Published in: Journal of Cardiovascular Magnetic Resonance 1/2008

Open Access 01-12-2008 | Research

Correction of misaligned slices in multi-slice cardiovascular magnetic resonance using slice-to-volume registration

Authors: Adam G Chandler, Richard J Pinder, Thomas Netsch, Julia A Schnabel, David J Hawkes, Derek LG Hill, Reza Razavi

Published in: Journal of Cardiovascular Magnetic Resonance | Issue 1/2008

Login to get access

Abstract

A popular technique to reduce respiratory motion for cardiovascular magnetic resonance is to perform a multi-slice acquisition in which a patient holds their breath multiple times during the scan. The feasibility of rigid slice-to-volume registration to correct for misalignments of slice stacks in such images due to differing breath-hold positions is explored. Experimental results indicate that slice-to-volume registration can compensate for the typical misalignments expected. Correction of slice misalignment results in anatomically more correct images, as well as improved left ventricular volume measurements. The interstudy reproducibility has also been improved reducing the number of samples needed for cardiac MR studies.
Appendix
Available only for authorised users
Literature
1.
go back to reference Bellenger NG, Marcus NJ, Rajappan K, Yacoub M, Banner NR, Pennell DJ: Comparison of techniques for the measurement of left ventricular function following cardiac transplantation. J Cardiovasc Magn Reson. 2002, 4 (2): 255-263.CrossRefPubMed Bellenger NG, Marcus NJ, Rajappan K, Yacoub M, Banner NR, Pennell DJ: Comparison of techniques for the measurement of left ventricular function following cardiac transplantation. J Cardiovasc Magn Reson. 2002, 4 (2): 255-263.CrossRefPubMed
2.
go back to reference McConnell MV, Khasgiwala VC, Savord BJ, Chen MH, Chuang ML, Edelman RR, Manning WJ: Comparison of respiratory suppression methods and navigator locations for MR coronary angiography. AJR Am J Roentgenol. 1997, 168 (5): 1369-1375.CrossRefPubMed McConnell MV, Khasgiwala VC, Savord BJ, Chen MH, Chuang ML, Edelman RR, Manning WJ: Comparison of respiratory suppression methods and navigator locations for MR coronary angiography. AJR Am J Roentgenol. 1997, 168 (5): 1369-1375.CrossRefPubMed
3.
go back to reference McLeish K, Hill DL, Atkinson D, Blackall JM, Razavi R: A study of the motion and deformation of the heart due to respiration. IEEE Trans Med Imaging. 2002, 21 (9): 1142-1150.CrossRefPubMed McLeish K, Hill DL, Atkinson D, Blackall JM, Razavi R: A study of the motion and deformation of the heart due to respiration. IEEE Trans Med Imaging. 2002, 21 (9): 1142-1150.CrossRefPubMed
4.
go back to reference Oppelt A, Graumann R, Barfuss H, Fischer H, Hartl W, Shajor A: FISP – a new fast MRI sequence. Electromedica. 1986, 45 (15–18): Oppelt A, Graumann R, Barfuss H, Fischer H, Hartl W, Shajor A: FISP – a new fast MRI sequence. Electromedica. 1986, 45 (15–18):
5.
go back to reference Schar M, Kozerke S, Fischer SE, Boesiger P: Cardiac SSFP imaging at 3 Tesla. Magn Reson Med. 2004, 51 (4): 799-806.CrossRefPubMed Schar M, Kozerke S, Fischer SE, Boesiger P: Cardiac SSFP imaging at 3 Tesla. Magn Reson Med. 2004, 51 (4): 799-806.CrossRefPubMed
6.
go back to reference Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P: SENSE: sensitivity encoding for fast MRI. Magn Reson Med. 1999, 42 (5): 952-962.CrossRefPubMed Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P: SENSE: sensitivity encoding for fast MRI. Magn Reson Med. 1999, 42 (5): 952-962.CrossRefPubMed
7.
go back to reference Weiger M, Pruessmann KP, Boesiger P: Cardiac real-time imaging using SENSE. SENSitivity Encoding scheme. Magn Reson Med. 2000, 43 (2): 177-184.CrossRefPubMed Weiger M, Pruessmann KP, Boesiger P: Cardiac real-time imaging using SENSE. SENSitivity Encoding scheme. Magn Reson Med. 2000, 43 (2): 177-184.CrossRefPubMed
