clin North Am. 1998, 29 (2): 173-186. 10.1016/S0030-5898(05)70316-3.CrossRefPubMed Rubash HE, Sinha RK, Shanbhag AS, Kim SY: Pathogenesis of bone loss after total hip arthroplasty. Orthop Clin North Am. 1998, 29 (2): 173-186. 10.1016/S0030-5898(05)70316-3.CrossRefPubMed
7.
go back to reference Engh CA, Young AM, Engh CA, Hopper RH: Clinical consequences of stress shielding after porous-coated total hip arthroplasty. Clin Orthop Relat Res. 2003, 417: 157-163.PubMed Engh CA, Young AM, Engh CA, Hopper RH: Clinical consequences of stress shielding after porous-coated total hip arthroplasty. Clin Orthop Relat Res. 2003, 417: 157-163.PubMed
8.
go back to reference Head WC, Bauk DJ, Emerson RH: Titanium as the material of choice for cementless femoral components in total hip arthroplasty. Clin Orthop Relat Res. 1995, 311: 85-90.PubMed Head WC, Bauk DJ, Emerson RH: Titanium as the material of choice for cementless femoral components in total hip arthroplasty. Clin Orthop Relat Res. 1995, 311: 85-90.PubMed
9.
go back to reference Hofmann AA, Feign ME, Klauser W, VanGorp CC, Camargo MP: Cementless primary total hip arthroplasty with a tapered, proximally, porous-coated titanium prosthesis. A 4- to 8-year retrospective review. J Arthroplasty. 2000, 15: 833-839. 10.1054/arth.2000.9318.CrossRefPubMed Hofmann AA, Feign ME, Klauser W, VanGorp CC, Camargo MP: Cementless primary total hip arthroplasty with a tapered, proximally, porous-coated titanium prosthesis. A 4- to 8-year retrospective review. J Arthroplasty. 2000, 15: 833-839. 10.1054/arth.2000.9318.CrossRefPubMed
10.
go back to reference Bourne RB, Rorabeck CH, Ghazal ME, Lee MH: Pain in the thigh following total hip replacement with a porous-coated anatomic prosthesis for osteoarthrosis. A five-year follow-up study. J Bone Joint Surg Am. 1994, 76 (10): 1464-1470.PubMed Bourne RB, Rorabeck CH, Ghazal ME, Lee MH: Pain in the thigh following total hip replacement with a porous-coated anatomic prosthesis for osteoarthrosis. A five-year follow-up study. J Bone Joint Surg Am. 1994, 76 (10): 1464-1470.PubMed
11.
go back to reference Engh CA, Claus AM, Hopper RH, Engh CA: Long-term results using the anatomic medullary locking hip prosthesis. Clin Orthop Relat Res. 2001, 393: 137-146. 10.1097/00003086-200112000-00016.CrossRefPubMed Engh CA, Claus AM, Hopper RH, Engh CA: Long-term results using the anatomic medullary locking hip prosthesis. Clin Orthop Relat Res. 2001, 393: 137-146. 10.1097/00003086-200112000-00016.CrossRefPubMed
12.
go back to reference Götze C, Tschungunow A, Götze HG, Böttner F, Pötzl W, Gosheger G: Long-term results of the metal-cancellous Lübeck total hip arthroplasty: a critical review at 12.8 years. Arch Orthop Trauma Surg. 2006, 126 (1): 28-35. 10.1007/s00402-005-0064-7.CrossRefPubMed Götze C, Tschungunow A, Götze HG, Böttner F, Pötzl W, Gosheger G: Long-term results of the metal-cancellous Lübeck total hip arthroplasty: a critical review at 12.8 years. Arch Orthop Trauma Surg. 2006, 126 (1): 28-35. 10.1007/s00402-005-0064-7.CrossRefPubMed
13.
