Skip to main content
Top
Published in: Canadian Journal of Anesthesia/Journal canadien d'anesthésie 7/2019

01-07-2019 | Computed Tomography | Reports of Original Investigations

Right upper lobe anatomy revisited: a computed tomography scan study

Authors: Jean S. Bussières, MD, FRCPC, Michel Gingras, MD, FRCPC, Lindsay Perron, MD, Jacques Somma, MD, BEng, FRCPC, Marili Frenette, MD, Etienne J. Couture, MD, FRCPC, Olivier Moreault, MD, Yves Lacasse, MD, MSc, FRCPC

Published in: Canadian Journal of Anesthesia/Journal canadien d'anesthésie | Issue 7/2019

Login to get access

Abstract

Background

The double lumen tube (DLT) has become the most popular way to isolate the lungs for thoracic surgery. The variable anatomy of the right main stem bronchus (RMSB) seems to be the main reason clinicians are unwilling to use the right-sided DLT (R-DLT). The factors that could compromise the adequate ventilation of the right lung are mostly the variable length of the RMSB and the misalignment of the lateral orifice of the R-DLT in regard to the right upper lobe bronchus (RULB). The objectives of this study were to validate an alternative method to estimate the RMSB length, and to determine the distribution of the angulation of the ostium of the RULB.

Methods

From high-resolution computed tomography scans of the thorax of 106 consecutive patients, the length of the RMSB was measured using Kim’s method and the carina-to-carina method. The angle between the RULB origin and the lateral aspect of the RMSB was also measured. All these measurements were correlated and inter-observer variation documented.

Results

From the Kim’s method, the mean (standard deviation [SD]) length of the RMSB was 25.5 (4.7) mm. From the alternative carina-to-carina method, the mean (SD) length of RMSB was 29.4 (4.6) mm. The inter-observer agreement was substantial with both methods (Kim’s method: intraclass correlation coefficient [ICC] = 0.84; carina-to-carina method: ICC = 0.95). Both measures were closely related (ICC = 0.93; P < 0.001). The RULB presented a wide range angulation [mean (SD), 0.1 (9.5)°; range, −28.6 to 21.2].

Conclusion

These anatomic observations provide a better understanding of the variable anatomy of the right bronchial tree and may guide thoracic anesthesiologists in the choice of the best lung isolation device for their patients.
Literature
1.
go back to reference Benumof JL, Partridge BL, Salvatierra C, Keating J. Margin of safety in positioning modern double-lumen endotracheal tubes. Anesthesiology 1987; 67: 729-38.CrossRefPubMed Benumof JL, Partridge BL, Salvatierra C, Keating J. Margin of safety in positioning modern double-lumen endotracheal tubes. Anesthesiology 1987; 67: 729-38.CrossRefPubMed
3.
go back to reference Pedoto A. How to choose the double-lumen tube size and side: the eternal debate. Anesthesiol Clin 2012; 30: 671-81.CrossRefPubMed Pedoto A. How to choose the double-lumen tube size and side: the eternal debate. Anesthesiol Clin 2012; 30: 671-81.CrossRefPubMed
4.
go back to reference Kim JH, Park SH, Han SH, Nahm FS, Jung CK, Kim KM. The distance between the carina and the distal margin of the right upper lobe orifice measured by computerised tomography as a guide to right-sided double-lumen endobronchial tube use. Anaesthesia 2013; 68: 700-5.CrossRefPubMed Kim JH, Park SH, Han SH, Nahm FS, Jung CK, Kim KM. The distance between the carina and the distal margin of the right upper lobe orifice measured by computerised tomography as a guide to right-sided double-lumen endobronchial tube use. Anaesthesia 2013; 68: 700-5.CrossRefPubMed
5.
go back to reference Bussieres JS, Lacasse Y, Cote D, et al. Modified right-sided Broncho-Cath double lumen tube improves endobronchial positioning: a randomized study. Can J Anesth 2007; 54: 276-82.CrossRefPubMed Bussieres JS, Lacasse Y, Cote D, et al. Modified right-sided Broncho-Cath double lumen tube improves endobronchial positioning: a randomized study. Can J Anesth 2007; 54: 276-82.CrossRefPubMed
6.
go back to reference Jit H, Jit I. Dimensions & shape of the trachea in the neonates, children & adults in northwest India. Indian J Med Res 2000; 112: 27-33.PubMed Jit H, Jit I. Dimensions & shape of the trachea in the neonates, children & adults in northwest India. Indian J Med Res 2000; 112: 27-33.PubMed
Metadata
Title
Right upper lobe anatomy revisited: a computed tomography scan study
Authors
Jean S. Bussières, MD, FRCPC
Michel Gingras, MD, FRCPC
Lindsay Perron, MD
Jacques Somma, MD, BEng, FRCPC
Marili Frenette, MD
Etienne J. Couture, MD, FRCPC
Olivier Moreault, MD
Yves Lacasse, MD, MSc, FRCPC
Publication date
01-07-2019
Publisher
Springer International Publishing
Published in
Canadian Journal of Anesthesia/Journal canadien d'anesthésie / Issue 7/2019
Print ISSN: 0832-610X
Electronic ISSN: 1496-8975
DOI
https://doi.org/10.1007/s12630-019-01342-7

Other articles of this Issue 7/2019

Canadian Journal of Anesthesia/Journal canadien d'anesthésie 7/2019 Go to the issue