Published in: BMC Anesthesiology 1/2013

Open Access 01-12-2013 | Research article

The increase of vasomotor tone avoids the ability of the dynamic preload indicators to estimate fluid responsiveness

Authors: Juan P Bouchacourt, Juan A Riva, Juan C Grignola

Published in: BMC Anesthesiology | Issue 1/2013

Login to get access

Abstract

Background

The use of vasoconstrictor can affect the dynamic indices to predict fluid responsiveness. We investigate the effects of an increase of vascular tone on dynamic variables of fluid responsiveness in a rabbit model of hemorrhage, and to examine the ability of the arterial pressure surrogates dynamic indices to track systolic volume variation (SVV) during hypovolemia under increased vasomotor tone.

Methods

Eighteen anesthetized and mechanically ventilated rabbits were studied during normovolemia (BL) and after blood progressive removal (15 mL/kg, BW). Other two sets of data were obtained during PHE infusion with normovolemia (BL + PHE) and during hypovolemia (BW + PHE). We measured central venous and left ventricular (LV) pressures and infra diaphragmatic aortic blood flow (AoF) and pressure. Pulse pressure variation (PPV), systolic pressure variation (SPV) and SVV were estimated manually by the variation of beat-to-beat PP, SP and SV, respectively. We also calculated PPVapnea as 100 × (PPmax-PPmin)/PP during apnea. The vasomotor tone was estimated by total peripheral resistance (TPR = mean aortic pressure/mean AoF), dynamic arterial elastance (Eadyn = PPV/SVV) and arterial compliance (C = SV/PP). We assessed LV preload by LV end-diastolic pressure (LVEDP). We compared the trending abilities between SVV and pressure surrogate indices using four-quadrant plots and polar plots.

Results

Baseline PPV, SPV, PPVapnea, and SVV increased significantly during hemorrhage, with a decrease of AoF (P < 0.05). PHE induced significant TPR and Eadyn increase and C decrease in bled animals, and a further decrease in AoF with a significant decrease of all dynamic indices. There was a significant correlation between SVV and PPV, PPVapnea and SPV in normal vasomotor tone (r2 ≥ 0.5). The concordance rate was 91%, 95% and 76% between SVV and PPV, PPVapnea and SPV, respectively, in accordance with the polar plot analysis. During PHE infusion, there was no correlation between SVV and its surrogates, and both four-quadrant plot and polar plot showed poor trending.

