Skip to main content
Top
Published in: Malaria Journal 1/2018

Open Access 01-12-2018 | Review

Malaria and the ‘last’ parasite: how can technology help?

Authors: Ngoc Minh Pham, Walter Karlen, Hans-Peter Beck, Emmanuel Delamarche

Published in: Malaria Journal | Issue 1/2018

Login to get access

Abstract

Malaria, together with HIV/AIDS, tuberculosis and hepatitis are the four most deadly infectious diseases globally. Progress in eliminating malaria has saved millions of lives, but also creates new challenges in detecting the ‘last parasite’. Effective and accurate detection of malaria infections, both in symptomatic and asymptomatic individuals are needed. In this review, the current progress in developing new diagnostic tools to fight malaria is presented. An ideal rapid test for malaria elimination is envisioned with examples to demonstrate how innovative technologies can assist the global defeat against this disease. Diagnostic gaps where technology can bring an impact to the elimination campaign for malaria are identified. Finally, how a combination of microfluidic-based technologies and smartphone-based read-outs could potentially represent the next generation of rapid diagnostic tests is discussed.
Literature
2.
go back to reference WHO. Accelerating progress on HIV, tuberculosis, malaria, hepatitis and neglected tropical diseases : a new agenda for 2016–2030. Geneva: World Health Organization; 2015. p. 64. WHO. Accelerating progress on HIV, tuberculosis, malaria, hepatitis and neglected tropical diseases : a new agenda for 2016–2030. Geneva: World Health Organization; 2015. p. 64.
3.
go back to reference WHO. World malaria report 2017. Geneva: World Health Organization; 2017. WHO. World malaria report 2017. Geneva: World Health Organization; 2017.
4.
go back to reference Gates Foundation. From aspiration to action: what will it take to end malaria. Seattle: Bill & Melinda Gates Foundation; 2015. Gates Foundation. From aspiration to action: what will it take to end malaria. Seattle: Bill & Melinda Gates Foundation; 2015.
5.
go back to reference WHO. Global technical strategy for malaria 2016–2030. Geneva: World Health Organization; 2015. WHO. Global technical strategy for malaria 2016–2030. Geneva: World Health Organization; 2015.
6.
go back to reference Mabey D, Peeling RW, Ustianowski A, Perkins MD. Diagnostics for the developing world. Nat Rev Microbiol. 2004;2:231–40.PubMedCrossRef Mabey D, Peeling RW, Ustianowski A, Perkins MD. Diagnostics for the developing world. Nat Rev Microbiol. 2004;2:231–40.PubMedCrossRef
8.
go back to reference The malERA Consultative Group on Diagnoses and Diagnostics. A research agenda for malaria eradication: diagnoses and diagnostics. PLoS Med. 2011;8:1–10.CrossRef The malERA Consultative Group on Diagnoses and Diagnostics. A research agenda for malaria eradication: diagnoses and diagnostics. PLoS Med. 2011;8:1–10.CrossRef
9.
go back to reference Vallejo AF, Martínez NL, González IJ, Arévalo-Herrera M, Herrera S. Evaluation of the loop mediated isothermal DNA amplification (LAMP) kit for malaria diagnosis in P. vivax endemic settings of Colombia. PLoS Negl Trop Dis. 2015;9:e3453.PubMedPubMedCentralCrossRef Vallejo AF, Martínez NL, González IJ, Arévalo-Herrera M, Herrera S. Evaluation of the loop mediated isothermal DNA amplification (LAMP) kit for malaria diagnosis in P. vivax endemic settings of Colombia. PLoS Negl Trop Dis. 2015;9:e3453.PubMedPubMedCentralCrossRef
10.
go back to reference Cook J, Aydin-Schmidt B, González IJ, Bell D, Edlund E, Nassor MH, et al. Loop-mediated isothermal amplification (LAMP) for point-of-care detection of asymptomatic low-density malaria parasite carriers in Zanzibar. Malar J. 2015;14:43.PubMedPubMedCentralCrossRef Cook J, Aydin-Schmidt B, González IJ, Bell D, Edlund E, Nassor MH, et al. Loop-mediated isothermal amplification (LAMP) for point-of-care detection of asymptomatic low-density malaria parasite carriers in Zanzibar. Malar J. 2015;14:43.PubMedPubMedCentralCrossRef
11.
go back to reference Lucchi NW, Ndiaye D, Britton S, Udhayakumar V. Expanding the malaria molecular diagnostic options: opportunities and challenges for loop-mediated isothermal amplification tests for malaria control and elimination. Expert Rev Mol Diagn. 2018;18:195–203.PubMedCrossRef Lucchi NW, Ndiaye D, Britton S, Udhayakumar V. Expanding the malaria molecular diagnostic options: opportunities and challenges for loop-mediated isothermal amplification tests for malaria control and elimination. Expert Rev Mol Diagn. 2018;18:195–203.PubMedCrossRef
13.
go back to reference WHO. New perspective in malaria diagnosis. Geneva: World Health Organization; 2000. WHO. New perspective in malaria diagnosis. Geneva: World Health Organization; 2000.
14.
go back to reference Das S, Peck RB, Barney R, Jang IK, Kahn M, Zhu M, et al. Performance of an ultra-sensitive Plasmodium falciparum HRP2-based rapid diagnostic test with recombinant HRP2, culture parasites, and archived whole blood samples. Malar J. 2018;17:118.PubMedPubMedCentralCrossRef Das S, Peck RB, Barney R, Jang IK, Kahn M, Zhu M, et al. Performance of an ultra-sensitive Plasmodium falciparum HRP2-based rapid diagnostic test with recombinant HRP2, culture parasites, and archived whole blood samples. Malar J. 2018;17:118.PubMedPubMedCentralCrossRef
15.
go back to reference Das S, Jang IK, Barney B, Peck R, Rek JC, Arinaitwe E, et al. Performance of a high-sensitivity rapid diagnostic test for Plasmodium falciparum malaria in asymptomatic individuals from Uganda and Myanmar and naive human challenge infections. Am J Trop Med Hyg. 2017;97:1540–50.PubMedPubMedCentralCrossRef Das S, Jang IK, Barney B, Peck R, Rek JC, Arinaitwe E, et al. Performance of a high-sensitivity rapid diagnostic test for Plasmodium falciparum malaria in asymptomatic individuals from Uganda and Myanmar and naive human challenge infections. Am J Trop Med Hyg. 2017;97:1540–50.PubMedPubMedCentralCrossRef
16.
go back to reference Program for Appropriate Technology in Health. Project diameter—enhanced visual parasite detection; 2014. Program for Appropriate Technology in Health. Project diameter—enhanced visual parasite detection; 2014.
18.
go back to reference Hathiwala R, Mehta PR, Nataraj G, Hathiwala S. LED fluorescence microscopy: novel method for malaria diagnosis compared with routine methods. J Infect Public Health. 2016;10:1–5. Hathiwala R, Mehta PR, Nataraj G, Hathiwala S. LED fluorescence microscopy: novel method for malaria diagnosis compared with routine methods. J Infect Public Health. 2016;10:1–5.