go back to reference Hallan G, Lie SA, Havelin LI: High wear rates and extensive osteolysis in 3 types of uncemented total hip arthroplasty: a review of the PCA, the Harris Galante and the Profile/Tri-Lock Plus arthroplasties with a minimum of 12 years median follow-up in 96 hips. Acta Orthop. 2006, 77 (4): 575-584. 10.1080/17453670610012638.CrossRefPubMed Hallan G, Lie SA, Havelin LI: High wear rates and extensive osteolysis in 3 types of uncemented total hip arthroplasty: a review of the PCA, the Harris Galante and the Profile/Tri-Lock Plus arthroplasties with a minimum of 12 years median follow-up in 96 hips. Acta Orthop. 2006, 77 (4): 575-584. 10.1080/17453670610012638.CrossRefPubMed
14.
go back to reference Gruen TA, McNiece GM, Amstutz HC: "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979, 141: 17-27.PubMed Gruen TA, McNiece GM, Amstutz HC: "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979, 141: 17-27.PubMed
15.
go back to reference Frndak PA, Mallory TH, Lombardi AV: Translateral surgical approach to the hip. The abductor muscle "split". Clin Orthop Relat Res. 1993, 295: 135-141.PubMed Frndak PA, Mallory TH, Lombardi AV: Translateral surgical approach to the hip. The abductor muscle "split". Clin Orthop Relat Res. 1993, 295: 135-141.PubMed
16.
go back to reference Berend KR, Lombardi AV, Mallory TH, Dodds KL, Adams JB: Cementless double-tapered arthroplasty in patients 75 years of age and older. J Arthroplasty. 2004, 19 (3): 288-295. 10.1016/j.arth.2003.11.002.CrossRefPubMed Berend KR, Lombardi AV, Mallory TH, Dodds KL, Adams JB: Cementless double-tapered arthroplasty in patients 75 years of age and older. J Arthroplasty. 2004, 19 (3): 288-295. 10.1016/j.arth.2003.11.002.CrossRefPubMed
17.
go back to reference Berend KR, Lombardi AV, Mallory TH, Dodds KL, Adams JB: Cerclage wires or cables for the management of intraoperative fracture associated with a cementless tapered femoral prosthesis: Results at 2-16 years. J Arthroplasty. 2004, 19 (7 Suppl 2): 17-21. 10.1016/j.arth.2004.06.008.CrossRefPubMed Berend KR, Lombardi AV, Mallory TH, Dodds KL, Adams JB: Cerclage wires or cables for the management of intraoperative fracture associated with a cementless tapered femoral prosthesis: Results at 2-16 years. J Arthroplasty. 2004, 19 (7 Suppl 2): 17-21. 10.1016/j.arth.2004.06.008.CrossRefPubMed
18.
go back to reference Berend KR, Mallory TH, Lombardi AV, Dodds KL, Adams JB: Tapered cementless femoral stem: difficult to place in varus but performs well in those rare cases. Orthopedics. 2007, 30 (4): 295-297.PubMed Berend KR, Mallory TH, Lombardi AV, Dodds KL, Adams JB: Tapered cementless femoral stem: difficult to place in varus but performs well in those rare cases. Orthopedics. 2007, 30 (4): 295-297.PubMed
19.
go back to reference Ellison B, Berend KR, Lombardi AV, Mallory TH: Tapered titanium porous plasma-sprayed femoral component in patients aged 40 years and younger. J Arthroplasty. 2006, 21 (6 Suppl 2): 32-37. 10.1016/j.arth.2006.03.008.CrossRefPubMed Ellison B, Berend KR, Lombardi AV, Mallory TH: Tapered titanium porous plasma-sprayed femoral component in patients aged 40 years and younger. J Arthroplasty. 2006, 21 (6 Suppl 2): 32-37. 10.1016/j.arth.2006.03.008.CrossRefPubMed
20.
