Skip to main content
Top
Published in: Critical Care 5/2012

01-10-2012 | Review

Bench-to-bedside review: An approach to hemodynamic monitoring - Guyton at the bedside

Author: Sheldon Magder

Published in: Critical Care | Issue 5/2012

Login to get access

Abstract

Hemodynamic monitoring is used to identify deviations from hemodynamic goals and to assess responses to therapy. To accomplish these goals one must understand how the circulation is regulated. In this review I begin with an historical review of the work of Arthur Guyton and his conceptual understanding of the circulation and then present an approach by which Guyton's concepts can be applied at the bedside. Guyton argued that cardiac output and central venous pressure are determined by the interaction of two functions: cardiac function, which is determined by cardiac performance; and a return function, which is determined by the return of blood to the heart. This means that changes in cardiac output are dependent upon changes of one of these two functions or of both. I start with an approach based on the approximation that blood pressure is determined by the product of cardiac output and systemic vascular resistance and that cardiac output is determined by cardiac function and venous return. A fall in blood pressure with no change in or a rise in cardiac output indicates that a decrease in vascular resistance is the dominant factor. If the fall in blood pressure is due to a fall in cardiac output then the role of a change in the return function and cardiac function can be separated by the patterns of changes in central venous pressure and cardiac output. Measurement of cardiac output is a central component to this approach but until recently it was not easy to obtain and was estimated from surrogates. However, there are now a number of non-invasive devices that can give measures of cardiac output and permit the use of physiological principles to more rapidly appreciate the primary pathophysiology behind hemodynamic abnormalities and to provide directed therapy.
Appendix
Available only for authorised users
Literature
1.
go back to reference Rushmer RF, Smith OA: Cardiac control. Physiol Rev. 1959, 39: 41-68.PubMed Rushmer RF, Smith OA: Cardiac control. Physiol Rev. 1959, 39: 41-68.PubMed
2.
go back to reference Guyton AC: Determination of cardiac output by equating venous return curves with cardiac response curves. Physiol Rev. 1955, 35: 123-129.PubMed Guyton AC: Determination of cardiac output by equating venous return curves with cardiac response curves. Physiol Rev. 1955, 35: 123-129.PubMed
3.
go back to reference Guyton AC, Lindsey AW, Bernathy B, Richardson T: Venous return at various right atrial pressures and the normal venous return curve. Am J Physiol. 1957, 189: 609-615.PubMed Guyton AC, Lindsey AW, Bernathy B, Richardson T: Venous return at various right atrial pressures and the normal venous return curve. Am J Physiol. 1957, 189: 609-615.PubMed
4.
go back to reference Guyton AC, Polizo D, Armstrong GG: Mean circulatory filling pressure measured immediately after cessation of heart pumping. Am J Physiol. 1954, 179: 261-267.PubMed Guyton AC, Polizo D, Armstrong GG: Mean circulatory filling pressure measured immediately after cessation of heart pumping. Am J Physiol. 1954, 179: 261-267.PubMed
5.
go back to reference Coleman TG, Manning RD, Norman RA, Guyton AC: Control of cardiac output by regional blood flow distribution. Ann Biomed Eng. 1974, 2: 149-163. 10.1007/BF02368487.CrossRef Coleman TG, Manning RD, Norman RA, Guyton AC: Control of cardiac output by regional blood flow distribution. Ann Biomed Eng. 1974, 2: 149-163. 10.1007/BF02368487.CrossRef
6.
go back to reference Magder S: The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct. J Appl Physiol. 2006, 101: 1523-1525. 10.1152/japplphysiol.00698.2006.CrossRefPubMed Magder S: The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct. J Appl Physiol. 2006, 101: 1523-1525. 10.1152/japplphysiol.00698.2006.CrossRefPubMed
7.
go back to reference Magder S, De Varennes B: Clinical death and the measurement of stressed vascular volume. Crit Care Med. 1998, 26: 1061-1104. 10.1097/00003246-199806000-00028.CrossRefPubMed Magder S, De Varennes B: Clinical death and the measurement of stressed vascular volume. Crit Care Med. 1998, 26: 1061-1104. 10.1097/00003246-199806000-00028.CrossRefPubMed