19.
go back to reference Wongsrichanalai C, Barcus MJ, Muth S, Sutamihardja A, Wernsdorfer WH. A review of malaria diagnostic tools: microscopy and rapid diagnostic test (RDT). Am J Trop Med Hyg. 2007;77:119–27.PubMedCrossRef Wongsrichanalai C, Barcus MJ, Muth S, Sutamihardja A, Wernsdorfer WH. A review of malaria diagnostic tools: microscopy and rapid diagnostic test (RDT). Am J Trop Med Hyg. 2007;77:119–27.PubMedCrossRef
20.
go back to reference Feleke DG, Tarko S, Hadush H. Performance comparison of CareStart™ HRP2/pLDH combo rapid malaria test with light microscopy in north-western Tigray, Ethiopia: a cross-sectional study. BMC Infect Dis. 2017;17:399.PubMedPubMedCentralCrossRef Feleke DG, Tarko S, Hadush H. Performance comparison of CareStart™ HRP2/pLDH combo rapid malaria test with light microscopy in north-western Tigray, Ethiopia: a cross-sectional study. BMC Infect Dis. 2017;17:399.PubMedPubMedCentralCrossRef
21.
go back to reference Jimenez A, Rees-Channer RR, Perera R, Gamboa D, Chiodini PL, Gonzalez IJ, et al. Analytical sensitivity of current best-in-class malaria rapid diagnostic tests. Malar J. 2017;16:128.PubMedPubMedCentralCrossRef Jimenez A, Rees-Channer RR, Perera R, Gamboa D, Chiodini PL, Gonzalez IJ, et al. Analytical sensitivity of current best-in-class malaria rapid diagnostic tests. Malar J. 2017;16:128.PubMedPubMedCentralCrossRef
22.
go back to reference UNITAID. Malaria diagnostics technology and market landscape 2015; 2015. UNITAID. Malaria diagnostics technology and market landscape 2015; 2015.
23.
go back to reference Hopkins H, Gonzalez IJ, Polley SD, Angutoko P, Ategeka J, Asiimwe C, et al. Highly sensitive detection of malaria parasitemia in a malaria-endemic setting: performance of a new loop-mediated isothermal amplification kit in a remote clinic in Uganda. J Infect Dis. 2013;208:645–52.PubMedPubMedCentralCrossRef Hopkins H, Gonzalez IJ, Polley SD, Angutoko P, Ategeka J, Asiimwe C, et al. Highly sensitive detection of malaria parasitemia in a malaria-endemic setting: performance of a new loop-mediated isothermal amplification kit in a remote clinic in Uganda. J Infect Dis. 2013;208:645–52.PubMedPubMedCentralCrossRef
24.
25.
go back to reference Erdman LK, Kain KC. Molecular diagnostic and surveillance tools for global malaria control. Travel Med Infect Dis. 2008;6:82–99.PubMedCrossRef Erdman LK, Kain KC. Molecular diagnostic and surveillance tools for global malaria control. Travel Med Infect Dis. 2008;6:82–99.PubMedCrossRef
26.
go back to reference Hofmann N, Mwingira F, Shekalaghe S, Robinson LJ, Mueller I, Felger I. Ultra-sensitive detection of Plasmodium falciparum by amplification of multi-copy subtelomeric targets. PLoS Med. 2015;12:e1001788.PubMedPubMedCentralCrossRef Hofmann N, Mwingira F, Shekalaghe S, Robinson LJ, Mueller I, Felger I. Ultra-sensitive detection of Plasmodium falciparum by amplification of multi-copy subtelomeric targets. PLoS Med. 2015;12:e1001788.PubMedPubMedCentralCrossRef
27.
go back to reference WHO. New perspectives malaria diagnosis. Geneva: World Health Organization; 2000. WHO. New perspectives malaria diagnosis. Geneva: World Health Organization; 2000.
28.
go back to reference Ezennia IJ, Nduka SO, Ekwunife OI. Cost benefit analysis of malaria rapid diagnostic test: the perspective of Nigerian community pharmacists. Malar J. 2017;16:7.PubMedPubMedCentralCrossRef Ezennia IJ, Nduka SO, Ekwunife OI. Cost benefit analysis of malaria rapid diagnostic test: the perspective of Nigerian community pharmacists. Malar J. 2017;16:7.PubMedPubMedCentralCrossRef
29.
go back to reference Bisoffi Z, Sirima SB, Meheus F, Lodesani C, Gobbi F, Angheben A, et al. Strict adherence to malaria rapid test results might lead to a neglect of other dangerous diseases: a cost benefit analysis from Burkina Faso. Malar J. 2011;10:226.PubMedPubMedCentralCrossRef Bisoffi Z, Sirima SB, Meheus F, Lodesani C, Gobbi F, Angheben A, et al. Strict adherence to malaria rapid test results might lead to a neglect of other dangerous diseases: a cost benefit analysis from Burkina Faso. Malar J. 2011;10:226.PubMedPubMedCentralCrossRef
30.
go back to reference Kattenberg JH, Tahita CM, Versteeg IAJ, Tinto H, Traoré Coulibaly M, D’Alessandro U, et al. Evaluation of antigen detection tests, microscopy, and polymerase chain reaction for diagnosis of malaria in peripheral blood in asymptomatic pregnant women in Nanoro, Burkina Faso. Am J Trop Med Hyg. 2012;87:251–6.PubMedPubMedCentralCrossRef Kattenberg JH, Tahita CM, Versteeg IAJ, Tinto H, Traoré Coulibaly M, D’Alessandro U, et al. Evaluation of antigen detection tests, microscopy, and polymerase chain reaction for diagnosis of malaria in peripheral blood in asymptomatic pregnant women in Nanoro, Burkina Faso. Am J Trop Med Hyg. 2012;87:251–6.PubMedPubMedCentralCrossRef
31.
go back to reference WHO/FIND/CDC. Malaria rapid diagnostic test performance round 1–7 (2008–2016). Geneva: World Health Organization; 2017. WHO/FIND/CDC. Malaria rapid diagnostic test performance round 1–7 (2008–2016). Geneva: World Health Organization; 2017.
32.
go back to reference Krampa F, Aniweh Y, Awandare G, Kanyong P. Recent progress in the development of diagnostic tests for malaria. Diagnostics. 2017;7:54.PubMedCentralCrossRef Krampa F, Aniweh Y, Awandare G, Kanyong P. Recent progress in the development of diagnostic tests for malaria. Diagnostics. 2017;7:54.PubMedCentralCrossRef
33.
go back to reference Mathema VB, Na-Bangchang K. A brief review on biomarkers and proteomic approach for malaria research. Asian Pac J Trop Med. 2015;8:253–62.PubMedCrossRef Mathema VB, Na-Bangchang K. A brief review on biomarkers and proteomic approach for malaria research. Asian Pac J Trop Med. 2015;8:253–62.PubMedCrossRef
34.
go back to reference Jain P, Chakma B, Patra S, Goswami P. Potential biomarkers and their applications for rapid and reliable detection of malaria. BioMed Res Int. 2014;2014:852645.PubMedPubMedCentralCrossRef Jain P, Chakma B, Patra S, Goswami P. Potential biomarkers and their applications for rapid and reliable detection of malaria. BioMed Res Int. 2014;2014:852645.PubMedPubMedCentralCrossRef
35.
