Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2013

Open Access 01-12-2013 | Research article

Effects of cord pretension and stiffness of the Dynesys system spacer on the biomechanics of spinal decompression- a finite element study

Authors: Shih-Liang Shih, Chien-Lin Liu, Li-Ying Huang, Chang-Hung Huang, Chen-Sheng Chen

Published in: BMC Musculoskeletal Disorders | Issue 1/2013

Login to get access

Abstract

Background

The Dynesys system provides stability for destabilized spines while preserving segmental motion. However, clinical studies have demonstrated that the Dynesys system does not prevent adjacent segment disease. Moreover, biomechanical studies have revealed that the stiffness of the Dynesys system is comparable to rigid fixation. Our previous studies showed that adjusting the cord pretension of the Dynesys system alleviates stress on the adjacent level during flexion. We also demonstrated that altering the stiffness of Dynesys system spacers can alleviate stress on the adjacent level during extension of the intact spine. In the present study, we hypothesized that omitting the cord preload and changing the stiffness of the Dynesys system spacers would abate stress shielding on adjacent spinal segments.

Methods

Finite element models were developed for - intact spine (INT), facetectomy and laminectomy at L3-4 (DEC), intact spine with Dynesys system (IntDyWL), decompressed spine with Dynesys system (DecDyWL), decompressed spine with Dynesys system without cord preload (DecDyNL), and decompressed spine with Dynesys system assembled using spacers that were 0.8 times the standard diameter without cord pretension (DecDyNL0.8). These models were subjected to hybrid control for flexion, extension, axial rotation; and lateral bending.

Results

The greatest decreases in range of motion (ROM) at the L3-4 level occurred for axial rotation and lateral bending in the IntDyWL model and for flexion and extension in the DecDyWL model. The greatest decreases in disc stress occurred for extension and lateral bending in the IntDyWL model and for flexion in the DecDyWL model. The greatest decreases in facet contact force occurred for extension and lateral bending in the DecDyNL model and for axial rotation in the DecDyWL model. The greatest increases in ROMs at L2-3 level occurred for flexion, axial rotation and lateral bending in IntDyWL model and for extension in the DecDyNL model. The greatest increases in disc stress occurred for flexion, axial rotation and lateral bending in the IntDyWL model and for extension in the DecDyNL model. The greatest increases in facet contact force occurred for extension and lateral bending in the DecDyNL model and for axial rotation in the IntDyWL model.

