Published in: Cardiovascular Ultrasound 1/2012

Open Access 01-12-2012 | Research

The pressure/volume relationship during dobutamine stress echocardiography in transplanted heart: comparison with quality of life and coronary anatomy

Authors: Giovanni Minardi, Giordano Zampi, Amedeo Pergolini, Giovanni Pulignano, Massimiliano Scappaticci, Francesca Moschella Orsini, Gaetano Pero, Paola Lilla Della Monica, Giovanni Cioffi, Francesco Musumeci

Published in: Cardiovascular Ultrasound | Issue 1/2012

Login to get access

Abstract

Background

Cardiac allograft vasculopathy (CAV) is a major late complication in cardiac transplant recipients and has a relevant impact on outcome of these patients. Aims of this study: to compare, in cardiac transplant recipients patients, the diagnostic value of pressure/volume relationship (ESPVR) during dobutamine stress echocardiography (DSE) for coronary artery disease, assessed by Multislice Computed Tomography (MSCT), and by coronary angiography (CA). We also analyzed any possible relationship between ESPVR and the Health Related Quality of Life of the patients (HRQoL), evaluated by SF–36 questionnaire.

Methods

25 consecutive patients underwent DSE within 24 hours after MSCT coronary angiogram and then they underwent CA. The HRQoL questionnaire was administered to the patients in the settings of DSE. They were followed-up for 6 months.

Results

DSE has a sensitivity in detecting CAV of 67%, specificity of 95%, positive predictive value of 67% and negative predictive value of 95%; DSE with ESPVR has a sensitivity of 100%, specificity of 95%, positive predictive value of 75%, negative predictive value of 100%; MSCT has a sensitivity of 100%; specificity of 82%; positive predictive value of 43%; negative predictive value of 100%. Htx recipients with a flat-biphasic ESPVR, although asymptomatic, perceived a worst HRQoL compared with the up-sloping ESPVR population, and this is statistically significant for the general health (p 0.0004), the vitality (p 0.0013) and the mental health (p 0.021) SF-36 subscale.

