Skip to main content
Top
Published in: Current Cardiovascular Imaging Reports 11/2014

01-11-2014 | Echocardiography (T Buck, Section Editor)

Real-Time Three-Dimensional Echocardiographic Flow Quantification in Valvular Heart Disease

Authors: Thomas Buck, Björn Plicht

Published in: Current Cardiovascular Imaging Reports | Issue 11/2014

Login to get access

Abstract

Besides providing unique anatomic information, real-time three-dimensional (3D) echocardiography (RT3DE) using color Doppler has the potential to overcome the limitations of flow quantification using conventional two-dimensional color Doppler methods. Recent studies have validated the application of color Doppler RT3DE for the assessment of flow based on the vena contracta area (VCA) and proximal isovelocity surface area as well as on mitral inflow minus aortic outflow. In particular, the assessment of VCA by color Doppler RT3DE led to a change of paradigm as a consequence of understanding the VCA as strongly asymmetric in the majority of patients and etiologies. In this review we provide a comprehensive discussion of the different concepts of RT3DE-based flow quantification in the setting of different valvular heart diseases and their presentation in the recent literature.
Literature
1.
go back to reference Yoganathan AP, Cape EG, Sung HW, Williams FP, Jimoh A. Review of hydrodynamic principles for the cardiologist: applications to the study of blood flow and jets by imaging techniques. J Am Coll Cardiol. 1988;12:1344–53.PubMedCrossRef Yoganathan AP, Cape EG, Sung HW, Williams FP, Jimoh A. Review of hydrodynamic principles for the cardiologist: applications to the study of blood flow and jets by imaging techniques. J Am Coll Cardiol. 1988;12:1344–53.PubMedCrossRef
2.
go back to reference Baumgartner H, Schima H, Kuhn P. Value and limitations of proximal jet dimensions for the quantitation of valvular regurgitation: an in vitro study using Doppler flow imaging. J Am Soc Echocardiogr. 1991;4:57–66.PubMedCrossRef Baumgartner H, Schima H, Kuhn P. Value and limitations of proximal jet dimensions for the quantitation of valvular regurgitation: an in vitro study using Doppler flow imaging. J Am Soc Echocardiogr. 1991;4:57–66.PubMedCrossRef
3.
go back to reference Fehske W, Omran H, Manz M, Kohler J, Hagendorff A, Luderitz B. Color-coded Doppler imaging of the vena contracta as a basis for quantification of pure mitral regurgitation. Am J Cardiol. 1994;73:268–74.PubMedCrossRef Fehske W, Omran H, Manz M, Kohler J, Hagendorff A, Luderitz B. Color-coded Doppler imaging of the vena contracta as a basis for quantification of pure mitral regurgitation. Am J Cardiol. 1994;73:268–74.PubMedCrossRef
4.
go back to reference Hall SA, Brickner ME, Willet DL, Irani WI, Afridi I, Grayburn PA. Assessment of mitral regurgitation severity by Doppler color flow mapping of the vena contracta. Circulation. 1997;95:636–42.PubMedCrossRef Hall SA, Brickner ME, Willet DL, Irani WI, Afridi I, Grayburn PA. Assessment of mitral regurgitation severity by Doppler color flow mapping of the vena contracta. Circulation. 1997;95:636–42.PubMedCrossRef
5.
go back to reference Schwammenthal E, Chen C, Benning F, Block M, Breithardt G, Levine RA. Dynamics of mitral regurgitant flow and orifice area – physiologic application of the proximal flow convergence method: clinical data and experimental testing. Circulation. 1994;90:307–22.PubMedCrossRef Schwammenthal E, Chen C, Benning F, Block M, Breithardt G, Levine RA. Dynamics of mitral regurgitant flow and orifice area – physiologic application of the proximal flow convergence method: clinical data and experimental testing. Circulation. 1994;90:307–22.PubMedCrossRef
6.••
go back to reference Khanna D, Vengala S, Miller AP, et al. Quantification of mitral regurgitation by live three-dimensional transthoracic echocardiographic measurements of vena contracta area. Echocardiography. 2004;21:737–43. First study demonstrating direct measurement of vena contracta area in RT3DE color Doppler datasets.PubMedCrossRef Khanna D, Vengala S, Miller AP, et al. Quantification of mitral regurgitation by live three-dimensional transthoracic echocardiographic measurements of vena contracta area. Echocardiography. 2004;21:737–43. First study demonstrating direct measurement of vena contracta area in RT3DE color Doppler datasets.PubMedCrossRef
