Haemodynamic and functional consequences of the iatrogenic atrial septal defect following Mitraclip therapy

Authors: E. A. Hart, K. Zwart, A. J. Teske, M. Voskuil, P. R. Stella, S. A. J. Chamuleau, A. O. Kraaijeveld

Published in: Netherlands Heart Journal | Issue 2/2017

Login to get access

Abstract

Percutaneous MitraClip placement for treatment of severe mitral regurgitation in high surgical risk patients is a commonly performed procedure and requires a transseptal puncture to reach the left atrium. The resulting iatrogenic atrial septal defect (iASD) is not routinely closed, yet the haemodynamic and functional consequences of a persisting defect are not fully understood. Despite positive effects such as acute left atrial pressure relief, persisting iASDs are associated with negative consequences, namely significant bidirectional shunting and subsequent worse clinical outcome. Percutaneous closure of the iASD may therefore be desirable in selected cases. In this review we discuss the available literature on this matter.
Literature
1.
go back to reference Feldman T, Kar S, Rinaldi M, et al. Percutaneous mitral repair with the MitraClip system. Safety and midterm durability in the initial EVEREST (Endovascular Valve Edge-to-Edge REpair Study) cohort. J Am Coll Cardiol. 2009;54:686–94.CrossRefPubMed Feldman T, Kar S, Rinaldi M, et al. Percutaneous mitral repair with the MitraClip system. Safety and midterm durability in the initial EVEREST (Endovascular Valve Edge-to-Edge REpair Study) cohort. J Am Coll Cardiol. 2009;54:686–94.CrossRefPubMed
2.
go back to reference Franzen O, Baldus S, Rudolph V, et al. Acute outcomes of MitraClip therapy for mitral regurgitation in high-surgical-risk patients: Emphasis on adverse valve morphology and severe left ventricular dysfunction. Eur Heart J. 2010;31:1373–81.CrossRefPubMed Franzen O, Baldus S, Rudolph V, et al. Acute outcomes of MitraClip therapy for mitral regurgitation in high-surgical-risk patients: Emphasis on adverse valve morphology and severe left ventricular dysfunction. Eur Heart J. 2010;31:1373–81.CrossRefPubMed
3.
go back to reference Whitlow PL, Feldman T, Pedersen WR, et al. Acute and 12-month results with catheter-based mitral valve leaflet repair: The EVEREST II (Endovascular Valve Edge-to-Edge Repair) High Risk Study. J Am Coll Cardiol. 2012;59:130–9.CrossRefPubMed Whitlow PL, Feldman T, Pedersen WR, et al. Acute and 12-month results with catheter-based mitral valve leaflet repair: The EVEREST II (Endovascular Valve Edge-to-Edge Repair) High Risk Study. J Am Coll Cardiol. 2012;59:130–9.CrossRefPubMed
4.
go back to reference Siegel RJ, Biner S, Rafique AM, et al. The acute hemodynamic effects of mitraclip therapy. J Am Coll Cardiol. 2011;57:1658–65.CrossRefPubMed Siegel RJ, Biner S, Rafique AM, et al. The acute hemodynamic effects of mitraclip therapy. J Am Coll Cardiol. 2011;57:1658–65.CrossRefPubMed
6.
go back to reference Feldman T, Wasserman HS, Herrmann HC, et al. Percutaneous mitral valve repair using the edge-to-edge technique: Six-month results of the EVEREST phase I clinical trial. J Am Coll Cardiol. 2005;46:2134–40.CrossRefPubMed Feldman T, Wasserman HS, Herrmann HC, et al. Percutaneous mitral valve repair using the edge-to-edge technique: Six-month results of the EVEREST phase I clinical trial. J Am Coll Cardiol. 2005;46:2134–40.CrossRefPubMed
7.
go back to reference Hammerstingl C, Lickfett L, Jeong K‑M, et al. Persistence of iatrogenic atrial septal defect after pulmonary vein isolation – an underestimated risk? Am Heart J. 2006;152:362.e1–362.e5.CrossRef Hammerstingl C, Lickfett L, Jeong K‑M, et al. Persistence of iatrogenic atrial septal defect after pulmonary vein isolation – an underestimated risk? Am Heart J. 2006;152:362.e1–362.e5.CrossRef
