Skip to main content
Top
Published in: Canadian Journal of Anesthesia/Journal canadien d'anesthésie 9/2014

01-09-2014 | Reports of Original Investigations

Randomized prospective trial comparing two supraglottic airway devices: i-gel™ and LMA-Supreme™ in paralyzed patients

Authors: Nikola Joly, MD, Louis-Pierre Poulin, MD, Issam Tanoubi, MD, Pierre Drolet, MD, François Donati, MD, PhD, Patrick St-Pierre, MD

Published in: Canadian Journal of Anesthesia/Journal canadien d'anesthésie | Issue 9/2014

Login to get access

Abstract

Purpose

Many features can influence the choice of a supraglottic airway device (SAD), including ease of insertion, adequate ventilation pressures and lack of adverse effects. The goal of this randomized prospective trial was to compare the performance of the i-gel™ with that of the LMA-Supreme™.

Methods

One hundred adult patients (American Society of Anesthesiologists I-III) scheduled to undergo elective surgery under general anesthesia were randomized to either an i-gel (n = 50) or an LMA-Supreme (n = 50). The primary objective was to compare ventilation pressures. Secondary objectives included time and number of attempts needed to introduce the device, adverse effects, and repositioning. The endoscopic view of the glottic aperture and the position of the drain tubes in relation to the esophagus were also evaluated.

Results

The devices were inserted successfully in 46 (92%) patients in both groups. There was no significant difference in the [mean (SD)] leak pressure [i-gel: 23 (7) cm H2O vs LMA-Supreme: 21 (8) cm H2O; P = 0.14] or peak inspiratory pressure between both devices. Insertion time was shorter with the i-gel than with the LMA-Supreme [19 (7) sec vs 27 (17) sec, respectively; P = 0.003]. The vocal cords were completely visualized more often through the i-gel (70%) than through the LMA-Supreme (50%) (P = 0.007). Esophageal mucosa was easily visualized through the drain port in all but four patients, two patients in each group. There was no difference between groups regarding preoperative or postoperative complications. Postoperative patient discomfort was generally mild and comparable between both devices.

Conclusion

Both the LMA-Supreme and the i-gel offer similar performance for positive pressure ventilation in paralyzed patients during general anesthesia. The i-gel was associated with a slightly faster insertion time and better fibrescopic visualization of the glottis. This trial was registered at Clinicaltrials.gov: NCT01001078.
Footnotes
1
http://​www.​randomization.​com. Available from URL (accessed February 2014).
 
