Skip to main content
Top
Published in: BMC Medicine 1/2011

Open Access 01-12-2011 | Review

Closed-loop insulin delivery for treatment of type 1 diabetes

Authors: Daniela Elleri, David B Dunger, Roman Hovorka

Published in: BMC Medicine | Issue 1/2011

Login to get access

Abstract

Type 1 diabetes is one of the most common endocrine problems in childhood and adolescence, and remains a serious chronic disorder with increased morbidity and mortality, and reduced quality of life. Technological innovations positively affect the management of type 1 diabetes. Closed-loop insulin delivery (artificial pancreas) is a recent medical innovation, aiming to reduce the risk of hypoglycemia while achieving tight control of glucose. Characterized by real-time glucose-responsive insulin administration, closed-loop systems combine glucose-sensing and insulin-delivery components. In the most viable and researched configuration, a disposable sensor measures interstitial glucose levels, which are fed into a control algorithm controlling delivery of a rapid-acting insulin analog into the subcutaneous tissue by an insulin pump. Research progress builds on an increasing use of insulin pumps and availability of glucose monitors. We review the current status of insulin delivery, focusing on clinical evaluations of closed-loop systems. Future goals are outlined, and benefits and limitations of closed-loop therapy contrasted. The clinical utility of these systems is constrained by inaccuracies in glucose sensing, inter- and intra-patient variability, and delays due to absorption of insulin from the subcutaneous tissue, all of which are being gradually addressed.
Appendix
Available only for authorised users
Literature
1.
2.
go back to reference Diabetes Control and Complication Trial Study Group (DCCT): The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes-mellitus. N Engl J Med. 1993, 329: 977-986.CrossRef Diabetes Control and Complication Trial Study Group (DCCT): The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes-mellitus. N Engl J Med. 1993, 329: 977-986.CrossRef
4.
go back to reference Nixon R, Pickup JC: Fear of hypoglycemia in type 1 diabetes managed by continuous subcutaneous insulin infusion: is it associated with poor glycemic control?. Diabetes Technol Ther. 2011, 13: 93-98. 10.1089/dia.2010.0192.CrossRefPubMed Nixon R, Pickup JC: Fear of hypoglycemia in type 1 diabetes managed by continuous subcutaneous insulin infusion: is it associated with poor glycemic control?. Diabetes Technol Ther. 2011, 13: 93-98. 10.1089/dia.2010.0192.CrossRefPubMed
5.
go back to reference Wild D, Von Maltzahn R, Brohan E, Christensen T, Clauson P, Gonder-Frederick L: A critical review of the literature on fear of hypoglycemia in diabetes: Implications for diabetes management and patient education. Patient Educ Couns. 2007, 68: 10-15. 10.1016/j.pec.2007.05.003.CrossRefPubMed Wild D, Von Maltzahn R, Brohan E, Christensen T, Clauson P, Gonder-Frederick L: A critical review of the literature on fear of hypoglycemia in diabetes: Implications for diabetes management and patient education. Patient Educ Couns. 2007, 68: 10-15. 10.1016/j.pec.2007.05.003.CrossRefPubMed
6.
go back to reference Klonoff DC: Continuous glucose monitoring: roadmap for 21st century diabetes therapy. Diabetes Care. 2005, 28: 1231-1239. 10.2337/diacare.28.5.1231.CrossRefPubMed Klonoff DC: Continuous glucose monitoring: roadmap for 21st century diabetes therapy. Diabetes Care. 2005, 28: 1231-1239. 10.2337/diacare.28.5.1231.CrossRefPubMed
7.
go back to reference Bergenstal RM, Tamborlane WV, Ahmann A, Buse JB, Dailey G, Davis SN, Joyce C, Peoples T, Perkins BA, Welsh JB, Willi SM, Wood MA: Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes. N Engl J Med. 2010, 363: 311-320. 10.1056/NEJMoa1002853.CrossRefPubMed Bergenstal RM, Tamborlane WV, Ahmann A, Buse JB, Dailey G, Davis SN, Joyce C, Peoples T, Perkins BA, Welsh JB, Willi SM, Wood MA: Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes. N Engl J Med. 2010, 363: 311-320. 10.1056/NEJMoa1002853.CrossRefPubMed
8.
go back to reference Tamborlane WV, Beck RW, Bode BW, Buckingham B, Chase HP, Clemons R, Fiallo-Scharer R, Fox LA, Gilliam LK, Hirsch IB, Huang ES, Kollman C, Kowalski AJ, Laffel L, Lawrence JM, Lee J, Mauras N, O'Grady M, Ruedy KJ, Tansey M, Tsalikian E, Weinzimer S, Wilson DM, Wolpert H, Wysocki T, Xing D: Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med. 2008, 359: 1464-1476.CrossRefPubMed Tamborlane WV, Beck RW, Bode BW, Buckingham B, Chase HP, Clemons R, Fiallo-Scharer R, Fox LA, Gilliam LK, Hirsch IB, Huang ES, Kollman C, Kowalski AJ, Laffel L, Lawrence JM, Lee J, Mauras N, O'Grady M, Ruedy KJ, Tansey M, Tsalikian E, Weinzimer S, Wilson DM, Wolpert H, Wysocki T, Xing D: Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med. 2008, 359: 1464-1476.CrossRefPubMed
9.