8.
go back to reference Chan NY, Choy CC, Lau CL, et al. Persistent iatrogenic atrial septal defect after pulmonary vein isolation by cryoballoon: An under-recognized complication. Europace. 2011;13:1406–10.CrossRefPubMed Chan NY, Choy CC, Lau CL, et al. Persistent iatrogenic atrial septal defect after pulmonary vein isolation by cryoballoon: An under-recognized complication. Europace. 2011;13:1406–10.CrossRefPubMed
9.
go back to reference Cequier A, Bonan R, Serra A, et al. Left-to-right atrial shunting after percutaneous mitral valvuloplasty. Circulation. 1990;81:1190–7.CrossRefPubMed Cequier A, Bonan R, Serra A, et al. Left-to-right atrial shunting after percutaneous mitral valvuloplasty. Circulation. 1990;81:1190–7.CrossRefPubMed
10.
go back to reference Howard SA, Quallich SG, Benscoter MA, et al. Tissue properties of the fossa ovalis as they relate to transseptal punctures: A translational approach. J Interv Cardiol. 2015;28:98–108.CrossRefPubMed Howard SA, Quallich SG, Benscoter MA, et al. Tissue properties of the fossa ovalis as they relate to transseptal punctures: A translational approach. J Interv Cardiol. 2015;28:98–108.CrossRefPubMed
11.
go back to reference Webb G, Gatzoulis MA. Atrial septal defects in the adult: Recent progress and overview. Circulation. 2006;114:1645–53.CrossRefPubMed Webb G, Gatzoulis MA. Atrial septal defects in the adult: Recent progress and overview. Circulation. 2006;114:1645–53.CrossRefPubMed
12.
go back to reference Singh SM, Douglas PS, Reddy VY. The incidence and long-term clinical outcome of iatrogenic atrial septal defects secondary to transseptal catheterization with a 12F transseptal sheath. Circ Arrhythmia Electrophysiol. 2011;4:166–71.CrossRef Singh SM, Douglas PS, Reddy VY. The incidence and long-term clinical outcome of iatrogenic atrial septal defects secondary to transseptal catheterization with a 12F transseptal sheath. Circ Arrhythmia Electrophysiol. 2011;4:166–71.CrossRef
13.
go back to reference Schueler R, Öztürk C, Wedekind JA, et al. Persistence of iatrogenic atrial septal defect after interventional mitral valve repair with the MitraClip system: a note of caution. JACC Cardiovasc Interv. 2015;8:450–9.CrossRefPubMed Schueler R, Öztürk C, Wedekind JA, et al. Persistence of iatrogenic atrial septal defect after interventional mitral valve repair with the MitraClip system: a note of caution. JACC Cardiovasc Interv. 2015;8:450–9.CrossRefPubMed
15.
go back to reference Smith T, McGinty P, Bommer W, et al. Prevalence and echocardiographic features of iatrogenic atrial septal defect after catheter-based mitral valve repair with the mitraclip system. Catheter Cardiovasc Interv. 2012;80:678–85.CrossRefPubMed Smith T, McGinty P, Bommer W, et al. Prevalence and echocardiographic features of iatrogenic atrial septal defect after catheter-based mitral valve repair with the mitraclip system. Catheter Cardiovasc Interv. 2012;80:678–85.CrossRefPubMed
16.
go back to reference Ussia GP, Cammalleri V, Marchei M, et al. Hemodynamic patterns of residual interatrial communication after transcatheter MitraClip repair. J Cardiovasc Med. 2014;15:343–9.CrossRef Ussia GP, Cammalleri V, Marchei M, et al. Hemodynamic patterns of residual interatrial communication after transcatheter MitraClip repair. J Cardiovasc Med. 2014;15:343–9.CrossRef
17.
go back to reference Saitoh T, Izumo M, Furugen A, et al. Echocardiographic evaluation of iatrogenic atrial septal defect after catheter-based mitral valve clip insertion. Am J Cardiol. 2012;109:1787–91.CrossRefPubMed Saitoh T, Izumo M, Furugen A, et al. Echocardiographic evaluation of iatrogenic atrial septal defect after catheter-based mitral valve clip insertion. Am J Cardiol. 2012;109:1787–91.CrossRefPubMed