go back to reference Sajid M, Kawde AN, Daud M. Designs, formats and applications of lateral flow assay: a literature review. J Saudi Chem Soc. 2015;19:689–705.CrossRef Sajid M, Kawde AN, Daud M. Designs, formats and applications of lateral flow assay: a literature review. J Saudi Chem Soc. 2015;19:689–705.CrossRef
36.
go back to reference Credou J, Volland H, Berthelot T. Photolinker-free photoimmobilization of antibodies onto cellulose for the preparation of immunoassay membranes. J Mater Chem B. 2015;3:1079–88.CrossRef Credou J, Volland H, Berthelot T. Photolinker-free photoimmobilization of antibodies onto cellulose for the preparation of immunoassay membranes. J Mater Chem B. 2015;3:1079–88.CrossRef
37.
go back to reference Posthuma-Trumpie GA, Korf J, Van Amerongen A. Lateral flow (immuno)assay: its strengths, weaknesses, opportunities and threats. A literature survey. Anal Bioanal Chem. 2009;393:569–82.PubMedCrossRef Posthuma-Trumpie GA, Korf J, Van Amerongen A. Lateral flow (immuno)assay: its strengths, weaknesses, opportunities and threats. A literature survey. Anal Bioanal Chem. 2009;393:569–82.PubMedCrossRef
38.
go back to reference UNITAID. Malaria diagnostics technology and market landscape. Geneva: World Health Organization; 2016. UNITAID. Malaria diagnostics technology and market landscape. Geneva: World Health Organization; 2016.
54.
go back to reference Fook Kong T, Ye W, Peng WK, Wei Hou H, Marcos Preiser PR, et al. Enhancing malaria diagnosis through microfluidic cell enrichment and magnetic resonance relaxometry detection. Sci Rep. 2015;5:11425.PubMedCentralCrossRef Fook Kong T, Ye W, Peng WK, Wei Hou H, Marcos Preiser PR, et al. Enhancing malaria diagnosis through microfluidic cell enrichment and magnetic resonance relaxometry detection. Sci Rep. 2015;5:11425.PubMedCentralCrossRef
55.
go back to reference Newman DM, Heptinstall J, Matelon RJ, Savage L, Wears ML, Beddow J, et al. A magneto-optic route toward the in vivo diagnosis of malaria: preliminary results and preclinical trial data. Biophys J. 2008;95:994–1000.PubMedPubMedCentralCrossRef Newman DM, Heptinstall J, Matelon RJ, Savage L, Wears ML, Beddow J, et al. A magneto-optic route toward the in vivo diagnosis of malaria: preliminary results and preclinical trial data. Biophys J. 2008;95:994–1000.PubMedPubMedCentralCrossRef
56.
go back to reference Lukianova-Hleb E, Bezek S, Szigeti R, Khodarev A, Kelley T, Hurrell A, et al. Transdermal diagnosis of malaria using vapor nanobubbles. Emerg Infect Dis. 2015;21:1122–7.PubMedPubMedCentralCrossRef Lukianova-Hleb E, Bezek S, Szigeti R, Khodarev A, Kelley T, Hurrell A, et al. Transdermal diagnosis of malaria using vapor nanobubbles. Emerg Infect Dis. 2015;21:1122–7.PubMedPubMedCentralCrossRef
57.
go back to reference Orbán Á, Butykai Á, Molnár A, Pröhle Z, Fülöp G, Zelles T, et al. Evaluation of a novel magneto-optical method for the detection of malaria parasites. PLoS ONE. 2014;9:1–8. Orbán Á, Butykai Á, Molnár A, Pröhle Z, Fülöp G, Zelles T, et al. Evaluation of a novel magneto-optical method for the detection of malaria parasites. PLoS ONE. 2014;9:1–8.
58.
go back to reference Vallooran JJ, Handschin S, Pillai SM, Vetter BN, Rusch S, Beck H-PP, et al. Lipidic cubic phases as a versatile platform for the rapid detection of biomarkers, viruses, bacteria, and parasites. Adv Funct Mater. 2015;26:1–10. Vallooran JJ, Handschin S, Pillai SM, Vetter BN, Rusch S, Beck H-PP, et al. Lipidic cubic phases as a versatile platform for the rapid detection of biomarkers, viruses, bacteria, and parasites. Adv Funct Mater. 2015;26:1–10.
59.
go back to reference Kelly M, Su CY, Schaber C, Crowley JR, Hsu FF, Carlson JR, et al. Malaria parasites produce volatile mosquito attractants. Am Soc Microbiol. 2015;6:1–6. Kelly M, Su CY, Schaber C, Crowley JR, Hsu FF, Carlson JR, et al. Malaria parasites produce volatile mosquito attractants. Am Soc Microbiol. 2015;6:1–6.
60.
go back to reference Berna AZ, McCarthy JS, Wang RX, Saliba KJ, Bravo FG, Cassells J, et al. Analysis of breath specimens for biomarkers of Plasmodium falciparum infection. J Infect Dis. 2015;212:1120–8.PubMedPubMedCentralCrossRef Berna AZ, McCarthy JS, Wang RX, Saliba KJ, Bravo FG, Cassells J, et al. Analysis of breath specimens for biomarkers of Plasmodium falciparum infection. J Infect Dis. 2015;212:1120–8.PubMedPubMedCentralCrossRef
62.
go back to reference Moonen B, Cohen JM, Snow RW, Slutsker L, Drakeley C, Smith DL, et al. Operational strategies to achieve and maintain malaria elimination. Lancet. 2010;376:1592–603.PubMedPubMedCentralCrossRef Moonen B, Cohen JM, Snow RW, Slutsker L, Drakeley C, Smith DL, et al. Operational strategies to achieve and maintain malaria elimination. Lancet. 2010;376:1592–603.PubMedPubMedCentralCrossRef
64.
go back to reference Gillet P, Scheirlinck A, Stokx J, De Weggheleire A, Chaúque HS, Canhanga ODJV, et al. Prozone in malaria rapid diagnostics tests: how many cases are missed? Malar J. 2011;10:166.PubMedPubMedCentralCrossRef Gillet P, Scheirlinck A, Stokx J, De Weggheleire A, Chaúque HS, Canhanga ODJV, et al. Prozone in malaria rapid diagnostics tests: how many cases are missed? Malar J. 2011;10:166.PubMedPubMedCentralCrossRef
65.
go back to reference Weigl BH, Boyle DS, de los Santos T, Peck RB, Steele MS. Simplicity of use: a critical feature for widespread adoption of diagnostic technologies in low-resource settings. Expert Rev Med Devices. 2009;6:461–4.PubMedCrossRef Weigl BH, Boyle DS, de los Santos T, Peck RB, Steele MS. Simplicity of use: a critical feature for widespread adoption of diagnostic technologies in low-resource settings. Expert Rev Med Devices. 2009;6:461–4.PubMedCrossRef
66.
go back to reference Seidahmed OME, Mohamedein MMN, Elsir AA, Ali FT, Malik EFM, Ahmed ES. End-user errors in applying two malaria rapid diagnostic tests in a remote area of Sudan. Trop Med Int Health. 2008;13:406–9.PubMedCrossRef Seidahmed OME, Mohamedein MMN, Elsir AA, Ali FT, Malik EFM, Ahmed ES. End-user errors in applying two malaria rapid diagnostic tests in a remote area of Sudan. Trop Med Int Health. 2008;13:406–9.PubMedCrossRef
67.