Conclusions

The results reveals that removing the Dynesys system cord pretension attenuates the ROMs, disc stress, and facet joint contact forces at adjacent levels during flexion and axial rotation. Removing cord pretension together with softening spacers abates stress shielding for adjacent segment during four different moments, and it provides enough security while not jeopardizes the stability of spine during axial rotation.
Appendix
Available only for authorised users
Literature
1.
go back to reference Bridwell KH, Sedgewick TA, O’Brien MF, Lenke LG, Baldus C: The role of fusion and instrumentation in the treatment of degenerative spondylolisthesis with spinal stenosis. J Spinal Disord Tech. 1993, 6 (6): 461-472. 10.1097/00002517-199306060-00001.CrossRef Bridwell KH, Sedgewick TA, O’Brien MF, Lenke LG, Baldus C: The role of fusion and instrumentation in the treatment of degenerative spondylolisthesis with spinal stenosis. J Spinal Disord Tech. 1993, 6 (6): 461-472. 10.1097/00002517-199306060-00001.CrossRef
2.
go back to reference Lee CK: Lumbar spinal instability (olisthesis) after extensive posterior spinal decompression. Spine. 1983, 8 (4): 429-433. 10.1097/00007632-198305000-00014.CrossRefPubMed Lee CK: Lumbar spinal instability (olisthesis) after extensive posterior spinal decompression. Spine. 1983, 8 (4): 429-433. 10.1097/00007632-198305000-00014.CrossRefPubMed
3.
go back to reference Johnsson KE, Willner S, Johnsson K: Postoperative instability after decompression for lumbar spinal stenosis. Spine. 1986, 11 (2): 107-110. 10.1097/00007632-198603000-00001.CrossRefPubMed Johnsson KE, Willner S, Johnsson K: Postoperative instability after decompression for lumbar spinal stenosis. Spine. 1986, 11 (2): 107-110. 10.1097/00007632-198603000-00001.CrossRefPubMed
4.
go back to reference Lee CK: Accelerated degeneration of the segment adjacent to a lumbar fusion. Spine. 1988, 13 (3): 375-377. 10.1097/00007632-198803000-00029.CrossRefPubMed Lee CK: Accelerated degeneration of the segment adjacent to a lumbar fusion. Spine. 1988, 13 (3): 375-377. 10.1097/00007632-198803000-00029.CrossRefPubMed
5.
go back to reference Park P, Garton HJ, Gala VC, Hoff JT, McGillicuddy JE: Adjacent segment disease after lumbar or lumbosacral fusion: review of the literature. Spine. 2004, 29 (17): 1938-1944. 10.1097/01.brs.0000137069.88904.03.CrossRefPubMed Park P, Garton HJ, Gala VC, Hoff JT, McGillicuddy JE: Adjacent segment disease after lumbar or lumbosacral fusion: review of the literature. Spine. 2004, 29 (17): 1938-1944. 10.1097/01.brs.0000137069.88904.03.CrossRefPubMed
6.
go back to reference Schulte TL, Hurschler C, Haversath M, Liljenqvist U, Bullmann V, Filler TJ, Osada N, Fallenberg EM, Hackenberg L: The effect of dynamic, semi-rigid implants on the range of motion of lumbar motion segments after decompression. Eur Spine J. 2008, 17 (8): 1057-1065. 10.1007/s00586-008-0667-0.CrossRefPubMedPubMedCentral Schulte TL, Hurschler C, Haversath M, Liljenqvist U, Bullmann V, Filler TJ, Osada N, Fallenberg EM, Hackenberg L: The effect of dynamic, semi-rigid implants on the range of motion of lumbar motion segments after decompression. Eur Spine J. 2008, 17 (8): 1057-1065. 10.1007/s00586-008-0667-0.CrossRefPubMedPubMedCentral
7.
go back to reference Mulholland RC, Sengupta DK: Rationale, principles and experimental evaluation of the concept of soft stabilization. Eur Spine J. 2002, 11 (2): S198-S205.PubMedPubMedCentral Mulholland RC, Sengupta DK: Rationale, principles and experimental evaluation of the concept of soft stabilization. Eur Spine J. 2002, 11 (2): S198-S205.PubMedPubMedCentral