7.•
go back to reference Yosefy C, Levine RA, Solis J, Vaturi M, Handschumacher MD, Hung J. Proximal flow convergence region as assessed by real-time 3-dimensional echocardiography: challenging the hemispheric assumption. J Am Soc Echocardiogr. 2007;20:389–96. First study demonstrating the hemielliptic shape of PISA in transthoracic real-time three-dimensional echocardiographic datasets. The authors found that only 1 of 50 patients had a hemispheric PISA contour by RT3DE. They also described significant underestimation of EROA by hemispheric 2D-PISA compared to 3D-based hemielliptic PISA.PubMedCrossRef Yosefy C, Levine RA, Solis J, Vaturi M, Handschumacher MD, Hung J. Proximal flow convergence region as assessed by real-time 3-dimensional echocardiography: challenging the hemispheric assumption. J Am Soc Echocardiogr. 2007;20:389–96. First study demonstrating the hemielliptic shape of PISA in transthoracic real-time three-dimensional echocardiographic datasets. The authors found that only 1 of 50 patients had a hemispheric PISA contour by RT3DE. They also described significant underestimation of EROA by hemispheric 2D-PISA compared to 3D-based hemielliptic PISA.PubMedCrossRef
8.••
go back to reference Kahlert P, Plicht B, Schenk IM, Janosi RA, Erbel R, Buck T. Direct assessment of size and shape of noncircular vena contracta area in functional versus organic mitral regurgitation using real-time three-dimensional echocardiography. J Am Soc Echocardiogr. 2008;21:912–21. First study systematically quantifying the asymmetry, shape and size of the vena contracta using real-time 3D echocardiography compared to 2D vena contracta as well as compared to 3D-based hemielliptic PISA and 2D hemispheric PISA, and the first study quantifying the underestimation of vena contracta area by 2D vena contracta and 2D PISA in different mitral regurgitation etiologies such as organic mitral regurgitation without prolapse or flail, organic mitral regurgitation with prolapse or flail, and functional mitral regurgitation. Kahlert P, Plicht B, Schenk IM, Janosi RA, Erbel R, Buck T. Direct assessment of size and shape of noncircular vena contracta area in functional versus organic mitral regurgitation using real-time three-dimensional echocardiography. J Am Soc Echocardiogr. 2008;21:912–21. First study systematically quantifying the asymmetry, shape and size of the vena contracta using real-time 3D echocardiography compared to 2D vena contracta as well as compared to 3D-based hemielliptic PISA and 2D hemispheric PISA, and the first study quantifying the underestimation of vena contracta area by 2D vena contracta and 2D PISA in different mitral regurgitation etiologies such as organic mitral regurgitation without prolapse or flail, organic mitral regurgitation with prolapse or flail, and functional mitral regurgitation.
9.
go back to reference Zoghbi WA, Enriquez-Sarano M, Foster E, et al. Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography. J Am Soc Echocardiogr. 2003;16:777–802.PubMedCrossRef Zoghbi WA, Enriquez-Sarano M, Foster E, et al. Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography. J Am Soc Echocardiogr. 2003;16:777–802.PubMedCrossRef
10.
go back to reference Lancellotti P, Moura L, Pierard LA, et al. European Association of Echocardiography recommendations for the assessment of valvular regurgitation. Part 2: mitral and tricuspid regurgitation (native valve disease). Eur J Echocardiogr. 2010;11:307–32.PubMedCrossRef Lancellotti P, Moura L, Pierard LA, et al. European Association of Echocardiography recommendations for the assessment of valvular regurgitation. Part 2: mitral and tricuspid regurgitation (native valve disease). Eur J Echocardiogr. 2010;11:307–32.PubMedCrossRef
11.
go back to reference Grayburn PA, Weissman NJ, Zamorano JL. Quantitation of mitral regurgitation. Circulation. 2012;126:2005–17.PubMedCrossRef Grayburn PA, Weissman NJ, Zamorano JL. Quantitation of mitral regurgitation. Circulation. 2012;126:2005–17.PubMedCrossRef
12.
