Skip to main content
Top
Published in: Annals of Intensive Care 1/2018

Open Access 01-12-2018 | Research

Internal jugular vein variability predicts fluid responsiveness in cardiac surgical patients with mechanical ventilation

Authors: Guo-guang Ma, Guang-wei Hao, Xiao-mei Yang, Du-ming Zhu, Lan Liu, Hua Liu, Guo-wei Tu, Zhe Luo

Published in: Annals of Intensive Care | Issue 1/2018

Login to get access

Abstract

Background

To evaluate the efficacy of using internal jugular vein variability (IJVV) as an index of fluid responsiveness in mechanically ventilated patients after cardiac surgery.

Methods

Seventy patients were assessed after cardiac surgery. Hemodynamic data coupled with ultrasound evaluation of IJVV and inferior vena cava variability (IVCV) were collected and calculated at baseline, after a passive leg raising (PLR) test and after a 500-ml fluid challenge. Patients were divided into volume responders (increase in stroke volume ≥ 15%) and non-responders (increase in stroke volume < 15%). We compared the differences in measured variables between responders and non-responders and tested the ability of the indices to predict fluid responsiveness.

Results

Thirty-five (50%) patients were fluid responders. Responders presented higher IJVV, IVCV and stroke volume variation (SVV) compared with non-responders at baseline (P < 0.05). The relationship between IJVV and SVV was moderately correlated (r = 0.51, P < 0.01). The areas under the receiver operating characteristic (ROC) curves for predicting fluid responsiveness were 0.88 (CI 0.78–0.94) for IJVV compared with 0.83 (CI 0.72–0.91), 0.97 (CI 0.89–0.99), 0.91 (CI 0.82–0.97) for IVCV, SVV, and the increase in stroke volume in response to a PLR test, respectively.

