Abstract

Background

Inaccurate malaria results can lead to patient mismanagement, misperceptions about malaria resistance patterns and public health misinformation. All laboratories need to be able to demonstrate that their results are accurate. Establishing and maintaining a system for monitoring test accuracy is a complex, expensive and technically demanding process, which very few poor countries have been able to implement. This study described the process and assessed the feasibility of establishing a nation-wide system for improving the accuracy of malaria-related tests in peripheral laboratories in Ghana.

Programme implementation

A baseline survey of all 693 laboratory staff in 205 sub-regional government and mission health laboratories in Ghana was conducted by a national network of laboratory supervisors. Survey results guided a training programme to improve test accuracy. Outcomes included changes in the quality of laboratory tests and the system was considered to be feasible if >50% of laboratory staff in each region received training and if test accuracy could be documented.

Programme indicators

74% (mean) of the 693 laboratory staff were assistants with no professional qualifications. There were marked differences between regions in the availability of essential resources for malaria diagnosis (e.g. microscopes). 93% of laboratory staff received training; in six months there were increases of 11% and 7% respectively in the number of laboratories producing haemoglobin and malaria microscopy results of acceptable quality.

Conclusions

It is possible to establish a system for improving and monitoring test accuracy in peripheral laboratories on a country-wide basis in a developing country using a model that could be adapted for use in other countries and for other components of health care provision.
Literature
2.
go back to reference World Health Organization: Quality Systems for Medical Laboratories. 1995, Alexandria, Egypt: WHO, 1 World Health Organization: Quality Systems for Medical Laboratories. 1995, Alexandria, Egypt: WHO, 1
3.
go back to reference Ghana health statistics: 1998, Statistical Service, Ghana Ghana health statistics: 1998, Statistical Service, Ghana
4.
go back to reference Ministry of Health, Government of Ghana: Health Sector Programme of Work 1997–2001. 1996 Ministry of Health, Government of Ghana: Health Sector Programme of Work 1997–2001. 1996
5.
go back to reference World Health Organization: Safety in health care laboratories. 1997, Geneva. WHO/LAB.97.1 World Health Organization: Safety in health care laboratories. 1997, Geneva. WHO/LAB.97.1
6.
go back to reference Public Health and Reference Laboratory Ministry of Health, Ghana: Standard Laboratory Operating Procedures. 1998 Public Health and Reference Laboratory Ministry of Health, Ghana: Standard Laboratory Operating Procedures. 1998
7.
go back to reference Mundy C, Bates I, Nkhoma W, Floyd K, Kadewele G, Ngwira M, Khuwi A, Squire SB, Gilks CF: The operation, quality and costs of a district hospital laboratory service in Malawi. Trans R Soc Trop Med Hyg. 2003, 97: 403-408. 10.1016/S0035-9203(03)90070-8.CrossRefPubMed Mundy C, Bates I, Nkhoma W, Floyd K, Kadewele G, Ngwira M, Khuwi A, Squire SB, Gilks CF: The operation, quality and costs of a district hospital laboratory service in Malawi. Trans R Soc Trop Med Hyg. 2003, 97: 403-408. 10.1016/S0035-9203(03)90070-8.CrossRefPubMed
Metadata
Title
Improving the accuracy of malaria-related laboratory tests in Ghana
Authors
Imelda Bates
Veronica Bekoe
Alex Asamoa-Adu
Publication date
01-12-2004
Publisher
BioMed Central
Published in
Malaria Journal / Issue 1/2004
Electronic ISSN: 1475-2875
DOI
https://doi.org/10.1186/1475-2875-3-38

Other articles of this Issue 1/2004

Malaria Journal 1/2004 Go to the issue
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.