go back to reference Vahanian A, Alfieri O, Andreotti F, et al. Guidelines on the management of valvular heart disease (version 2012). Eur Heart J. 2012;33:2451–96.PubMedCrossRef Vahanian A, Alfieri O, Andreotti F, et al. Guidelines on the management of valvular heart disease (version 2012). Eur Heart J. 2012;33:2451–96.PubMedCrossRef
13.
go back to reference Buck T. Valvular heart disease – insufficiencies. In: Buck T, Franke A, Monaghan MJ, editors. Three-dimensional echocardiography. Berlin Heidelberg: Springer; 2011. p. 109–54.CrossRef Buck T. Valvular heart disease – insufficiencies. In: Buck T, Franke A, Monaghan MJ, editors. Three-dimensional echocardiography. Berlin Heidelberg: Springer; 2011. p. 109–54.CrossRef
14.
go back to reference Buck T, Plicht B, Kahlert P, Erbel R. Understanding the asymmetrical vena contracta area: the difficult relationship between 2D and 3D measurements. JACC Cardiovasc Imaging. 2013;6:744.PubMedCrossRef Buck T, Plicht B, Kahlert P, Erbel R. Understanding the asymmetrical vena contracta area: the difficult relationship between 2D and 3D measurements. JACC Cardiovasc Imaging. 2013;6:744.PubMedCrossRef
15.
go back to reference Marsan NA, Westenberg JJ, Ypenburg C, et al. Quantification of functional mitral regurgitation by real-time 3D echocardiography: comparison with 3D velocity-encoded cardiac magnetic resonance. JACC Cardiovasc Imaging. 2009;2:1245–52.PubMedCrossRef Marsan NA, Westenberg JJ, Ypenburg C, et al. Quantification of functional mitral regurgitation by real-time 3D echocardiography: comparison with 3D velocity-encoded cardiac magnetic resonance. JACC Cardiovasc Imaging. 2009;2:1245–52.PubMedCrossRef
16.•
go back to reference Plicht B, Kahlert P, Goldwasser R, et al. Direct quantification of mitral regurgitant flow volume by real-time three-dimensional echocardiography using dealiasing of color Doppler flow at the vena contracta. J Am Soc Echocardiogr. 2008;21:1337–46. First description of quantification of regurgitant flow by dealiasing of color Doppler flow velocities at the vena contracta as a similar approach to that applied in cardiac MRI using phase-contrast velocity maps for flow quantification.PubMedCrossRef Plicht B, Kahlert P, Goldwasser R, et al. Direct quantification of mitral regurgitant flow volume by real-time three-dimensional echocardiography using dealiasing of color Doppler flow at the vena contracta. J Am Soc Echocardiogr. 2008;21:1337–46. First description of quantification of regurgitant flow by dealiasing of color Doppler flow velocities at the vena contracta as a similar approach to that applied in cardiac MRI using phase-contrast velocity maps for flow quantification.PubMedCrossRef
17.
go back to reference Skaug TR. Quantification of mitral regurgitation using high pulse repetition frequency three-dimensional color Doppler. J Am Soc Echocardiogr. 2010;23:1–8.PubMedCrossRef Skaug TR. Quantification of mitral regurgitation using high pulse repetition frequency three-dimensional color Doppler. J Am Soc Echocardiogr. 2010;23:1–8.PubMedCrossRef
18.
go back to reference Buck T, Mucci RA, Guerrero JL, Holmvang G, Handschumacher MD, Levine RA. Flow quantification in valvular heart disease based on the integral of backscattered acoustic power using Doppler ultrasound. Proc IEEE. 2000;88:307–30.CrossRef Buck T, Mucci RA, Guerrero JL, Holmvang G, Handschumacher MD, Levine RA. Flow quantification in valvular heart disease based on the integral of backscattered acoustic power using Doppler ultrasound. Proc IEEE. 2000;88:307–30.CrossRef
19.
go back to reference Buck T, Mucci RA, Guerrero JL, Holmvang G, Handschumacher MD, Levine RA. The power-velocity integral at the vena contracta – a new method for direct quantification of regurgitant volume flow. Circulation. 2000;102:1053–61.PubMedCrossRef Buck T, Mucci RA, Guerrero JL, Holmvang G, Handschumacher MD, Levine RA. The power-velocity integral at the vena contracta – a new method for direct quantification of regurgitant volume flow. Circulation. 2000;102:1053–61.PubMedCrossRef
20.