go back to reference Albertini A, Lee E, Coulibaly SO, Sleshi M, Faye B, Mationg ML, et al. Malaria rapid diagnostic test transport and storage conditions in Burkina Faso, Senegal, Ethiopia and the Philippines. Malar J. 2012;11:406.PubMedPubMedCentralCrossRef Albertini A, Lee E, Coulibaly SO, Sleshi M, Faye B, Mationg ML, et al. Malaria rapid diagnostic test transport and storage conditions in Burkina Faso, Senegal, Ethiopia and the Philippines. Malar J. 2012;11:406.PubMedPubMedCentralCrossRef
69.
go back to reference Gervais L, De Rooij N, Delamarche E. Microfluidic chips for point-of-care immunodiagnostics. Adv Healthc Mater. 2011;23:151–76.CrossRef Gervais L, De Rooij N, Delamarche E. Microfluidic chips for point-of-care immunodiagnostics. Adv Healthc Mater. 2011;23:151–76.CrossRef
70.
go back to reference Yager P, Edwards T, Fu E, Helton K, Nelson K, Tam MR, et al. Microfluidic diagnostic technologies for global public health. Nature. 2006;442:412–8.PubMedCrossRef Yager P, Edwards T, Fu E, Helton K, Nelson K, Tam MR, et al. Microfluidic diagnostic technologies for global public health. Nature. 2006;442:412–8.PubMedCrossRef
71.
go back to reference Hawkins K, Weigl B. Microfluidic diagnostics for low-resource settings. In: Proceedings of the SPIE; 2010. p. 75930L–75930L-15. Hawkins K, Weigl B. Microfluidic diagnostics for low-resource settings. In: Proceedings of the SPIE; 2010. p. 75930L–75930L-15.
72.
go back to reference Laksanasopin T, Guo TW, Nayak S, Sridhara AA, Xie S, Olowookere OO, et al. A smartphone dongle for diagnosis of infectious diseases at the point of care. Sci Transl Med. 2015;7:273.CrossRef Laksanasopin T, Guo TW, Nayak S, Sridhara AA, Xie S, Olowookere OO, et al. A smartphone dongle for diagnosis of infectious diseases at the point of care. Sci Transl Med. 2015;7:273.CrossRef
73.
go back to reference Zhao Y, Czilwik G, Klein V, Mitsakakis K, Zengerle R, Paust N. C-reactive protein and interleukin 6 microfluidic immunoassays with on-chip pre-stored reagents and centrifugo-pneumatic liquid control. Lab Chip. 2017;17:1666–77.PubMedCrossRef Zhao Y, Czilwik G, Klein V, Mitsakakis K, Zengerle R, Paust N. C-reactive protein and interleukin 6 microfluidic immunoassays with on-chip pre-stored reagents and centrifugo-pneumatic liquid control. Lab Chip. 2017;17:1666–77.PubMedCrossRef
76.
go back to reference Yamada K, Shibata H, Suzuki K, Citterio D. Toward practical application of paper-based microfluidics for medical diagnostics: state-of-the-art and challenges. Lab Chip. 2017;17:1206–49.PubMedCrossRef Yamada K, Shibata H, Suzuki K, Citterio D. Toward practical application of paper-based microfluidics for medical diagnostics: state-of-the-art and challenges. Lab Chip. 2017;17:1206–49.PubMedCrossRef
77.
go back to reference Meijer HEH, Singh MK, Kang TG, Den Toonder JMJ, Anderson PD. Passive and active mixing in microfluidic devices. Macromol Symp. 2009;279:201–9.CrossRef Meijer HEH, Singh MK, Kang TG, Den Toonder JMJ, Anderson PD. Passive and active mixing in microfluidic devices. Macromol Symp. 2009;279:201–9.CrossRef
78.
go back to reference Dimov IK, Basabe-Desmonts L, Garcia-Cordero JL, Ross BM, Park Y, Ricco AJ, et al. Stand-alone self-powered integrated microfluidic blood analysis system (SIMBAS). Lab Chip. 2011;11:845–50.PubMedCrossRef Dimov IK, Basabe-Desmonts L, Garcia-Cordero JL, Ross BM, Park Y, Ricco AJ, et al. Stand-alone self-powered integrated microfluidic blood analysis system (SIMBAS). Lab Chip. 2011;11:845–50.PubMedCrossRef
79.
go back to reference Lafleur L, Stevens D, McKenzie K, Ramachandran S, Spicar-Mihalic P, Singhal M, et al. Progress toward multiplexed sample-to-result detection in low resource settings using microfluidic immunoassay cards. Lab Chip. 2012;12:1119–27.PubMedCrossRef Lafleur L, Stevens D, McKenzie K, Ramachandran S, Spicar-Mihalic P, Singhal M, et al. Progress toward multiplexed sample-to-result detection in low resource settings using microfluidic immunoassay cards. Lab Chip. 2012;12:1119–27.PubMedCrossRef
80.
81.
go back to reference Bourquin Y, Reboud J, Wilson R, Zhang Y, Cooper JM. Integrated immunoassay using tuneable surface acoustic waves and lensfree detection. Lab Chip. 2011;11:2725–30.PubMedCrossRef Bourquin Y, Reboud J, Wilson R, Zhang Y, Cooper JM. Integrated immunoassay using tuneable surface acoustic waves and lensfree detection. Lab Chip. 2011;11:2725–30.PubMedCrossRef
82.
go back to reference Chen C-F, Liu J, Chang C-C, DeVoe DL. High-pressure on-chip mechanical valves for thermoplastic microfluidic devices. Lab Chip. 2009;9:3511–6.PubMedCrossRef Chen C-F, Liu J, Chang C-C, DeVoe DL. High-pressure on-chip mechanical valves for thermoplastic microfluidic devices. Lab Chip. 2009;9:3511–6.PubMedCrossRef
83.
go back to reference Nam J, Huang H, Lim H, Lim C, Shin S. Magnetic separation of malaria-infected red blood cells in various developmental stages. Anal Chem. 2013;85:7316–23.PubMedCrossRef Nam J, Huang H, Lim H, Lim C, Shin S. Magnetic separation of malaria-infected red blood cells in various developmental stages. Anal Chem. 2013;85:7316–23.PubMedCrossRef
84.
go back to reference Juncker D, Schmid H, Drechsler U, Wolf H, Wolf M, Michel B, et al. Autonomous microfluidic capillary system. Anal Chem. 2002;74:6139–44.PubMedCrossRef Juncker D, Schmid H, Drechsler U, Wolf H, Wolf M, Michel B, et al. Autonomous microfluidic capillary system. Anal Chem. 2002;74:6139–44.PubMedCrossRef
85.
go back to reference Hugo S, Land K, Madou M, Kido H. A centrifugal microfluidic platform for point-of-care diagnostic applications. S Afr J Sci. 2014;110:1–7.CrossRef Hugo S, Land K, Madou M, Kido H. A centrifugal microfluidic platform for point-of-care diagnostic applications. S Afr J Sci. 2014;110:1–7.CrossRef
86.