Conclusions

Ultrasound-derived IJVV is an accurate, easily acquired noninvasive parameter of fluid responsiveness in mechanically ventilated postoperative cardiac surgery patients, with a performance similar to that of IVCV.
Appendix
Available only for authorised users
Literature
1.
go back to reference Lee J, de Louw E, Niemi M, Nelson R, Mark RG, Celi LA, et al. Association between fluid balance and survival in critically ill patients. J Intern Med. 2015;277:468–77.CrossRefPubMed Lee J, de Louw E, Niemi M, Nelson R, Mark RG, Celi LA, et al. Association between fluid balance and survival in critically ill patients. J Intern Med. 2015;277:468–77.CrossRefPubMed
2.
go back to reference Carsetti A, Cecconi M, Rhodes A. Fluid bolus therapy: monitoring and predicting fluid responsiveness. Curr Opin Crit Care. 2015;21:388–94.CrossRefPubMed Carsetti A, Cecconi M, Rhodes A. Fluid bolus therapy: monitoring and predicting fluid responsiveness. Curr Opin Crit Care. 2015;21:388–94.CrossRefPubMed
3.
go back to reference Kalus JS, Caron MF, White CM, Mather JF, Gallagher R, Boden WE, et al. Impact of fluid balance on incidence of atrial fibrillation after cardiothoracic surgery. Am J Cardiol. 2004;94:1423–5.CrossRefPubMed Kalus JS, Caron MF, White CM, Mather JF, Gallagher R, Boden WE, et al. Impact of fluid balance on incidence of atrial fibrillation after cardiothoracic surgery. Am J Cardiol. 2004;94:1423–5.CrossRefPubMed
4.
go back to reference Mentzer RM Jr. Myocardial protection in heart surgery. J Cardiovasc Pharmacol Ther. 2011;16:290–7.CrossRefPubMed Mentzer RM Jr. Myocardial protection in heart surgery. J Cardiovasc Pharmacol Ther. 2011;16:290–7.CrossRefPubMed
5.
go back to reference Donati A, Carsetti A, Damiani E, Adrario E, Romano R, Pelaia P. Fluid responsiveness in critically ill patients. Indian J Crit Care Med. 2015;19:375–6.CrossRefPubMedPubMedCentral Donati A, Carsetti A, Damiani E, Adrario E, Romano R, Pelaia P. Fluid responsiveness in critically ill patients. Indian J Crit Care Med. 2015;19:375–6.CrossRefPubMedPubMedCentral
6.
go back to reference Suzuki S, Woinarski NC, Lipcsey M, Candal CL, Schneider AG, Glassford NJ, et al. Pulse pressure variation-guided fluid therapy after cardiac surgery: a pilot before-and-after trial. J Crit Care. 2014;29:992–6.CrossRefPubMed Suzuki S, Woinarski NC, Lipcsey M, Candal CL, Schneider AG, Glassford NJ, et al. Pulse pressure variation-guided fluid therapy after cardiac surgery: a pilot before-and-after trial. J Crit Care. 2014;29:992–6.CrossRefPubMed
7.
go back to reference Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37:2642–7.CrossRefPubMed Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37:2642–7.CrossRefPubMed
8.
go back to reference Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med. 2000;162:134–8.CrossRefPubMed Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med. 2000;162:134–8.CrossRefPubMed
9.
go back to reference Vieillard-Baron A, Chergui K, Rabiller A, Peyrouset O, Page B, Beauchet A, et al. Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients. Intensive Care Med. 2004;30:1734–9.CrossRefPubMed Vieillard-Baron A, Chergui K, Rabiller A, Peyrouset O, Page B, Beauchet A, et al. Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients. Intensive Care Med. 2004;30:1734–9.CrossRefPubMed
10.
go back to reference Barbier C, Loubieres Y, Schmit C, Hayon J, Ricome JL, Jardin F, et al. Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med. 2004;30:1740–6.PubMed Barbier C, Loubieres Y, Schmit C, Hayon J, Ricome JL, Jardin F, et al. Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med. 2004;30:1740–6.PubMed
11.
go back to reference Tavazzi G, Price S, Fletcher N. Bedside ultrasonographic measurement of the inferior vena cava. J Cardiothorac Vasc Anesth. 2015;29:e54–5.CrossRefPubMed Tavazzi G, Price S, Fletcher N. Bedside ultrasonographic measurement of the inferior vena cava. J Cardiothorac Vasc Anesth. 2015;29:e54–5.CrossRefPubMed
12.
go back to reference Sobczyk D, Nycz K, Andruszkiewicz P. Bedside ultrasonographic measurement of the inferior vena cava fails to predict fluid responsiveness in the first 6 hours after cardiac surgery: a prospective case series observational study. J Cardiothorac Vasc Anesth. 2015;29:663–9.CrossRefPubMed Sobczyk D, Nycz K, Andruszkiewicz P. Bedside ultrasonographic measurement of the inferior vena cava fails to predict fluid responsiveness in the first 6 hours after cardiac surgery: a prospective case series observational study. J Cardiothorac Vasc Anesth. 2015;29:663–9.CrossRefPubMed
13.
go back to reference Nagdev AD, Merchant RC, Tirado-Gonzalez A, Sisson CA, Murphy MC. Emergency department bedside ultrasonographic measurement of the caval index for noninvasive determination of low central venous pressure. Ann Emerg Med. 2010;55:290–5.CrossRefPubMed Nagdev AD, Merchant RC, Tirado-Gonzalez A, Sisson CA, Murphy MC. Emergency department bedside ultrasonographic measurement of the caval index for noninvasive determination of low central venous pressure. Ann Emerg Med. 2010;55:290–5.CrossRefPubMed
14.
go back to reference Chua Chiaco JM, Parikh NI, Fergusson DJ. The jugular venous pressure revisited. Cleve Clin J Med. 2013;80:638–44.CrossRefPubMed Chua Chiaco JM, Parikh NI, Fergusson DJ. The jugular venous pressure revisited. Cleve Clin J Med. 2013;80:638–44.CrossRefPubMed
15.
go back to reference Conn RD, O’Keefe JH. Simplified evaluation of the jugular venous pressure: significance of inspiratory collapse of jugular veins. Mo Med. 2012;109:150–2.PubMed Conn RD, O’Keefe JH. Simplified evaluation of the jugular venous pressure: significance of inspiratory collapse of jugular veins. Mo Med. 2012;109:150–2.PubMed
16.
go back to reference Constant J. Using internal jugular pulsations as a manometer for right atrial pressure measurements. Cardiology. 2000;93:26–30.CrossRefPubMed Constant J. Using internal jugular pulsations as a manometer for right atrial pressure measurements. Cardiology. 2000;93:26–30.CrossRefPubMed
17.