8.
go back to reference Dubois G, de Germay B, Schaerer NS, Fennema P: Dynamic neutralization: a new concept for restabilization of the spine. Lumbar segmental instability. Edited by: Szalski M, Gunzburg R, Pope MH. 1999, Philadelphia: Lippincott Williams & Wilkins, 233-240. Dubois G, de Germay B, Schaerer NS, Fennema P: Dynamic neutralization: a new concept for restabilization of the spine. Lumbar segmental instability. Edited by: Szalski M, Gunzburg R, Pope MH. 1999, Philadelphia: Lippincott Williams & Wilkins, 233-240.
9.
go back to reference Schaeren S, Broger I, Jeanneret B: Minimum four-year follow-up of spinal stenosis with degenerative spondylolisthesis treated with decompression and dynamic stabilization. Spine. 2008, 33 (18): E636-E642. 10.1097/BRS.0b013e31817d2435.CrossRefPubMed Schaeren S, Broger I, Jeanneret B: Minimum four-year follow-up of spinal stenosis with degenerative spondylolisthesis treated with decompression and dynamic stabilization. Spine. 2008, 33 (18): E636-E642. 10.1097/BRS.0b013e31817d2435.CrossRefPubMed
10.
go back to reference Schnake KJ, Schaeren S, Jeanneret B: Dynamic stabilization in addition to decompression for lumbar spinal stenosis with degenerative spondylolisthesis. Spine. 2006, 31 (4): 442-449. 10.1097/01.brs.0000200092.49001.6e.CrossRefPubMed Schnake KJ, Schaeren S, Jeanneret B: Dynamic stabilization in addition to decompression for lumbar spinal stenosis with degenerative spondylolisthesis. Spine. 2006, 31 (4): 442-449. 10.1097/01.brs.0000200092.49001.6e.CrossRefPubMed
11.
go back to reference Silvestre MD, Lolli F, Bakaloudis G, Parisini P: Dynamic stabilization for degenerative lumbar scoliosis in elderly patients. Spine. 2010, 35 (2): 227-234. 10.1097/BRS.0b013e3181bd3be6.CrossRefPubMed Silvestre MD, Lolli F, Bakaloudis G, Parisini P: Dynamic stabilization for degenerative lumbar scoliosis in elderly patients. Spine. 2010, 35 (2): 227-234. 10.1097/BRS.0b013e3181bd3be6.CrossRefPubMed
12.
go back to reference Welch WC, Cheng BC, Awad TE, Davis R, Maxwell JH, Delamarter R, Wingate JK, Sherman J, Macenski MM: Clinical outcomes of the Dynesys dynamic neutralization system: 1-year preliminary results. Neurosurg Focus. 2007, 22 (1): E8-CrossRefPubMed Welch WC, Cheng BC, Awad TE, Davis R, Maxwell JH, Delamarter R, Wingate JK, Sherman J, Macenski MM: Clinical outcomes of the Dynesys dynamic neutralization system: 1-year preliminary results. Neurosurg Focus. 2007, 22 (1): E8-CrossRefPubMed
13.
go back to reference Wurgler-Hauri CC, Kalbarczyk A, Wiesli M, Landolt H, Fandino J: Dynamic neutralization of the lumbar spine after microsurgical decompression in acquired lumbar spinal stenosis and segmental instability. Spine. 2008, 33 (3): E66-E72. 10.1097/BRS.0b013e31816245c0.CrossRefPubMed Wurgler-Hauri CC, Kalbarczyk A, Wiesli M, Landolt H, Fandino J: Dynamic neutralization of the lumbar spine after microsurgical decompression in acquired lumbar spinal stenosis and segmental instability. Spine. 2008, 33 (3): E66-E72. 10.1097/BRS.0b013e31816245c0.CrossRefPubMed
14.
go back to reference Kumar A, Beastall J, Hughes J, Karadimas EJ, Nicol M, Smith F, Wardlaw D: Disc changes in the bridged and adjacent segments after Dynesys dynamic stabilization system after two years. Spine. 2008, 33 (26): 2909-2914. 10.1097/BRS.0b013e31818bdca7.CrossRefPubMed Kumar A, Beastall J, Hughes J, Karadimas EJ, Nicol M, Smith F, Wardlaw D: Disc changes in the bridged and adjacent segments after Dynesys dynamic stabilization system after two years. Spine. 2008, 33 (26): 2909-2914. 10.1097/BRS.0b013e31818bdca7.CrossRefPubMed