Literature
1.
go back to reference Theiler LG, Kleine-Brueggeney M, Kaiser D, et al. Crossover comparison of the Laryngeal Mask Supreme™ and the i-gel™ in simulated difficult airway scenario in anesthetized patients. Anesthesiology 2009; 111: 55-62.PubMedCrossRef Theiler LG, Kleine-Brueggeney M, Kaiser D, et al. Crossover comparison of the Laryngeal Mask Supreme™ and the i-gel™ in simulated difficult airway scenario in anesthetized patients. Anesthesiology 2009; 111: 55-62.PubMedCrossRef
2.
go back to reference Janakiraman C, Chethan DB, Wilkes AR, Stacey MR, Goodwin N. A randomised crossover trial comparing the i-gel supraglottic airway and classic laryngeal mask airway. Anaesthesia 2009; 64: 674-8.PubMedCrossRef Janakiraman C, Chethan DB, Wilkes AR, Stacey MR, Goodwin N. A randomised crossover trial comparing the i-gel supraglottic airway and classic laryngeal mask airway. Anaesthesia 2009; 64: 674-8.PubMedCrossRef
3.
go back to reference Weber U, Oguz R, Potura LA, Kimberger O, Kober A, Tschernko E. Comparison of the i-gel and the LMA-Unique laryngeal mask airway in patients with mild to moderate obesity during elective short-term surgery. Anaesthesia 2011; 66: 481-7.PubMedCrossRef Weber U, Oguz R, Potura LA, Kimberger O, Kober A, Tschernko E. Comparison of the i-gel and the LMA-Unique laryngeal mask airway in patients with mild to moderate obesity during elective short-term surgery. Anaesthesia 2011; 66: 481-7.PubMedCrossRef
4.
go back to reference Gatward JJ, Cook TM, Seller C, et al. Evaluation of the size 4 i-gel airway in one hundred non-paralysed patients. Anaesthesia 2008; 63: 1124-30.PubMedCrossRef Gatward JJ, Cook TM, Seller C, et al. Evaluation of the size 4 i-gel airway in one hundred non-paralysed patients. Anaesthesia 2008; 63: 1124-30.PubMedCrossRef
5.
go back to reference Richez B, Saltel L, Banchereau F, Torrielli R, Cros AM. A new single use supraglottic airway device with a noninflatable cuff and an esophageal vent: an observational study of the i-gel. Anesth Analg 2008; 106: 1137-9.PubMedCrossRef Richez B, Saltel L, Banchereau F, Torrielli R, Cros AM. A new single use supraglottic airway device with a noninflatable cuff and an esophageal vent: an observational study of the i-gel. Anesth Analg 2008; 106: 1137-9.PubMedCrossRef
6.
go back to reference Uppal V, Fletcher G, Kinsella J. Comparison of the i-gel with the cuffed tracheal tube during pressure-controlled ventilation. Br J Anaesth 2009; 102: 264-8.PubMedCrossRef Uppal V, Fletcher G, Kinsella J. Comparison of the i-gel with the cuffed tracheal tube during pressure-controlled ventilation. Br J Anaesth 2009; 102: 264-8.PubMedCrossRef
7.
go back to reference Wong DT, Yang JJ, Jagannathan N. Brief review: The LMA Supreme™ supraglottic airway. Can J Anesth 2012; 59: 483-93.PubMedCrossRef Wong DT, Yang JJ, Jagannathan N. Brief review: The LMA Supreme™ supraglottic airway. Can J Anesth 2012; 59: 483-93.PubMedCrossRef
8.
go back to reference Keller C, Brimacombe JR, Keller K, Morris R. Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients. Br J Anaesth 1999; 82: 286-7.PubMedCrossRef Keller C, Brimacombe JR, Keller K, Morris R. Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients. Br J Anaesth 1999; 82: 286-7.PubMedCrossRef
9.
go back to reference Brimacombe J, Berry A. A proposed fiber-optic scoring system to standardize the assessment of laryngeal mask airway position. Anesth Analg 1993; 76: 457.PubMed Brimacombe J, Berry A. A proposed fiber-optic scoring system to standardize the assessment of laryngeal mask airway position. Anesth Analg 1993; 76: 457.PubMed
10.
go back to reference Teoh WH, Lee KM, Suhitharan T, Tahaza Z, Teo MM, Sia AT. Comparison of the LMA Supreme vs the i-gel in paralysed patients undergoing gynaecological laparoscopic surgery with controlled ventilation. Anaesthesia 2010; 65: 1173-9.PubMedCrossRef Teoh WH, Lee KM, Suhitharan T, Tahaza Z, Teo MM, Sia AT. Comparison of the LMA Supreme vs the i-gel in paralysed patients undergoing gynaecological laparoscopic surgery with controlled ventilation. Anaesthesia 2010; 65: 1173-9.PubMedCrossRef