Conclusion

In this animal model of hemorrhage and increased vasomotor tone induced by phenylephrine the ability of dynamic indices to predict fluid responsiveness seems to be impaired, masking the true fluid loss. Moreover, the arterial pressure surrogates have not the reliable trending ability against SVV.
Appendix
Available only for authorised users
Literature
1.
go back to reference Gan TJ, Soppitt A: Maroof M, el-Moalem H, Robertson KM, Moretti E, Dwane P, Glass PS: Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology. 2002, 97: 820-826. 10.1097/00000542-200210000-00012.CrossRefPubMed Gan TJ, Soppitt A: Maroof M, el-Moalem H, Robertson KM, Moretti E, Dwane P, Glass PS: Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology. 2002, 97: 820-826. 10.1097/00000542-200210000-00012.CrossRefPubMed
2.
go back to reference Lopes MR, Oliveira MA, Pereira VSO, Lemos IPB, Auler JOC, Michard F: Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial. Crit Care. 2007, 11: R100-10.1186/cc6117.CrossRefPubMedPubMedCentral Lopes MR, Oliveira MA, Pereira VSO, Lemos IPB, Auler JOC, Michard F: Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial. Crit Care. 2007, 11: R100-10.1186/cc6117.CrossRefPubMedPubMedCentral
3.
go back to reference Hamilton MA, Cecconi M, Rhodes A: A systematic review and meta-analysis on the use of preoperative hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients. Anesth Analg. 2011, 112: 1392-1402. 10.1213/ANE.0b013e3181eeaae5.CrossRefPubMed Hamilton MA, Cecconi M, Rhodes A: A systematic review and meta-analysis on the use of preoperative hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients. Anesth Analg. 2011, 112: 1392-1402. 10.1213/ANE.0b013e3181eeaae5.CrossRefPubMed
4.
go back to reference Michard F, Teboul JL: Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest. 2002, 121: 2000-2008. 10.1378/chest.121.6.2000.CrossRefPubMed Michard F, Teboul JL: Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest. 2002, 121: 2000-2008. 10.1378/chest.121.6.2000.CrossRefPubMed
5.
go back to reference Renner J, Scholz J, Bein B: Monitoring fluid therapy. Best Pract Res Clin Anaesthesiol. 2009, 23: 159-171. 10.1016/j.bpa.2008.12.001.CrossRefPubMed Renner J, Scholz J, Bein B: Monitoring fluid therapy. Best Pract Res Clin Anaesthesiol. 2009, 23: 159-171. 10.1016/j.bpa.2008.12.001.CrossRefPubMed
6.
go back to reference Cannesson M: Arterial pressure variation and goal-directed fluid therapy. J Cardiothorac Vasc Anesth. 2010, 24: 487-497. 10.1053/j.jvca.2009.10.008.CrossRefPubMed Cannesson M: Arterial pressure variation and goal-directed fluid therapy. J Cardiothorac Vasc Anesth. 2010, 24: 487-497. 10.1053/j.jvca.2009.10.008.CrossRefPubMed
7.
go back to reference Mesquida J, Kim HK, Pinsky MR: Effect of tidal volume, intrathoracic pressure, and cardiac contractility on variations in pulse pressure, stroke volume, and intrathoracic blood volume. Intensive Care Med. 2011, 37: 1672-1679. 10.1007/s00134-011-2304-3.CrossRefPubMed Mesquida J, Kim HK, Pinsky MR: Effect of tidal volume, intrathoracic pressure, and cardiac contractility on variations in pulse pressure, stroke volume, and intrathoracic blood volume. Intensive Care Med. 2011, 37: 1672-1679. 10.1007/s00134-011-2304-3.CrossRefPubMed
8.
go back to reference Perel A, Pizov R, Cotov S: Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology. 1987, 67: 498-502. 10.1097/00000542-198710000-00009.CrossRefPubMed Perel A, Pizov R, Cotov S: Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology. 1987, 67: 498-502. 10.1097/00000542-198710000-00009.CrossRefPubMed
9.
go back to reference Berkenstadt H, Friedman Z, Preisman S, Keidan I, Livingstone D, Perel A: Pulse pressure and stroke volume variations during severe haemorrhage in ventilated dogs. Br J Anesth. 2005, 96: 721-726.CrossRef Berkenstadt H, Friedman Z, Preisman S, Keidan I, Livingstone D, Perel A: Pulse pressure and stroke volume variations during severe haemorrhage in ventilated dogs. Br J Anesth. 2005, 96: 721-726.CrossRef