15.
go back to reference Cakir B, Carazzo C, Schmidt R, Mattes T, Reichel H, Kafer W: Adjacent segment mobility after rigid and semi-rigid instrumentation of the lumbar spine. Spine. 2009, 34 (12): 1287-1291. 10.1097/BRS.0b013e3181a136ab.CrossRefPubMed Cakir B, Carazzo C, Schmidt R, Mattes T, Reichel H, Kafer W: Adjacent segment mobility after rigid and semi-rigid instrumentation of the lumbar spine. Spine. 2009, 34 (12): 1287-1291. 10.1097/BRS.0b013e3181a136ab.CrossRefPubMed
16.
go back to reference Kim CH, Chung CK, Jahng TA: Comparisons of outcomes after single or multilevel dynamic stabilization: effects on adjacent segment. J Spinal Disord Tech. 2011, 24 (1): 60-67. 10.1097/BSD.0b013e3181d4eb44.CrossRefPubMed Kim CH, Chung CK, Jahng TA: Comparisons of outcomes after single or multilevel dynamic stabilization: effects on adjacent segment. J Spinal Disord Tech. 2011, 24 (1): 60-67. 10.1097/BSD.0b013e3181d4eb44.CrossRefPubMed
17.
go back to reference Castellvi A, Huang H, Vestgaarden T, Saigal S, Clabeaux DH, Pienkowski D: Stress reduction in adjacent level discs via dynamic instrumentation: a finite element analysis. SAS Journal. 2007, 1 (2): 74-81. 10.1016/S1935-9810(07)70050-6.CrossRefPubMedPubMedCentral Castellvi A, Huang H, Vestgaarden T, Saigal S, Clabeaux DH, Pienkowski D: Stress reduction in adjacent level discs via dynamic instrumentation: a finite element analysis. SAS Journal. 2007, 1 (2): 74-81. 10.1016/S1935-9810(07)70050-6.CrossRefPubMedPubMedCentral
18.
go back to reference Zander T, Rohlmann A, Burra NK, Bergmann G: Effect of a posterior dynamic implant adjacent to a rigid spinal fixator. Clin Biomech. 2006, 21 (8): 767-774. 10.1016/j.clinbiomech.2006.04.001.CrossRef Zander T, Rohlmann A, Burra NK, Bergmann G: Effect of a posterior dynamic implant adjacent to a rigid spinal fixator. Clin Biomech. 2006, 21 (8): 767-774. 10.1016/j.clinbiomech.2006.04.001.CrossRef
19.
go back to reference Strube P, Tohtz S, Hoff E, Gross C, Perka C, Putzier: Dynamic stabilization adjacent to single-level fusion. Part I. Biomechanical effects on lumbar spinal motion. Eur Spine J. 2010, 19 (12): 2171-2180. 10.1007/s00586-010-1549-9.CrossRefPubMedPubMedCentral Strube P, Tohtz S, Hoff E, Gross C, Perka C, Putzier: Dynamic stabilization adjacent to single-level fusion. Part I. Biomechanical effects on lumbar spinal motion. Eur Spine J. 2010, 19 (12): 2171-2180. 10.1007/s00586-010-1549-9.CrossRefPubMedPubMedCentral
20.
go back to reference Schmoelz W, Huber JF, Nydegger T, Claes L, Wilke HJ: Dynamic stabilization of the lumbar spine and its effects on adjacent segments: an in vitro experiment. J Spinal Disord Tech. 2003, 16 (4): 418-423. 10.1097/00024720-200308000-00015.CrossRefPubMed Schmoelz W, Huber JF, Nydegger T, Claes L, Wilke HJ: Dynamic stabilization of the lumbar spine and its effects on adjacent segments: an in vitro experiment. J Spinal Disord Tech. 2003, 16 (4): 418-423. 10.1097/00024720-200308000-00015.CrossRefPubMed
21.
go back to reference Shin DS, Lee K, Kim D: Biomechanical study of lumbar spine with dynamic stabilization device using finite element method. Computer-Aided Design. 2007, 39: 559-567. 10.1016/j.cad.2007.03.005.CrossRef Shin DS, Lee K, Kim D: Biomechanical study of lumbar spine with dynamic stabilization device using finite element method. Computer-Aided Design. 2007, 39: 559-567. 10.1016/j.cad.2007.03.005.CrossRef