go back to reference Lombardi AV, Berend KR, Mallory TH: Hydroxyapatite-coated titanium porous plasma spray tapered stem: Experience at 15-18 years. Clin Orthop Relat Res. 2006, 453: 81-85. 10.1097/01.blo.0000238872.01767.09.CrossRefPubMed Lombardi AV, Berend KR, Mallory TH: Hydroxyapatite-coated titanium porous plasma spray tapered stem: Experience at 15-18 years. Clin Orthop Relat Res. 2006, 453: 81-85. 10.1097/01.blo.0000238872.01767.09.CrossRefPubMed
21.
go back to reference Mallory TH, Lombardi AV, Leith JR, Fujita H, Hartman JF, Capps SG, Kefauver CA, Adams JB, Vorys GC: Minimal 10-year results of a tapered cementless femoral component in total hip arthroplasty. J Arthroplasty. 2001, 16 (8 suppl 1): 49-54. 10.1054/arth.2001.28721.CrossRefPubMed Mallory TH, Lombardi AV, Leith JR, Fujita H, Hartman JF, Capps SG, Kefauver CA, Adams JB, Vorys GC: Minimal 10-year results of a tapered cementless femoral component in total hip arthroplasty. J Arthroplasty. 2001, 16 (8 suppl 1): 49-54. 10.1054/arth.2001.28721.CrossRefPubMed
22.
go back to reference Bourne RB, Rorabeck CH: Porous coated femoral fixation: the long and short of it!. Orthopedics. 2003, 26 (9): 911-912.PubMed Bourne RB, Rorabeck CH: Porous coated femoral fixation: the long and short of it!. Orthopedics. 2003, 26 (9): 911-912.PubMed
23.
go back to reference Gillies RM, Morberg PH, Bruce WJ, Turnbull A, Walsh WR: The influence of design parameters on cortical strain distribution of a cementless titanium femoral stem. Med Eng Phys. 2002, 24 (2): 109-114. 10.1016/S1350-4533(01)00124-2.CrossRefPubMed Gillies RM, Morberg PH, Bruce WJ, Turnbull A, Walsh WR: The influence of design parameters on cortical strain distribution of a cementless titanium femoral stem. Med Eng Phys. 2002, 24 (2): 109-114. 10.1016/S1350-4533(01)00124-2.CrossRefPubMed
24.
go back to reference Gosens T, Sluimer JC, Kester AD, van Langlaan EJ: Femoral fit predicts radiologica changes, but not clinical results in Mallory-Head total hip arthroplasties. Clin Orthop Relat Res. 2005, 432: 138-147. 10.1097/01.blo.0000149813.32857.c2.CrossRefPubMed Gosens T, Sluimer JC, Kester AD, van Langlaan EJ: Femoral fit predicts radiologica changes, but not clinical results in Mallory-Head total hip arthroplasties. Clin Orthop Relat Res. 2005, 432: 138-147. 10.1097/01.blo.0000149813.32857.c2.CrossRefPubMed
25.
go back to reference Head WC, Mallory TH, Emerson RH: The proximal porous coating alternative for primary total hip arthroplasty. Orthopedics. 1999, 22 (9): 813-815.PubMed Head WC, Mallory TH, Emerson RH: The proximal porous coating alternative for primary total hip arthroplasty. Orthopedics. 1999, 22 (9): 813-815.PubMed
26.
go back to reference Hozack WJ, Rothman RH, Eng K, Mesa J: Primary cementless hip arthroplasty with a titanium plasma sprayed prosthesis. Clin Orthop Relat Res. 1996, 333: 217-225. 10.1097/00003086-199612000-00023.CrossRefPubMed Hozack WJ, Rothman RH, Eng K, Mesa J: Primary cementless hip arthroplasty with a titanium plasma sprayed prosthesis. Clin Orthop Relat Res. 1996, 333: 217-225. 10.1097/00003086-199612000-00023.CrossRefPubMed
27.
