Skip to main content
Top
Published in: BMC Medical Imaging 1/2013

Open Access 01-12-2013 | Research article

Automatic detection of anomalies in screening mammograms

Authors: Edward J Kendall, Michael G Barnett, Krista Chytyk-Praznik

Published in: BMC Medical Imaging | Issue 1/2013

Login to get access

Abstract

Background

Diagnostic performance in breast screening programs may be influenced by the prior probability of disease. Since breast cancer incidence is roughly half a percent in the general population there is a large probability that the screening exam will be normal. That factor may contribute to false negatives. Screening programs typically exhibit about 83% sensitivity and 91% specificity. This investigation was undertaken to determine if a system could be developed to pre-sort screening-images into normal and suspicious bins based on their likelihood to contain disease. Wavelets were investigated as a method to parse the image data, potentially removing confounding information. The development of a classification system based on features extracted from wavelet transformed mammograms is reported.

Methods

In the multi-step procedure images were processed using 2D discrete wavelet transforms to create a set of maps at different size scales. Next, statistical features were computed from each map, and a subset of these features was the input for a concerted-effort set of naïve Bayesian classifiers. The classifier network was constructed to calculate the probability that the parent mammography image contained an abnormality. The abnormalities were not identified, nor were they regionalized.
The algorithm was tested on two publicly available databases: the Digital Database for Screening Mammography (DDSM) and the Mammographic Images Analysis Society’s database (MIAS). These databases contain radiologist-verified images and feature common abnormalities including: spiculations, masses, geometric deformations and fibroid tissues.

Results

The classifier-network designs tested achieved sensitivities and specificities sufficient to be potentially useful in a clinical setting. This first series of tests identified networks with 100% sensitivity and up to 79% specificity for abnormalities. This performance significantly exceeds the mean sensitivity reported in literature for the unaided human expert.

