Published in:
Open Access
01-12-2012 | Research
The value of the cerebrospinal fluid tap test for predicting shunt effectiveness in idiopathic normal pressure hydrocephalus
Authors:
Masatsune Ishikawa, Masaaki Hashimoto, Etsuro Mori, Nobumasa Kuwana, Hiroaki Kazui
Published in:
Fluids and Barriers of the CNS
|
Issue 1/2012
Login to get access
Abstract
Background
The cerebrospinal fluid (CSF) tap test (TT) has been regarded as an important test for the prediction of shunt effectiveness in patients with suspected idiopathic normal pressure hydrocephalus (iNPH). Although its specificity and sensitivity are reportedly high, there remains some disagreement over this point. Herein, the TT as a test for predicting shunt effectiveness was investigated in our multicenter prospective study named SINPHONI and strategies to increase its predictability were examined.
Methods
One hundred suspected iNPH patients with the following entry criteria were enrolled in the study: (1) 60 to 85 years old, (2) one or more of the NPH triad signs, (3) ventriculomegaly (Evans index > 0.3), (4) high convexity tightness in coronal-section MRI, and (5) no antecedent disorders. Changes in NPH triad symptoms were assessed using the iNPH grading scale and other measures before and after removal of 30 ml lumbar CSF. A positive response to TT was pre-defined by specific improvements on the grading and other scales. A ventriculoperitoneal shunt was performed with a programmable valve. The sensitivity and specificity of the TT was calculated with a contingency table. A decision tree analysis was performed to increase the predictability of the TT.
Results
Among 100 patients, 80 were shunt responders. A statistically-significant variable between shunt responders and non-responders was CSF pressure. The changes in single variables in the iNPH grading scale after TT showed high specificity with low sensitivity. In contrast, change of the total score in the iNPH grading scale showed a relatively high sensitivity of 71.3% with specificity of 65%. A decision tree analysis revealed that using the iNPH grading scale total score and pre-shunt CSF pressure ≥ 15 cmH20, sensitivity increased to 82.5%, without a decrease in specificity.
Conclusions
The sensitivity and specificity of the TT for predicting shunt responsiveness were optimum when improvement on any iNPH grading scale was combined with CSF pressure ≥ 15 cmH20. To increase the sensitivity of the TT, further effort is necessary.
Trial Registration
This study is registered with ClinicalTrials.gov, with the number
NCT00221091.