22.
go back to reference Zhang QH, Teo EC: Effect of Dynamic stabilization device stiffness on disc loading under compression. IFMBE Proceedings. 2008, 19: 119-122. 10.1007/978-3-540-79039-6_32.CrossRef Zhang QH, Teo EC: Effect of Dynamic stabilization device stiffness on disc loading under compression. IFMBE Proceedings. 2008, 19: 119-122. 10.1007/978-3-540-79039-6_32.CrossRef
23.
go back to reference Liu CL, Zhong ZC, Hsu HW, Shih SL, Wang ST, Hung C, Chen CS: Effect of the cord pretension of the Dynesys dynamic stabilization system on the biomechanics of the lumbar spine. Eur Spine J. 2011, 20 (11): 1850-1858. 10.1007/s00586-011-1817-3.CrossRefPubMedPubMedCentral Liu CL, Zhong ZC, Hsu HW, Shih SL, Wang ST, Hung C, Chen CS: Effect of the cord pretension of the Dynesys dynamic stabilization system on the biomechanics of the lumbar spine. Eur Spine J. 2011, 20 (11): 1850-1858. 10.1007/s00586-011-1817-3.CrossRefPubMedPubMedCentral
24.
go back to reference Shih SL, Chen CS, Lin HM, Huang LY, Liu CL, Huang CH, Cheng CK: Effect of spacer diameter of the Dynesys dynamic stabilization system on the biomechanics of the lumbar spine: a finite element analysis. J Spinal Disord Tech. 2012, 25 (5): E140-E149.CrossRefPubMed Shih SL, Chen CS, Lin HM, Huang LY, Liu CL, Huang CH, Cheng CK: Effect of spacer diameter of the Dynesys dynamic stabilization system on the biomechanics of the lumbar spine: a finite element analysis. J Spinal Disord Tech. 2012, 25 (5): E140-E149.CrossRefPubMed
25.
go back to reference Zhong ZC, Chen SH, Hung C: Load- and displacement controlled finite element analyses on fusion and non-fusion spinal implants. Proc Inst Mech Eng H. 2009, 223 (2): 143-157. 10.1243/09544119JEIM476.CrossRefPubMed Zhong ZC, Chen SH, Hung C: Load- and displacement controlled finite element analyses on fusion and non-fusion spinal implants. Proc Inst Mech Eng H. 2009, 223 (2): 143-157. 10.1243/09544119JEIM476.CrossRefPubMed
26.
go back to reference Chen SH, Zhong ZC, Chen CS, Chen WJ, Hung C: Biomechanical comparison between lumbar disc arthroplasty and fusion. Med Eng Phys. 2009, 31 (2): 244-253. 10.1016/j.medengphy.2008.07.007.CrossRefPubMed Chen SH, Zhong ZC, Chen CS, Chen WJ, Hung C: Biomechanical comparison between lumbar disc arthroplasty and fusion. Med Eng Phys. 2009, 31 (2): 244-253. 10.1016/j.medengphy.2008.07.007.CrossRefPubMed
27.
go back to reference Liu CL, Zhong ZC, Shih SL, Hung C, Lee YE, Chen CS: Influence of Dynesys system screw profile on adjacent segment and screw. J Spinal Disord Tech. 2010, 23 (6): 410-417. 10.1097/BSD.0b013e3181b63d89.CrossRefPubMed Liu CL, Zhong ZC, Shih SL, Hung C, Lee YE, Chen CS: Influence of Dynesys system screw profile on adjacent segment and screw. J Spinal Disord Tech. 2010, 23 (6): 410-417. 10.1097/BSD.0b013e3181b63d89.CrossRefPubMed
28.
go back to reference Umehara S, Tadano S, Abumi K, Katagiri K, Kaneda K, Ukai T: Effects of degeneration on the elastic modulus distribution in the lumbar intervertebral disc. Spine. 1996, 21 (7): 811-819. 10.1097/00007632-199604010-00007.CrossRefPubMed Umehara S, Tadano S, Abumi K, Katagiri K, Kaneda K, Ukai T: Effects of degeneration on the elastic modulus distribution in the lumbar intervertebral disc. Spine. 1996, 21 (7): 811-819. 10.1097/00007632-199604010-00007.CrossRefPubMed
29.