Conclusions

Classifiers based on wavelet-derived features proved to be highly sensitive to a range of pathologies, as a result Type II errors were nearly eliminated. Pre-sorting the images changed the prior probability in the sorted database from 37% to 74%.
Appendix
Available only for authorised users
Literature
1.
go back to reference Canadian-Cancer-Statistics-2012---English.pdf. Canadian Cancer Society’s Advisory Committee on Cancer Statistics: Canadian Cancer Statistics 2012. 2013, Toronto: Canadian Cancer Society Canadian-Cancer-Statistics-2012---English.pdf. Canadian Cancer Society’s Advisory Committee on Cancer Statistics: Canadian Cancer Statistics 2012. 2013, Toronto: Canadian Cancer Society
2.
go back to reference Wadden N: Breast cancer screening in Canada: a review. Can Assoc Radiol J. 2005, 56 (5): 271-275.PubMed Wadden N: Breast cancer screening in Canada: a review. Can Assoc Radiol J. 2005, 56 (5): 271-275.PubMed
3.
go back to reference Wadden N, Doyle GP: Breast cancer screening in Canada: a review (vol 56, pg 5, 2005). Can Assoc Radiol J. 2006, 57 (2): 67- Wadden N, Doyle GP: Breast cancer screening in Canada: a review (vol 56, pg 5, 2005). Can Assoc Radiol J. 2006, 57 (2): 67-
4.
go back to reference Cheng HD, Shi XJ, Min R, Hu LM, Cai XR, Du HN: Approaches for automated detection and classification of masses in mammograms. Pattern Recogn. 2006, 39 (4): 646-668. 10.1016/j.patcog.2005.07.006.CrossRef Cheng HD, Shi XJ, Min R, Hu LM, Cai XR, Du HN: Approaches for automated detection and classification of masses in mammograms. Pattern Recogn. 2006, 39 (4): 646-668. 10.1016/j.patcog.2005.07.006.CrossRef
5.
go back to reference Jiang Y, Nishikawa RM, Schmidt RA, Metz CE: Comparison of independent double readings and computer-aided diagnosis (CAD) for the diagnosis of breast calcifications. Acad Radiol. 2006, 13 (1): 84-94. 10.1016/j.acra.2005.09.086.CrossRefPubMed Jiang Y, Nishikawa RM, Schmidt RA, Metz CE: Comparison of independent double readings and computer-aided diagnosis (CAD) for the diagnosis of breast calcifications. Acad Radiol. 2006, 13 (1): 84-94. 10.1016/j.acra.2005.09.086.CrossRefPubMed
6.
go back to reference Sentelle S, Sentelle C, Sutton MA: Multiresolution-based segmentation of calcifications for the early detection of breast cancer. Real-Time Imaging. 2002, 8 (3): 237-252. 10.1006/rtim.2001.0285.CrossRef Sentelle S, Sentelle C, Sutton MA: Multiresolution-based segmentation of calcifications for the early detection of breast cancer. Real-Time Imaging. 2002, 8 (3): 237-252. 10.1006/rtim.2001.0285.CrossRef
7.
go back to reference Tang JS, Rangayyan RM, Xu J, El Naqa I, Yang YY: Computer-aided detection and diagnosis of breast cancer with mammography: recent advances. Ieee T Inf Technol B. 2009, 13 (2): 236-251.CrossRef Tang JS, Rangayyan RM, Xu J, El Naqa I, Yang YY: Computer-aided detection and diagnosis of breast cancer with mammography: recent advances. Ieee T Inf Technol B. 2009, 13 (2): 236-251.CrossRef
8.
go back to reference Torrent A, Oliver A, Llado X, Marti R, Freixenet J: A supervised micro-calcification detection approach in digitised mammograms. Ieee International Conference on Image Processing. 2010, 2010: 4345-4348. Torrent A, Oliver A, Llado X, Marti R, Freixenet J: A supervised micro-calcification detection approach in digitised mammograms. Ieee International Conference on Image Processing. 2010, 2010: 4345-4348.
9.
go back to reference Alto H, Rangayyan RM, Paranjape RB, Desautels JEL, Bryant H: An indexed atlas of digital mammograms for computer-aided diagnosis of breast cancer. Ann Telecommun. 2003, 58 (5–6): 820-835. Alto H, Rangayyan RM, Paranjape RB, Desautels JEL, Bryant H: An indexed atlas of digital mammograms for computer-aided diagnosis of breast cancer. Ann Telecommun. 2003, 58 (5–6): 820-835.
10.
go back to reference Andre TCSS, Rangayyan RM: Classification of breast masses in mammograms using neural networks with shape, edge sharpness, and texture features. J Electron Imaging. 2006, 15 (1): 013019-013019-10-CrossRef Andre TCSS, Rangayyan RM: Classification of breast masses in mammograms using neural networks with shape, edge sharpness, and texture features. J Electron Imaging. 2006, 15 (1): 013019-013019-10-CrossRef
11.