87.
go back to reference Juul S, Nielsen CJF, Labouriau R, Roy A, Tesauro C, Jensen PW, et al. Droplet microfluidics platform for highly sensitive and quantitative detection of malaria-causing Plasmodium parasites based on enzyme activity measurement. ACS Nano. 2012;6:10676–83.PubMedPubMedCentralCrossRef Juul S, Nielsen CJF, Labouriau R, Roy A, Tesauro C, Jensen PW, et al. Droplet microfluidics platform for highly sensitive and quantitative detection of malaria-causing Plasmodium parasites based on enzyme activity measurement. ACS Nano. 2012;6:10676–83.PubMedPubMedCentralCrossRef
88.
go back to reference Warkiani ME, Tay AKP, Khoo BL, Xiaofeng X, Han J, Lim CT. Malaria detection using inertial microfluidics. Lab Chip. 2015;15:1101–9.PubMedCrossRef Warkiani ME, Tay AKP, Khoo BL, Xiaofeng X, Han J, Lim CT. Malaria detection using inertial microfluidics. Lab Chip. 2015;15:1101–9.PubMedCrossRef
89.
go back to reference Birch CM, Hou HW, Han J, Niles JC. Identification of malaria parasite-infected red blood cell surface aptamers by inertial microfluidic SELEX (I-SELEX). Sci Rep. 2015;5:11347.PubMedPubMedCentralCrossRef Birch CM, Hou HW, Han J, Niles JC. Identification of malaria parasite-infected red blood cell surface aptamers by inertial microfluidic SELEX (I-SELEX). Sci Rep. 2015;5:11347.PubMedPubMedCentralCrossRef
90.
go back to reference Geislinger TM, Chan S, Moll K, Wixforth A, Wahlgren M, Franke T. Label-free microfluidic enrichment of ring-stage Plasmodium falciparum-infected red blood cells using non-inertial hydrodynamic lift. Malar J. 2014;13:375.PubMedPubMedCentralCrossRef Geislinger TM, Chan S, Moll K, Wixforth A, Wahlgren M, Franke T. Label-free microfluidic enrichment of ring-stage Plasmodium falciparum-infected red blood cells using non-inertial hydrodynamic lift. Malar J. 2014;13:375.PubMedPubMedCentralCrossRef
91.
go back to reference Du E, Dao M, Suresh S. Quantitative biomechanics of healthy and diseased human red blood cells using dielectrophoresis in a microfluidic system. Extrem Mech Lett. 2014;1:35–41.CrossRef Du E, Dao M, Suresh S. Quantitative biomechanics of healthy and diseased human red blood cells using dielectrophoresis in a microfluidic system. Extrem Mech Lett. 2014;1:35–41.CrossRef
92.
go back to reference Banoth E, Kasula VK, Jagannadh VK, Gorthi SS. Optofluidic single-cell absorption flow analyzer for point-of-care diagnosis of malaria. J Biophotonics. 2016;9:610–8.PubMedCrossRef Banoth E, Kasula VK, Jagannadh VK, Gorthi SS. Optofluidic single-cell absorption flow analyzer for point-of-care diagnosis of malaria. J Biophotonics. 2016;9:610–8.PubMedCrossRef
93.
go back to reference Horning MP, Delahunt CB, Singh SR, Garing SH, Nichols KP. A paper microfluidic cartridge for automated staining of malaria parasites with an optically transparent microscopy window. Lab Chip. 2014;14:2040.PubMedCrossRef Horning MP, Delahunt CB, Singh SR, Garing SH, Nichols KP. A paper microfluidic cartridge for automated staining of malaria parasites with an optically transparent microscopy window. Lab Chip. 2014;14:2040.PubMedCrossRef
94.
go back to reference Peng WK, Kong TF, Ng CS, Chen L, Huang Y, Bhagat AAS, et al. Micromagnetic resonance relaxometry for rapid label-free malaria diagnosis. Nat Med. 2014;20:1069–73.PubMedCrossRef Peng WK, Kong TF, Ng CS, Chen L, Huang Y, Bhagat AAS, et al. Micromagnetic resonance relaxometry for rapid label-free malaria diagnosis. Nat Med. 2014;20:1069–73.PubMedCrossRef
95.
go back to reference Baratchi S, Khoshmanesh K, Sacristán C, Depoil D, Wlodkowic D, McIntyre P, et al. Immunology on chip: promises and opportunities. Biotechnol Adv. 2014;32:333–46.PubMedCrossRef Baratchi S, Khoshmanesh K, Sacristán C, Depoil D, Wlodkowic D, McIntyre P, et al. Immunology on chip: promises and opportunities. Biotechnol Adv. 2014;32:333–46.PubMedCrossRef
96.
go back to reference Han KN, Li CA, Seong GH. Microfluidic chips for immunoassays. Annu Rev Anal Chem. 2013;6:119–41.CrossRef Han KN, Li CA, Seong GH. Microfluidic chips for immunoassays. Annu Rev Anal Chem. 2013;6:119–41.CrossRef
97.
go back to reference Xu G, Nolder D, Reboud J, Oguike MC, van Schalkwyk DA, Sutherland CJ, et al. Paper-origami-based multiplexed malaria diagnostics from whole blood. Angew Chem Int Ed. 2016;55:15250–3.CrossRef Xu G, Nolder D, Reboud J, Oguike MC, van Schalkwyk DA, Sutherland CJ, et al. Paper-origami-based multiplexed malaria diagnostics from whole blood. Angew Chem Int Ed. 2016;55:15250–3.CrossRef
98.
go back to reference Cheow LF, Ko SH, Kim SJ, Kang KH, Han J. Increasing the sensitivity of enzyme-linked immunosorbent assay using multiplexed electrokinetic concentrator. Anal Chem. 2010;82:3383–8.PubMedPubMedCentralCrossRef Cheow LF, Ko SH, Kim SJ, Kang KH, Han J. Increasing the sensitivity of enzyme-linked immunosorbent assay using multiplexed electrokinetic concentrator. Anal Chem. 2010;82:3383–8.PubMedPubMedCentralCrossRef
99.
go back to reference Yang S, Undar A, Zahn JD. A microfluidic device for continuous, real time blood plasma separation. Lab Chip. 2006;6:871–80.PubMedCrossRef Yang S, Undar A, Zahn JD. A microfluidic device for continuous, real time blood plasma separation. Lab Chip. 2006;6:871–80.PubMedCrossRef
100.
go back to reference Gascoyne P, Mahidol C, Ruchirawat M, Satayavivad J, Watcharasit P, Becker FF. Microsample preparation by dielectrophoresis: isolation of malaria. Lab Chip. 2002;2:70–5.PubMedPubMedCentralCrossRef Gascoyne P, Mahidol C, Ruchirawat M, Satayavivad J, Watcharasit P, Becker FF. Microsample preparation by dielectrophoresis: isolation of malaria. Lab Chip. 2002;2:70–5.PubMedPubMedCentralCrossRef
101.
go back to reference Wang XB, Yang J, Huang Y, Vykoukal J, Becker FF, Gascoyne PRC. Cell separation by dielectrophoretic field- flow-fractionation. Anal Chem. 2000;72:832–9.PubMedPubMedCentralCrossRef Wang XB, Yang J, Huang Y, Vykoukal J, Becker FF, Gascoyne PRC. Cell separation by dielectrophoretic field- flow-fractionation. Anal Chem. 2000;72:832–9.PubMedPubMedCentralCrossRef
102.
