Abstract

Background

The purpose of this study was to determine the cut-off values of Hounsfield units (HU) for the discrimination of plaque components and to evaluate the feasibility of measurement of the volume of plaque components using multi-detector row computed tomography (MDCT).

Methods

Coronary lesions (125 lesions in 125 patients) were visualized by both integrated backscatter intravascular ultrasound (IB-IVUS) and 64-slice MDCT at the same site. The IB values were used as a gold standard to determine the cut off values of HU for the discrimination of plaque components.

Results

Plaques were classified as lipid pool (n =50), fibrosis (n =65) or calcification (n =35) by IB-IVUS. The HU of lipid pool, fibrosis and calcification were 18 ± 18 HU (−19 to 58 HU), 95 ± 24 HU (46 to 154 HU) and 378 ± 99 HU (188 to 605 HU), respectively. Using receiver operating characteristic curve analysis, a threshold of 50 HU was the optimal cutoff values to discriminate lipid pool from fibrosis. Lipid volume measured by MDCT was correlated with that measured by IB-IVUS (r =0.66, p <0.001), whereas fibrous volume was not (r =0.21, p =0.059).

Conclusion

Lipid volume measured by MDCT was moderately correlated with that measured by IB-IVUS. MDCT may be useful for volumetric assessment of the lipid volume of coronary plaques, whereas the assessment of fibrosis volume was unstable.
Appendix
Available only for authorised users
Literature
1.
go back to reference Ehara M, Surmely JF, Kawai M, Katoh O, Matsubara T, Terashima M, Tsuchikane E, Kinoshita Y, Suzuki T, Ito T, Takeda Y, Nasu K, Tanaka N, Murata A, Suzuki Y, Sato K, Suzuki T: Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography. Circ J. 2006, 70: 564-571. 10.1253/circj.70.564CrossRefPubMed Ehara M, Surmely JF, Kawai M, Katoh O, Matsubara T, Terashima M, Tsuchikane E, Kinoshita Y, Suzuki T, Ito T, Takeda Y, Nasu K, Tanaka N, Murata A, Suzuki Y, Sato K, Suzuki T: Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography. Circ J. 2006, 70: 564-571. 10.1253/circj.70.564CrossRefPubMed
2.
go back to reference Hoffmann U, Moselewski F, Cury RC, Ferencik M, Jang IK, Diaz LJ, Abbara S, Brady TJ, Achenbach S: Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease: patient-versus segment-based analysis. Circulation. 2004, 110: 2638-2643. 10.1161/01.CIR.0000145614.07427.9FCrossRefPubMed Hoffmann U, Moselewski F, Cury RC, Ferencik M, Jang IK, Diaz LJ, Abbara S, Brady TJ, Achenbach S: Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease: patient-versus segment-based analysis. Circulation. 2004, 110: 2638-2643. 10.1161/01.CIR.0000145614.07427.9FCrossRefPubMed
3.
go back to reference Moselewski F, Ropers D, Pohle K, Hoffmann U, Ferencik M, Chan RC, Cury RC, Abbara S, Jang IK, Brady TJ, Daniel WG, Achenbach S: Measurement of cross-sectional coronary atherosclerotic plaques and vessel area by 16-slice multi-detector CT: Comparison to IVUS. Am J Cardiol. 2004, 94: 1294-1297. 10.1016/j.amjcard.2004.07.117CrossRefPubMed Moselewski F, Ropers D, Pohle K, Hoffmann U, Ferencik M, Chan RC, Cury RC, Abbara S, Jang IK, Brady TJ, Daniel WG, Achenbach S: Measurement of cross-sectional coronary atherosclerotic plaques and vessel area by 16-slice multi-detector CT: Comparison to IVUS. Am J Cardiol. 2004, 94: 1294-1297. 10.1016/j.amjcard.2004.07.117CrossRefPubMed
4.
go back to reference Hoffmann U, Moselewski F, Nieman K, Jang IK, Ferencik M, Rahman AM, Cury RC, Abbara S, Joneidi-Jafari H, Achenbach S, Brady TJ: Noninvasive assessment of plaque morphology and composition in culprit and stable lesions in acute coronary syndrome and stable lesions in stable angina by multidetector computed tomography. J Am Coll Cardiol. 2006, 47: 1655-1662. 10.1016/j.jacc.2006.01.041CrossRefPubMed Hoffmann U, Moselewski F, Nieman K, Jang IK, Ferencik M, Rahman AM, Cury RC, Abbara S, Joneidi-Jafari H, Achenbach S, Brady TJ: Noninvasive assessment of plaque morphology and composition in culprit and stable lesions in acute coronary syndrome and stable lesions in stable angina by multidetector computed tomography. J Am Coll Cardiol. 2006, 47: 1655-1662. 10.1016/j.jacc.2006.01.041CrossRefPubMed
5.