10.
go back to reference Michard F: Stroke volume variation: from applied physiology to improved outcomes. Crit Care Med. 2011, 39: 402-403. 10.1097/CCM.0b013e318205c0a6.CrossRefPubMed Michard F: Stroke volume variation: from applied physiology to improved outcomes. Crit Care Med. 2011, 39: 402-403. 10.1097/CCM.0b013e318205c0a6.CrossRefPubMed
11.
go back to reference Marik PE, Cavallazzi R, Vasu T, Hirani A: Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients. A systematic review of the literature. Crit Care Med. 2009, 37: 2642-2647. 10.1097/CCM.0b013e3181a590da.CrossRefPubMed Marik PE, Cavallazzi R, Vasu T, Hirani A: Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients. A systematic review of the literature. Crit Care Med. 2009, 37: 2642-2647. 10.1097/CCM.0b013e3181a590da.CrossRefPubMed
12.
go back to reference Lansdorp B, Lemson J, van Putten MJAM, de Keijzer A, van der Hoeven JG, Pickkers P: Dynamic indices do not predict volume responsiveness in routine clinical practice. Br J Anesth. 2012, 108: 395-401. 10.1093/bja/aer411.CrossRef Lansdorp B, Lemson J, van Putten MJAM, de Keijzer A, van der Hoeven JG, Pickkers P: Dynamic indices do not predict volume responsiveness in routine clinical practice. Br J Anesth. 2012, 108: 395-401. 10.1093/bja/aer411.CrossRef
13.
go back to reference Nouira S, Elatrous S, Dimassi S, Besbes L, Boukef R, Mohamed B, Abroug F: Effects of norepinephrine on static and dynamic preload indicators in experimental hemorrhagic shock. Crit Care Med. 2005, 33: 2339-2343. 10.1097/01.CCM.0000182801.48137.13.CrossRefPubMed Nouira S, Elatrous S, Dimassi S, Besbes L, Boukef R, Mohamed B, Abroug F: Effects of norepinephrine on static and dynamic preload indicators in experimental hemorrhagic shock. Crit Care Med. 2005, 33: 2339-2343. 10.1097/01.CCM.0000182801.48137.13.CrossRefPubMed
14.
go back to reference Renner J, Meybohm P, Hanss R, Gruenewald M, Scholz J, Bein B: Effects of norepinephrine on dynamic variables of fluid responsiveness during hemorrhage and after resuscitation in a pediatric porcine model. Pediatric Anesth. 2009, 19: 688-694. 10.1111/j.1460-9592.2009.03017.x.CrossRef Renner J, Meybohm P, Hanss R, Gruenewald M, Scholz J, Bein B: Effects of norepinephrine on dynamic variables of fluid responsiveness during hemorrhage and after resuscitation in a pediatric porcine model. Pediatric Anesth. 2009, 19: 688-694. 10.1111/j.1460-9592.2009.03017.x.CrossRef
15.
go back to reference Kubitz JC, Forkl S, Annecke T, Kronas N, Goetz AE, Reuter DA: Systolic pressure variation and pulse pressure variation during modifications of arterial pressure. Intensive Care Med. 2008, 34: 1520-1524. 10.1007/s00134-008-1114-8.CrossRefPubMed Kubitz JC, Forkl S, Annecke T, Kronas N, Goetz AE, Reuter DA: Systolic pressure variation and pulse pressure variation during modifications of arterial pressure. Intensive Care Med. 2008, 34: 1520-1524. 10.1007/s00134-008-1114-8.CrossRefPubMed
16.
go back to reference Sakka SG, Becher L, Kozieras J, van Hout N: Effects of changes in blood pressure and airway pressures on parameters of fluid responsiveness. Eur J Anesth. 2009, 26: 322-327. 10.1097/EJA.0b013e32831ac31b.CrossRef Sakka SG, Becher L, Kozieras J, van Hout N: Effects of changes in blood pressure and airway pressures on parameters of fluid responsiveness. Eur J Anesth. 2009, 26: 322-327. 10.1097/EJA.0b013e32831ac31b.CrossRef
17.
go back to reference Wajima Z, Shiga T, Imanaga K, Inoue T: Do induced hypertension and hypotension affect stroke volume variation in man?. J Clin Anesth. 2012, 24: 207-211. 10.1016/j.jclinane.2011.07.015.CrossRefPubMed Wajima Z, Shiga T, Imanaga K, Inoue T: Do induced hypertension and hypotension affect stroke volume variation in man?. J Clin Anesth. 2012, 24: 207-211. 10.1016/j.jclinane.2011.07.015.CrossRefPubMed
18.