go back to reference Rousselet J, Markx GH, Pethig R. Separation of erythrocytes and latex beads by dielectrophoretic levitation and hyperlayer field-flow fractionation. Colloids Surfaces. 1998;140:209–16.CrossRef Rousselet J, Markx GH, Pethig R. Separation of erythrocytes and latex beads by dielectrophoretic levitation and hyperlayer field-flow fractionation. Colloids Surfaces. 1998;140:209–16.CrossRef
103.
go back to reference Macounová K, Cabrera CR, Yager P. Concentration and separation of proteins in microfluidic channels on the basis of transverse IEF. Anal Chem. 2001;73:1627–33.PubMedCrossRef Macounová K, Cabrera CR, Yager P. Concentration and separation of proteins in microfluidic channels on the basis of transverse IEF. Anal Chem. 2001;73:1627–33.PubMedCrossRef
104.
go back to reference Hulme SE, Shevkoplyas SS, Whitesides GM. Incorporation of prefabricated screw, pneumatic, and solenoid valves into microfluidic devices. Lab Chip. 2009;9:79–86.PubMedCrossRef Hulme SE, Shevkoplyas SS, Whitesides GM. Incorporation of prefabricated screw, pneumatic, and solenoid valves into microfluidic devices. Lab Chip. 2009;9:79–86.PubMedCrossRef
105.
go back to reference Park J, Sunkara V, Kim TH, Hwang H, Cho YK. Lab-on-a-disc for fully integrated multiplex immunoassays. Anal Chem. 2012;84:2133–40.PubMedCrossRef Park J, Sunkara V, Kim TH, Hwang H, Cho YK. Lab-on-a-disc for fully integrated multiplex immunoassays. Anal Chem. 2012;84:2133–40.PubMedCrossRef
106.
go back to reference Gervais L, Delamarche E. Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates. Lab Chip. 2009;9:3330–7.PubMedCrossRef Gervais L, Delamarche E. Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates. Lab Chip. 2009;9:3330–7.PubMedCrossRef
107.
go back to reference Strohmeier O, Keller M, Schwemmer F, Zehnle S, Mark D, von Stetten F, et al. Centrifugal microfluidic platforms: advanced unit operations and applications. Chem Soc Rev. 2015;44:6187–229.PubMedCrossRef Strohmeier O, Keller M, Schwemmer F, Zehnle S, Mark D, von Stetten F, et al. Centrifugal microfluidic platforms: advanced unit operations and applications. Chem Soc Rev. 2015;44:6187–229.PubMedCrossRef
108.
go back to reference Oh KW, Ahn CH. A review of microvalves. J Micromechanics Microengineering. 2006;16:R13–39.CrossRef Oh KW, Ahn CH. A review of microvalves. J Micromechanics Microengineering. 2006;16:R13–39.CrossRef
109.
go back to reference Laser DJ, Santiago JG. A review of micropumps. J Micromechanics Microengineering. 2004;14:R35–64.CrossRef Laser DJ, Santiago JG. A review of micropumps. J Micromechanics Microengineering. 2004;14:R35–64.CrossRef
110.
go back to reference Kuswandi B. Nuriman, Huskens J, Verboom W. Optical sensing systems for microfluidic devices: a review. Anal Chim Acta. 2007;601:141–55.PubMedCrossRef Kuswandi B. Nuriman, Huskens J, Verboom W. Optical sensing systems for microfluidic devices: a review. Anal Chim Acta. 2007;601:141–55.PubMedCrossRef
111.
go back to reference Wu J, Zheng G, Lee LM. Optical imaging techniques in microfluidics and their applications. Lab Chip. 2012;12:3566.PubMedCrossRef Wu J, Zheng G, Lee LM. Optical imaging techniques in microfluidics and their applications. Lab Chip. 2012;12:3566.PubMedCrossRef
112.
go back to reference Dittrich PS, Manz A. Single-molecule fluorescence detection in microfluidic channels-the Holy Grail in μTAS? Anal Bioanal Chem. 2005;382:1771–82.PubMedCrossRef Dittrich PS, Manz A. Single-molecule fluorescence detection in microfluidic channels-the Holy Grail in μTAS? Anal Bioanal Chem. 2005;382:1771–82.PubMedCrossRef
113.
go back to reference Mirasoli M, Guardigli M, Michelini E, Roda A. Recent advancements in chemical luminescence-based lab-on-chip and microfluidic platforms for bioanalysis. J Pharm Biomed Anal. 2014;87:36–52.PubMedCrossRef Mirasoli M, Guardigli M, Michelini E, Roda A. Recent advancements in chemical luminescence-based lab-on-chip and microfluidic platforms for bioanalysis. J Pharm Biomed Anal. 2014;87:36–52.PubMedCrossRef
114.
go back to reference Chin CD, Laksanasopin T, Cheung YK, Steinmiller D, Linder V, Parsa H, et al. Microfluidics-based diagnostics of infectious diseases in the developing world. Nat Med. 2011;17:1015–9.PubMedCrossRef Chin CD, Laksanasopin T, Cheung YK, Steinmiller D, Linder V, Parsa H, et al. Microfluidics-based diagnostics of infectious diseases in the developing world. Nat Med. 2011;17:1015–9.PubMedCrossRef
115.
go back to reference Petryayeva E, Krull UJ. Localized surface plasmon resonance: nanostructures, bioassays and biosensing-A review. Anal Chim Acta. 2011;706:8–24.PubMedCrossRef Petryayeva E, Krull UJ. Localized surface plasmon resonance: nanostructures, bioassays and biosensing-A review. Anal Chim Acta. 2011;706:8–24.PubMedCrossRef
116.
go back to reference Li M, Cushing SK, Wu N. Plasmon-enhanced optical sensors: a review. Analyst. 2014;140:386–406.CrossRef Li M, Cushing SK, Wu N. Plasmon-enhanced optical sensors: a review. Analyst. 2014;140:386–406.CrossRef
118.
go back to reference Kamau E, Tolbert LS, Kortepeter L, Pratt M, Nyakoe N, Muringo L, et al. Development of a highly sensitive genus-specific quantitative reverse transcriptase real-time PCR assay for detection and quantitation of Plasmodium by amplifying RNA and DNA of the 18S rRNA genes. J Clin Microbiol. 2011;49:2946–53.PubMedPubMedCentralCrossRef Kamau E, Tolbert LS, Kortepeter L, Pratt M, Nyakoe N, Muringo L, et al. Development of a highly sensitive genus-specific quantitative reverse transcriptase real-time PCR assay for detection and quantitation of Plasmodium by amplifying RNA and DNA of the 18S rRNA genes. J Clin Microbiol. 2011;49:2946–53.PubMedPubMedCentralCrossRef
119.
go back to reference Batista-dos-Santos S, Raiol M, Santos S, Cunha MG, Ribeiro-dos-Santos Â. Real-time PCR diagnosis of Plasmodium vivax among blood donors. Malar J. 2012;11:345.PubMedPubMedCentralCrossRef Batista-dos-Santos S, Raiol M, Santos S, Cunha MG, Ribeiro-dos-Santos Â. Real-time PCR diagnosis of Plasmodium vivax among blood donors. Malar J. 2012;11:345.PubMedPubMedCentralCrossRef
120.
go back to reference Liu P, Mathies RA. Integrated microfluidic systems for high-performance genetic analysis. Trends Biotechnol. 2009;27:572–81.PubMedCrossRef Liu P, Mathies RA. Integrated microfluidic systems for high-performance genetic analysis. Trends Biotechnol. 2009;27:572–81.PubMedCrossRef
121.
go back to reference Hong JW, Studer V, Hang G, Anderson WF, Quake SR. A nanoliter-scale nucleic acid processor with parallel architecture. Nat Biotechnol. 2004;22:435–9.PubMedCrossRef Hong JW, Studer V, Hang G, Anderson WF, Quake SR. A nanoliter-scale nucleic acid processor with parallel architecture. Nat Biotechnol. 2004;22:435–9.PubMedCrossRef
122.
go back to reference Timoney CF, Felder RA. Feature Article Cepheid: Expanding the boundaries for practical applications of microinstrumentation and microfluidics. J Assoc Lab Autom. 1998;3:22–6. Timoney CF, Felder RA. Feature Article Cepheid: Expanding the boundaries for practical applications of microinstrumentation and microfluidics. J Assoc Lab Autom. 1998;3:22–6.