go back to reference Motoyama S, Anno H, Sarai M, Sato T, Sanda Y, Ozaki Y, Mochizuki T, Katada K, Hishida H: Noninvasive coronary angiography with a prototype 256-row area detector computed tomography system: comparison with conventional invasive coronary angiography. J Am Coll Cardiol. 2008, 51: 773-775. 10.1016/j.jacc.2007.09.062CrossRefPubMed Motoyama S, Anno H, Sarai M, Sato T, Sanda Y, Ozaki Y, Mochizuki T, Katada K, Hishida H: Noninvasive coronary angiography with a prototype 256-row area detector computed tomography system: comparison with conventional invasive coronary angiography. J Am Coll Cardiol. 2008, 51: 773-775. 10.1016/j.jacc.2007.09.062CrossRefPubMed
6.
go back to reference Toepker M, Schlett CL, Irlbeck T, Mahabadi AA, Bamberg F, Leidecker C, Donnelly P, Hoffmann U: Accuracy of dual-source computed tomography in quantitative assessment of low density coronary stenosis. a motion phantom study. Eur Radiol. 2010, 20: 542-548. 10.1007/s00330-009-1587-zCrossRefPubMed Toepker M, Schlett CL, Irlbeck T, Mahabadi AA, Bamberg F, Leidecker C, Donnelly P, Hoffmann U: Accuracy of dual-source computed tomography in quantitative assessment of low density coronary stenosis. a motion phantom study. Eur Radiol. 2010, 20: 542-548. 10.1007/s00330-009-1587-zCrossRefPubMed
7.
go back to reference Leber AW, Knez A, Becker A, Becker C, von Ziegler F, Nikolaou K, Rist C, Reiser M, White C, Steinbeck G, Boekstegers P: Accuracy of multidetector spiral computed tomography in idetifing and differentiating the composition of coronary atherosclerotic plaques. A comparative study with intracoronary ultrasound. J Am Coll Cardiol. 2004, 43: 1241-1247. 10.1016/j.jacc.2003.10.059CrossRefPubMed Leber AW, Knez A, Becker A, Becker C, von Ziegler F, Nikolaou K, Rist C, Reiser M, White C, Steinbeck G, Boekstegers P: Accuracy of multidetector spiral computed tomography in idetifing and differentiating the composition of coronary atherosclerotic plaques. A comparative study with intracoronary ultrasound. J Am Coll Cardiol. 2004, 43: 1241-1247. 10.1016/j.jacc.2003.10.059CrossRefPubMed
8.
go back to reference Komatsu S, Imai A, Kodama K: Multidetector row computed tomography may accurately estimate plaque vulnerability. Circ J. 2011, 74: 1515-1521.CrossRef Komatsu S, Imai A, Kodama K: Multidetector row computed tomography may accurately estimate plaque vulnerability. Circ J. 2011, 74: 1515-1521.CrossRef
9.
go back to reference Pohle K, Achenbach S, MacNeill B, Ropers D, Ferencik M, Moselewski F, Hoffmann U, Brady TJ, Jang IK, Daniel WG: Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT: Comparison to IVUS. Atherosclerosis. 2006, 190: 174-180.CrossRefPubMed Pohle K, Achenbach S, MacNeill B, Ropers D, Ferencik M, Moselewski F, Hoffmann U, Brady TJ, Jang IK, Daniel WG: Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT: Comparison to IVUS. Atherosclerosis. 2006, 190: 174-180.CrossRefPubMed
10.
go back to reference Higashi M: Noninvasive assessment of coronary plaque using multidetector row computed tomography. Does MDCT accurately estimate plaque vulnerability? (Con). Circ J. 2011, 75: 1522-1528. 10.1253/circj.CJ-11-0313CrossRefPubMed Higashi M: Noninvasive assessment of coronary plaque using multidetector row computed tomography. Does MDCT accurately estimate plaque vulnerability? (Con). Circ J. 2011, 75: 1522-1528. 10.1253/circj.CJ-11-0313CrossRefPubMed
11.