go back to reference Hadian M, Severyn DA, Pinsky MR: The effects of vasoactive drugs on pulse pressure and stroke volume variation in postoperative ventilated patients. J Crit Care. 2011, 26: 328-e1–e8CrossRefPubMed Hadian M, Severyn DA, Pinsky MR: The effects of vasoactive drugs on pulse pressure and stroke volume variation in postoperative ventilated patients. J Crit Care. 2011, 26: 328-e1–e8CrossRefPubMed
19.
go back to reference Hummler HD, Pohlandt F, Franz AR: Pulse oximetry during low perfusion caused by emerging pneumonia and sepsis in rabbits. Crit Care Med. 2002, 30: 2501-2508. 10.1097/00003246-200211000-00016.CrossRefPubMed Hummler HD, Pohlandt F, Franz AR: Pulse oximetry during low perfusion caused by emerging pneumonia and sepsis in rabbits. Crit Care Med. 2002, 30: 2501-2508. 10.1097/00003246-200211000-00016.CrossRefPubMed
20.
go back to reference Chemla D, Hebert JL, Coirault C, Zamani K, Suard I, Colin P, Lecarpentier Y: Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans. Am J Physiol. 1998, 274: H500-H505.PubMed Chemla D, Hebert JL, Coirault C, Zamani K, Suard I, Colin P, Lecarpentier Y: Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans. Am J Physiol. 1998, 274: H500-H505.PubMed
21.
go back to reference Pinsky MR: Heart lung interactions during mechanical ventilation. Curr Opin Crit Care. 2012, 18: 256-260. 10.1097/MCC.0b013e3283532b73.CrossRefPubMed Pinsky MR: Heart lung interactions during mechanical ventilation. Curr Opin Crit Care. 2012, 18: 256-260. 10.1097/MCC.0b013e3283532b73.CrossRefPubMed
23.
go back to reference Critchley LA, Yang XX, Lee A: Assessment of trending ability of cardiac output monitors by polar plot methodology. J Cardioth Vasc Anesth. 2011, 25: 536-546. 10.1053/j.jvca.2011.01.003.CrossRef Critchley LA, Yang XX, Lee A: Assessment of trending ability of cardiac output monitors by polar plot methodology. J Cardioth Vasc Anesth. 2011, 25: 536-546. 10.1053/j.jvca.2011.01.003.CrossRef
24.
go back to reference Critchley LA, Critchley JA: A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010, 111: 1180-1192. 10.1213/ANE.0b013e3181f08a5b.CrossRefPubMed Critchley LA, Critchley JA: A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010, 111: 1180-1192. 10.1213/ANE.0b013e3181f08a5b.CrossRefPubMed
25.
go back to reference Monnet X, Anguel N, Naudin B, Jabot J, Richard C, Teboul JL: Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices. Crit Care. 2010, 14: R109-10.1186/cc9058.CrossRefPubMedPubMedCentral Monnet X, Anguel N, Naudin B, Jabot J, Richard C, Teboul JL: Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices. Crit Care. 2010, 14: R109-10.1186/cc9058.CrossRefPubMedPubMedCentral
26.
go back to reference Meng L, Phuong Tran N, Alexander BS, Laning K, Chen G, Kain ZN, Cannesson M: The impact of phenylephrine, ephedrine, and increased preload on third-generation Vigileo-FloTrac and esophageal doppler cardiac output measurements. Anesth Analg. 2011, 113: 751-757.CrossRefPubMed Meng L, Phuong Tran N, Alexander BS, Laning K, Chen G, Kain ZN, Cannesson M: The impact of phenylephrine, ephedrine, and increased preload on third-generation Vigileo-FloTrac and esophageal doppler cardiac output measurements. Anesth Analg. 2011, 113: 751-757.CrossRefPubMed
27.
go back to reference Critchley LA, Peng ZY, Fok BS, Lee A, Phillips RA: Testing the reliability of a new ultrasonic cardiac output monitor, the USCOM, by using aortic flowprobes in anesthetized dogs. Anesth Analg. 2005, 100: 748-753. 10.1213/01.ANE.0000144774.42408.05.CrossRefPubMed Critchley LA, Peng ZY, Fok BS, Lee A, Phillips RA: Testing the reliability of a new ultrasonic cardiac output monitor, the USCOM, by using aortic flowprobes in anesthetized dogs. Anesth Analg. 2005, 100: 748-753. 10.1213/01.ANE.0000144774.42408.05.CrossRefPubMed
28.
go back to reference Bia D, Barra JG, Grignola JC, Gines FF, Armentano RL: Pulmonary artery smooth muscle activation attenuates arterial dysfunction during acute pulmonary hypertension. J Appl Physiol. 2005, 98: 605-613. Bia D, Barra JG, Grignola JC, Gines FF, Armentano RL: Pulmonary artery smooth muscle activation attenuates arterial dysfunction during acute pulmonary hypertension. J Appl Physiol. 2005, 98: 605-613.