18.
go back to reference Hoffmann R, Altiok E, Reith S, et al. Functional effect of new atrial septal defect after percutaneous mitral valve repair using the MitraClip device. Am J Cardiol. 2014;113:1228–33.CrossRefPubMed Hoffmann R, Altiok E, Reith S, et al. Functional effect of new atrial septal defect after percutaneous mitral valve repair using the MitraClip device. Am J Cardiol. 2014;113:1228–33.CrossRefPubMed
19.
go back to reference Huntgeburth M, Muller-Ehmsen J, Baldus S, et al. Postinterventional iatrogenic atrial septal defect with hemodynamically relevant left-to-right and right-to-left shunt as a complication of successful percutaneous mitral valve repair with the MitraClip. Int J Cardiol. 2013;168:e3–e5.CrossRefPubMed Huntgeburth M, Muller-Ehmsen J, Baldus S, et al. Postinterventional iatrogenic atrial septal defect with hemodynamically relevant left-to-right and right-to-left shunt as a complication of successful percutaneous mitral valve repair with the MitraClip. Int J Cardiol. 2013;168:e3–e5.CrossRefPubMed
20.
go back to reference Losi MA, Strisciuglio T, Stabile E, et al. Iatrogenic atrial septal defect (iASD) after MitraClip system delivery: The key role of PaO2/FiO2 ratio in guiding post-procedural iASD closure. Int J Cardiol. 2015;197:85–6.CrossRefPubMed Losi MA, Strisciuglio T, Stabile E, et al. Iatrogenic atrial septal defect (iASD) after MitraClip system delivery: The key role of PaO2/FiO2 ratio in guiding post-procedural iASD closure. Int J Cardiol. 2015;197:85–6.CrossRefPubMed
21.
go back to reference Chandraprakasam S, Satpathy R. When to close iatrogenic atrial septal defect after percutaneous edge to edge repair of mitral valve regurgitation. Cardiovasc Revasc Med. 2016;17:421–3.CrossRefPubMed Chandraprakasam S, Satpathy R. When to close iatrogenic atrial septal defect after percutaneous edge to edge repair of mitral valve regurgitation. Cardiovasc Revasc Med. 2016;17:421–3.CrossRefPubMed
22.
go back to reference Fitchet A, Turkie W, Fitzpatrick AP. Transseptal approach to ablation of left-sided arrhythmias does not lead to persisting interatrial shunt: a transesophageal echocardiographic study. Pacing Clin Electrophysiol. 1998;21:2070–2.CrossRefPubMed Fitchet A, Turkie W, Fitzpatrick AP. Transseptal approach to ablation of left-sided arrhythmias does not lead to persisting interatrial shunt: a transesophageal echocardiographic study. Pacing Clin Electrophysiol. 1998;21:2070–2.CrossRefPubMed
23.
go back to reference Fagundes RL, Mantica M, De Luca L, et al. Safety of single transseptal puncture for ablation of atrial fibrillation: Retrospective study from a large cohort of patients. J Cardiovasc Electrophysiol. 2007;18:1277–81.CrossRefPubMed Fagundes RL, Mantica M, De Luca L, et al. Safety of single transseptal puncture for ablation of atrial fibrillation: Retrospective study from a large cohort of patients. J Cardiovasc Electrophysiol. 2007;18:1277–81.CrossRefPubMed
24.
go back to reference Rillig A, Meyerfeldt U, Birkemeyer R, et al. Persistent iatrogenic atrial septal defect after pulmonary vein isolation: incidence and clinical implications. J Interv Card Electrophysiol. 2008;22:177–81.CrossRefPubMed Rillig A, Meyerfeldt U, Birkemeyer R, et al. Persistent iatrogenic atrial septal defect after pulmonary vein isolation: incidence and clinical implications. J Interv Card Electrophysiol. 2008;22:177–81.CrossRefPubMed
25.
go back to reference Omran H, Hardung D, Schmidt H, et al. Mechanical occlusion of the left atrial appendage. J Cardiovasc Electrophysiol. 2003;14:S56–S59.CrossRefPubMed Omran H, Hardung D, Schmidt H, et al. Mechanical occlusion of the left atrial appendage. J Cardiovasc Electrophysiol. 2003;14:S56–S59.CrossRefPubMed