go back to reference Rohlmann A, Zander T, Bergmann G: Effect of total disc replacement with ProDisc on the biomechanical behavior of the lumbar spine. Spine. 2005, 30 (7): 738-743. 10.1097/01.brs.0000157413.72276.c4.CrossRefPubMed Rohlmann A, Zander T, Bergmann G: Effect of total disc replacement with ProDisc on the biomechanical behavior of the lumbar spine. Spine. 2005, 30 (7): 738-743. 10.1097/01.brs.0000157413.72276.c4.CrossRefPubMed
30.
go back to reference Schmidt H, Heuer F, Simon U, Kettler A, Rohlmann A, Claes L, Wilke HJ: Application of a new calibration method for a three-dimensional finite element model of a human lumbar annulus fibrosus. Clin Biomech. 2006, 21 (4): 337-344. 10.1016/j.clinbiomech.2005.12.001.CrossRef Schmidt H, Heuer F, Simon U, Kettler A, Rohlmann A, Claes L, Wilke HJ: Application of a new calibration method for a three-dimensional finite element model of a human lumbar annulus fibrosus. Clin Biomech. 2006, 21 (4): 337-344. 10.1016/j.clinbiomech.2005.12.001.CrossRef
31.
go back to reference Kettler A, Rohlmann F, Ring C, Mack C, Wilke HJ: Do early stages of lumbar intervertebral disc degeneration really cause instability? Evaluation of an in vitro database. Eur Spine J. 2011, 20 (4): 578-584. 10.1007/s00586-010-1635-z.CrossRefPubMed Kettler A, Rohlmann F, Ring C, Mack C, Wilke HJ: Do early stages of lumbar intervertebral disc degeneration really cause instability? Evaluation of an in vitro database. Eur Spine J. 2011, 20 (4): 578-584. 10.1007/s00586-010-1635-z.CrossRefPubMed
32.
go back to reference Ruberte LM, Natarajan RN, Andersson GB: Influence of single-level lumbar degenerative disc disease on the behavior of the adjacent segments–a finite element model study. J Biomech. 2009, 42 (3): 341-348. 10.1016/j.jbiomech.2008.11.024.CrossRefPubMed Ruberte LM, Natarajan RN, Andersson GB: Influence of single-level lumbar degenerative disc disease on the behavior of the adjacent segments–a finite element model study. J Biomech. 2009, 42 (3): 341-348. 10.1016/j.jbiomech.2008.11.024.CrossRefPubMed
33.
go back to reference McMillan DW, McNally DS, Garbutt G, Adams MA: Stress distributions inside intervertebral discs: The validity of experimental stress profilometry. Proc Inst Mech Eng H. 1996, 210 (2): 81-87.CrossRefPubMed McMillan DW, McNally DS, Garbutt G, Adams MA: Stress distributions inside intervertebral discs: The validity of experimental stress profilometry. Proc Inst Mech Eng H. 1996, 210 (2): 81-87.CrossRefPubMed
34.
go back to reference Yamamoto I, Panjabi MM, Crisco T, Oxland T: Three-D Moments of the Whole Lumbar Spoie and Lumbosacral Joint. Spine. 1989, 14 (11): 1256-1260. 10.1097/00007632-198911000-00020.CrossRefPubMed Yamamoto I, Panjabi MM, Crisco T, Oxland T: Three-D Moments of the Whole Lumbar Spoie and Lumbosacral Joint. Spine. 1989, 14 (11): 1256-1260. 10.1097/00007632-198911000-00020.CrossRefPubMed
35.
go back to reference Panjabi MM: Hybrid multidirectional test method to evaluate spinal adjacent - level effects. Clin Biomech. 2007, 22 (3): 257-265. 10.1016/j.clinbiomech.2006.08.006.CrossRef Panjabi MM: Hybrid multidirectional test method to evaluate spinal adjacent - level effects. Clin Biomech. 2007, 22 (3): 257-265. 10.1016/j.clinbiomech.2006.08.006.CrossRef
36.
go back to reference Okawa A, Shinomiya K, Takakuda K, Nakai O: A cadaveric study on the stability of lumbar segment after partial laminotomy and facetectomy with intact posterior ligaments. J Spinal Disord. 1996, 9 (6): 518-526.CrossRefPubMed Okawa A, Shinomiya K, Takakuda K, Nakai O: A cadaveric study on the stability of lumbar segment after partial laminotomy and facetectomy with intact posterior ligaments. J Spinal Disord. 1996, 9 (6): 518-526.CrossRefPubMed