go back to reference Freixenet J, Oliver A, Marti R, Llado X, Pont J, Perez E, Denton ERE, Zwiggelaar R: Eigendetection of masses considering false positive reduction and breast density information. Med Phys. 2008, 35 (5): 1840-1853. 10.1118/1.2897950.CrossRefPubMed Freixenet J, Oliver A, Marti R, Llado X, Pont J, Perez E, Denton ERE, Zwiggelaar R: Eigendetection of masses considering false positive reduction and breast density information. Med Phys. 2008, 35 (5): 1840-1853. 10.1118/1.2897950.CrossRefPubMed
12.
go back to reference Guliato D, Rangayyan RM, Adorno F, Ribeiro MMG: Analysis and classification of breast masses by fuzzy-set-based image processing. Digital Mammography. Edited by: Peitgen HO. 2003, Heidelberg: Springer, 195-197.CrossRef Guliato D, Rangayyan RM, Adorno F, Ribeiro MMG: Analysis and classification of breast masses by fuzzy-set-based image processing. Digital Mammography. Edited by: Peitgen HO. 2003, Heidelberg: Springer, 195-197.CrossRef
13.
go back to reference Guliato D, Rangayyan RM, Carnielli WA, Zuffo JA, Desautels JEL: Segmentation of breast tumors in mammograms by fuzzy region growing. P Ann Int Ieee Embs. 1998, 20: 1002-1005. Guliato D, Rangayyan RM, Carnielli WA, Zuffo JA, Desautels JEL: Segmentation of breast tumors in mammograms by fuzzy region growing. P Ann Int Ieee Embs. 1998, 20: 1002-1005.
14.
go back to reference Guliato D, de Carvalho JD, Rangayyan RM, Santiago SA: Feature extraction from a signature based on the turning angle function for the classification of breast tumors. J Digit Imaging. 2008, 21 (2): 129-144. 10.1007/s10278-007-9069-9.CrossRefPubMed Guliato D, de Carvalho JD, Rangayyan RM, Santiago SA: Feature extraction from a signature based on the turning angle function for the classification of breast tumors. J Digit Imaging. 2008, 21 (2): 129-144. 10.1007/s10278-007-9069-9.CrossRefPubMed
15.
go back to reference Gur D, Stalder JS, Hardesty LA, Zheng B, Sumkin JH, Chough DM, Shindel BE, Rockette HE: Computer-aided detection performance in Mammographic examination of masses: assessment1. Radiology. 2004, 233 (2): 418-423. 10.1148/radiol.2332040277.CrossRefPubMed Gur D, Stalder JS, Hardesty LA, Zheng B, Sumkin JH, Chough DM, Shindel BE, Rockette HE: Computer-aided detection performance in Mammographic examination of masses: assessment1. Radiology. 2004, 233 (2): 418-423. 10.1148/radiol.2332040277.CrossRefPubMed
16.
go back to reference Llado X, Oliver A, Freixenet J, Marti R, Marti J: A textural approach for mass false positive reduction in mammography. Comput Med Imag Grap. 2009, 33 (6): 415-422. 10.1016/j.compmedimag.2009.03.007.CrossRef Llado X, Oliver A, Freixenet J, Marti R, Marti J: A textural approach for mass false positive reduction in mammography. Comput Med Imag Grap. 2009, 33 (6): 415-422. 10.1016/j.compmedimag.2009.03.007.CrossRef
17.
go back to reference Rangayyan RM, Ayres FJ, Desautels JEL: A review of computer-aided diagnosis of breast cancer: Toward the detection of subtle signs. J Franklin I. 2007, 344 (3–4): 312-348.CrossRef Rangayyan RM, Ayres FJ, Desautels JEL: A review of computer-aided diagnosis of breast cancer: Toward the detection of subtle signs. J Franklin I. 2007, 344 (3–4): 312-348.CrossRef
18.
go back to reference Prajna S, Rangayyan RM, Ayres FJ, Desautels JEL: Detection of architectural distortion in mammograms acquired prior to the detection of breast cancer using texture and fractal analysis - art. no. 691529. P Soc Photo-Opt Ins. 2008, 6915: 91529- Prajna S, Rangayyan RM, Ayres FJ, Desautels JEL: Detection of architectural distortion in mammograms acquired prior to the detection of breast cancer using texture and fractal analysis - art. no. 691529. P Soc Photo-Opt Ins. 2008, 6915: 91529-
19.
go back to reference Astley SM: Computer-aided detection for screening mammography. Acad Radiol. 2004, 11 (10): 1139-1143. 10.1016/j.acra.2004.07.009.CrossRefPubMed Astley SM: Computer-aided detection for screening mammography. Acad Radiol. 2004, 11 (10): 1139-1143. 10.1016/j.acra.2004.07.009.CrossRefPubMed
20.
go back to reference Gilbert FJ, Astley SM, Gillan MG, Agbaje OF, Wallis MG, James J, Boggis CR, Duffy SW, Group CI: Single reading with computer-aided detection for screening mammography. New Engl J Med. 2008, 359 (16): 1675-1684. 10.1056/NEJMoa0803545.CrossRefPubMed Gilbert FJ, Astley SM, Gillan MG, Agbaje OF, Wallis MG, James J, Boggis CR, Duffy SW, Group CI: Single reading with computer-aided detection for screening mammography. New Engl J Med. 2008, 359 (16): 1675-1684. 10.1056/NEJMoa0803545.CrossRefPubMed
21.
