Skip to main content
Top
Published in: Canadian Journal of Anesthesia/Journal canadien d'anesthésie 11/2017

01-11-2017 | Reports of Original Investigations

Agreement between venous and arterial blood gas analysis of acid-base status in critical care and ward patients: a retrospective cohort study

Authors: Claudio M. Martin, MSc, MD, FRCPC, CCPE, Fran Priestap, MSc

Published in: Canadian Journal of Anesthesia/Journal canadien d'anesthésie | Issue 11/2017

Login to get access

Abstract

Purpose

To determine whether the use of venous blood gases can be a suitable alternative to arterial sampling to evaluate acid-base status.

Methods

The database of the clinical laboratory in a large academic hospital was searched for records of venous blood gas analysis and an arterial sample taken within ten minutes from the same patient. Bland-Altman analyses of pH, pCO2, and lactate were performed for samples obtained from patients separately from within and outside the intensive care unit (ICU).

Results

In 2,296 paired arterial-venous samples from 351 ICU patients, the bias was 0.044, −6.2 mmHg, and −0.07 mEq·L−1 for pH, pCO2, and lactate, respectively. The range of agreement centred on this bias (upper minus lower level of agreement) was 0.134, 16.7 mmHg, and 1.35 mEq·L−1 for pH, pCO2, and lactate, respectively. Intraclass correlation coefficients (ICCs) were 0.79, 0.76, and 0.99 for pH, pCO2, and lactate, respectively, indicating excellent agreement. Multiple samples obtained from the same patient had a median standard deviation of 0.02, 2.77 mmHg, and 0.18 mEq·L−1 for pH, pCO2, and lactate, respectively. Similar agreement was observed in samples from patients outside the ICU, although the ICC was only 0.53 for pCO2.