10.
go back to reference Steil GM, Rebrin K: Closed-loop insulin delivery - what lies between where we are and where we are going?. Expert Opin Drug Deliv. 2005, 2: 353-362. 10.1517/17425247.2.2.353.CrossRefPubMed Steil GM, Rebrin K: Closed-loop insulin delivery - what lies between where we are and where we are going?. Expert Opin Drug Deliv. 2005, 2: 353-362. 10.1517/17425247.2.2.353.CrossRefPubMed
11.
go back to reference Renard E, Costalat G, Chevassus H, Bringer J: Artificial beta-cell: clinical experience toward an implantable closed-loop insulin delivery system. Diabetes Metab. 2006, 32: 497-502. 10.1016/S1262-3636(06)72802-6.CrossRefPubMed Renard E, Costalat G, Chevassus H, Bringer J: Artificial beta-cell: clinical experience toward an implantable closed-loop insulin delivery system. Diabetes Metab. 2006, 32: 497-502. 10.1016/S1262-3636(06)72802-6.CrossRefPubMed
12.
go back to reference Hovorka R: Closed-loop insulin delivery: from bench to clinical practice. Nat Rev Endocrinol. 2011, 7: 385-395. 10.1038/nrendo.2011.32.CrossRefPubMed Hovorka R: Closed-loop insulin delivery: from bench to clinical practice. Nat Rev Endocrinol. 2011, 7: 385-395. 10.1038/nrendo.2011.32.CrossRefPubMed
13.
go back to reference Bequette BW: A critical assessment of algorithms and challenges in the development of a closed-loop artificial pancreas. Diabetes Technol Ther. 2005, 7: 28-47. 10.1089/dia.2005.7.28.CrossRefPubMed Bequette BW: A critical assessment of algorithms and challenges in the development of a closed-loop artificial pancreas. Diabetes Technol Ther. 2005, 7: 28-47. 10.1089/dia.2005.7.28.CrossRefPubMed
14.
go back to reference Marchetti G, Barolo M, Jovanovic L, Zisser H, Seborg DE: An improved PID switching control strategy for type 1 diabetes. IEEE Trans Biomed Eng. 2008, 55: 857-865.CrossRefPubMed Marchetti G, Barolo M, Jovanovic L, Zisser H, Seborg DE: An improved PID switching control strategy for type 1 diabetes. IEEE Trans Biomed Eng. 2008, 55: 857-865.CrossRefPubMed
15.
go back to reference Steil GM, Panteleon AE, Rebrin K: Closed-loop insulin delivery-the path to physiological glucose control. Adv Drug Deliv Rev. 2004, 56: 125-144. 10.1016/j.addr.2003.08.011.CrossRefPubMed Steil GM, Panteleon AE, Rebrin K: Closed-loop insulin delivery-the path to physiological glucose control. Adv Drug Deliv Rev. 2004, 56: 125-144. 10.1016/j.addr.2003.08.011.CrossRefPubMed
16.
go back to reference Hovorka R, Canonico V, Chassin LJ, Haueter U, Massi-Benedetti M, Orsini FM, Pieber TR, Schaller HC, Schaupp L, Vering T, Wilinska ME: Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes. Physiol Meas. 2004, 25: 905-920. 10.1088/0967-3334/25/4/010.CrossRefPubMed Hovorka R, Canonico V, Chassin LJ, Haueter U, Massi-Benedetti M, Orsini FM, Pieber TR, Schaller HC, Schaupp L, Vering T, Wilinska ME: Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes. Physiol Meas. 2004, 25: 905-920. 10.1088/0967-3334/25/4/010.CrossRefPubMed
17.
go back to reference Magni L, Raimondo DM, Bossi L, Man CD, De NG, Kovatchev B, Cobelli C: Model predictive control of type 1 diabetes: an in silico trial. J Diabetes Sci Technol. 2007, 1: 804-812.CrossRefPubMedPubMedCentral Magni L, Raimondo DM, Bossi L, Man CD, De NG, Kovatchev B, Cobelli C: Model predictive control of type 1 diabetes: an in silico trial. J Diabetes Sci Technol. 2007, 1: 804-812.CrossRefPubMedPubMedCentral
18.
go back to reference Parker RS, Doyle FJ, Peppas NA: A model-based algorithm for blood glucose control in type I diabetic patients. IEEE Trans Biomed Eng. 1999, 46: 148-157. 10.1109/10.740877.CrossRefPubMed Parker RS, Doyle FJ, Peppas NA: A model-based algorithm for blood glucose control in type I diabetic patients. IEEE Trans Biomed Eng. 1999, 46: 148-157. 10.1109/10.740877.CrossRefPubMed
19.