go back to reference Schaar JA, De Korte CL, Mastik F, Strijder C, Pasterkamp G, Boersma E, Serruys PW, Van Der Steen AF: Characterizing vulnerable plaque features with intravascular elastography. Circulation. 2003, 108: 2636-2641. 10.1161/01.CIR.0000097067.96619.1FCrossRefPubMed Schaar JA, De Korte CL, Mastik F, Strijder C, Pasterkamp G, Boersma E, Serruys PW, Van Der Steen AF: Characterizing vulnerable plaque features with intravascular elastography. Circulation. 2003, 108: 2636-2641. 10.1161/01.CIR.0000097067.96619.1FCrossRefPubMed
12.
go back to reference Nair A, Kuban BD, Tuzcu EM, Schoenhagen P, Nissen SE, Vince DG: Coronary plaque classification with intravascular ultrasound radiofrequency data analysis. Circulation. 2002, 106: 2200-2206. 10.1161/01.CIR.0000035654.18341.5ECrossRefPubMed Nair A, Kuban BD, Tuzcu EM, Schoenhagen P, Nissen SE, Vince DG: Coronary plaque classification with intravascular ultrasound radiofrequency data analysis. Circulation. 2002, 106: 2200-2206. 10.1161/01.CIR.0000035654.18341.5ECrossRefPubMed
13.
go back to reference Kawasaki M, Sano K, Okubo M, Yokoyama H, Ito Y, Murata I, Tsuchiya K, Minatoguchi S, Zhou X, Fujita H, Fujiwara H: Volumetric quantitative analysis of tissue characteristics of coronary plaques after statin therapy using three dimensional integrated backscatter intravascular ultrasound. J Am Coll Cardiol. 2005, 45: 1946-1953. 10.1016/j.jacc.2004.09.081CrossRefPubMed Kawasaki M, Sano K, Okubo M, Yokoyama H, Ito Y, Murata I, Tsuchiya K, Minatoguchi S, Zhou X, Fujita H, Fujiwara H: Volumetric quantitative analysis of tissue characteristics of coronary plaques after statin therapy using three dimensional integrated backscatter intravascular ultrasound. J Am Coll Cardiol. 2005, 45: 1946-1953. 10.1016/j.jacc.2004.09.081CrossRefPubMed
14.
go back to reference Kawasaki M, Takatsu H, Noda T, Sano K, Ito Y, Hayakawa K, Tsuchiya K, Arai M, Nishigaki K, Takemura G, Minatoguchi S, Fujiwara T, Fujiwara H: In vivo quantitative tissue characterization of human coronary arterial plaques by use of integrated backscatter intravascular ultrasound and comparison with angioscopic findings. Circulation. 2002, 105: 2487-2492. 10.1161/01.CIR.0000017200.47342.10CrossRefPubMed Kawasaki M, Takatsu H, Noda T, Sano K, Ito Y, Hayakawa K, Tsuchiya K, Arai M, Nishigaki K, Takemura G, Minatoguchi S, Fujiwara T, Fujiwara H: In vivo quantitative tissue characterization of human coronary arterial plaques by use of integrated backscatter intravascular ultrasound and comparison with angioscopic findings. Circulation. 2002, 105: 2487-2492. 10.1161/01.CIR.0000017200.47342.10CrossRefPubMed
15.
go back to reference Sano K, Kawasaki M, Ishihara Y, Okubo M, Tsuchiya K, Nishigaki K, Zhou X, Minatoguchi S, Fujita H, Fujiwara H: Assessment of vulnerable plaques causing acute coronary syndrome using integrated backscatter intravascular ultrasound. J Am Coll Cardiol. 2006, 47: 734-741. 10.1016/j.jacc.2005.09.061CrossRefPubMed Sano K, Kawasaki M, Ishihara Y, Okubo M, Tsuchiya K, Nishigaki K, Zhou X, Minatoguchi S, Fujita H, Fujiwara H: Assessment of vulnerable plaques causing acute coronary syndrome using integrated backscatter intravascular ultrasound. J Am Coll Cardiol. 2006, 47: 734-741. 10.1016/j.jacc.2005.09.061CrossRefPubMed
16.
go back to reference Okubo M, Kawasaki M, Ishihara Y, Takeyama U, Kubota T, Yamaki T, Ojio S, Nishigaki K, Takemura G, Saio M, Takami T, Minatoguchi S, Fujiwara H: Development of integrated backscatter intravascular ultrasound for tissue characterization of coronary plaques. Ultrasound Med Biol. 2008, 34: 655-663. 10.1016/j.ultrasmedbio.2007.09.015CrossRefPubMed Okubo M, Kawasaki M, Ishihara Y, Takeyama U, Kubota T, Yamaki T, Ojio S, Nishigaki K, Takemura G, Saio M, Takami T, Minatoguchi S, Fujiwara H: Development of integrated backscatter intravascular ultrasound for tissue characterization of coronary plaques. Ultrasound Med Biol. 2008, 34: 655-663. 10.1016/j.ultrasmedbio.2007.09.015CrossRefPubMed
17.