Conclusions

Evaluation with DSE and ESPVR is accurate in the clinical control of heart transplant recipients reserving invasive evaluation only for patients with abnormal contractility indexes.
Appendix
Available only for authorised users
Literature
1.
go back to reference Gao SZ, Schroeder JS, Hunt AS, et al: Acute myocardial infarction in cardiac transplant recipients. Am J Cardiol. 1989, 64: 1093-1097. 10.1016/0002-9149(89)90858-8.CrossRefPubMed Gao SZ, Schroeder JS, Hunt AS, et al: Acute myocardial infarction in cardiac transplant recipients. Am J Cardiol. 1989, 64: 1093-1097. 10.1016/0002-9149(89)90858-8.CrossRefPubMed
2.
go back to reference Halpert I, Goldberg AD, Levine AB, et al: Reinnervation of the transplanted human heart as evidenced from heart rate variability studies. Am J Cardiol. 1996, 77: 180-183. 10.1016/S0002-9149(96)90592-5.CrossRefPubMed Halpert I, Goldberg AD, Levine AB, et al: Reinnervation of the transplanted human heart as evidenced from heart rate variability studies. Am J Cardiol. 1996, 77: 180-183. 10.1016/S0002-9149(96)90592-5.CrossRefPubMed
3.
go back to reference Wilson RF, Mc Ginn AL, Johnson TH, et al: Sympathetic reinnervation after heart transplantation in human beings. J Heart Lung Transplant. 1992, 11: S88-S89.PubMed Wilson RF, Mc Ginn AL, Johnson TH, et al: Sympathetic reinnervation after heart transplantation in human beings. J Heart Lung Transplant. 1992, 11: S88-S89.PubMed
4.
go back to reference Stark RP, Mc Ginn AL, Wilson RF: Chest pain in cardiactransplant recipients. Evidence of sensory reinnervation after cardiac transplantation. N Engl J Med. 1991, 324: 1791-1794. 10.1056/NEJM199106203242507.CrossRefPubMed Stark RP, Mc Ginn AL, Wilson RF: Chest pain in cardiactransplant recipients. Evidence of sensory reinnervation after cardiac transplantation. N Engl J Med. 1991, 324: 1791-1794. 10.1056/NEJM199106203242507.CrossRefPubMed
5.
go back to reference Thompson D, Koster MJ, Wagner RH, Heroux A, Barron JT: Single photon emission computed tomography myocardial perfusion imaging to detect cardiac allograft vasculopathy. Eur Heart J Cardiovasc Imaging. 2012, 13: 271-275. 10.1093/ejechocard/jer270.CrossRefPubMed Thompson D, Koster MJ, Wagner RH, Heroux A, Barron JT: Single photon emission computed tomography myocardial perfusion imaging to detect cardiac allograft vasculopathy. Eur Heart J Cardiovasc Imaging. 2012, 13: 271-275. 10.1093/ejechocard/jer270.CrossRefPubMed
6.
go back to reference Akosah KO, Mohanty PK, Funai JT, et al: Noninvasive detection of transplant coronary artery disease by dobutamine stress echocardiography. J Heart Lung Transplant. 1994, 13: 1024-1038.PubMed Akosah KO, Mohanty PK, Funai JT, et al: Noninvasive detection of transplant coronary artery disease by dobutamine stress echocardiography. J Heart Lung Transplant. 1994, 13: 1024-1038.PubMed
7.
go back to reference Akosah KO, McDaniel S, Hanrahan JS, et al: Dobutamine stress echocardiography early after heart transplantation predicts development of allograft coronary artery disease and outcome. J Am Coll Cardiol. 1998, 31: 1607-1614. 10.1016/S0735-1097(98)00169-7.CrossRefPubMed Akosah KO, McDaniel S, Hanrahan JS, et al: Dobutamine stress echocardiography early after heart transplantation predicts development of allograft coronary artery disease and outcome. J Am Coll Cardiol. 1998, 31: 1607-1614. 10.1016/S0735-1097(98)00169-7.CrossRefPubMed
8.
go back to reference Akosah KO, Olsovsky M, Kirchberg D, et al: Dobutamine stress echocardiography predicts cardiac events in heart transplant patients. Circulation. 1996, 94: SII283-SII288. Akosah KO, Olsovsky M, Kirchberg D, et al: Dobutamine stress echocardiography predicts cardiac events in heart transplant patients. Circulation. 1996, 94: SII283-SII288.
9.
go back to reference Bacal F, Moreira LF, Souza G, et al: Dobutamine stress echocardiography predicts cardiac events or death in asymptomatic patients long-term after heart transplantation: 4-year prospective evaluation. J Heart Lung Transplant. 2004, 23: 1238-1244. 10.1016/j.healun.2003.09.007.CrossRefPubMed Bacal F, Moreira LF, Souza G, et al: Dobutamine stress echocardiography predicts cardiac events or death in asymptomatic patients long-term after heart transplantation: 4-year prospective evaluation. J Heart Lung Transplant. 2004, 23: 1238-1244. 10.1016/j.healun.2003.09.007.CrossRefPubMed
10.
go back to reference Mastrobuoni S, Bastarrika G, Ubilla M, et al: Dual-source CT coronary angiogram in heart transplant recipients in comparison with dobutamine stress echocardiography for detection of cardiac allograft vasculopathy. Transplantation. 2009, 87: 587-590. 10.1097/TP.0b013e318195a5a7.CrossRefPubMed Mastrobuoni S, Bastarrika G, Ubilla M, et al: Dual-source CT coronary angiogram in heart transplant recipients in comparison with dobutamine stress echocardiography for detection of cardiac allograft vasculopathy. Transplantation. 2009, 87: 587-590. 10.1097/TP.0b013e318195a5a7.CrossRefPubMed
11.
go back to reference Bombardini T, Galderisi M, Agricola E, et al: Negative stress echo: further prognostic stratification with assessment of pressure-volume relation. Int J Cardiol. 2008, 126: 258-267. 10.1016/j.ijcard.2006.12.093.CrossRefPubMed Bombardini T, Galderisi M, Agricola E, et al: Negative stress echo: further prognostic stratification with assessment of pressure-volume relation. Int J Cardiol. 2008, 126: 258-267. 10.1016/j.ijcard.2006.12.093.CrossRefPubMed
12.