go back to reference El-Khatib FH, Jiang J, Damiano ER: Adaptive closed-loop control provides blood-glucose regulation using dual subcutaneous insulin and glucagon infusion in diabetic swine. J Diabetes Sci Technol. 2007, 1: 181-192.CrossRefPubMedPubMedCentral El-Khatib FH, Jiang J, Damiano ER: Adaptive closed-loop control provides blood-glucose regulation using dual subcutaneous insulin and glucagon infusion in diabetic swine. J Diabetes Sci Technol. 2007, 1: 181-192.CrossRefPubMedPubMedCentral
20.
go back to reference Lee H, Buckingham BA, Wilson DM, Bequette BW: A closed-loop artificial pancreas using model predictive control and a sliding meal size estimator. J Diabetes Sci Technol. 2009, 3: 1082-1090.CrossRefPubMedPubMedCentral Lee H, Buckingham BA, Wilson DM, Bequette BW: A closed-loop artificial pancreas using model predictive control and a sliding meal size estimator. J Diabetes Sci Technol. 2009, 3: 1082-1090.CrossRefPubMedPubMedCentral
21.
go back to reference Wang Y, Dassau E, Doyle FJ: Closed-loop control of artificial pancreatic Beta -cell in type 1 diabetes mellitus using model predictive iterative learning control. IEEE Trans Biomed Eng. 2010, 57: 211-219.CrossRefPubMed Wang Y, Dassau E, Doyle FJ: Closed-loop control of artificial pancreatic Beta -cell in type 1 diabetes mellitus using model predictive iterative learning control. IEEE Trans Biomed Eng. 2010, 57: 211-219.CrossRefPubMed
22.
go back to reference Grosman B, Dassau E, Zisser HC, Jovanovic L, Doyle FJ: Zone model predictive control: a strategy to minimize hyper- and hypoglycemic events. J Diabetes Sci Technol. 2010, 4: 961-975.CrossRefPubMedPubMedCentral Grosman B, Dassau E, Zisser HC, Jovanovic L, Doyle FJ: Zone model predictive control: a strategy to minimize hyper- and hypoglycemic events. J Diabetes Sci Technol. 2010, 4: 961-975.CrossRefPubMedPubMedCentral
23.
go back to reference Kovatchev B, Patek S, Dassau E, Doyle FJ, Magni L, De NG, Cobelli C: Control to range for diabetes: functionality and modular architecture. J Diabetes Sci Technol. 2009, 3: 1058-1065.CrossRefPubMedPubMedCentral Kovatchev B, Patek S, Dassau E, Doyle FJ, Magni L, De NG, Cobelli C: Control to range for diabetes: functionality and modular architecture. J Diabetes Sci Technol. 2009, 3: 1058-1065.CrossRefPubMedPubMedCentral
24.
go back to reference Hovorka R, Allen JM, Elleri D, Chassin LJ, Harris J, Xing D, Kollman C, Hovorka T, Larsen AM, Nodale M, De PA, Wilinska ME, Acerini CL, Dunger DB: Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trial. Lancet. 2010, 375: 743-751. 10.1016/S0140-6736(09)61998-X.CrossRefPubMed Hovorka R, Allen JM, Elleri D, Chassin LJ, Harris J, Xing D, Kollman C, Hovorka T, Larsen AM, Nodale M, De PA, Wilinska ME, Acerini CL, Dunger DB: Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trial. Lancet. 2010, 375: 743-751. 10.1016/S0140-6736(09)61998-X.CrossRefPubMed
25.
go back to reference Atlas E, Nimri R, Miller S, Grunberg EA, Phillip M: MD-logic artificial pancreas system: a pilot study in adults with type 1 diabetes. Diabetes Care. 2010, 33: 1072-1076. 10.2337/dc09-1830.CrossRefPubMedPubMedCentral Atlas E, Nimri R, Miller S, Grunberg EA, Phillip M: MD-logic artificial pancreas system: a pilot study in adults with type 1 diabetes. Diabetes Care. 2010, 33: 1072-1076. 10.2337/dc09-1830.CrossRefPubMedPubMedCentral
26.
go back to reference Steil GM, Palerm CC, Kurtz N, Voskanyan G, Roy A, Paz S, Kandeel FR: The effect of insulin feedback on closed loop glucose control. J Clin Endocrinol Metab. 2011, 96: 1402-1408. 10.1210/jc.2010-2578.CrossRefPubMedPubMedCentral Steil GM, Palerm CC, Kurtz N, Voskanyan G, Roy A, Paz S, Kandeel FR: The effect of insulin feedback on closed loop glucose control. J Clin Endocrinol Metab. 2011, 96: 1402-1408. 10.1210/jc.2010-2578.CrossRefPubMedPubMedCentral
27.
go back to reference Kowalski AJ: Can we really close the loop and how soon? Accelerating the availability of an artificial pancreas: a roadmap to better diabetes outcomes. Diabetes Technol Ther. 2009, 11: S113-S119. 10.1089/dia.2008.0021.CrossRefPubMed Kowalski AJ: Can we really close the loop and how soon? Accelerating the availability of an artificial pancreas: a roadmap to better diabetes outcomes. Diabetes Technol Ther. 2009, 11: S113-S119. 10.1089/dia.2008.0021.CrossRefPubMed
28.