8.
go back to reference Kozerke S, Tsao J, Razavi R, Boesiger P: Accelerating cardiac cine 3D imaging using k-t BLAST. Magn Reson Med. 2004, 52 (1): 19-26.CrossRefPubMed Kozerke S, Tsao J, Razavi R, Boesiger P: Accelerating cardiac cine 3D imaging using k-t BLAST. Magn Reson Med. 2004, 52 (1): 19-26.CrossRefPubMed
9.
go back to reference Lotjonen J, Pollari M, Kivisto S, Lauerma K: Correction of movement artifacts from 4-D Cardiac short- and long-axis MR data. Lectures Notes in Computer Science. 2004, 3217: 405-412.CrossRef Lotjonen J, Pollari M, Kivisto S, Lauerma K: Correction of movement artifacts from 4-D Cardiac short- and long-axis MR data. Lectures Notes in Computer Science. 2004, 3217: 405-412.CrossRef
10.
go back to reference Moore J, Drangova M, Wierzbicki M, Barron J, Peters T: A high resolution dynamic heart model based on averaged MRI data. Lectures Notes in Computer Science. 2003, 2878: 549-555.CrossRef Moore J, Drangova M, Wierzbicki M, Barron J, Peters T: A high resolution dynamic heart model based on averaged MRI data. Lectures Notes in Computer Science. 2003, 2878: 549-555.CrossRef
11.
go back to reference Swingen C, Seethamraju RT, Jerosch-Herold M: An approach to the three-dimensional display of left ventricular function and viability using MRI. Int J Cardiovasc Imaging. 2003, 19 (4): 325-336.CrossRefPubMed Swingen C, Seethamraju RT, Jerosch-Herold M: An approach to the three-dimensional display of left ventricular function and viability using MRI. Int J Cardiovasc Imaging. 2003, 19 (4): 325-336.CrossRefPubMed
12.
go back to reference Hill DLG, Batchelor PG, Holden M, Hawkes DJ: Medical image registration. Physics In Medicine And Biology. 2001, 46 (3): R1-CrossRefPubMed Hill DLG, Batchelor PG, Holden M, Hawkes DJ: Medical image registration. Physics In Medicine And Biology. 2001, 46 (3): R1-CrossRefPubMed
13.
go back to reference Maintz JB, Viergever MA: A survey of medical image registration. Med Image Anal. 1998, 2 (1): 1-36.CrossRefPubMed Maintz JB, Viergever MA: A survey of medical image registration. Med Image Anal. 1998, 2 (1): 1-36.CrossRefPubMed
14.
go back to reference Kim B, Boes JL, Bland PH, Chenevert TL, Meyer CR: Motion correction in fMRI via registration of individual slices into an anatomical volume. Magn Reson Med. 1999, 41 (5): 964-972.CrossRefPubMed Kim B, Boes JL, Bland PH, Chenevert TL, Meyer CR: Motion correction in fMRI via registration of individual slices into an anatomical volume. Magn Reson Med. 1999, 41 (5): 964-972.CrossRefPubMed
15.
go back to reference Kim T, Singh M, Sungkarat W, Zarow C, Chui H: Automatic registration of postmorten brain slices to MRI reference volume. IEEE Trans Nucl Sci. 2000, 47: 1607-1613.CrossRef Kim T, Singh M, Sungkarat W, Zarow C, Chui H: Automatic registration of postmorten brain slices to MRI reference volume. IEEE Trans Nucl Sci. 2000, 47: 1607-1613.CrossRef
16.
go back to reference Chandler A, Netsch T, Cocosco C, Schnabel J, Hawkes D: Slice-to-volume registration using mutual information between probabilistic image classification. Proceedings of SPIE: Medical Imaging. 2004, 5370: 1120-1129.CrossRef Chandler A, Netsch T, Cocosco C, Schnabel J, Hawkes D: Slice-to-volume registration using mutual information between probabilistic image classification. Proceedings of SPIE: Medical Imaging. 2004, 5370: 1120-1129.CrossRef
17.
go back to reference Fei B, Duerk JL, Boll DT, Lewin JS, Wilson DL: Slice-to-volume registration and its potential application to interventional MRI-guided radio-frequency thermal ablation of prostate cancer. IEEE Trans Med Imaging. 2003, 22 (4): 515-525.CrossRefPubMed Fei B, Duerk JL, Boll DT, Lewin JS, Wilson DL: Slice-to-volume registration and its potential application to interventional MRI-guided radio-frequency thermal ablation of prostate cancer. IEEE Trans Med Imaging. 2003, 22 (4): 515-525.CrossRefPubMed