Conclusions

Venous gases are suitable for initial evaluation of acid-base status in critically ill patients. Based on clinical evaluation, an arterial sample may then be considered for confirmation, and thereafter, venous blood gases could be sufficient for monitoring response to treatment.
Literature
1.
go back to reference Davis MD, Walsh BK, Sittig SE, Restrepo RD. AARC clinical practice guideline: blood gas analysis and hemoximetry: 2013. Respir Care 2013; 58: 1694-703.CrossRefPubMed Davis MD, Walsh BK, Sittig SE, Restrepo RD. AARC clinical practice guideline: blood gas analysis and hemoximetry: 2013. Respir Care 2013; 58: 1694-703.CrossRefPubMed
2.
go back to reference Dev SP, Hillmer MD, Ferri M. Videos in clinical medicine: arterial puncture for blood gas analysis. N Engl J Med 2011; 364: e7.CrossRefPubMed Dev SP, Hillmer MD, Ferri M. Videos in clinical medicine: arterial puncture for blood gas analysis. N Engl J Med 2011; 364: e7.CrossRefPubMed
3.
go back to reference Zavorsky GS, Cao J, Mayo NE, Gabbay R, Murias JM. Arterial versus capillary blood gases a meta-analysis. Respir Physiol Neurobiol 2007; 155: 268-79.CrossRefPubMed Zavorsky GS, Cao J, Mayo NE, Gabbay R, Murias JM. Arterial versus capillary blood gases a meta-analysis. Respir Physiol Neurobiol 2007; 155: 268-79.CrossRefPubMed
4.
go back to reference Kelly AM. Review article: can venous blood gas analysis replace arterial in emergency medical care. Emerg Med Australas 2010; 22: 493-8.CrossRefPubMed Kelly AM. Review article: can venous blood gas analysis replace arterial in emergency medical care. Emerg Med Australas 2010; 22: 493-8.CrossRefPubMed
5.
go back to reference Lim BL, Kelly AM. A meta-analysis on the utility of peripheral venous blood gas analyses in exacerbations of chronic obstructive pulmonary disease in the emergency department. Eur J Emerg Med 2010; 17: 246-8.CrossRefPubMed Lim BL, Kelly AM. A meta-analysis on the utility of peripheral venous blood gas analyses in exacerbations of chronic obstructive pulmonary disease in the emergency department. Eur J Emerg Med 2010; 17: 246-8.CrossRefPubMed
6.
go back to reference Herrington WG, Nye HJ, Hammersley MS, Watkinson PJ. Are arterial and venous samples clinically equivalent for the estimation of pH, serum bicarbonate and potassium concentration in critically ill patients ? Diabet Med 2012; 29: 32-5.CrossRefPubMed Herrington WG, Nye HJ, Hammersley MS, Watkinson PJ. Are arterial and venous samples clinically equivalent for the estimation of pH, serum bicarbonate and potassium concentration in critically ill patients ? Diabet Med 2012; 29: 32-5.CrossRefPubMed
7.
go back to reference Hynes D, Bates S, Loughman A, Klim S, French C, Kelly AM. Arteriovenous blood gas agreement in intensive care patients with varying levels of circulatory compromise: a pilot study. Crit Care Resusc 2015; 17: 253-6.PubMed Hynes D, Bates S, Loughman A, Klim S, French C, Kelly AM. Arteriovenous blood gas agreement in intensive care patients with varying levels of circulatory compromise: a pilot study. Crit Care Resusc 2015; 17: 253-6.PubMed
8.
go back to reference Kelly AM, Kerr D, Middleton P. Validation of venous pCO2 to screen for arterial hypercarbia in patients with chronic obstructive airways disease. J Emerg Med 2005; 28: 377-9.CrossRefPubMed Kelly AM, Kerr D, Middleton P. Validation of venous pCO2 to screen for arterial hypercarbia in patients with chronic obstructive airways disease. J Emerg Med 2005; 28: 377-9.CrossRefPubMed
9.
go back to reference Treger R, Pirouz S, Kamangar N, Corry D. Agreement between central venous and arterial blood gas measurements in the intensive care unit. Clin J Am Soc Nephrol 2010; 5: 390-4.CrossRefPubMedPubMedCentral Treger R, Pirouz S, Kamangar N, Corry D. Agreement between central venous and arterial blood gas measurements in the intensive care unit. Clin J Am Soc Nephrol 2010; 5: 390-4.CrossRefPubMedPubMedCentral
10.
go back to reference Yıldizdas D, Yapicioglu H, Yilmaz HL, Sertdemir Y. Correlation of simultaneously obtained capillary, venous, and arterial blood gases of patients in a paediatric intensive care unit. Arch Dis Child 2004; 89: 176-80.CrossRefPubMedPubMedCentral Yıldizdas D, Yapicioglu H, Yilmaz HL, Sertdemir Y. Correlation of simultaneously obtained capillary, venous, and arterial blood gases of patients in a paediatric intensive care unit. Arch Dis Child 2004; 89: 176-80.CrossRefPubMedPubMedCentral
11.
12.
go back to reference Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 327: 307-10.CrossRef Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 327: 307-10.CrossRef
13.
go back to reference Zou GY. Confidence interval estimation for the Bland-Altman limits of agreement with multiple observations per individual. Stat Methods Med Res 2013; 22: 630-42.CrossRefPubMed Zou GY. Confidence interval estimation for the Bland-Altman limits of agreement with multiple observations per individual. Stat Methods Med Res 2013; 22: 630-42.CrossRefPubMed
14.
go back to reference Pilon CS, Leathley M, London R, et al. Practice guideline for arterial blood gas measurement in the intensive care unit decreases numbers and increases appropriateness of tests. Crit Care Med 1997; 25: 1308-13.CrossRefPubMed Pilon CS, Leathley M, London R, et al. Practice guideline for arterial blood gas measurement in the intensive care unit decreases numbers and increases appropriateness of tests. Crit Care Med 1997; 25: 1308-13.CrossRefPubMed
15.
go back to reference Giavarina D. Understanding Bland Altman analysis. Biochem Med (Zagreb) 2015; 25: 141-51.CrossRef Giavarina D. Understanding Bland Altman analysis. Biochem Med (Zagreb) 2015; 25: 141-51.CrossRef
Metadata
Title
Agreement between venous and arterial blood gas analysis of acid-base status in critical care and ward patients: a retrospective cohort study
Authors
Claudio M. Martin, MSc, MD, FRCPC, CCPE
Fran Priestap, MSc
Publication date
01-11-2017
Publisher
Springer US
Published in
Canadian Journal of Anesthesia/Journal canadien d'anesthésie / Issue 11/2017
Print ISSN: 0832-610X
Electronic ISSN: 1496-8975
DOI
https://doi.org/10.1007/s12630-017-0951-8

Other articles of this Issue 11/2017

Canadian Journal of Anesthesia/Journal canadien d'anesthésie 11/2017 Go to the issue