go back to reference Buckingham B, Wilson DM, Lecher T, Hanas R, Kaiserman K, Cameron F: Duration of nocturnal hypoglycemia before seizures. Diabetes Care. 2008, 31: 2110-2112. 10.2337/dc08-0863.CrossRefPubMedPubMedCentral Buckingham B, Wilson DM, Lecher T, Hanas R, Kaiserman K, Cameron F: Duration of nocturnal hypoglycemia before seizures. Diabetes Care. 2008, 31: 2110-2112. 10.2337/dc08-0863.CrossRefPubMedPubMedCentral
29.
go back to reference Cryer PE: Glucose counterregulation in normal and diabetic man. Clin Physiol. 1985, 5 (Suppl 5): 61-65.PubMed Cryer PE: Glucose counterregulation in normal and diabetic man. Clin Physiol. 1985, 5 (Suppl 5): 61-65.PubMed
30.
go back to reference Cryer PE: Mechanisms of hypoglycemia-associated autonomic failure and its component syndromes in diabetes. Diabetes. 2005, 54: 3592-3601. 10.2337/diabetes.54.12.3592.CrossRefPubMed Cryer PE: Mechanisms of hypoglycemia-associated autonomic failure and its component syndromes in diabetes. Diabetes. 2005, 54: 3592-3601. 10.2337/diabetes.54.12.3592.CrossRefPubMed
31.
go back to reference Simonson DC, Tamborlane WV, DeFronzo RA, Sherwin RS: Intensive insulin therapy reduces counterregulatory hormone responses to hypoglycemia in patients with type I diabetes. Ann. Intern Med. 1985, 103: 184-190. Simonson DC, Tamborlane WV, DeFronzo RA, Sherwin RS: Intensive insulin therapy reduces counterregulatory hormone responses to hypoglycemia in patients with type I diabetes. Ann. Intern Med. 1985, 103: 184-190.
32.
go back to reference Jones TW, Porter P, Sherwin RS, Davis EA, O'Leary P, Frazer F, Byrne G, Stick S, Tamborlane WV: Decreased epinephrine responses to hypoglycemia during sleep. N Engl J Med. 1998, 338: 1657-1662. 10.1056/NEJM199806043382303.CrossRefPubMed Jones TW, Porter P, Sherwin RS, Davis EA, O'Leary P, Frazer F, Byrne G, Stick S, Tamborlane WV: Decreased epinephrine responses to hypoglycemia during sleep. N Engl J Med. 1998, 338: 1657-1662. 10.1056/NEJM199806043382303.CrossRefPubMed
33.
go back to reference Pickup JC: Semi-closed-loop insulin delivery systems: early experience with low-glucose insulin suspend pumps. Diabetes Technol Ther. 2011, 13: 695-698. 10.1089/dia.2011.0103.CrossRefPubMed Pickup JC: Semi-closed-loop insulin delivery systems: early experience with low-glucose insulin suspend pumps. Diabetes Technol Ther. 2011, 13: 695-698. 10.1089/dia.2011.0103.CrossRefPubMed
34.
go back to reference Attia N, Jones TW, Holcombe J, Tamborlane WV: Comparison of human regular and lispro insulins after interruption of continuous subcutaneous insulin infusion and in the treatment of acutely decompensated IDDM. Diabetes Care. 1998, 21: 817-821. 10.2337/diacare.21.5.817.CrossRefPubMed Attia N, Jones TW, Holcombe J, Tamborlane WV: Comparison of human regular and lispro insulins after interruption of continuous subcutaneous insulin infusion and in the treatment of acutely decompensated IDDM. Diabetes Care. 1998, 21: 817-821. 10.2337/diacare.21.5.817.CrossRefPubMed
35.
go back to reference Guerci B, Meyer L, Salle A, Charrie A, Dousset B, Ziegler O, Drouin P: Comparison of metabolic deterioration between insulin analog and regular insulin after a 5-hour interruption of a continuous subcutaneous insulin infusion in type 1 diabetic patients. J Clin Endocrinol Metab. 1999, 84: 2673-2678. 10.1210/jc.84.8.2673.PubMed Guerci B, Meyer L, Salle A, Charrie A, Dousset B, Ziegler O, Drouin P: Comparison of metabolic deterioration between insulin analog and regular insulin after a 5-hour interruption of a continuous subcutaneous insulin infusion in type 1 diabetic patients. J Clin Endocrinol Metab. 1999, 84: 2673-2678. 10.1210/jc.84.8.2673.PubMed
36.
go back to reference Krzentowski G, Scheen A, Castillo M, Luyckx AS, Lefebvre PJ: A 6-hour nocturnal interruption of a continuous subcutaneous insulin infusion. Metabolic and hormonal consequences and scheme for a prompt return to adequate control. Diabetologia. 1983, 24: 314-318.CrossRefPubMed Krzentowski G, Scheen A, Castillo M, Luyckx AS, Lefebvre PJ: A 6-hour nocturnal interruption of a continuous subcutaneous insulin infusion. Metabolic and hormonal consequences and scheme for a prompt return to adequate control. Diabetologia. 1983, 24: 314-318.CrossRefPubMed
37.