37.
go back to reference Bresnahan L, Ogden AT, Natarajan RN, Fessler RG: A biomechanical evaluation of graded posterior element removal for treatment of lumbar stenosis: comparison of a minimally invasive approach with two standard laminectomy techniques. Spine. 2009, 34 (1): 17-23. 10.1097/BRS.0b013e318191438b.CrossRefPubMed Bresnahan L, Ogden AT, Natarajan RN, Fessler RG: A biomechanical evaluation of graded posterior element removal for treatment of lumbar stenosis: comparison of a minimally invasive approach with two standard laminectomy techniques. Spine. 2009, 34 (1): 17-23. 10.1097/BRS.0b013e318191438b.CrossRefPubMed
38.
go back to reference Abumi K, Panjabi MM, Kramer KM, Duranceu J, Oxland T, Crisco JJ: Biomechanical evaluation of lumbar spine stability after graded facetectomies. Spine. 1990, 15 (11): 1142-1147. 10.1097/00007632-199011010-00011.CrossRefPubMed Abumi K, Panjabi MM, Kramer KM, Duranceu J, Oxland T, Crisco JJ: Biomechanical evaluation of lumbar spine stability after graded facetectomies. Spine. 1990, 15 (11): 1142-1147. 10.1097/00007632-199011010-00011.CrossRefPubMed
39.
go back to reference Niosi CA, Zhu QA, Wilson DC, Keynan O, Wilson DR, Oxland TR: Biomechanical characterization of the three-dimensional kinematic behaviour of the Dynesys dynamic stabilization system: an in vitro study. Eur Spine J. 2006, 15 (6): 913-922. 10.1007/s00586-005-0948-9.CrossRefPubMed Niosi CA, Zhu QA, Wilson DC, Keynan O, Wilson DR, Oxland TR: Biomechanical characterization of the three-dimensional kinematic behaviour of the Dynesys dynamic stabilization system: an in vitro study. Eur Spine J. 2006, 15 (6): 913-922. 10.1007/s00586-005-0948-9.CrossRefPubMed
40.
go back to reference Panjabi MM, Henderson G, James Y, Timm P: StabilimaxNZ versus simulated fusion: evaluation of adjacent-Level effects. Eur Spine J. 2007, 16 (12): 2159-2165. 10.1007/s00586-007-0444-5.CrossRefPubMedPubMedCentral Panjabi MM, Henderson G, James Y, Timm P: StabilimaxNZ versus simulated fusion: evaluation of adjacent-Level effects. Eur Spine J. 2007, 16 (12): 2159-2165. 10.1007/s00586-007-0444-5.CrossRefPubMedPubMedCentral
41.
go back to reference Rao RD, Wang M, Singhal P: Intradiscal pressure and kinematic behavior of lumbar spine after bilateral laminotomy and laminectomy. Spine J. 2002, 2 (5): 320-326. 10.1016/S1529-9430(02)00402-3.CrossRefPubMed Rao RD, Wang M, Singhal P: Intradiscal pressure and kinematic behavior of lumbar spine after bilateral laminotomy and laminectomy. Spine J. 2002, 2 (5): 320-326. 10.1016/S1529-9430(02)00402-3.CrossRefPubMed
42.
go back to reference Cunningham BW, Kotani Y, McNulty PS, Cappuccino A, McAfee PC: The effect of spinal destabilization and instrumentation on lumbar intradiscal pressure: an in vitro biomechanical analysis. Spine. 1997, 22 (22): 2655-2263. 10.1097/00007632-199711150-00014.CrossRefPubMed Cunningham BW, Kotani Y, McNulty PS, Cappuccino A, McAfee PC: The effect of spinal destabilization and instrumentation on lumbar intradiscal pressure: an in vitro biomechanical analysis. Spine. 1997, 22 (22): 2655-2263. 10.1097/00007632-199711150-00014.CrossRefPubMed
43.
go back to reference Haher TR, O'Brien M, Dryer JW, Nucci R, Zipnick R, Leone DJ: The role of the lumbar facet joints in spinal stability. Identification of alternative paths of loading. Spine. 1994, 19 (23): 2667-2671.CrossRefPubMed Haher TR, O'Brien M, Dryer JW, Nucci R, Zipnick R, Leone DJ: The role of the lumbar facet joints in spinal stability. Identification of alternative paths of loading. Spine. 1994, 19 (23): 2667-2671.CrossRefPubMed