8.
go back to reference Rothe CF: Reflex control of veins and vascular capacitance. Physiol Rev. 1983, 63: 1281-1295.PubMed Rothe CF: Reflex control of veins and vascular capacitance. Physiol Rev. 1983, 63: 1281-1295.PubMed
9.
go back to reference Deschamps A, Magder S: Baroreflex control of regional capacitance and blood flow distribution with or without alpha adrenergic blockade. J Appl Physiol. 1992, 263: H1755-H1763. Deschamps A, Magder S: Baroreflex control of regional capacitance and blood flow distribution with or without alpha adrenergic blockade. J Appl Physiol. 1992, 263: H1755-H1763.
10.
go back to reference Magder S, Veerassamy S, Bates JH: A further analysis of why pulmonary venous pressure rises after the onset of LV dysfunction. J Appl Physiol. 2009, 106: 81-90.CrossRefPubMed Magder S, Veerassamy S, Bates JH: A further analysis of why pulmonary venous pressure rises after the onset of LV dysfunction. J Appl Physiol. 2009, 106: 81-90.CrossRefPubMed
11.
go back to reference Thiele RH, Nemergut EC, Lynch C: The physiologic implications of isolated alpha(1) adrenergic stimulation. Anesth Anal. 2011, 113: 284-296. 10.1213/ANE.0b013e3182124c0e.CrossRef Thiele RH, Nemergut EC, Lynch C: The physiologic implications of isolated alpha(1) adrenergic stimulation. Anesth Anal. 2011, 113: 284-296. 10.1213/ANE.0b013e3182124c0e.CrossRef
12.
go back to reference Thiele RH, Nemergut EC, Lynch C: The clinical implications of isolated α1 adrenergic stimulation. Anesth Analg. 2011, 113: 297-304. 10.1213/ANE.0b013e3182120ca5.CrossRefPubMed Thiele RH, Nemergut EC, Lynch C: The clinical implications of isolated α1 adrenergic stimulation. Anesth Analg. 2011, 113: 297-304. 10.1213/ANE.0b013e3182120ca5.CrossRefPubMed
13.
go back to reference Magder S: Phenylephrine and tangible bias. Anesth Analg. 2011, 113: 211-213. 10.1213/ANE.0b013e318220406a.CrossRefPubMed Magder S: Phenylephrine and tangible bias. Anesth Analg. 2011, 113: 211-213. 10.1213/ANE.0b013e318220406a.CrossRefPubMed
14.
go back to reference Brengelmann GL: Counterpoint: the classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is not correct. J Appl Physiol. 2006, 101: 1525-1526. 10.1152/japplphysiol.00698a.2006.CrossRefPubMed Brengelmann GL: Counterpoint: the classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is not correct. J Appl Physiol. 2006, 101: 1525-1526. 10.1152/japplphysiol.00698a.2006.CrossRefPubMed
15.
go back to reference Brengelmann GL: A critical analysis of the view that right atrial pressure determines venous return. J Appl Physiol. 2003, 94: 849-859.CrossRefPubMed Brengelmann GL: A critical analysis of the view that right atrial pressure determines venous return. J Appl Physiol. 2003, 94: 849-859.CrossRefPubMed
16.
go back to reference Burkhoff D, Tyberg JV: Why does pulmonary venous pressure rise after onset of left ventricular dysfunction: a theoretical analysis. Am J Physiol. 1993, 265: H1819-H1828.PubMed Burkhoff D, Tyberg JV: Why does pulmonary venous pressure rise after onset of left ventricular dysfunction: a theoretical analysis. Am J Physiol. 1993, 265: H1819-H1828.PubMed
17.
go back to reference Lindsey AW, Guyton AC: Continuous recording of pulmonary blood volume: pulmonary pressure and volume changes. Am J Physiol. 1959, 197: 959-962.PubMed Lindsey AW, Guyton AC: Continuous recording of pulmonary blood volume: pulmonary pressure and volume changes. Am J Physiol. 1959, 197: 959-962.PubMed
18.
go back to reference Pouleur H, Covell JW, Ross J: Effects of nitroprusside on venous return and central blood volume in the absence and presence of acute heart failure. Circulation. 1980, 61: 328-337. 10.1161/01.CIR.61.2.328.CrossRefPubMed Pouleur H, Covell JW, Ross J: Effects of nitroprusside on venous return and central blood volume in the absence and presence of acute heart failure. Circulation. 1980, 61: 328-337. 10.1161/01.CIR.61.2.328.CrossRefPubMed
19.
go back to reference Ogilvie RI: Effect of nitroglycerin on peripheral blood flow distribution and venous return. J Pharmacol Exp Ther. 1978, 207: 372-380.PubMed Ogilvie RI: Effect of nitroglycerin on peripheral blood flow distribution and venous return. J Pharmacol Exp Ther. 1978, 207: 372-380.PubMed
20.
go back to reference Green JF: Mechanism of action of isoproterenol on venous return. Am J Physiol. 1977, 232: H152-H156.PubMed Green JF: Mechanism of action of isoproterenol on venous return. Am J Physiol. 1977, 232: H152-H156.PubMed