go back to reference Mallory TH, Head WC, Lombardi AV: Tapered design for the cementless total hip arthroplasty femoral component. Clin Orthop Relat Res. 1997, 344: 172-178. 10.1097/00003086-199711000-00018.CrossRefPubMed Mallory TH, Head WC, Lombardi AV: Tapered design for the cementless total hip arthroplasty femoral component. Clin Orthop Relat Res. 1997, 344: 172-178. 10.1097/00003086-199711000-00018.CrossRefPubMed
28.
go back to reference Emerson RH, Sanders SB, Head WC, Higgins L: Effect of circumferential plasma-spray porous coating on the rate of femoral osteolysis after total hip arthroplasty. J Bone Joint Surg Am. 1999, 81 (9): 1291-1298.PubMed Emerson RH, Sanders SB, Head WC, Higgins L: Effect of circumferential plasma-spray porous coating on the rate of femoral osteolysis after total hip arthroplasty. J Bone Joint Surg Am. 1999, 81 (9): 1291-1298.PubMed
29.
go back to reference Bourne RB, Rorabeck CH, Patterson JJ, Guerin J: Tapered titanium cementless total hip replacements: a 10- to 13-year followup study. Clin Orthop Relat Res. 2001, 303: 112-120. 10.1097/00003086-200112000-00013.CrossRef Bourne RB, Rorabeck CH, Patterson JJ, Guerin J: Tapered titanium cementless total hip replacements: a 10- to 13-year followup study. Clin Orthop Relat Res. 2001, 303: 112-120. 10.1097/00003086-200112000-00013.CrossRef
30.
go back to reference Emerson RH, Head WC, Emerson CB, Rosenfeldt W, Higgins LL: A comparison of cemented and uncemented titanium femoral components used for primary total hip arthroplasty: a radiographic and survivorship study. J Arthroplasty. 2002, 17 (5): 584-591. 10.1054/arth.2002.32696.CrossRefPubMed Emerson RH, Head WC, Emerson CB, Rosenfeldt W, Higgins LL: A comparison of cemented and uncemented titanium femoral components used for primary total hip arthroplasty: a radiographic and survivorship study. J Arthroplasty. 2002, 17 (5): 584-591. 10.1054/arth.2002.32696.CrossRefPubMed
31.
go back to reference Gosens T, van Langelaan EJ, Tonino AJ: Cementless Mallory-Head HA-coated hip arthroplasty for osteoarthritis in hip dysplasia. J Arthroplasty. 2003, 18 (4): 401-410. 10.1016/S0883-5403(03)00063-9.CrossRefPubMed Gosens T, van Langelaan EJ, Tonino AJ: Cementless Mallory-Head HA-coated hip arthroplasty for osteoarthritis in hip dysplasia. J Arthroplasty. 2003, 18 (4): 401-410. 10.1016/S0883-5403(03)00063-9.CrossRefPubMed
32.
go back to reference Park MS, Choi BW, Kim SJ, Park JH: Plasma spray-coated Ti femoral component for cementless total hip arthroplasty. J Arthroplasty. 2003, 18 (5): 626-630. 10.1016/S0883-5403(03)00203-1.CrossRefPubMed Park MS, Choi BW, Kim SJ, Park JH: Plasma spray-coated Ti femoral component for cementless total hip arthroplasty. J Arthroplasty. 2003, 18 (5): 626-630. 10.1016/S0883-5403(03)00203-1.CrossRefPubMed
33.
go back to reference Reitman RD, Emerson R, Higgins L, Head W: Thirteen year results of total hip arthroplasty using a tapered titanium femoral component inserted without cement in patients with type C bone. J Arthroplasty. 2003, 18 (7 Suppl 1): 116-121. 10.1016/S0883-5403(03)00344-9.CrossRefPubMed Reitman RD, Emerson R, Higgins L, Head W: Thirteen year results of total hip arthroplasty using a tapered titanium femoral component inserted without cement in patients with type C bone. J Arthroplasty. 2003, 18 (7 Suppl 1): 116-121. 10.1016/S0883-5403(03)00344-9.CrossRefPubMed
34.
