Skip to main content
Top
Published in: Radiation Oncology 1/2012

Open Access 01-12-2012 | Research

Image-Guided Robotic Stereotactic Radiation Therapy with Fiducial-Free Tumor Tracking for Lung Cancer

Authors: Jean-Emmanuel Bibault, Bernard Prevost, Eric Dansin, Xavier Mirabel, Thomas Lacornerie, Eric Lartigau

Published in: Radiation Oncology | Issue 1/2012

Login to get access

Abstract

Purpose

Stereotactic body radiation therapy (SBRT) for early-stage lung cancer can be achieved with several methods: respiratory gating, body frame, or real-time target and motion tracking. Two target tracking methods are currently available with the CyberKnife® System: the first one, fiducial tracking, requires the use of radio-opaque markers implanted near or inside the tumor, while the other, Xsight® Lung Tracking System, (XLTS) is fiducial-free. With XLTS, targeting is synchronized directly with target motion, which occurs due to respiration. While the former method (fiducial tracking) is well documented, the clinical relevance of the latter (tracking without fiducials) has never been well described to this date.

Patients and Methods

A study was performed at our department for each patient treated for lung cancer with CyberKnife using XLTS. Selection criteria were: primary or recurring T1 or T2 stage non-small-cell lung cancer (NSCLC) with 15–60 mm tumor size. Initial staging included CT-Scan and FDG-PET.

Results

Fifty-one patients not amenable to surgery were treated with XLTS. Median follow-up was 15 months (range, 5–30 months). Median tumor size was 24 mm (range, 15–60 mm). Median total dose was 60 Gy (36–60 Gy) in three fractions. Actuarial overall survival was 85.5% (95% CI = 74.5–96%) at 1 year and 79.4% (95% CI = 64–94.8%) at 2 years. Actuarial local control rate was 92% (95% CI = 84–99%) at one1 year and 86% (95% CI = 75–97%) at 2 years.