go back to reference Padmanabhan S, Sundararajan R: Texture and statistical analysis of mammograms: A novel method to detect tumor in Breast Cells. 2012, : Machine Vision and Image Processing (MVIP), 2012 International Conference on: 14–15 Dec. 2012 2012, 157-160. Padmanabhan S, Sundararajan R: Texture and statistical analysis of mammograms: A novel method to detect tumor in Breast Cells. 2012, : Machine Vision and Image Processing (MVIP), 2012 International Conference on: 14–15 Dec. 2012 2012, 157-160.
22.
go back to reference Choi JY, Kim DH, Choi SH, Ro YM: Multiresolution local binary pattern texture analysis for false positive reduction in computerized detection of breast masses on mammograms. Proc Spie. 2012, 8315: 83152B-7-10.1117/12.912392.CrossRef Choi JY, Kim DH, Choi SH, Ro YM: Multiresolution local binary pattern texture analysis for false positive reduction in computerized detection of breast masses on mammograms. Proc Spie. 2012, 8315: 83152B-7-10.1117/12.912392.CrossRef
23.
go back to reference Choi JY, Ro YM: Multiresolution local binary pattern texture analysis combined with variable selection for application to false-positive reduction in computer-aided detection of breast masses on mammograms. Phys Med Biol. 2012, 57 (21): 7029-7052. 10.1088/0031-9155/57/21/7029.CrossRefPubMed Choi JY, Ro YM: Multiresolution local binary pattern texture analysis combined with variable selection for application to false-positive reduction in computer-aided detection of breast masses on mammograms. Phys Med Biol. 2012, 57 (21): 7029-7052. 10.1088/0031-9155/57/21/7029.CrossRefPubMed
24.
go back to reference Azavedo E, Zackrisson S, Mejare I, Heibert Arnlind M: Is single reading with computer-aided detection (CAD) as good as double reading in mammography screening? A systematic review. BMC Med Imaging. 2012, 12: 22-10.1186/1471-2342-12-22.CrossRefPubMedPubMedCentral Azavedo E, Zackrisson S, Mejare I, Heibert Arnlind M: Is single reading with computer-aided detection (CAD) as good as double reading in mammography screening? A systematic review. BMC Med Imaging. 2012, 12: 22-10.1186/1471-2342-12-22.CrossRefPubMedPubMedCentral
25.
go back to reference Houssami N, Given-Wilson R: Incorporating new technologies into clinical practice without evidence of effectiveness in prospective studies: computer-aided detection (CAD) in breast screening reinforces the need for better initial evaluation. Breast. 2007, 16 (3): 219-221. 10.1016/j.breast.2007.04.006.CrossRefPubMed Houssami N, Given-Wilson R: Incorporating new technologies into clinical practice without evidence of effectiveness in prospective studies: computer-aided detection (CAD) in breast screening reinforces the need for better initial evaluation. Breast. 2007, 16 (3): 219-221. 10.1016/j.breast.2007.04.006.CrossRefPubMed
26.
go back to reference Heath M, Bowyer K, Kopans D: The digital database for screening mammography. 2001, Madison: Medical Physics Publishing Heath M, Bowyer K, Kopans D: The digital database for screening mammography. 2001, Madison: Medical Physics Publishing
27.
go back to reference Heath M, Bowyer K, Kopans D, Kegelmeyer P, Moore R, Chang K, Munishkumaran S: Current status of the digital database for screening mammography. 1998, Digital Mammography edn: Springer, 457-460.CrossRef Heath M, Bowyer K, Kopans D, Kegelmeyer P, Moore R, Chang K, Munishkumaran S: Current status of the digital database for screening mammography. 1998, Digital Mammography edn: Springer, 457-460.CrossRef
28.
go back to reference Heath M, Bowyer K, Kopans D, Moore R, Kegelmeyer P: The digital database for screening mammography. Proceedings of the 5th international workshop on digital mammography. 2000, : , 212-218. Heath M, Bowyer K, Kopans D, Moore R, Kegelmeyer P: The digital database for screening mammography. Proceedings of the 5th international workshop on digital mammography. 2000, : , 212-218.
29.
go back to reference Suckling J, Parker J, Dance D, Astley S, Hutt I, Boggis C, Ricketts I, Stamatakis E, Cerneaz N, Kok S-L: The mammographic image analysis society digital mammogram database. 1994 Suckling J, Parker J, Dance D, Astley S, Hutt I, Boggis C, Ricketts I, Stamatakis E, Cerneaz N, Kok S-L: The mammographic image analysis society digital mammogram database. 1994
30.
go back to reference Sonka M: Image processing, analysis, and machine vision. 2007, Mason, OH: Thomson: International student edn Sonka M: Image processing, analysis, and machine vision. 2007, Mason, OH: Thomson: International student edn