26.
go back to reference Yoshida K, Yoshikawa J, Akasaka T, et al. Assessment of left-to-right atrial shunting after percutaneous mitral valvuloplasty by transesophageal color Doppler flow-mapping. Circulation. 1989;80:1521–6.CrossRefPubMed Yoshida K, Yoshikawa J, Akasaka T, et al. Assessment of left-to-right atrial shunting after percutaneous mitral valvuloplasty by transesophageal color Doppler flow-mapping. Circulation. 1989;80:1521–6.CrossRefPubMed
27.
go back to reference Ishikura F, Nagata S, Yasuda S, et al. Residual atrial septal perforation after percutaneous transvenous mitral commissurotomy with Inoue balloon catheter. Am Heart J. 1990;120:873–8.CrossRefPubMed Ishikura F, Nagata S, Yasuda S, et al. Residual atrial septal perforation after percutaneous transvenous mitral commissurotomy with Inoue balloon catheter. Am Heart J. 1990;120:873–8.CrossRefPubMed
28.
go back to reference Casale P, Block PC, O’Shea JP, et al. Atrial septal defect after percutaneous mitral balloon valvuloplasty: Immediate results and follow-up. J Am Coll Cardiol. 1990;15:1300–4.CrossRefPubMed Casale P, Block PC, O’Shea JP, et al. Atrial septal defect after percutaneous mitral balloon valvuloplasty: Immediate results and follow-up. J Am Coll Cardiol. 1990;15:1300–4.CrossRefPubMed
29.
go back to reference Liu TJ, Lai HC, Lee WL, et al. Immediate and late outcomes of patients undergoing transseptal left-sided heart catheterization for symptomatic valvular and arrhythmic diseases. Am Heart J. 2006;151:235–41.CrossRefPubMed Liu TJ, Lai HC, Lee WL, et al. Immediate and late outcomes of patients undergoing transseptal left-sided heart catheterization for symptomatic valvular and arrhythmic diseases. Am Heart J. 2006;151:235–41.CrossRefPubMed
30.
go back to reference McGinty PM, Smith TW, Rogers JH. Transseptal left heart catheterization and the incidence of persistent iatrogenic atrial septal defects. J Interv Cardiol. 2011;24:254–63.CrossRefPubMed McGinty PM, Smith TW, Rogers JH. Transseptal left heart catheterization and the incidence of persistent iatrogenic atrial septal defects. J Interv Cardiol. 2011;24:254–63.CrossRefPubMed
31.
go back to reference Hasenfuß G, Hayward C, Burkhoff D, et al. A transcatheter intracardiac shunt device for heart failure with preserved ejection fraction (REDUCE LAP-HF): A multicentre, open-label, single-arm, phase 1 trial. Lancet. 2016;387:1298–304.CrossRefPubMed Hasenfuß G, Hayward C, Burkhoff D, et al. A transcatheter intracardiac shunt device for heart failure with preserved ejection fraction (REDUCE LAP-HF): A multicentre, open-label, single-arm, phase 1 trial. Lancet. 2016;387:1298–304.CrossRefPubMed
32.
go back to reference Del Trigo M, Bergeron S, Bernier M, et al. Unidirectional left-to-right interatrial shunting for treatment of patients with heart failure with reduced ejection fraction: A safety and proof-of-principle cohort study. Lancet. 2016;387:1290–7.CrossRefPubMed Del Trigo M, Bergeron S, Bernier M, et al. Unidirectional left-to-right interatrial shunting for treatment of patients with heart failure with reduced ejection fraction: A safety and proof-of-principle cohort study. Lancet. 2016;387:1290–7.CrossRefPubMed
Metadata
Title
Haemodynamic and functional consequences of the iatrogenic atrial septal defect following Mitraclip therapy
Authors
E. A. Hart
K. Zwart
A. J. Teske
M. Voskuil
P. R. Stella
S. A. J. Chamuleau
A. O. Kraaijeveld
Publication date
01-02-2017
Publisher
Bohn Stafleu van Loghum
Published in
Netherlands Heart Journal / Issue 2/2017
Print ISSN: 1568-5888
Electronic ISSN: 1876-6250
DOI
https://doi.org/10.1007/s12471-016-0928-1

Other articles of this Issue 2/2017

Netherlands Heart Journal 2/2017 Go to the issue