go back to reference Okubo M, Kawasaki M, Ishihara Y, Takeyama U, Yasuda S, Kubota T, Tanaka S, Yamaki T, Ojio S, Nishigaki K, Takemura G, Saio M, Takami T, Fujiwara H: Tissue characterization of coronary plaques. Comparison of integrated backscatter intravascular ultrasound with Virtual Histology intravascular ultrasound. Circ J. 2008, 72: 1631-1639.PubMed Okubo M, Kawasaki M, Ishihara Y, Takeyama U, Yasuda S, Kubota T, Tanaka S, Yamaki T, Ojio S, Nishigaki K, Takemura G, Saio M, Takami T, Fujiwara H: Tissue characterization of coronary plaques. Comparison of integrated backscatter intravascular ultrasound with Virtual Histology intravascular ultrasound. Circ J. 2008, 72: 1631-1639.PubMed
18.
go back to reference Pencina MJ, D'Agostino RB, D'Agostino RB, Vasan RS: Evaluating the added predictive ability of a new marker: from area under the ROC curve to reclassification and beyond. Stat Med. 2008, 27: 157-172. 10.1002/sim.2929CrossRefPubMed Pencina MJ, D'Agostino RB, D'Agostino RB, Vasan RS: Evaluating the added predictive ability of a new marker: from area under the ROC curve to reclassification and beyond. Stat Med. 2008, 27: 157-172. 10.1002/sim.2929CrossRefPubMed
19.
go back to reference Motoyama S, Kondo T, Anno H, Sugiura A, Ito Y, Mori K, Ishii J, Sato T, Inoue K, Sarai M, Hishida H, Narula J: Atherosclerotic plaque characterization by 0.5-mm-slice multislice computed tomographic imaging. Circ J. 2007, 71: 363-366. 10.1253/circj.71.363CrossRefPubMed Motoyama S, Kondo T, Anno H, Sugiura A, Ito Y, Mori K, Ishii J, Sato T, Inoue K, Sarai M, Hishida H, Narula J: Atherosclerotic plaque characterization by 0.5-mm-slice multislice computed tomographic imaging. Circ J. 2007, 71: 363-366. 10.1253/circj.71.363CrossRefPubMed
20.
go back to reference Schroeder S, Kopp AF, Baumbach A, Meisner C, Kuettner A, Georg C, Ohnesorge B, Herdeg C, Claussen CD, Karsch KR: Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography. J Am Coll Cardiol. 2001, 37: 1430-1435. 10.1016/S0735-1097(01)01115-9CrossRefPubMed Schroeder S, Kopp AF, Baumbach A, Meisner C, Kuettner A, Georg C, Ohnesorge B, Herdeg C, Claussen CD, Karsch KR: Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography. J Am Coll Cardiol. 2001, 37: 1430-1435. 10.1016/S0735-1097(01)01115-9CrossRefPubMed
21.
go back to reference Kitagawa T, Yamamoto H, Ohhashi N, Okimoto T, Horiguchi J, Hirai N, Ito K, Kohno N: Comprehensive evaluation of noncalcified coronary plaque characteristics detected using 64-slice computed tomography in patients with proven or suspected coronary artery disease. Am Heart J. 2007, 154: 1191-1198. 10.1016/j.ahj.2007.07.020CrossRefPubMed Kitagawa T, Yamamoto H, Ohhashi N, Okimoto T, Horiguchi J, Hirai N, Ito K, Kohno N: Comprehensive evaluation of noncalcified coronary plaque characteristics detected using 64-slice computed tomography in patients with proven or suspected coronary artery disease. Am Heart J. 2007, 154: 1191-1198. 10.1016/j.ahj.2007.07.020CrossRefPubMed
22.