Conclusion

Local control and overall survival rates were similar to previous reports that used fiducials for tumor tracking. Toxicity was lower than most studies since tumor tracking did not require fiducial implantion. This fiducial-free method for respiratory motion tracking is a valid option for the most fragile patients.
Appendix
Available only for authorised users
Literature
1.
go back to reference Whyte RI, Crownover R, Murphy MJ, et al.: Stereotactic radiosurgery for lung tumors: preliminary report of a phase I trial. Ann Thor Surg. 2003, 75: 1097. 10.1016/S0003-4975(02)04681-7CrossRef Whyte RI, Crownover R, Murphy MJ, et al.: Stereotactic radiosurgery for lung tumors: preliminary report of a phase I trial. Ann Thor Surg. 2003, 75: 1097. 10.1016/S0003-4975(02)04681-7CrossRef
2.
go back to reference Geraghty PR, Kee ST, McFarlane G, et al.: CT-guided Transthoracic Needle Aspiration Biopsy of Pulmonary Nodules: Needle Size and Pneumothorax Rate. Radiology. 2003, 229: 475-481. 10.1148/radiol.2291020499CrossRefPubMed Geraghty PR, Kee ST, McFarlane G, et al.: CT-guided Transthoracic Needle Aspiration Biopsy of Pulmonary Nodules: Needle Size and Pneumothorax Rate. Radiology. 2003, 229: 475-481. 10.1148/radiol.2291020499CrossRefPubMed
3.
go back to reference Saji H, Nakamura H, Tsuchida T, et al.: The Incidence and the Risk of Pneumothorax and Chest Tube Placement After Percutaneous CT-Guided Lung Biopsy. Chest. 2002, 121: 1521-1526. 10.1378/chest.121.5.1521CrossRefPubMed Saji H, Nakamura H, Tsuchida T, et al.: The Incidence and the Risk of Pneumothorax and Chest Tube Placement After Percutaneous CT-Guided Lung Biopsy. Chest. 2002, 121: 1521-1526. 10.1378/chest.121.5.1521CrossRefPubMed
4.
go back to reference Reichner CA, Collins BT, Gagnon GJ, et al.: The placement of gold fiducials for CyberKnife stereotactic radiosurgery using a modified transbronchial needle aspiration technique. J Bronchol. 2005, 12: 193. 10.1097/01.lab.0000186345.85025.41CrossRef Reichner CA, Collins BT, Gagnon GJ, et al.: The placement of gold fiducials for CyberKnife stereotactic radiosurgery using a modified transbronchial needle aspiration technique. J Bronchol. 2005, 12: 193. 10.1097/01.lab.0000186345.85025.41CrossRef
5.
go back to reference Yeow KM, Su I, et al.: Risk Factors of Pneumothorax and Bleeding. Chest 2004, 126: 748. 10.1378/chest.126.3.748CrossRefPubMed Yeow KM, Su I, et al.: Risk Factors of Pneumothorax and Bleeding. Chest 2004, 126: 748. 10.1378/chest.126.3.748CrossRefPubMed
6.
go back to reference Fu D, Kahn R, Wang B, et al.: Fiducial-free Lung Tumor Tracking for CyberKnife Radiosurgery. Int J Radiat Oncol Biol Phys. 2008, 72: S608-S609.CrossRef Fu D, Kahn R, Wang B, et al.: Fiducial-free Lung Tumor Tracking for CyberKnife Radiosurgery. Int J Radiat Oncol Biol Phys. 2008, 72: S608-S609.CrossRef
7.
go back to reference Fu D, Kuduvalli G: Enhancing skeletal features in digitally reconstructed radiographs. Image Processing.Vol 6144, San Diego, CA, USA; 2006. Fu D, Kuduvalli G: Enhancing skeletal features in digitally reconstructed radiographs. Image Processing.Vol 6144, San Diego, CA, USA; 2006.
8.
go back to reference Sayeh S, Wang J, Main W, Kilby W, Maurer C: Respiratory Motion Tracking for Robotic Radiosurgery. Dans: Treating Tumors that Move with Respiration. Springer. Urschel, Harold C 2007, 15: 15-29. Sayeh S, Wang J, Main W, Kilby W, Maurer C: Respiratory Motion Tracking for Robotic Radiosurgery. Dans: Treating Tumors that Move with Respiration. Springer. Urschel, Harold C 2007, 15: 15-29.
9.
go back to reference Schweikard A, Glosser G, Bodduluri M, Murphy MJ, Adler JR: Robotic motion compensation for respiratory movement during radiosurgery. Comput Aided Surg. 2000, 5: 263-277. 10.3109/10929080009148894CrossRefPubMed Schweikard A, Glosser G, Bodduluri M, Murphy MJ, Adler JR: Robotic motion compensation for respiratory movement during radiosurgery. Comput Aided Surg. 2000, 5: 263-277. 10.3109/10929080009148894CrossRefPubMed
10.
go back to reference Schweikard A, Shiomi H, Adler J: Respiration tracking in radiosurgery. Med Phys. 2004, 31: 2738. 10.1118/1.1774132CrossRefPubMed Schweikard A, Shiomi H, Adler J: Respiration tracking in radiosurgery. Med Phys. 2004, 31: 2738. 10.1118/1.1774132CrossRefPubMed
11.
go back to reference Therasse P, Arbuck SG, Eisenhauer EA, et al.: New guidelines to evaluate the response to treatment in solid tumors. European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada. J. Natl. Cancer Inst. 2000, 92: 205-216. 10.1093/jnci/92.3.205CrossRefPubMed Therasse P, Arbuck SG, Eisenhauer EA, et al.: New guidelines to evaluate the response to treatment in solid tumors. European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada. J. Natl. Cancer Inst. 2000, 92: 205-216. 10.1093/jnci/92.3.205CrossRefPubMed