go back to reference Berry DJ, Collins DC, Harmsen W, Xenos JS, Callaghan JJ, Engh CA, Engh CA: How does prosthesis fixation type alter long-term femoral cortical bone remodeling around THA?. Presented as Poster 005 at the American Academy of Orthopedic Surgeons. 2005, Annual Meeting, Washington, DC, February 23-27, 2005 Berry DJ, Collins DC, Harmsen W, Xenos JS, Callaghan JJ, Engh CA, Engh CA: How does prosthesis fixation type alter long-term femoral cortical bone remodeling around THA?. Presented as Poster 005 at the American Academy of Orthopedic Surgeons. 2005, Annual Meeting, Washington, DC, February 23-27, 2005
35.
go back to reference Engh CA, McGovern TF, Bobyn JD, Harris WH: A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty. J Bone Joint Surg Am. 1992, 74 (7): 1009-1020.PubMed Engh CA, McGovern TF, Bobyn JD, Harris WH: A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty. J Bone Joint Surg Am. 1992, 74 (7): 1009-1020.PubMed
36.
go back to reference Gibbons CE, Davies AJ, Amis AA, Olearnik H, Parker BC, Scott JE: Periprosthetic bone mineral density changes with femoral components of differing design philosophy. Int Orthop. 2001, 25 (2): 89-92. 10.1007/s002640100246.PubMedCentralCrossRefPubMed Gibbons CE, Davies AJ, Amis AA, Olearnik H, Parker BC, Scott JE: Periprosthetic bone mineral density changes with femoral components of differing design philosophy. Int Orthop. 2001, 25 (2): 89-92. 10.1007/s002640100246.PubMedCentralCrossRefPubMed
37.
go back to reference Grant P, Aamodt A, Falch JA, Nordsletten L: Differences in stability and bone remodeling between a customized uncemented hydroxyapatite coated and a standard cemented femoral stem. A randomized study with use of radiostereometry and bone densitometry. J Orthop Res. 2005, 23 (6): 1280-1285.PubMed Grant P, Aamodt A, Falch JA, Nordsletten L: Differences in stability and bone remodeling between a customized uncemented hydroxyapatite coated and a standard cemented femoral stem. A randomized study with use of radiostereometry and bone densitometry. J Orthop Res. 2005, 23 (6): 1280-1285.PubMed
38.
go back to reference Kiratli BJ, Checovich MM, McBeath AA, Wilson MA, Heiner JP: Measurement of bone mineral density by dual-energy x-ray absorptiometry in patients with the Wisconsin hip, an uncemented femoral stem. J Arthroplasty. 1996, 11 (2): 184-193. 10.1016/S0883-5403(05)80015-4.CrossRefPubMed Kiratli BJ, Checovich MM, McBeath AA, Wilson MA, Heiner JP: Measurement of bone mineral density by dual-energy x-ray absorptiometry in patients with the Wisconsin hip, an uncemented femoral stem. J Arthroplasty. 1996, 11 (2): 184-193. 10.1016/S0883-5403(05)80015-4.CrossRefPubMed
39.
go back to reference Kiratli BJ, Heiner JP, McBeath AA, Wilson MA: Determination of bone mineral density by dual x-ray absorptiometry in patients with uncemented total hip arthroplasty. J Orthop Res. 1992, 10 (6): 836-844. 10.1002/jor.1100100613.CrossRefPubMed Kiratli BJ, Heiner JP, McBeath AA, Wilson MA: Determination of bone mineral density by dual x-ray absorptiometry in patients with uncemented total hip arthroplasty. J Orthop Res. 1992, 10 (6): 836-844. 10.1002/jor.1100100613.CrossRefPubMed
40.