123.
go back to reference Bruijns B, van Asten A, Tiggelaar R, Gardeniers H. Microfluidic devices for forensic DNA analysis: a review. Biosensors. 2016;6:1–35.CrossRef Bruijns B, van Asten A, Tiggelaar R, Gardeniers H. Microfluidic devices for forensic DNA analysis: a review. Biosensors. 2016;6:1–35.CrossRef
124.
125.
go back to reference Burns MA, Johnson BN, Brahmasandra SN, Handique K, Webster JR, Krishnan M, et al. An integrated nanoliter DNA analysis device. Science. 1998;282:484–7.PubMedCrossRef Burns MA, Johnson BN, Brahmasandra SN, Handique K, Webster JR, Krishnan M, et al. An integrated nanoliter DNA analysis device. Science. 1998;282:484–7.PubMedCrossRef
126.
go back to reference Mcmahon T, Van Zijl PCM, Gilad AA. Instrument-free exothermic heating with phase change temperature control for paper microfluidic devices. Proc SPIE. 2013;27:320–31. Mcmahon T, Van Zijl PCM, Gilad AA. Instrument-free exothermic heating with phase change temperature control for paper microfluidic devices. Proc SPIE. 2013;27:320–31.
127.
go back to reference Martinez AW, Phillips ST, Butte MJ, Whitesides GM. Patterned paper as a platform for inexpensive, low-volume, portable bioassays. Angew Chem Int Ed. 2007;46:1318–20.CrossRef Martinez AW, Phillips ST, Butte MJ, Whitesides GM. Patterned paper as a platform for inexpensive, low-volume, portable bioassays. Angew Chem Int Ed. 2007;46:1318–20.CrossRef
128.
go back to reference Martinez AW, Phillips ST, Carrilho E, Thomas SW III, Sindi H, Whitesides GM. Simple telemedicine for developing regions: camera phones and paper-based microfluidic devices for real-time, off-site diagnosis. Anal Chem. 2008;80:3699–707.PubMedPubMedCentralCrossRef Martinez AW, Phillips ST, Carrilho E, Thomas SW III, Sindi H, Whitesides GM. Simple telemedicine for developing regions: camera phones and paper-based microfluidic devices for real-time, off-site diagnosis. Anal Chem. 2008;80:3699–707.PubMedPubMedCentralCrossRef
129.
go back to reference Martinez AW, Phillips ST, Whitesides GM, Carrilho E. Diagnostics for the developing world: microfluidic paper-based analytical devices. Anal Chem. 2010;82:3–10.PubMedCrossRef Martinez AW, Phillips ST, Whitesides GM, Carrilho E. Diagnostics for the developing world: microfluidic paper-based analytical devices. Anal Chem. 2010;82:3–10.PubMedCrossRef
130.
go back to reference Pereira DY, Chiu RYT, Zhang SCL, Wu BM, Kamei DT. Single-step, paper-based concentration and detection of a malaria biomarker. Anal Chim Acta. 2015;882:83–9.PubMedCrossRef Pereira DY, Chiu RYT, Zhang SCL, Wu BM, Kamei DT. Single-step, paper-based concentration and detection of a malaria biomarker. Anal Chim Acta. 2015;882:83–9.PubMedCrossRef
131.
go back to reference Fu E, Liang T, Spicar-Mihalic P, Houghtaling J, Ramachandran S, Yager P. Two-dimensional paper network format that enables simple multistep assays for use in low-resource settings in the context of malaria antigen detection. Anal Chem. 2012;84:4574–9.PubMedPubMedCentralCrossRef Fu E, Liang T, Spicar-Mihalic P, Houghtaling J, Ramachandran S, Yager P. Two-dimensional paper network format that enables simple multistep assays for use in low-resource settings in the context of malaria antigen detection. Anal Chem. 2012;84:4574–9.PubMedPubMedCentralCrossRef
132.
go back to reference Handique K, Gogoi BP, Burke DT, Mastrangelo CH, Burns MA. Microfluidic flow control using selective hydrophobic patterning. In: Proceedings of SPIE—the international society for optical engineering. 1997;3224:185–95. Handique K, Gogoi BP, Burke DT, Mastrangelo CH, Burns MA. Microfluidic flow control using selective hydrophobic patterning. In: Proceedings of SPIE—the international society for optical engineering. 1997;3224:185–95.
133.
go back to reference Liu H, Crooks RM. Three-dimensional paper microfluidic devices assembled using the principles of origami. J Am Chem Soc. 2011;133:17564–6.PubMedCrossRef Liu H, Crooks RM. Three-dimensional paper microfluidic devices assembled using the principles of origami. J Am Chem Soc. 2011;133:17564–6.PubMedCrossRef
134.
go back to reference Martinez AW, Phillips ST, Whitesides GM. Three-dimensional microfluidic devices fabricated in layered paper and tape. Proc Natl Acad Sci USA. 2008;105:19606–11.PubMedCrossRef Martinez AW, Phillips ST, Whitesides GM. Three-dimensional microfluidic devices fabricated in layered paper and tape. Proc Natl Acad Sci USA. 2008;105:19606–11.PubMedCrossRef
135.
go back to reference Preechaburana P, Suska A, Filippini D. Interfacing diagnostics with consumer electronics. In: Iniewski K, Karlen W, editors. Mob. point-of-care monit. diagnostic device des. Boca Raton: CRC Press; 2014. p. 1–19. Preechaburana P, Suska A, Filippini D. Interfacing diagnostics with consumer electronics. In: Iniewski K, Karlen W, editors. Mob. point-of-care monit. diagnostic device des. Boca Raton: CRC Press; 2014. p. 1–19.
136.
go back to reference Coskun AF, Zhu H, Ozcan A. Lab on a Cellphone. In: Karlen W, Iniewski K, editors. Mob. point-of-care monit. diagnostic device des. Boca Raton: CRC Press; 2014. p. 23–42. Coskun AF, Zhu H, Ozcan A. Lab on a Cellphone. In: Karlen W, Iniewski K, editors. Mob. point-of-care monit. diagnostic device des. Boca Raton: CRC Press; 2014. p. 23–42.
137.