go back to reference Pickup JC, Viberti GC, Bilous RW, Keen H, Alberti KGMM, Home PD, Binder C: Safety of continuous subcutaneous insulin infusion. Metabolic deterioration and glycemic auto-regulation after deliberate cessation of infusion. Diabetologia. 1982, 22: 175-179.CrossRefPubMed Pickup JC, Viberti GC, Bilous RW, Keen H, Alberti KGMM, Home PD, Binder C: Safety of continuous subcutaneous insulin infusion. Metabolic deterioration and glycemic auto-regulation after deliberate cessation of infusion. Diabetologia. 1982, 22: 175-179.CrossRefPubMed
38.
go back to reference Scheen A, Castillo M, Jandrain B, Krzentowski G, Henrivaux P, Luyckx A, Lefebvre P: A 2-hour nocturnal interruption of continuous subcutaneous insulin infusion induces a delayed and sustained metabolic deterioration in C-peptide negative type-1 (insulin-dependent) diabetic patients. Diabetologia. 1983, 25: 192-192. Scheen A, Castillo M, Jandrain B, Krzentowski G, Henrivaux P, Luyckx A, Lefebvre P: A 2-hour nocturnal interruption of continuous subcutaneous insulin infusion induces a delayed and sustained metabolic deterioration in C-peptide negative type-1 (insulin-dependent) diabetic patients. Diabetologia. 1983, 25: 192-192.
39.
go back to reference Buckingham B, Cobry E, Clinton P, Gage V, Caswell K, Kunselman E, Cameron F, Chase HP: Preventing hypoglycemia using predictive alarm algorithms and insulin pump suspension. Diabetes Technol Ther. 2009, 11: 93-97. 10.1089/dia.2008.0032.CrossRefPubMedPubMedCentral Buckingham B, Cobry E, Clinton P, Gage V, Caswell K, Kunselman E, Cameron F, Chase HP: Preventing hypoglycemia using predictive alarm algorithms and insulin pump suspension. Diabetes Technol Ther. 2009, 11: 93-97. 10.1089/dia.2008.0032.CrossRefPubMedPubMedCentral
40.
go back to reference Buckingham B, Chase HP, Dassau E, Cobry E, Clinton P, Gage V, Caswell K, Wilkinson J, Cameron F, Lee H, Bequette BW, Doyle FJ: Prevention of nocturnal hypoglycemia using predictive alarm algorithms and insulin pump suspension. Diabetes Care. 2010, 33: 1013-1017. 10.2337/dc09-2303.CrossRefPubMedPubMedCentral Buckingham B, Chase HP, Dassau E, Cobry E, Clinton P, Gage V, Caswell K, Wilkinson J, Cameron F, Lee H, Bequette BW, Doyle FJ: Prevention of nocturnal hypoglycemia using predictive alarm algorithms and insulin pump suspension. Diabetes Care. 2010, 33: 1013-1017. 10.2337/dc09-2303.CrossRefPubMedPubMedCentral
41.
go back to reference Diabetes Control and Complication Trial Study Group (DCCT): Epidemiology of severe hypoglycemia in the diabetes control and complications trial. Am J Med. 1991, 90: 450-459.CrossRef Diabetes Control and Complication Trial Study Group (DCCT): Epidemiology of severe hypoglycemia in the diabetes control and complications trial. Am J Med. 1991, 90: 450-459.CrossRef
42.
go back to reference Elleri D, Acerini CL, Allen JM, Hayes J, Pesterfield C, Wilinska ME, Dunger DB, Hovorka R: Parental attitudes towards overnight closed-loop glucose control in children with type 1 diabetes. Diabetes Technol Ther. 2010, 12: 35-39. 10.1089/dia.2009.0084.CrossRefPubMed Elleri D, Acerini CL, Allen JM, Hayes J, Pesterfield C, Wilinska ME, Dunger DB, Hovorka R: Parental attitudes towards overnight closed-loop glucose control in children with type 1 diabetes. Diabetes Technol Ther. 2010, 12: 35-39. 10.1089/dia.2009.0084.CrossRefPubMed
43.
go back to reference Hovorka R, Kumareswaran K, Harris J, Allen JM, Elleri D, Xing D, Kollman C, Nodale M, Murphy HR, Dunger DB, Amiel SA, Heller SR, Wilinska ME, Evans ML: Overnight closed loop insulin delivery (artificial pancreas) in adults with type 1 diabetes: crossover randomised controlled studies. BMJ. 2011, 342: d1855-10.1136/bmj.d1855.CrossRefPubMedPubMedCentral Hovorka R, Kumareswaran K, Harris J, Allen JM, Elleri D, Xing D, Kollman C, Nodale M, Murphy HR, Dunger DB, Amiel SA, Heller SR, Wilinska ME, Evans ML: Overnight closed loop insulin delivery (artificial pancreas) in adults with type 1 diabetes: crossover randomised controlled studies. BMJ. 2011, 342: d1855-10.1136/bmj.d1855.CrossRefPubMedPubMedCentral
44.