go back to reference Kröger H, Venesmaa P, Jurvelin J, Miettinen H, Suomalainen O, Alhava E: Bone density at the proximal femur after total hip arthroplasty. Clin Orthop Relat Res. 1998, 352: 66-74.PubMed Kröger H, Venesmaa P, Jurvelin J, Miettinen H, Suomalainen O, Alhava E: Bone density at the proximal femur after total hip arthroplasty. Clin Orthop Relat Res. 1998, 352: 66-74.PubMed
41.
go back to reference Wixson RL, Stulberg SD, Van Flandern GJ, Puri L: Maintenance of proximal bone mass with an uncemented femoral stem analysis with dual-energy-xray-absorptiometry. J Arthroplasty. 1997, 12 (4): 365-372. 10.1016/S0883-5403(97)90191-1.CrossRefPubMed Wixson RL, Stulberg SD, Van Flandern GJ, Puri L: Maintenance of proximal bone mass with an uncemented femoral stem analysis with dual-energy-xray-absorptiometry. J Arthroplasty. 1997, 12 (4): 365-372. 10.1016/S0883-5403(97)90191-1.CrossRefPubMed
42.
go back to reference Lengsfeld M, Burchard R, Günther D, Pressel T, Schmitt J, Leppek R, Griss P: Femoral strain changes after total hip arthroplasty - patient-specific finite element analysis 12 years after operation. Med Eng Phys. 2005, 27 (8): 649-654. 10.1016/j.medengphy.2004.12.016.CrossRefPubMed Lengsfeld M, Burchard R, Günther D, Pressel T, Schmitt J, Leppek R, Griss P: Femoral strain changes after total hip arthroplasty - patient-specific finite element analysis 12 years after operation. Med Eng Phys. 2005, 27 (8): 649-654. 10.1016/j.medengphy.2004.12.016.CrossRefPubMed
43.
go back to reference Lengsfeld M, Günther D, Pressel T, Leppek R, Schmitt J, Griss P: Validation data for periprosthetic bone remodeling theories. J Biomech. 2002, 35 (12): 1553-1564. 10.1016/S0021-9290(02)00187-2.CrossRefPubMed Lengsfeld M, Günther D, Pressel T, Leppek R, Schmitt J, Griss P: Validation data for periprosthetic bone remodeling theories. J Biomech. 2002, 35 (12): 1553-1564. 10.1016/S0021-9290(02)00187-2.CrossRefPubMed
44.
go back to reference Schmidt R, Mueller L, Nowak TE, Pitto RP: Clinical outcome and periprosthetic bone remodeling of an uncemented femoral component with taper design. Int Orthop. 2003, 27 (4): 204-207. 10.1007/s00264-003-0455-8.PubMedCentralCrossRefPubMed Schmidt R, Mueller L, Nowak TE, Pitto RP: Clinical outcome and periprosthetic bone remodeling of an uncemented femoral component with taper design. Int Orthop. 2003, 27 (4): 204-207. 10.1007/s00264-003-0455-8.PubMedCentralCrossRefPubMed
45.
go back to reference Maloney WJ, Sychterz C, Bragdon C, McGovern T, Jasty M, Engh CA, Harris WH: The Otto Aufranc Award. Skeletal response to well fixed femoral components inserted with and without cement. Clin Orthop Relat Res. 1996, 333: 15-26. 10.1097/00003086-199612000-00003.CrossRefPubMed Maloney WJ, Sychterz C, Bragdon C, McGovern T, Jasty M, Engh CA, Harris WH: The Otto Aufranc Award. Skeletal response to well fixed femoral components inserted with and without cement. Clin Orthop Relat Res. 1996, 333: 15-26. 10.1097/00003086-199612000-00003.CrossRefPubMed
Metadata
Title
Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty
Authors
Brad Ellison
Nicholas A Cheney
Keith R Berend
Adolph V Lombardi Jr
Thomas H Mallory
Publication date
01-12-2009
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2009
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/1749-799X-4-42

Other articles of this Issue 1/2009

Journal of Orthopaedic Surgery and Research 1/2009 Go to the issue