go back to reference Bombardini T, Agrusta M, Natsvlishvili N, et al: Noninvasive assessment of left ventricular contractility by pacemaker stress echocardiography. Eur J Heart Fail. 2005, 2: 173-181.CrossRef Bombardini T, Agrusta M, Natsvlishvili N, et al: Noninvasive assessment of left ventricular contractility by pacemaker stress echocardiography. Eur J Heart Fail. 2005, 2: 173-181.CrossRef
13.
go back to reference Grosu A, Bombardini T, Senni M, et al: End-systolic pressure/volume relations during dobutamine stress echo: a prognostically useful noninvasive index of left ventricular contractility. Eur Heart J. 2005, 26: 2404-2412. 10.1093/eurheartj/ehi444.CrossRefPubMed Grosu A, Bombardini T, Senni M, et al: End-systolic pressure/volume relations during dobutamine stress echo: a prognostically useful noninvasive index of left ventricular contractility. Eur Heart J. 2005, 26: 2404-2412. 10.1093/eurheartj/ehi444.CrossRefPubMed
14.
go back to reference Francis GS, Greenberg BH, Hsu DT, Jaski BE, Jessup M, LeWinter MM, Pagani FD, Piña IL, Semigran MJ, Walsh MN, Wiener DH, Yancy CW: ACCF/AHA/ACP/HFSA/ISHLT 2010 clinical competence statement on management of patients with advanced heart failure and cardiac transplant: a report of the ACCF/AHA/ACP Task Force on Clinical Competence and Training. J Am Coll Cardiol. 2010, 56: 424-53. 10.1016/j.jacc.2010.04.014.CrossRefPubMed Francis GS, Greenberg BH, Hsu DT, Jaski BE, Jessup M, LeWinter MM, Pagani FD, Piña IL, Semigran MJ, Walsh MN, Wiener DH, Yancy CW: ACCF/AHA/ACP/HFSA/ISHLT 2010 clinical competence statement on management of patients with advanced heart failure and cardiac transplant: a report of the ACCF/AHA/ACP Task Force on Clinical Competence and Training. J Am Coll Cardiol. 2010, 56: 424-53. 10.1016/j.jacc.2010.04.014.CrossRefPubMed
15.
go back to reference Ware JE, Kosinkski M, Gandek B: SF–36. Health survey: manual and interpretation guide. 2000, Lincoln, RI: Quality Metric, Inc Ware JE, Kosinkski M, Gandek B: SF–36. Health survey: manual and interpretation guide. 2000, Lincoln, RI: Quality Metric, Inc
16.
go back to reference Kugler C, Malehsa D, Tegtbur U, et al: Health-related quality of life and exercise tolerance in recipients of heart transplants and left ventricular assist devices: a prospective, comparative study. J Heart Lung Transplant. 2011, 30: 204-210. 10.1016/j.healun.2010.08.030.CrossRefPubMed Kugler C, Malehsa D, Tegtbur U, et al: Health-related quality of life and exercise tolerance in recipients of heart transplants and left ventricular assist devices: a prospective, comparative study. J Heart Lung Transplant. 2011, 30: 204-210. 10.1016/j.healun.2010.08.030.CrossRefPubMed
17.
go back to reference Apolone G, Mosconi P: The Italian SF-36 health survey: translation, validation and norming. J Clin Epidemiol. 1998, 11: 1025-1036.CrossRef Apolone G, Mosconi P: The Italian SF-36 health survey: translation, validation and norming. J Clin Epidemiol. 1998, 11: 1025-1036.CrossRef
18.
go back to reference Sicari R, Nihoyannopoulos P, Evangelista A, et al: Stress echocardiography expert consensus statement European Association of Echocardiography (EAE) (a registered branch of the ESC). Eur J Echocardiogr. 2008, 9: 415-437.CrossRefPubMed Sicari R, Nihoyannopoulos P, Evangelista A, et al: Stress echocardiography expert consensus statement European Association of Echocardiography (EAE) (a registered branch of the ESC). Eur J Echocardiogr. 2008, 9: 415-437.CrossRefPubMed
19.
20.
go back to reference Knollmann FD, Bocksch W, Spiegelsberger S, et al: Electron-beam computed tomography in the assessment of coronary artery disease after heart transplantation. Circulation. 2000, 101: 2078-2082. 10.1161/01.CIR.101.17.2078.CrossRefPubMed Knollmann FD, Bocksch W, Spiegelsberger S, et al: Electron-beam computed tomography in the assessment of coronary artery disease after heart transplantation. Circulation. 2000, 101: 2078-2082. 10.1161/01.CIR.101.17.2078.CrossRefPubMed
21.
go back to reference von Ziegler F, Leber AW, Becker A, et al: Detection of significant coronary artery stenosis with 64-slice computed tomography in heart transplant recipients: a comparative study with conventional coronary angiography. Int J Cardiovasc Imaging. 2009, 25: 91-100. 10.1007/s10554-008-9343-z.CrossRefPubMed von Ziegler F, Leber AW, Becker A, et al: Detection of significant coronary artery stenosis with 64-slice computed tomography in heart transplant recipients: a comparative study with conventional coronary angiography. Int J Cardiovasc Imaging. 2009, 25: 91-100. 10.1007/s10554-008-9343-z.CrossRefPubMed
22.
go back to reference The international society of heart and lung transplantation guidelines for the care of heart transplant recipients: TASK FORCE 3: long-term care of heart transplant recipients. J Heart Lung Transpl. 2010, 29 (8): 914-956. 10.1016/j.healun.2010.05.034.CrossRef The international society of heart and lung transplantation guidelines for the care of heart transplant recipients: TASK FORCE 3: long-term care of heart transplant recipients. J Heart Lung Transpl. 2010, 29 (8): 914-956. 10.1016/j.healun.2010.05.034.CrossRef
Metadata
Title
The pressure/volume relationship during dobutamine stress echocardiography in transplanted heart: comparison with quality of life and coronary anatomy
Authors
Giovanni Minardi
Giordano Zampi
Amedeo Pergolini
Giovanni Pulignano
Massimiliano Scappaticci
Francesca Moschella Orsini
Gaetano Pero
Paola Lilla Della Monica
Giovanni Cioffi
Francesco Musumeci
Publication date
01-12-2012
Publisher
BioMed Central
Published in
Cardiovascular Ultrasound / Issue 1/2012
Electronic ISSN: 1476-7120
DOI
https://doi.org/10.1186/1476-7120-10-44

Other articles of this Issue 1/2012

Cardiovascular Ultrasound 1/2012 Go to the issue