44.
go back to reference Kiapour A, Ambati D, Hoy RW, Goel VK: Effect of graded facetectomy on biomechanics of Dynesys dynamic stabilization system. Spine. 2012, 37 (10): E581-E589. 10.1097/BRS.0b013e3182463775.CrossRefPubMed Kiapour A, Ambati D, Hoy RW, Goel VK: Effect of graded facetectomy on biomechanics of Dynesys dynamic stabilization system. Spine. 2012, 37 (10): E581-E589. 10.1097/BRS.0b013e3182463775.CrossRefPubMed
45.
go back to reference Kuo CS, Hu HT, Lin RM, Huang KY, Lin PC, Zhong ZC, Hseih ML: Biomechanical analysis of the lumbar spine on facet joint force and intradiscal pressure - a finite element study. BMC Musculoskelet Disord. 2010, 11: 151-10.1186/1471-2474-11-151.CrossRefPubMedPubMedCentral Kuo CS, Hu HT, Lin RM, Huang KY, Lin PC, Zhong ZC, Hseih ML: Biomechanical analysis of the lumbar spine on facet joint force and intradiscal pressure - a finite element study. BMC Musculoskelet Disord. 2010, 11: 151-10.1186/1471-2474-11-151.CrossRefPubMedPubMedCentral
46.
go back to reference Serhan HA, Varnavas G, Dooris AP, Patwadhan A, Tzermiadianos M: Biomechanics of the posterior lumbar articulating elements. Neurosurg Focus. 2007, 22 (1): E1-CrossRefPubMed Serhan HA, Varnavas G, Dooris AP, Patwadhan A, Tzermiadianos M: Biomechanics of the posterior lumbar articulating elements. Neurosurg Focus. 2007, 22 (1): E1-CrossRefPubMed
47.
go back to reference Zander T, Rohlmann A, Klockner C, Bergmann G: Influence of graded facetectomy and laminectomy on spinal biomechanics. Eur Spine J. 2003, 12: 427-434. 10.1007/s00586-003-0540-0.CrossRefPubMedPubMedCentral Zander T, Rohlmann A, Klockner C, Bergmann G: Influence of graded facetectomy and laminectomy on spinal biomechanics. Eur Spine J. 2003, 12: 427-434. 10.1007/s00586-003-0540-0.CrossRefPubMedPubMedCentral
48.
go back to reference Rohlmann A, Boustani HN, Bergmann G, Zander T: Effect of a pedicle-screw- based motion preservation system on lumbar spine biomechanics: a probabilistic finite element study with subsequent sensitivity analysis. J Biomech. 2010, 43: 2963-2969. 10.1016/j.jbiomech.2010.07.018.CrossRefPubMed Rohlmann A, Boustani HN, Bergmann G, Zander T: Effect of a pedicle-screw- based motion preservation system on lumbar spine biomechanics: a probabilistic finite element study with subsequent sensitivity analysis. J Biomech. 2010, 43: 2963-2969. 10.1016/j.jbiomech.2010.07.018.CrossRefPubMed
49.
go back to reference Lee KK, Teo EC, Qiu TX, Yang K: Effect of facetectomy on lumbar spinal stability under sagittal plane loadings. Spine. 2004, 29 (15): 1624-1631. 10.1097/01.BRS.0000132650.24437.15.CrossRefPubMed Lee KK, Teo EC, Qiu TX, Yang K: Effect of facetectomy on lumbar spinal stability under sagittal plane loadings. Spine. 2004, 29 (15): 1624-1631. 10.1097/01.BRS.0000132650.24437.15.CrossRefPubMed
Metadata
Title
Effects of cord pretension and stiffness of the Dynesys system spacer on the biomechanics of spinal decompression- a finite element study
Authors
Shih-Liang Shih
Chien-Lin Liu
Li-Ying Huang
Chang-Hung Huang
Chen-Sheng Chen
Publication date
01-12-2013
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2013
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-14-191

Other articles of this Issue 1/2013

BMC Musculoskeletal Disorders 1/2013 Go to the issue