go back to reference Chopard R, Boussel L, Motreff P, Rioufol G, Tabib A, Douek P, Meyronet D, Revel D, Finet G: How reliable are 40 MHz IVUS and 64-slice MDCT in characterizing coronary plaque composition? An ex vivo study with histopathological comparison. Int J Cardiovasc Imaging. 2010, 26: 373-383. 10.1007/s10554-009-9562-yCrossRefPubMed Chopard R, Boussel L, Motreff P, Rioufol G, Tabib A, Douek P, Meyronet D, Revel D, Finet G: How reliable are 40 MHz IVUS and 64-slice MDCT in characterizing coronary plaque composition? An ex vivo study with histopathological comparison. Int J Cardiovasc Imaging. 2010, 26: 373-383. 10.1007/s10554-009-9562-yCrossRefPubMed
23.
go back to reference Harada K, Amano T, Uetani T, Funahashi H, Arai K, Okada K, Hirashiki A, Hayashi M, Oshima S, Ishii H, Izawa H, Matsubara T, Murohara T: Accuracy of 64-slice multidetector computed tomography for classification and quantitation of coronary plaque: Comparison with integrated backscatter intravascular ultrasound. Int J Cardiol. 2011, 149: 95-101. 10.1016/j.ijcard.2010.04.002CrossRefPubMed Harada K, Amano T, Uetani T, Funahashi H, Arai K, Okada K, Hirashiki A, Hayashi M, Oshima S, Ishii H, Izawa H, Matsubara T, Murohara T: Accuracy of 64-slice multidetector computed tomography for classification and quantitation of coronary plaque: Comparison with integrated backscatter intravascular ultrasound. Int J Cardiol. 2011, 149: 95-101. 10.1016/j.ijcard.2010.04.002CrossRefPubMed
24.
go back to reference Tanaka A, Shimada K, Yoshida K, Jissyo S, Tanaka H, Sakamoto M, Matsuba K, Imanishi T, Akasaka T, Yoshikawa J: Non-invasive assessment of plaque rupture by 64-slice multidetector computed tomography-comparison with intravascular ultrasound. Circ J. 2008, 72: 1276-1281. 10.1253/circj.72.1276CrossRefPubMed Tanaka A, Shimada K, Yoshida K, Jissyo S, Tanaka H, Sakamoto M, Matsuba K, Imanishi T, Akasaka T, Yoshikawa J: Non-invasive assessment of plaque rupture by 64-slice multidetector computed tomography-comparison with intravascular ultrasound. Circ J. 2008, 72: 1276-1281. 10.1253/circj.72.1276CrossRefPubMed
25.
go back to reference Cademartiri F, Runza G, Mollet NR, Luccichenti G, Belgrano M, Somers P, Knaapen M, Verheye S, Bruining N, Hamers R, Midiri M, De Feyter PJ, Krestin GP: Influence of increasing convolution kernel filtering on plaque imaging with multislice CT using an ex-vivo model of coronary angiography. Radiol Med. 2005, 110: 234-240.PubMed Cademartiri F, Runza G, Mollet NR, Luccichenti G, Belgrano M, Somers P, Knaapen M, Verheye S, Bruining N, Hamers R, Midiri M, De Feyter PJ, Krestin GP: Influence of increasing convolution kernel filtering on plaque imaging with multislice CT using an ex-vivo model of coronary angiography. Radiol Med. 2005, 110: 234-240.PubMed
26.
go back to reference Stary HC, Chandler AB, Dinsmore RE, Fuster V, Glagov S, Insull W, Rosenfeld ME, Schwartz CJ, Wagner WD, Wissler RW: A definition of advanced types of atherosclerotic lesions and a histological classification of atherosclerosis. A report from the Committee on Vascular Lesions of the Council on Arteriosclerosis, American Heart Association. Circulation. 1995, 92: 1355-1374. 10.1161/01.CIR.92.5.1355CrossRefPubMed Stary HC, Chandler AB, Dinsmore RE, Fuster V, Glagov S, Insull W, Rosenfeld ME, Schwartz CJ, Wagner WD, Wissler RW: A definition of advanced types of atherosclerotic lesions and a histological classification of atherosclerosis. A report from the Committee on Vascular Lesions of the Council on Arteriosclerosis, American Heart Association. Circulation. 1995, 92: 1355-1374. 10.1161/01.CIR.92.5.1355CrossRefPubMed
27.
go back to reference Motoyama S, Kondo T, Sarai M, Sugiura A, Harigaya H, Sato T, Inoue K, Okumura M, Ishii J, Anno H, Virmani R, Ozaki Y, Hishida H, Narula J: Multislice computed tomographic characteristics of coronary lesions in acute coronary syndromes. J Am Coll Cardiol. 2007, 50: 319-326. 10.1016/j.jacc.2007.03.044CrossRefPubMed Motoyama S, Kondo T, Sarai M, Sugiura A, Harigaya H, Sato T, Inoue K, Okumura M, Ishii J, Anno H, Virmani R, Ozaki Y, Hishida H, Narula J: Multislice computed tomographic characteristics of coronary lesions in acute coronary syndromes. J Am Coll Cardiol. 2007, 50: 319-326. 10.1016/j.jacc.2007.03.044CrossRefPubMed
28.