go back to reference Murphy HR, Elleri D, Allen JM, Harris J, Simmons D, Rayman G, Temple R, Dunger DB, Haidar A, Nodale M, Wilinska ME, Hovorka R: Closed-loop insulin delivery during pregnancy complicated by type 1 diabetes. Diabetes Care. 2011, 34: 406-411. 10.2337/dc10-1796.CrossRefPubMedPubMedCentral Murphy HR, Elleri D, Allen JM, Harris J, Simmons D, Rayman G, Temple R, Dunger DB, Haidar A, Nodale M, Wilinska ME, Hovorka R: Closed-loop insulin delivery during pregnancy complicated by type 1 diabetes. Diabetes Care. 2011, 34: 406-411. 10.2337/dc10-1796.CrossRefPubMedPubMedCentral
45.
go back to reference Weinzimer SA, Steil GM, Swan KL, Dziura J, Kurtz N, Tamborlane WV: Fully automated closed-loop insulin delivery versus semi-automated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas. Diabetes Care. 2008, 31: 934-939. 10.2337/dc07-1967.CrossRefPubMed Weinzimer SA, Steil GM, Swan KL, Dziura J, Kurtz N, Tamborlane WV: Fully automated closed-loop insulin delivery versus semi-automated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas. Diabetes Care. 2008, 31: 934-939. 10.2337/dc07-1967.CrossRefPubMed
46.
go back to reference Murphy HR, Kumareswaran K, Elleri D, Allen JM, Caldwell K, Biagioni M, Simmons D, Dunger DB, Nodale M, Wilinska ME, Amiel SA, Hovorka R: Safety and efficacy of 24 h closed-loop insulin delivery in well-controlled pregnant women with type 1 diabetes: a randomized crossover case series. Diabetes Care. 2011. Murphy HR, Kumareswaran K, Elleri D, Allen JM, Caldwell K, Biagioni M, Simmons D, Dunger DB, Nodale M, Wilinska ME, Amiel SA, Hovorka R: Safety and efficacy of 24 h closed-loop insulin delivery in well-controlled pregnant women with type 1 diabetes: a randomized crossover case series. Diabetes Care. 2011.
47.
go back to reference Castle JR, Engle JM, El YJ, Massoud RG, Yuen KC, Kagan R, Ward WK: Novel use of glucagon in a closed-loop system for prevention of hypoglycemia in type 1 diabetes. Diabetes Care. 2010, 33: 1282-1287. 10.2337/dc09-2254.CrossRefPubMedPubMedCentral Castle JR, Engle JM, El YJ, Massoud RG, Yuen KC, Kagan R, Ward WK: Novel use of glucagon in a closed-loop system for prevention of hypoglycemia in type 1 diabetes. Diabetes Care. 2010, 33: 1282-1287. 10.2337/dc09-2254.CrossRefPubMedPubMedCentral
48.
go back to reference El-Khatib FH, Russell SJ, Nathan DM, Sutherlin RG, Damiano ER: A bihormonal closed-loop artificial pancreas for type 1 diabetes. Sci Transl Med. 2010, 2: 27ra27-10.1126/scitranslmed.3000619.CrossRefPubMedPubMedCentral El-Khatib FH, Russell SJ, Nathan DM, Sutherlin RG, Damiano ER: A bihormonal closed-loop artificial pancreas for type 1 diabetes. Sci Transl Med. 2010, 2: 27ra27-10.1126/scitranslmed.3000619.CrossRefPubMedPubMedCentral
49.
go back to reference Wilinska ME, Chassin LJ, Acerini CL, Allen JM, Dunger DB, Hovorka R: Simulation environment to evaluate closed-loop insulin delivery systems in type 1 diabetes. J Diabetes Sci Technol. 2010, 4: 132-144.CrossRefPubMedPubMedCentral Wilinska ME, Chassin LJ, Acerini CL, Allen JM, Dunger DB, Hovorka R: Simulation environment to evaluate closed-loop insulin delivery systems in type 1 diabetes. J Diabetes Sci Technol. 2010, 4: 132-144.CrossRefPubMedPubMedCentral
50.
go back to reference Kovatchev BP, Breton M, Man CD, Cobelli C: In silico preclinical trials: a proof of concept in closed-loop control of type 1 diabetes. J Diabetes Sci Technol. 2009, 3: 44-55.CrossRefPubMedPubMedCentral Kovatchev BP, Breton M, Man CD, Cobelli C: In silico preclinical trials: a proof of concept in closed-loop control of type 1 diabetes. J Diabetes Sci Technol. 2009, 3: 44-55.CrossRefPubMedPubMedCentral
51.
go back to reference Wilinska ME, Budiman ES, Taub MB, Elleri D, Allen JM, Acerini CL, Dunger DB, Hovorka R: Overnight closed-loop insulin delivery with model predictive control: assessment of hypoglycemia and hyperglycemia risk using simulation studies. J Diabetes Sci Technol. 2009, 3: 1109-1120.CrossRefPubMedPubMedCentral Wilinska ME, Budiman ES, Taub MB, Elleri D, Allen JM, Acerini CL, Dunger DB, Hovorka R: Overnight closed-loop insulin delivery with model predictive control: assessment of hypoglycemia and hyperglycemia risk using simulation studies. J Diabetes Sci Technol. 2009, 3: 1109-1120.CrossRefPubMedPubMedCentral
52.