11.
go back to reference Russo SG, Cremer S, Eich C, et al. Magnetic resonance imaging study of the in vivo position of the extraglottic airway devices i-gel™ and LMA-Supreme™ in anaesthetized human volunteers. Br J Anaesth 2012; 109: 996-1004.PubMedCrossRef Russo SG, Cremer S, Eich C, et al. Magnetic resonance imaging study of the in vivo position of the extraglottic airway devices i-gel™ and LMA-Supreme™ in anaesthetized human volunteers. Br J Anaesth 2012; 109: 996-1004.PubMedCrossRef
12.
go back to reference Chew EE, Hashim NH, Wang CY. Randomised comparison of the LMA Supreme™ with the I-Gel™ in spontaneously breathing anaesthetised adult patients. Anaesth Intensive Care 2010; 38: 1018-22.PubMed Chew EE, Hashim NH, Wang CY. Randomised comparison of the LMA Supreme™ with the I-Gel™ in spontaneously breathing anaesthetised adult patients. Anaesth Intensive Care 2010; 38: 1018-22.PubMed
13.
go back to reference Russo SG, Cremer S, Galli T, et al. Randomized comparison of the i-gel™, the LMA Supreme™, and the Laryngeal Tube Suction-D using clinical and fibreoptic assessments in elective patients. BMC Anesthesiol 2012; 12: 18.PubMedCrossRefPubMedCentral Russo SG, Cremer S, Galli T, et al. Randomized comparison of the i-gel™, the LMA Supreme™, and the Laryngeal Tube Suction-D using clinical and fibreoptic assessments in elective patients. BMC Anesthesiol 2012; 12: 18.PubMedCrossRefPubMedCentral
14.
go back to reference Ragazzi R, Finessi L, Farinelli I, Alvisi R, Volta CA. LMA Supreme™ vs i-gel™ - a comparison of insertion success in novices. Anaesthesia 2012; 67: 384-8.PubMedCrossRef Ragazzi R, Finessi L, Farinelli I, Alvisi R, Volta CA. LMA Supreme™ vs i-gel™ - a comparison of insertion success in novices. Anaesthesia 2012; 67: 384-8.PubMedCrossRef
15.
go back to reference Chen X, Jiao J, Cong X, Liu L, Wu X. A comparison of the performance of the I-gel™ vs. the LMA-S™ during anesthesia: a meta-analysis of randomized controlled trials. PLoS One 2013; 8: e71910.PubMedCrossRefPubMedCentral Chen X, Jiao J, Cong X, Liu L, Wu X. A comparison of the performance of the I-gel™ vs. the LMA-S™ during anesthesia: a meta-analysis of randomized controlled trials. PLoS One 2013; 8: e71910.PubMedCrossRefPubMedCentral
16.
go back to reference Halwagi AE, Massicotte N, Lallo A, et al. Tracheal intubation through the I-gel™ supraglottic airway versus the LMA Fastrach™: a randomized controlled trial. Anesth Analg 2012; 114: 152-6.PubMedCrossRef Halwagi AE, Massicotte N, Lallo A, et al. Tracheal intubation through the I-gel™ supraglottic airway versus the LMA Fastrach™: a randomized controlled trial. Anesth Analg 2012; 114: 152-6.PubMedCrossRef
17.
go back to reference Michalek P, Donaldson W, Graham C, Hinds JD. A comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: a manikin study. Resuscitation 2010; 81: 74-7.PubMedCrossRef Michalek P, Donaldson W, Graham C, Hinds JD. A comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: a manikin study. Resuscitation 2010; 81: 74-7.PubMedCrossRef
18.
go back to reference Hernandez MR, Klock PA Jr, Ovassapian A. Evolution of the extraglottic airway: a review of its history, applications, and practical tips for success. Anesth Analg 2012; 114: 349-68.PubMedCrossRef Hernandez MR, Klock PA Jr, Ovassapian A. Evolution of the extraglottic airway: a review of its history, applications, and practical tips for success. Anesth Analg 2012; 114: 349-68.PubMedCrossRef
Metadata
Title
Randomized prospective trial comparing two supraglottic airway devices: i-gel™ and LMA-Supreme™ in paralyzed patients
Authors
Nikola Joly, MD
Louis-Pierre Poulin, MD
Issam Tanoubi, MD
Pierre Drolet, MD
François Donati, MD, PhD
Patrick St-Pierre, MD
Publication date
01-09-2014
Publisher
Springer US
Published in
Canadian Journal of Anesthesia/Journal canadien d'anesthésie / Issue 9/2014
Print ISSN: 0832-610X
Electronic ISSN: 1496-8975
DOI
https://doi.org/10.1007/s12630-014-0198-6

Other articles of this Issue 9/2014

Canadian Journal of Anesthesia/Journal canadien d'anesthésie 9/2014 Go to the issue