138.
go back to reference Stedtfeld RD, Tourlousse DM, Seyrig G, Stedtfeld TM, Kronlein M, Price S, et al. Gene-Z: a device for point of care genetic testing using a smartphone. Lab Chip. 2012;12:1454.PubMedCrossRef Stedtfeld RD, Tourlousse DM, Seyrig G, Stedtfeld TM, Kronlein M, Price S, et al. Gene-Z: a device for point of care genetic testing using a smartphone. Lab Chip. 2012;12:1454.PubMedCrossRef
139.
go back to reference Wang S, Zhao X, Khimji I, Akbas R, Qiu W, Edwards D, et al. Integration of cell phone imaging with microchip ELISA to detect ovarian cancer HE4 biomarker in urine at the point-of-care. Lab Chip. 2011;11:3411.PubMedPubMedCentralCrossRef Wang S, Zhao X, Khimji I, Akbas R, Qiu W, Edwards D, et al. Integration of cell phone imaging with microchip ELISA to detect ovarian cancer HE4 biomarker in urine at the point-of-care. Lab Chip. 2011;11:3411.PubMedPubMedCentralCrossRef
140.
142.
go back to reference You DJ, Park TS, Yoon J-Y. Cell-phone-based measurement of TSH using Mie scatter optimized lateral flow assays. Biosens Bioelectron. 2013;40:180–5.PubMedCrossRef You DJ, Park TS, Yoon J-Y. Cell-phone-based measurement of TSH using Mie scatter optimized lateral flow assays. Biosens Bioelectron. 2013;40:180–5.PubMedCrossRef
143.
go back to reference Lu Y, Shi W, Qin J, Lin B. Low cost, portable detection of gold nanoparticle-labeled microfluidic immunoassay with camera cell phone. Electrophoresis. 2009;30:579–82.PubMedCrossRef Lu Y, Shi W, Qin J, Lin B. Low cost, portable detection of gold nanoparticle-labeled microfluidic immunoassay with camera cell phone. Electrophoresis. 2009;30:579–82.PubMedCrossRef
144.
go back to reference Stemple CC, Angus SV, Park TS, Yoon J-Y. Smartphone-based optofluidic lab-on-a-chip for detecting pathogens from blood. J Lab Autom. 2014;19:35–41.PubMedCrossRef Stemple CC, Angus SV, Park TS, Yoon J-Y. Smartphone-based optofluidic lab-on-a-chip for detecting pathogens from blood. J Lab Autom. 2014;19:35–41.PubMedCrossRef
145.
go back to reference Mudanyali O, Dimitrov S, Sikora U, Pasmanabhan S, Navruz I, Ozcan A. Integrated rapid diagnostic test reader platform on a cell phone. Lab Chip. 2012;12:2678–86.PubMedPubMedCentralCrossRef Mudanyali O, Dimitrov S, Sikora U, Pasmanabhan S, Navruz I, Ozcan A. Integrated rapid diagnostic test reader platform on a cell phone. Lab Chip. 2012;12:2678–86.PubMedPubMedCentralCrossRef
146.
go back to reference Zhu H, Yaglidere O, Su T-W, Tseng D, Ozcan A. Cost-effective and compact wide-field fluorescent imaging on a cell-phone. Lab Chip. 2011;11:315–22.PubMedCrossRef Zhu H, Yaglidere O, Su T-W, Tseng D, Ozcan A. Cost-effective and compact wide-field fluorescent imaging on a cell-phone. Lab Chip. 2011;11:315–22.PubMedCrossRef
147.
go back to reference Shen L, Hagen JA, Papautsky I. Point-of-care colorimetric detection with a smartphone. Lab Chip. 2012;12:4240.PubMedCrossRef Shen L, Hagen JA, Papautsky I. Point-of-care colorimetric detection with a smartphone. Lab Chip. 2012;12:4240.PubMedCrossRef
148.
go back to reference Lee D-S, Jeon BG, Ihm C, Park J-K, Jung MY. A simple and smart telemedicine device for developing regions: a pocket-sized colorimetric reader. Lab Chip. 2011;11:120–6.PubMedCrossRef Lee D-S, Jeon BG, Ihm C, Park J-K, Jung MY. A simple and smart telemedicine device for developing regions: a pocket-sized colorimetric reader. Lab Chip. 2011;11:120–6.PubMedCrossRef
149.
go back to reference Barbosa AI, Gehlot P, Sidapra K, Edwards AD, Reis NM. Portable smartphone quantitation of prostate specific antigen (PSA) in a fluoropolymer microfluidic device. Biosens Bioelectron. 2015;70:5–14.PubMedCrossRef Barbosa AI, Gehlot P, Sidapra K, Edwards AD, Reis NM. Portable smartphone quantitation of prostate specific antigen (PSA) in a fluoropolymer microfluidic device. Biosens Bioelectron. 2015;70:5–14.PubMedCrossRef
150.
go back to reference Quinn JA, Andama A, Munabi I, Kiwanuka F. Automated blood smear analysis for mobile malaria diagnosis. In: Karlen W, Iniewski K, editors. Mob. point-of-care monit. diagnostic device des. Boca Raton: CRC Press; 2015. p. 115–31. Quinn JA, Andama A, Munabi I, Kiwanuka F. Automated blood smear analysis for mobile malaria diagnosis. In: Karlen W, Iniewski K, editors. Mob. point-of-care monit. diagnostic device des. Boca Raton: CRC Press; 2015. p. 115–31.
151.
go back to reference Mudanyali O, Tseng D, Oh C, Isikman SO, Sencan I, Bishara W, et al. Compact, light-weight and cost-effective microscope based on lensless incoherent holography for telemedicine applications. Lab Chip. 2010;10:1417–28.PubMedPubMedCentralCrossRef Mudanyali O, Tseng D, Oh C, Isikman SO, Sencan I, Bishara W, et al. Compact, light-weight and cost-effective microscope based on lensless incoherent holography for telemedicine applications. Lab Chip. 2010;10:1417–28.PubMedPubMedCentralCrossRef
152.
go back to reference Bishara W, Sikora U, Mudanyali O, Ting-Wei S, Yaglidere O, Lyckhart S, et al. Holographic pixel super resolution in portable lensless op-chip microscopy using a fiber optic array. Lab Chip. 2011;11:1276–9.PubMedPubMedCentralCrossRef Bishara W, Sikora U, Mudanyali O, Ting-Wei S, Yaglidere O, Lyckhart S, et al. Holographic pixel super resolution in portable lensless op-chip microscopy using a fiber optic array. Lab Chip. 2011;11:1276–9.PubMedPubMedCentralCrossRef
153.
go back to reference Pirnstill CW, Coté GL. Malaria diagnosis using a mobile phone polarized microscope. Sci Rep. 2015;5:1–13.CrossRef Pirnstill CW, Coté GL. Malaria diagnosis using a mobile phone polarized microscope. Sci Rep. 2015;5:1–13.CrossRef
Metadata
Title
Malaria and the ‘last’ parasite: how can technology help?
Authors
Ngoc Minh Pham
Walter Karlen
Hans-Peter Beck
Emmanuel Delamarche
Publication date
01-12-2018
Publisher
BioMed Central
Published in
Malaria Journal / Issue 1/2018
Electronic ISSN: 1475-2875
DOI
https://doi.org/10.1186/s12936-018-2408-0

Other articles of this Issue 1/2018

Malaria Journal 1/2018 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.