go back to reference Kanderian SS, Weinzimer S, Voskanyan G, Steil GM: Identification of intraday metabolic profiles during closed-loop glucose control in individuals with type 1 diabetes. J Diabetes Sci Technol. 2009, 3: 1047-1057.CrossRefPubMedPubMedCentral Kanderian SS, Weinzimer S, Voskanyan G, Steil GM: Identification of intraday metabolic profiles during closed-loop glucose control in individuals with type 1 diabetes. J Diabetes Sci Technol. 2009, 3: 1047-1057.CrossRefPubMedPubMedCentral
53.
go back to reference Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group: Satisfaction with continuous glucose monitoring in adults and youths with Type 1 diabetes. Diabet Med. 2011, 28 (9): 1118-1122. 10.1111/j.1464-5491.2011.03368.x.CrossRef Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group: Satisfaction with continuous glucose monitoring in adults and youths with Type 1 diabetes. Diabet Med. 2011, 28 (9): 1118-1122. 10.1111/j.1464-5491.2011.03368.x.CrossRef
54.
go back to reference Elleri D, Harris J, Kumareswaran K, Allen JM, Haidar A, Nodale M, Swamy A, Wilinska ME, Weston J, Acerini CL, Jackson N, Umpleby AM, Evans ML, Dunger DB, Hovorka R: Glucose appearance of large slowly-absorbed evening meal containing complex carbohydrates (CHO) in type 1 diabetes (T1D). Diabetologia. 2010, 53 (Suppl 1): S 272. Elleri D, Harris J, Kumareswaran K, Allen JM, Haidar A, Nodale M, Swamy A, Wilinska ME, Weston J, Acerini CL, Jackson N, Umpleby AM, Evans ML, Dunger DB, Hovorka R: Glucose appearance of large slowly-absorbed evening meal containing complex carbohydrates (CHO) in type 1 diabetes (T1D). Diabetologia. 2010, 53 (Suppl 1): S 272.
55.
go back to reference Weinzimer SA, Sherr JL, Cengiz E, Kim G, Carria L, Tamborlane WV: Effect of adjuvant injected pramlintide on closed-loop automated insulin delivery. Diabetes. 2011, 60 (Supll 1): A 253. Weinzimer SA, Sherr JL, Cengiz E, Kim G, Carria L, Tamborlane WV: Effect of adjuvant injected pramlintide on closed-loop automated insulin delivery. Diabetes. 2011, 60 (Supll 1): A 253.
56.
go back to reference Hompesch M, Muchmore DB, Morrow L, Vaughn DE: Accelerated insulin pharmacokinetics and improved postprandial glycemic control in patients with type 1 diabetes after coadministration of prandial insulins with hyaluronidase. Diabetes Care. 2011, 34: 666-668. 10.2337/dc10-1892.CrossRefPubMedPubMedCentral Hompesch M, Muchmore DB, Morrow L, Vaughn DE: Accelerated insulin pharmacokinetics and improved postprandial glycemic control in patients with type 1 diabetes after coadministration of prandial insulins with hyaluronidase. Diabetes Care. 2011, 34: 666-668. 10.2337/dc10-1892.CrossRefPubMedPubMedCentral
57.
go back to reference Steiner S, Hompesch M, Pohl R, Simms P, Flacke F, Mohr T, Pfutzner A, Heinemann L: A novel insulin formulation with a more rapid onset of action. Diabetologia. 2008, 51: 1602-1606. 10.1007/s00125-008-1095-8.CrossRefPubMedPubMedCentral Steiner S, Hompesch M, Pohl R, Simms P, Flacke F, Mohr T, Pfutzner A, Heinemann L: A novel insulin formulation with a more rapid onset of action. Diabetologia. 2008, 51: 1602-1606. 10.1007/s00125-008-1095-8.CrossRefPubMedPubMedCentral
58.
go back to reference Renard E, Place J, Cantwell M, Chevassus H, Palerm CC: Closed-loop insulin delivery using a subcutaneous glucose sensor and intraperitoneal insulin delivery: feasibility study testing a new model for the artificial pancreas. Diabetes Care. 2010, 33: 121-127. 10.2337/dc09-1080.CrossRefPubMed Renard E, Place J, Cantwell M, Chevassus H, Palerm CC: Closed-loop insulin delivery using a subcutaneous glucose sensor and intraperitoneal insulin delivery: feasibility study testing a new model for the artificial pancreas. Diabetes Care. 2010, 33: 121-127. 10.2337/dc09-1080.CrossRefPubMed
59.