29.
go back to reference Thiele RH, Nemergut EC, Lynch C: The physiologic implications of isolated alfa1 adrenergic stimulation. Anesth Analg. 2011, 113: 284-296. 10.1213/ANE.0b013e3182124c0e.CrossRefPubMed Thiele RH, Nemergut EC, Lynch C: The physiologic implications of isolated alfa1 adrenergic stimulation. Anesth Analg. 2011, 113: 284-296. 10.1213/ANE.0b013e3182124c0e.CrossRefPubMed
30.
go back to reference Magder S: Phenylephrine and tangible bias. Anesth Analg. 2011, 113: 211-213. 10.1213/ANE.0b013e318220406a.CrossRefPubMed Magder S: Phenylephrine and tangible bias. Anesth Analg. 2011, 113: 211-213. 10.1213/ANE.0b013e318220406a.CrossRefPubMed
32.
go back to reference Cannesson M, Jian Z, Chen G, Vu TQ, Hatib F: Effects of phenylephrine on cardiac output and venous return depend on the position of the heart on the Frank-Starling relationship. J Appl Physiol. 2012, 113: 281-289. 10.1152/japplphysiol.00126.2012.CrossRefPubMed Cannesson M, Jian Z, Chen G, Vu TQ, Hatib F: Effects of phenylephrine on cardiac output and venous return depend on the position of the heart on the Frank-Starling relationship. J Appl Physiol. 2012, 113: 281-289. 10.1152/japplphysiol.00126.2012.CrossRefPubMed
33.
go back to reference Monnet X, Guerin L, Jozwiak M, Bataille A, Julien F, Richard C, Teboul JL: Pleth variability index is a weak predictor of fluid responsiveness in patients receiving norepinephrine. Br J Anesth. 2013, 110: 207-213. 10.1093/bja/aes373.CrossRef Monnet X, Guerin L, Jozwiak M, Bataille A, Julien F, Richard C, Teboul JL: Pleth variability index is a weak predictor of fluid responsiveness in patients receiving norepinephrine. Br J Anesth. 2013, 110: 207-213. 10.1093/bja/aes373.CrossRef
34.
go back to reference Monnet X, Letierce A, Hamzaoui O, Chemla D, Anguel N, Osman D, Richard C, Teboul JL: Arterial pressure allows monitoring the changes in cardiac output induced by volume expansion but not by norepinephrine. Crit Care Med. 2011, 39: 1394-1399. 10.1097/CCM.0b013e31820edcf0.CrossRefPubMed Monnet X, Letierce A, Hamzaoui O, Chemla D, Anguel N, Osman D, Richard C, Teboul JL: Arterial pressure allows monitoring the changes in cardiac output induced by volume expansion but not by norepinephrine. Crit Care Med. 2011, 39: 1394-1399. 10.1097/CCM.0b013e31820edcf0.CrossRefPubMed
35.
go back to reference Natalini G, Rosano A, Rocco Militano C, Di Maio A, Ferretti P, Bertelli M, de Giuli F, Bernardini A: Prediction of arterial pressure increase after fluid challenge. BMC Anesthesiology. 2012, 12: 3-10.1186/1471-2253-12-3.CrossRefPubMedPubMedCentral Natalini G, Rosano A, Rocco Militano C, Di Maio A, Ferretti P, Bertelli M, de Giuli F, Bernardini A: Prediction of arterial pressure increase after fluid challenge. BMC Anesthesiology. 2012, 12: 3-10.1186/1471-2253-12-3.CrossRefPubMedPubMedCentral
36.
go back to reference Lamia B, Chemla D, Richard C, Teboul JL: Clinical review: interpretation of arterial pressure wave in shock states. Crit Care. 2005, 9: 601-606. 10.1186/cc3891.CrossRefPubMedPubMedCentral Lamia B, Chemla D, Richard C, Teboul JL: Clinical review: interpretation of arterial pressure wave in shock states. Crit Care. 2005, 9: 601-606. 10.1186/cc3891.CrossRefPubMedPubMedCentral
37.
go back to reference Westerhof N, Stergiopulos N, Noble MIM: Snapshots of hemodynamics. 2010, New York: Springer, 2CrossRef Westerhof N, Stergiopulos N, Noble MIM: Snapshots of hemodynamics. 2010, New York: Springer, 2CrossRef
Metadata
Title
The increase of vasomotor tone avoids the ability of the dynamic preload indicators to estimate fluid responsiveness
Authors
Juan P Bouchacourt
Juan A Riva
Juan C Grignola
Publication date
01-12-2013
Publisher
BioMed Central
Published in
BMC Anesthesiology / Issue 1/2013
Electronic ISSN: 1471-2253
DOI
https://doi.org/10.1186/1471-2253-13-41

Other articles of this Issue 1/2013

BMC Anesthesiology 1/2013 Go to the issue