31.
go back to reference Cui J, Loewy J, Kendall EJ: Automated search for arthritic patterns in infrared spectra of synovial fluid using adaptive wavelets and fuzzy C-means analysis. IEEE Transactions on Bio-Medical Engineering. 2006, 53 (5): 800-809. 10.1109/TBME.2006.872813.CrossRefPubMed Cui J, Loewy J, Kendall EJ: Automated search for arthritic patterns in infrared spectra of synovial fluid using adaptive wavelets and fuzzy C-means analysis. IEEE Transactions on Bio-Medical Engineering. 2006, 53 (5): 800-809. 10.1109/TBME.2006.872813.CrossRefPubMed
32.
go back to reference Cheng HD, Cai XP, Chen XW, Hu LM, Lou XL: Computer-aided detection and classification of microcalcifications in mammograms: a survey. Pattern Recogn. 2003, 36 (12): 2967-2991. 10.1016/S0031-3203(03)00192-4.CrossRef Cheng HD, Cai XP, Chen XW, Hu LM, Lou XL: Computer-aided detection and classification of microcalcifications in mammograms: a survey. Pattern Recogn. 2003, 36 (12): 2967-2991. 10.1016/S0031-3203(03)00192-4.CrossRef
33.
go back to reference Ferreira CB, Borges DL: Analysis of mammogram classification using a wavelet transform decomposition. Pattern Recogn Lett. 2003, 24: 973-982. 10.1016/S0167-8655(02)00221-0.CrossRef Ferreira CB, Borges DL: Analysis of mammogram classification using a wavelet transform decomposition. Pattern Recogn Lett. 2003, 24: 973-982. 10.1016/S0167-8655(02)00221-0.CrossRef
34.
go back to reference Taylor P, Given-Wilson R, Champness J, Potts HWW, Johnston K: Assessing the impact of CAD on the sensitivity and specificity of film readers. Clin Radiol. 2004, 59 (12): 1099-1105. 10.1016/j.crad.2004.04.017.CrossRefPubMed Taylor P, Given-Wilson R, Champness J, Potts HWW, Johnston K: Assessing the impact of CAD on the sensitivity and specificity of film readers. Clin Radiol. 2004, 59 (12): 1099-1105. 10.1016/j.crad.2004.04.017.CrossRefPubMed
35.
go back to reference Rangayyan RM, Nguyen TM, Ayres FJ, Nandi AK: Effect of pixel resolution on texture features of breast masses in mammograms. J Digit Imaging. 2010, 23 (5): 547-553. 10.1007/s10278-009-9238-0.CrossRefPubMed Rangayyan RM, Nguyen TM, Ayres FJ, Nandi AK: Effect of pixel resolution on texture features of breast masses in mammograms. J Digit Imaging. 2010, 23 (5): 547-553. 10.1007/s10278-009-9238-0.CrossRefPubMed
36.
go back to reference Coldman AJ, Major D, Doyle GP, D’yachkova Y, Phillips N, Onysko J, Shumak R, Smith NE, Wadden N: Organized breast screening programs in Canada: effect of radiologist reading volumes on outcomes1. Radiology. 2006, 238 (3): 809-815. 10.1148/radiol.2382041684.CrossRefPubMed Coldman AJ, Major D, Doyle GP, D’yachkova Y, Phillips N, Onysko J, Shumak R, Smith NE, Wadden N: Organized breast screening programs in Canada: effect of radiologist reading volumes on outcomes1. Radiology. 2006, 238 (3): 809-815. 10.1148/radiol.2382041684.CrossRefPubMed
37.
go back to reference Elmore JG, Armstrong K, Lehman CD, Fletcher SW: Screening for breast cancer. Jama-J Am Med Assoc. 2005, 293 (10): 1245-1256. 10.1001/jama.293.10.1245.CrossRef Elmore JG, Armstrong K, Lehman CD, Fletcher SW: Screening for breast cancer. Jama-J Am Med Assoc. 2005, 293 (10): 1245-1256. 10.1001/jama.293.10.1245.CrossRef
38.
go back to reference Fenton JJ, Abraham L, Taplin SH, Geller BM, Carney PA, D’Orsi C, Elmore JG, Barlow WE: Effectiveness of computer-aided detection in community mammography practice. J Natl Cancer Inst. 2011, 103 (15): 1152-1161. 10.1093/jnci/djr206.CrossRefPubMedPubMedCentral Fenton JJ, Abraham L, Taplin SH, Geller BM, Carney PA, D’Orsi C, Elmore JG, Barlow WE: Effectiveness of computer-aided detection in community mammography practice. J Natl Cancer Inst. 2011, 103 (15): 1152-1161. 10.1093/jnci/djr206.CrossRefPubMedPubMedCentral
39.
go back to reference Kendall EJ, Barnett MG: Image analysis. 2010, In. vol. 12808099. US Kendall EJ, Barnett MG: Image analysis. 2010, In. vol. 12808099. US
Metadata
Title
Automatic detection of anomalies in screening mammograms
Authors
Edward J Kendall
Michael G Barnett
Krista Chytyk-Praznik
Publication date
01-12-2013
Publisher
BioMed Central
Published in
BMC Medical Imaging / Issue 1/2013
Electronic ISSN: 1471-2342
DOI
https://doi.org/10.1186/1471-2342-13-43

Other articles of this Issue 1/2013

BMC Medical Imaging 1/2013 Go to the issue