go back to reference Thudium M, Klaschik S, Ellerkmann RK, Putensen C, Hilbert T. Is internal jugular vein extensibility associated with indices of fluid responsiveness in ventilated patients? Acta Anaesthesiol Scand. 2016;60:723–33.CrossRefPubMed Thudium M, Klaschik S, Ellerkmann RK, Putensen C, Hilbert T. Is internal jugular vein extensibility associated with indices of fluid responsiveness in ventilated patients? Acta Anaesthesiol Scand. 2016;60:723–33.CrossRefPubMed
18.
go back to reference Broilo F, Meregalli A, Friedman G. Right internal jugular vein distensibility appears to be a surrogate marker for inferior vena cava vein distensibility for evaluating fluid responsiveness. Rev Bras Ter Intensiva. 2015;27:205–11.CrossRefPubMedPubMedCentral Broilo F, Meregalli A, Friedman G. Right internal jugular vein distensibility appears to be a surrogate marker for inferior vena cava vein distensibility for evaluating fluid responsiveness. Rev Bras Ter Intensiva. 2015;27:205–11.CrossRefPubMedPubMedCentral
19.
go back to reference Guarracino F, Ferro B, Forfori F, Bertini P, Magliacano L, Pinsky MR. Jugular vein distensibility predicts fluid responsiveness in septic patients. Crit Care. 2014;18:647.CrossRefPubMedPubMedCentral Guarracino F, Ferro B, Forfori F, Bertini P, Magliacano L, Pinsky MR. Jugular vein distensibility predicts fluid responsiveness in septic patients. Crit Care. 2014;18:647.CrossRefPubMedPubMedCentral
20.
go back to reference Prekker ME, Scott NL, Hart D, Sprenkle MD, Leatherman JW. Point-of-care ultrasound to estimate central venous pressure: a comparison of three techniques. Crit Care Med. 2013;41:833–41.CrossRefPubMed Prekker ME, Scott NL, Hart D, Sprenkle MD, Leatherman JW. Point-of-care ultrasound to estimate central venous pressure: a comparison of three techniques. Crit Care Med. 2013;41:833–41.CrossRefPubMed
21.
23.
go back to reference Preisman S, Kogan S, Berkenstadt H, Perel A. Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators. Br J Anaesth. 2005;95:746–55.CrossRefPubMed Preisman S, Kogan S, Berkenstadt H, Perel A. Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators. Br J Anaesth. 2005;95:746–55.CrossRefPubMed
24.
go back to reference Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest. 2008;134:172–8.CrossRefPubMed Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest. 2008;134:172–8.CrossRefPubMed
25.
go back to reference Osman D, Ridel C, Ray P, Monnet X, Anguel N, Richard C, et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med. 2007;35:64–8.CrossRefPubMed Osman D, Ridel C, Ray P, Monnet X, Anguel N, Richard C, et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med. 2007;35:64–8.CrossRefPubMed
26.
go back to reference De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL. Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med. 2005;31:517–23.CrossRefPubMed De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL. Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med. 2005;31:517–23.CrossRefPubMed
27.
go back to reference Unluer EE, Kara PH. Ultrasonography of jugular vein as a marker of hypovolemia in healthy volunteers. Am J Emerg Med. 2013;31:173–7.CrossRefPubMed Unluer EE, Kara PH. Ultrasonography of jugular vein as a marker of hypovolemia in healthy volunteers. Am J Emerg Med. 2013;31:173–7.CrossRefPubMed
28.
go back to reference Akilli NB, Cander B, Dundar ZD, Koylu R. A new parameter for the diagnosis of hemorrhagic shock: jugular index. J Crit Care. 2012;27(530):e13–8. Akilli NB, Cander B, Dundar ZD, Koylu R. A new parameter for the diagnosis of hemorrhagic shock: jugular index. J Crit Care. 2012;27(530):e13–8.
29.
go back to reference Marque S, Gros A, Chimot L, Gacouin A, Lavoue S, Camus C, et al. Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo. J Clin Monit Comput. 2013;27:273–9.CrossRefPubMed Marque S, Gros A, Chimot L, Gacouin A, Lavoue S, Camus C, et al. Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo. J Clin Monit Comput. 2013;27:273–9.CrossRefPubMed
30.
go back to reference Monnet X, Anguel N, Jozwiak M, Richard C, Teboul JL. Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients. Br J Anaesth. 2012;108:615–22.CrossRefPubMed Monnet X, Anguel N, Jozwiak M, Richard C, Teboul JL. Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients. Br J Anaesth. 2012;108:615–22.CrossRefPubMed
31.
go back to reference De Backer D, Marx G, Tan A, Junker C, Van Nuffelen M, Huter L, et al. Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients. Intensive Care Med. 2011;37:233–40.CrossRefPubMed De Backer D, Marx G, Tan A, Junker C, Van Nuffelen M, Huter L, et al. Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients. Intensive Care Med. 2011;37:233–40.CrossRefPubMed
32.
go back to reference Krige A, Bland M, Fanshawe T. Fluid responsiveness prediction using Vigileo FloTrac measured cardiac output changes during passive leg raise test. J Intensive Care. 2016;4:63.CrossRefPubMedPubMedCentral Krige A, Bland M, Fanshawe T. Fluid responsiveness prediction using Vigileo FloTrac measured cardiac output changes during passive leg raise test. J Intensive Care. 2016;4:63.CrossRefPubMedPubMedCentral
33.
go back to reference Kim SY, Song Y, Shim JK, Kwak YL. Effect of pulse pressure on the predictability of stroke volume variation for fluid responsiveness in patients with coronary disease. J Crit Care. 2013;28(318):e1–7. Kim SY, Song Y, Shim JK, Kwak YL. Effect of pulse pressure on the predictability of stroke volume variation for fluid responsiveness in patients with coronary disease. J Crit Care. 2013;28(318):e1–7.
34.
go back to reference Cannesson M, Musard H, Desebbe O, Boucau C, Simon R, Henaine R, et al. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg. 2009;108:513–7.CrossRefPubMed Cannesson M, Musard H, Desebbe O, Boucau C, Simon R, Henaine R, et al. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg. 2009;108:513–7.CrossRefPubMed
Metadata
Title
Internal jugular vein variability predicts fluid responsiveness in cardiac surgical patients with mechanical ventilation
Authors
Guo-guang Ma
Guang-wei Hao
Xiao-mei Yang
Du-ming Zhu
Lan Liu
Hua Liu
Guo-wei Tu
Zhe Luo
Publication date
01-12-2018
Publisher
Springer International Publishing
Published in
Annals of Intensive Care / Issue 1/2018
Electronic ISSN: 2110-5820
DOI
https://doi.org/10.1186/s13613-017-0347-5

Other articles of this Issue 1/2018

Annals of Intensive Care 1/2018 Go to the issue