21.
go back to reference Permutt S, Riley S: Hemodynamics of collapsible vessels with tone: the vascular waterfall. J Appl Physiol. 1963, 18: 924-932.PubMed Permutt S, Riley S: Hemodynamics of collapsible vessels with tone: the vascular waterfall. J Appl Physiol. 1963, 18: 924-932.PubMed
22.
go back to reference Magder S, Bafaqeeh F: The clinical role of central venous pressure measurements. J Intensive Care Med. 2007, 22: 44-51. 10.1177/0885066606295303.CrossRefPubMed Magder S, Bafaqeeh F: The clinical role of central venous pressure measurements. J Intensive Care Med. 2007, 22: 44-51. 10.1177/0885066606295303.CrossRefPubMed
23.
go back to reference Magder S, Potter BJ, Varennes BD, Doucette S, Fergusson D: Fluids after cardiac surgery: a pilot study of the use of colloids versus crystalloids. Crit Care Med. 2010, 38: 2117-2124. 10.1097/CCM.0b013e3181f3e08c.CrossRefPubMed Magder S, Potter BJ, Varennes BD, Doucette S, Fergusson D: Fluids after cardiac surgery: a pilot study of the use of colloids versus crystalloids. Crit Care Med. 2010, 38: 2117-2124. 10.1097/CCM.0b013e3181f3e08c.CrossRefPubMed
24.
go back to reference de Waal EE, Wappler F, Buhre WF: Cardiac output monitoring. Curr Opin Anaesthesiol. 2009, 22: 71-77. 10.1097/ACO.0b013e32831f44d0.CrossRefPubMed de Waal EE, Wappler F, Buhre WF: Cardiac output monitoring. Curr Opin Anaesthesiol. 2009, 22: 71-77. 10.1097/ACO.0b013e32831f44d0.CrossRefPubMed
25.
go back to reference Vincent JL, Rhodes A, Perel A, Martin GS, Della Rocca G, Vallet B, Pinsky MR, Hofer CK, Teboul JL, de Boode WP, Scolletta S, Vieillard-Baron A, De Backer D, Walley KR, Maggiorini M, Singer M: Clinical review: Update on hemodynamic monitoring - a consensus of 16. Crit Care. 2011, 15: 229-10.1186/cc10291.PubMedCentralCrossRefPubMed Vincent JL, Rhodes A, Perel A, Martin GS, Della Rocca G, Vallet B, Pinsky MR, Hofer CK, Teboul JL, de Boode WP, Scolletta S, Vieillard-Baron A, De Backer D, Walley KR, Maggiorini M, Singer M: Clinical review: Update on hemodynamic monitoring - a consensus of 16. Crit Care. 2011, 15: 229-10.1186/cc10291.PubMedCentralCrossRefPubMed
26.
go back to reference Magder SA, Georgiadis G, Cheong T: Respiratory variations in right atrial pressure predict response to fluid challenge. J Crit Care. 1992, 7: 76-85. 10.1016/0883-9441(92)90032-3.CrossRef Magder SA, Georgiadis G, Cheong T: Respiratory variations in right atrial pressure predict response to fluid challenge. J Crit Care. 1992, 7: 76-85. 10.1016/0883-9441(92)90032-3.CrossRef
27.
go back to reference Magder S: Central venous pressure: a useful but not so simple measurement. Crit Care Med. 2006, 34: 2224-2227. 10.1097/01.CCM.0000227646.98423.98.CrossRefPubMed Magder S: Central venous pressure: a useful but not so simple measurement. Crit Care Med. 2006, 34: 2224-2227. 10.1097/01.CCM.0000227646.98423.98.CrossRefPubMed
28.
go back to reference Magder S, Lagonidis D, Erice F: The use of respiratory variations in right atrial pressure to predict the cardiac output response to PEEP. J Crit Care. 2001, 16: 108-114. 10.1053/jcrc.2001.28194.CrossRefPubMed Magder S, Lagonidis D, Erice F: The use of respiratory variations in right atrial pressure to predict the cardiac output response to PEEP. J Crit Care. 2001, 16: 108-114. 10.1053/jcrc.2001.28194.CrossRefPubMed
29.
go back to reference Nanas S, Magder S: Adaptations of the peripheral circulation to PEEP. Am Rev Respir Dis. 1992, 146: 688-693.CrossRefPubMed Nanas S, Magder S: Adaptations of the peripheral circulation to PEEP. Am Rev Respir Dis. 1992, 146: 688-693.CrossRefPubMed
30.
go back to reference Fessler HE, Brower RG, Wise RA, Permutt S: Effects of positive end-expiratory pressure on the gradient for venous return. Am Rev Respir Dis. 1992, 146: 4-10.CrossRefPubMed Fessler HE, Brower RG, Wise RA, Permutt S: Effects of positive end-expiratory pressure on the gradient for venous return. Am Rev Respir Dis. 1992, 146: 4-10.CrossRefPubMed
Metadata
Title
Bench-to-bedside review: An approach to hemodynamic monitoring - Guyton at the bedside
Author
Sheldon Magder
Publication date
01-10-2012
Publisher
BioMed Central
Published in
Critical Care / Issue 5/2012
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc11395

Other articles of this Issue 5/2012

Critical Care 5/2012 Go to the issue