Skip to main content
Top
Published in: The Journal of Obstetrics and Gynecology of India 1/2020

01-02-2020 | Ultrasound | Original Article

Down’s Syndrome Screening in the First Trimester with Additional Serum Markers: Indian Parameters

Published in: The Journal of Obstetrics and Gynecology of India | Issue 1/2020

Login to get access

Abstract

Objective

To derive a risk calculation algorithm suitable for use in India when screening for Down’s syndrome using four first-trimester maternal serum markers either alone or with ultrasound nuchal translucency (NT).

Methods

Stored maternal serum samples (− 20 °C) from 411 singleton unaffected pregnancies were retrieved and measured for pregnancy-associated plasma protein (PAPP-A), free β-human chorionic gonadotropin (hCG), placental growth factor and α-fetoprotein. Samples were taken at 10–13 weeks’ gestation. Equations were derived to express marker levels in multiples of the gestation-specific normal median, adjusted for maternal weight. Gaussian model parameters were derived and compared with six published non-Indian studies; NT parameters were derived from 27,647 women screened in India. On the basis of the maternal age distribution in 64,473 Indian women screened in 2016–2017, the model was used to predict test performance.

Results

The model predicted a detection rate for a serum-only protocol of 80% for a 5% false-positive rate. Using a 1 in 250 at term Down’s syndrome risk cut-off, the predicted detection rate was 78% and the false-positive rate was 4.1%. When NT was also included, the rates were 95% for 5% and 90% for 1.4%, respectively.

Conclusion

First-trimester screening using four serum markers only can be carried out in India. Performance is expected to be similar to the second-trimester Quad test and will also facilitate early screening for preeclampsia and open spina bifida. A protocol of NT plus the four serum markers enhances the performance compared with NT, PAPP-A and free β-hCG.
Literature
1.
go back to reference Cuckle HS, Pergament E, Benn P. Multianalyte maternal serum screening for chromosomal abnormalities and neural tube defects. In: Milunsky A, Milunsky JM, editors. Genetic disorders and the fetus: diagnosis, prevention and treatment. 7th ed. Hoboken: Wiley-Blackwell; 2015. Cuckle HS, Pergament E, Benn P. Multianalyte maternal serum screening for chromosomal abnormalities and neural tube defects. In: Milunsky A, Milunsky JM, editors. Genetic disorders and the fetus: diagnosis, prevention and treatment. 7th ed. Hoboken: Wiley-Blackwell; 2015.
2.
go back to reference Donalson K, Turner S, Morrison L, et al. Maternal serum placental growth factor and α-fetoprotein testing in first trimester screening for Down’s syndrome. Prenat Diagn. 2013;33:1–5.CrossRef Donalson K, Turner S, Morrison L, et al. Maternal serum placental growth factor and α-fetoprotein testing in first trimester screening for Down’s syndrome. Prenat Diagn. 2013;33:1–5.CrossRef
3.
go back to reference Johnson J, Pastuck M, Metcalf A, et al. New approaches to first trimester Down’s syndrome screening using additional serum markers and cell free DNA. Prenat Diagn. 2013;33:1044–9.CrossRef Johnson J, Pastuck M, Metcalf A, et al. New approaches to first trimester Down’s syndrome screening using additional serum markers and cell free DNA. Prenat Diagn. 2013;33:1044–9.CrossRef
4.
go back to reference Huang T, Dennis A, Meschino WS, et al. First trimester screening for Down syndrome using nuchal translucency, maternal serum pregnancy-associated plasma protein A, free-β human chorionic gonadotrophin, placental growth factor and α-fetoprotein. Prenat Diagn. 2015;35(7):709–16.CrossRef Huang T, Dennis A, Meschino WS, et al. First trimester screening for Down syndrome using nuchal translucency, maternal serum pregnancy-associated plasma protein A, free-β human chorionic gonadotrophin, placental growth factor and α-fetoprotein. Prenat Diagn. 2015;35(7):709–16.CrossRef
5.
go back to reference O’Gorman N, Wright D, Poon LC, et al. Accuracy of competing-risks model in screening for pre-eclampsia by maternal factors and biomarkers at 11–13 weeks’ gestation. Ultrasound Obstet Gynecol. 2017;49(6):751–5.CrossRef O’Gorman N, Wright D, Poon LC, et al. Accuracy of competing-risks model in screening for pre-eclampsia by maternal factors and biomarkers at 11–13 weeks’ gestation. Ultrasound Obstet Gynecol. 2017;49(6):751–5.CrossRef
6.
go back to reference Bernard J-P, Cuckle HS, Bernard M, et al. Combined screening for open spina bifida at 11–14 weeks using fetal biparietal diameter and maternal serum markers. Am J Obstet Gynecol. 2013;209(3):223.e1–5.CrossRef Bernard J-P, Cuckle HS, Bernard M, et al. Combined screening for open spina bifida at 11–14 weeks using fetal biparietal diameter and maternal serum markers. Am J Obstet Gynecol. 2013;209(3):223.e1–5.CrossRef
7.
go back to reference Wright D, Syngelaki A, Bradbury I, et al. First-trimester screening for trisomies 21, 18 and 13 by ultrasound and biochemical testing. Fetal Diagn Ther. 2014;35(2):118–26.CrossRef Wright D, Syngelaki A, Bradbury I, et al. First-trimester screening for trisomies 21, 18 and 13 by ultrasound and biochemical testing. Fetal Diagn Ther. 2014;35(2):118–26.CrossRef
8.
go back to reference Palomaki GE, Eklund EE, Neveux LM, et al. Evaluating first trimester maternal serum screening combinations for Down syndrome suitable for use with reflexive secondary screening via sequencing of cell free DNA: high detection with low rates of invasive procedures. Prenat Diagn. 2015;35(8):789–96.CrossRef Palomaki GE, Eklund EE, Neveux LM, et al. Evaluating first trimester maternal serum screening combinations for Down syndrome suitable for use with reflexive secondary screening via sequencing of cell free DNA: high detection with low rates of invasive procedures. Prenat Diagn. 2015;35(8):789–96.CrossRef
9.
go back to reference Carmichael JB, Liu HP, Janik D, et al. Expanded conventional first trimester screening. Prenat Diagn. 2017;37(8):802–7.CrossRef Carmichael JB, Liu HP, Janik D, et al. Expanded conventional first trimester screening. Prenat Diagn. 2017;37(8):802–7.CrossRef
Metadata
Title
Down’s Syndrome Screening in the First Trimester with Additional Serum Markers: Indian Parameters
Publication date
01-02-2020
Published in
The Journal of Obstetrics and Gynecology of India / Issue 1/2020
Print ISSN: 0971-9202
Electronic ISSN: 0975-6434
DOI
https://doi.org/10.1007/s13224-018-1198-1

Other articles of this Issue 1/2020

The Journal of Obstetrics and Gynecology of India 1/2020 Go to the issue