18.
go back to reference Penney GP, Blackall JM, Hamady MS, Sabharwal T, Adam A, Hawkes DJ: Registration of freehand 3D ultrasound and magnetic resonance liver images. Med Image Anal. 2004, 8 (1): 81-91.CrossRefPubMed Penney GP, Blackall JM, Hamady MS, Sabharwal T, Adam A, Hawkes DJ: Registration of freehand 3D ultrasound and magnetic resonance liver images. Med Image Anal. 2004, 8 (1): 81-91.CrossRefPubMed
19.
go back to reference Smolikova R, Wachowiak M, Drangova M: Registration of fast cine cardiac MR slices to 3D preprocedural images: toward real time registration for MRI-guided procedures. Proceedings of SPIE: Medical Imaging. 2004, 5370: 1195-1205.CrossRef Smolikova R, Wachowiak M, Drangova M: Registration of fast cine cardiac MR slices to 3D preprocedural images: toward real time registration for MRI-guided procedures. Proceedings of SPIE: Medical Imaging. 2004, 5370: 1195-1205.CrossRef
20.
go back to reference Studholme C, Hill D, Hawkes D: An overlap invariant entropy measure of 3D medical image alignment. Pattern Recognition. 1999, 32 (71–86): Studholme C, Hill D, Hawkes D: An overlap invariant entropy measure of 3D medical image alignment. Pattern Recognition. 1999, 32 (71–86):
21.
go back to reference Bland M: An introduction to Medical Statistics. 1996, Oxford: Oxford University Press, 334-335. Bland M: An introduction to Medical Statistics. 1996, Oxford: Oxford University Press, 334-335.
22.
go back to reference Bellenger NG, Davies LC, Francis JM, Coats AJ, Pennell DJ: Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2000, 2 (4): 271-278.CrossRefPubMed Bellenger NG, Davies LC, Francis JM, Coats AJ, Pennell DJ: Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2000, 2 (4): 271-278.CrossRefPubMed
23.
go back to reference Bogaert JG, Bosmans HT, Rademakers FE, Bellon EP, Herregods MC, Verschakelen JA, Van de Werf F, Marchal GJ: Left ventricular quantification with breath-hold MR imaging: comparison with echocardiography. Magma. 1995, 3 (1): 5-12.CrossRefPubMed Bogaert JG, Bosmans HT, Rademakers FE, Bellon EP, Herregods MC, Verschakelen JA, Van de Werf F, Marchal GJ: Left ventricular quantification with breath-hold MR imaging: comparison with echocardiography. Magma. 1995, 3 (1): 5-12.CrossRefPubMed
24.
go back to reference Grothues F, Smith GC, Moon JC, Bellenger NG, Collins P, Klein HU, Pennell DJ: Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. Am J Cardiol. 2002, 90 (1): 29-34.CrossRefPubMed Grothues F, Smith GC, Moon JC, Bellenger NG, Collins P, Klein HU, Pennell DJ: Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. Am J Cardiol. 2002, 90 (1): 29-34.CrossRefPubMed
25.
go back to reference Semelka RC, Tomei E, Wagner S, Mayo J, Kondo C, Suzuki J, Caputo GR, Higgins CB: Normal left ventricular dimensions and function: interstudy reproducibility of measurements with cine MR imaging. Radiology. 1990, 174 (3 Pt 1): 763-768.CrossRefPubMed Semelka RC, Tomei E, Wagner S, Mayo J, Kondo C, Suzuki J, Caputo GR, Higgins CB: Normal left ventricular dimensions and function: interstudy reproducibility of measurements with cine MR imaging. Radiology. 1990, 174 (3 Pt 1): 763-768.CrossRefPubMed
26.
go back to reference Studholme C: Measures of 3D medical image alignment. PhD Thesis. 1997, 2: Studholme C: Measures of 3D medical image alignment. PhD Thesis. 1997, 2:
Metadata
Title
Correction of misaligned slices in multi-slice cardiovascular magnetic resonance using slice-to-volume registration
Authors
Adam G Chandler
Richard J Pinder
Thomas Netsch
Julia A Schnabel
David J Hawkes
Derek LG Hill
Reza Razavi
Publication date
01-12-2008
Publisher
BioMed Central
Published in
Journal of Cardiovascular Magnetic Resonance / Issue 1/2008
Electronic ISSN: 1532-429X
DOI
https://doi.org/10.1186/1532-429X-10-13

Other articles of this Issue 1/2008

Journal of Cardiovascular Magnetic Resonance 1/2008 Go to the issue