go back to reference Liebl A, Hoogma R, Renard E, Geelhoed-Duijvestijn PH, Klein E, Diglas J, Kessler L, Melki V, Diem P, Brun JM, Schaepelynck-Belicar P, Frei T: A reduction in severe hypoglycaemia in type 1 diabetes in a randomized crossover study of continuous intraperitoneal compared with subcutaneous insulin infusion. Diabetes Obes Metab. 2009, 11: 1001-1008. 10.1111/j.1463-1326.2009.01059.x.CrossRefPubMed Liebl A, Hoogma R, Renard E, Geelhoed-Duijvestijn PH, Klein E, Diglas J, Kessler L, Melki V, Diem P, Brun JM, Schaepelynck-Belicar P, Frei T: A reduction in severe hypoglycaemia in type 1 diabetes in a randomized crossover study of continuous intraperitoneal compared with subcutaneous insulin infusion. Diabetes Obes Metab. 2009, 11: 1001-1008. 10.1111/j.1463-1326.2009.01059.x.CrossRefPubMed
60.
go back to reference Kumareswaran K, Elleri D, Allen JM, Harris J, Xing D, Kollman C, Nodale M, Murphy HR, Amiel SA, Heller SR, Wilinska ME, Acerini CL, Evans ML, Dunger DB, Hovorka R: Meta-analysis of overnight closed-loop randomised studies in children and adults with type 1 diabetes: the Cambridge cohort. J Diabetes Sci Technol. 2011. Kumareswaran K, Elleri D, Allen JM, Harris J, Xing D, Kollman C, Nodale M, Murphy HR, Amiel SA, Heller SR, Wilinska ME, Acerini CL, Evans ML, Dunger DB, Hovorka R: Meta-analysis of overnight closed-loop randomised studies in children and adults with type 1 diabetes: the Cambridge cohort. J Diabetes Sci Technol. 2011.
61.
go back to reference Choudhary P, Shin J, Wang Y, Evans ML, Hammond PJ, Kerr D, Shaw JA, Pickup JC, Amiel SA: Insulin pump therapy with automated insulin suspension in response to hypoglycemia: reduction in nocturnal hypoglycemia in those at greatest risk. Diabetes Care. 2011, 34: 2023-2025. 10.2337/dc10-2411.CrossRefPubMedPubMedCentral Choudhary P, Shin J, Wang Y, Evans ML, Hammond PJ, Kerr D, Shaw JA, Pickup JC, Amiel SA: Insulin pump therapy with automated insulin suspension in response to hypoglycemia: reduction in nocturnal hypoglycemia in those at greatest risk. Diabetes Care. 2011, 34: 2023-2025. 10.2337/dc10-2411.CrossRefPubMedPubMedCentral
62.
go back to reference Danne T, Kordonouri O, Holder M, Haberland H, Golembowski S, Remus K, Blasig S, Wadien T, Zierow S, Hartmann R, Thomas A: Prevention of hypoglycemia by using low glucose suspend function in sensor-augmented pump therapy. Diabetes Technol Ther. 2011, 13: 1-6. 10.1089/dia.2010.0116.CrossRef Danne T, Kordonouri O, Holder M, Haberland H, Golembowski S, Remus K, Blasig S, Wadien T, Zierow S, Hartmann R, Thomas A: Prevention of hypoglycemia by using low glucose suspend function in sensor-augmented pump therapy. Diabetes Technol Ther. 2011, 13: 1-6. 10.1089/dia.2010.0116.CrossRef
63.
go back to reference Kovatchev B, Cobelli C, Renard E, Anderson S, Breton M, Patek S, Clarke W, Bruttomesso D, Maran A, Costa S, Avogaro A, Dalla MC, Facchinetti A, Magni L, De NG, Place J, Farret A: Multinational study of subcutaneous model-predictive closed-loop control in type 1 diabetes mellitus: summary of the results. J Diabetes Sci Technol. 2010, 4: 1374-1381.CrossRefPubMedPubMedCentral Kovatchev B, Cobelli C, Renard E, Anderson S, Breton M, Patek S, Clarke W, Bruttomesso D, Maran A, Costa S, Avogaro A, Dalla MC, Facchinetti A, Magni L, De NG, Place J, Farret A: Multinational study of subcutaneous model-predictive closed-loop control in type 1 diabetes mellitus: summary of the results. J Diabetes Sci Technol. 2010, 4: 1374-1381.CrossRefPubMedPubMedCentral
64.
go back to reference Steil GM, Rebrin K, Darwin C, Hariri F, Saad MF: Feasibility of automating insulin delivery for the treatment of type 1 diabetes. Diabetes. 2006, 55: 3344-3350. 10.2337/db06-0419.CrossRefPubMed Steil GM, Rebrin K, Darwin C, Hariri F, Saad MF: Feasibility of automating insulin delivery for the treatment of type 1 diabetes. Diabetes. 2006, 55: 3344-3350. 10.2337/db06-0419.CrossRefPubMed
Metadata
Title
Closed-loop insulin delivery for treatment of type 1 diabetes
Authors
Daniela Elleri
David B Dunger
Roman Hovorka
Publication date
01-12-2011
Publisher
BioMed Central
Published in
BMC Medicine / Issue 1/2011
Electronic ISSN: 1741-7015
DOI
https://doi.org/10.1186/1741-7015-9-120

Other articles of this Issue 1/2011

BMC Medicine 1/2011 Go to the issue