go back to reference Kashiwagi M, Tanaka A, Kitabata H, Tsujioka H, Kataiwa H, Komukai K, Tanimoto T, Takemoto K, Takarada S, Kubo T, Hirata K, Nakamura N, Mizukoshi M, Imanishi T, Akasaka T: Feasibility of non-invasive assessment of thin-cap fibroatheroma by multidetector computed tomography. JACC Cardiovasc Imaging. 2009, 12: 1412-1419.CrossRef Kashiwagi M, Tanaka A, Kitabata H, Tsujioka H, Kataiwa H, Komukai K, Tanimoto T, Takemoto K, Takarada S, Kubo T, Hirata K, Nakamura N, Mizukoshi M, Imanishi T, Akasaka T: Feasibility of non-invasive assessment of thin-cap fibroatheroma by multidetector computed tomography. JACC Cardiovasc Imaging. 2009, 12: 1412-1419.CrossRef
29.
go back to reference Cademartiri F, Mollet NR, Runza G, Bruining N, Hamers R, Somers P, Knaapen M, Verheye S, Midiri M, Krestin GP, de Feyter PJ: Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: Observations in an ex vivo model of coronary computed tomography angiography. Eur Radiol. 2005, 15: 1426-1431. 10.1007/s00330-005-2697-xCrossRefPubMed Cademartiri F, Mollet NR, Runza G, Bruining N, Hamers R, Somers P, Knaapen M, Verheye S, Midiri M, Krestin GP, de Feyter PJ: Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: Observations in an ex vivo model of coronary computed tomography angiography. Eur Radiol. 2005, 15: 1426-1431. 10.1007/s00330-005-2697-xCrossRefPubMed
30.
go back to reference Halliburton SS, Schoenhagen P, Nair A, Stillman A, Lieber M: Murat Tuzcu E, Geoffrey Vince D, White RD: Contrast enhancement of coronary atherosclerotic plaque: a high-resolution, multidetector-row computed tomography study of pressure-perfused, human ex-vivo coronary arteries. Coron Artery Dis. 2006, 176: 553-560.CrossRef Halliburton SS, Schoenhagen P, Nair A, Stillman A, Lieber M: Murat Tuzcu E, Geoffrey Vince D, White RD: Contrast enhancement of coronary atherosclerotic plaque: a high-resolution, multidetector-row computed tomography study of pressure-perfused, human ex-vivo coronary arteries. Coron Artery Dis. 2006, 176: 553-560.CrossRef
31.
go back to reference Taylor AJ, Burke AP, O'Malley PG, Farb A, Malcom GT, Smialek J, Virmani R: A Comparison of the Framingham Risk Index, Coronary Artery Calcification, and Culprit Plaque Morphology in Sudden Cardiac Death. Circulation. 2000, 101: 1243-1248. 10.1161/01.CIR.101.11.1243CrossRefPubMed Taylor AJ, Burke AP, O'Malley PG, Farb A, Malcom GT, Smialek J, Virmani R: A Comparison of the Framingham Risk Index, Coronary Artery Calcification, and Culprit Plaque Morphology in Sudden Cardiac Death. Circulation. 2000, 101: 1243-1248. 10.1161/01.CIR.101.11.1243CrossRefPubMed
Metadata
Title
Comparison between integrated backscatter intravascular ultrasound and 64-slice multi-detector row computed tomography for tissue characterization and volumetric assessment of coronary plaques
Authors
Takahiko Yamaki
Masanori Kawasaki
Ik-Kyung Jang
Owen Christopher Raffel
Yoshiyuki Ishihara
Munenori Okubo
Tomoki Kubota
Arihiro Hattori
Kazuhiko Nishigaki
Genzou Takemura
Hisayoshi Fujiwara
Shinya Minatoguchi
Publication date
01-12-2012
Publisher
BioMed Central
Published in
Cardiovascular Ultrasound / Issue 1/2012
Electronic ISSN: 1476-7120
DOI
https://doi.org/10.1186/1476-7120-10-33

Other articles of this Issue 1/2012

Cardiovascular Ultrasound 1/2012 Go to the issue