12.
go back to reference Nuyttens JJ, Prévost J-B, Praag J, et al.: Lung tumor tracking during stereotactic radiotherapy treatment with the CyberKnife: Marker placement and early results. Acta Oncol. 2006, 45: 961-965. 10.1080/02841860600902205CrossRefPubMed Nuyttens JJ, Prévost J-B, Praag J, et al.: Lung tumor tracking during stereotactic radiotherapy treatment with the CyberKnife: Marker placement and early results. Acta Oncol. 2006, 45: 961-965. 10.1080/02841860600902205CrossRefPubMed
13.
go back to reference Collins B, Erickson K, Reichner C, et al.: Radical stereotactic radiosurgery with real-time tumor motion tracking in the treatment of small peripheral lung tumors. Radiat Oncol. 2007, 2: 39. 10.1186/1748-717X-2-39PubMedCentralCrossRefPubMed Collins B, Erickson K, Reichner C, et al.: Radical stereotactic radiosurgery with real-time tumor motion tracking in the treatment of small peripheral lung tumors. Radiat Oncol. 2007, 2: 39. 10.1186/1748-717X-2-39PubMedCentralCrossRefPubMed
14.
go back to reference Castelli J, Thariat J, Benezery K, et al.: Analyse de la toxicité précoce des traitements par Cyberknife® des cancers pulmonaires et résultats préliminaires. Cancer Radiother. 2008, 12: 793-799. 10.1016/j.canrad.2008.06.002CrossRefPubMed Castelli J, Thariat J, Benezery K, et al.: Analyse de la toxicité précoce des traitements par Cyberknife® des cancers pulmonaires et résultats préliminaires. Cancer Radiother. 2008, 12: 793-799. 10.1016/j.canrad.2008.06.002CrossRefPubMed
15.
go back to reference van Zyp NC Van der Voort, Prévost JB, Hoogeman MS, et al.: Stereotactic radiotherapy with real-time tumor tracking for non-small cell lung cancer: Clinical outcome. Radiother Oncol 2009, 91: 296-300. 10.1016/j.radonc.2009.02.011CrossRef van Zyp NC Van der Voort, Prévost JB, Hoogeman MS, et al.: Stereotactic radiotherapy with real-time tumor tracking for non-small cell lung cancer: Clinical outcome. Radiother Oncol 2009, 91: 296-300. 10.1016/j.radonc.2009.02.011CrossRef
16.
go back to reference Herder GJ, Van Tinteren H, Colding RP, et al.: Clinical prediction model to characterize pulmonary nodules: Validation and added value of 18 F-fluorodeoxyglucose positron emission tomography. Chest. 2005, 128: 2490-2496. 10.1378/chest.128.4.2490CrossRefPubMed Herder GJ, Van Tinteren H, Colding RP, et al.: Clinical prediction model to characterize pulmonary nodules: Validation and added value of 18 F-fluorodeoxyglucose positron emission tomography. Chest. 2005, 128: 2490-2496. 10.1378/chest.128.4.2490CrossRefPubMed
17.
go back to reference Aoki T, Nagata Y, Negoro Y, et al.: Evaluation of Lung Injury after Three-dimensional Conformal Stereotactic Radiation Therapy for Solitary Lung Tumors: CT Appearance. Radiology. 2004, 230: 101-108. 10.1148/radiol.2301021226CrossRefPubMed Aoki T, Nagata Y, Negoro Y, et al.: Evaluation of Lung Injury after Three-dimensional Conformal Stereotactic Radiation Therapy for Solitary Lung Tumors: CT Appearance. Radiology. 2004, 230: 101-108. 10.1148/radiol.2301021226CrossRefPubMed
18.
go back to reference Mehta V: Radiation pneumonitis and pulmonary fibrosis in non–small-cell lung cancer: Pulmonary function, prediction, and prevention. Int J Radiat Oncol Biol Phys. 2005, 63: 5-24. 10.1016/j.ijrobp.2005.03.047CrossRefPubMed Mehta V: Radiation pneumonitis and pulmonary fibrosis in non–small-cell lung cancer: Pulmonary function, prediction, and prevention. Int J Radiat Oncol Biol Phys. 2005, 63: 5-24. 10.1016/j.ijrobp.2005.03.047CrossRefPubMed
19.
go back to reference Takeda T, Takeda A, Kunieda E, et al.: Radiation injury after hypofractionated stereotactic radiotherapy for peripheral small lung tumors: serial changes on CT. Am J Roentgenol. 2004, 182: 1123.CrossRef Takeda T, Takeda A, Kunieda E, et al.: Radiation injury after hypofractionated stereotactic radiotherapy for peripheral small lung tumors: serial changes on CT. Am J Roentgenol. 2004, 182: 1123.CrossRef
Metadata
Title
Image-Guided Robotic Stereotactic Radiation Therapy with Fiducial-Free Tumor Tracking for Lung Cancer
Authors
Jean-Emmanuel Bibault
Bernard Prevost
Eric Dansin
Xavier Mirabel
Thomas Lacornerie
Eric Lartigau
Publication date
01-12-2012
Publisher
BioMed Central
Published in
Radiation Oncology / Issue 1/2012
Electronic ISSN: 1748-717X
DOI
https://doi.org/10.1186/1748-717X-7-102

Other articles of this Issue 1/2012

Radiation Oncology 1/2012 Go to the issue