go back to reference Buck T, Plicht B, Hunold P, Mucci RA, Erbel R, Levine RA. Broad-beam spectral Doppler sonification of the vena contracta using matrix-array technology: a new solution for semi-automated quantification of mitral regurgitant flow volume and orifice area. J Am Coll Cardiol. 2005;45:770–9.PubMedCrossRef Buck T, Plicht B, Hunold P, Mucci RA, Erbel R, Levine RA. Broad-beam spectral Doppler sonification of the vena contracta using matrix-array technology: a new solution for semi-automated quantification of mitral regurgitant flow volume and orifice area. J Am Coll Cardiol. 2005;45:770–9.PubMedCrossRef
21.
go back to reference Buck T, Hwang SM, Plicht B, et al. Automated flow quantification in valvular heart disease based on backscattered Doppler power analysis: implementation on matrix-array ultrasound imaging systems. Int J Cardiovasc Imaging. 2008;24:463–77.PubMedCrossRef Buck T, Hwang SM, Plicht B, et al. Automated flow quantification in valvular heart disease based on backscattered Doppler power analysis: implementation on matrix-array ultrasound imaging systems. Int J Cardiovasc Imaging. 2008;24:463–77.PubMedCrossRef
22.
go back to reference Recusani F, Bargiggia GS, Yoganathan AP, Raisaro A. A new method for quantification of regurgitant flow rate using color flow imaging of the flow convergence region proximal to a discrete orifice: an vitro study. Circulation. 1991;83:594–604.PubMedCrossRef Recusani F, Bargiggia GS, Yoganathan AP, Raisaro A. A new method for quantification of regurgitant flow rate using color flow imaging of the flow convergence region proximal to a discrete orifice: an vitro study. Circulation. 1991;83:594–604.PubMedCrossRef
23.
go back to reference Utsunomiya T, Ogawa T, Doshi R, et al. Doppler color flow "proximal isovelocity surface area" method for estimating volume flow rate: effects of orifice shape and machine factors. J Am Coll Cardiol. 1991;17:1103–11.PubMedCrossRef Utsunomiya T, Ogawa T, Doshi R, et al. Doppler color flow "proximal isovelocity surface area" method for estimating volume flow rate: effects of orifice shape and machine factors. J Am Coll Cardiol. 1991;17:1103–11.PubMedCrossRef
24.
go back to reference Buck T, Jansen CHP, Yoganathan AP, Levine RA, Handschumacher MD. Hemisphere versus hemiellipse: when is each most accurate for proximal isovelocity calculation of regurgitant flows. J Am Coll Cardiol. 1998;31:385A.CrossRef Buck T, Jansen CHP, Yoganathan AP, Levine RA, Handschumacher MD. Hemisphere versus hemiellipse: when is each most accurate for proximal isovelocity calculation of regurgitant flows. J Am Coll Cardiol. 1998;31:385A.CrossRef
25.
go back to reference Iwakura K, Ito H, Kawano S, et al. Comparison of orifice area by transthoracic three-dimensional Doppler echocardiography versus proximal isovelocity surface area (PISA) method for assessment of mitral regurgitation. Am J Cardiol. 2006;97:1630–7.PubMedCrossRef Iwakura K, Ito H, Kawano S, et al. Comparison of orifice area by transthoracic three-dimensional Doppler echocardiography versus proximal isovelocity surface area (PISA) method for assessment of mitral regurgitation. Am J Cardiol. 2006;97:1630–7.PubMedCrossRef
26.
go back to reference Matsumura Y, Saracino G, Sugioka K, et al. Determination of regurgitant orifice area with the use of a new three-dimensional flow convergence geometric assumption in functional mitral regurgitation. J Am Soc Echocardiogr. 2008;21:1251–6.PubMedCrossRef Matsumura Y, Saracino G, Sugioka K, et al. Determination of regurgitant orifice area with the use of a new three-dimensional flow convergence geometric assumption in functional mitral regurgitation. J Am Soc Echocardiogr. 2008;21:1251–6.PubMedCrossRef
27.
go back to reference Ziani AB, Latcu DG, Abadir S, et al. Assessment of proximal isovelocity surface area (PISA) shape using three-dimensional echocardiography in a paediatric population with mitral regurgitation or ventricular shunt. Arch Cardiovasc Dis. 2009;102:185–91.PubMedCrossRef Ziani AB, Latcu DG, Abadir S, et al. Assessment of proximal isovelocity surface area (PISA) shape using three-dimensional echocardiography in a paediatric population with mitral regurgitation or ventricular shunt. Arch Cardiovasc Dis. 2009;102:185–91.PubMedCrossRef
28.
go back to reference Matsumura Y, Fukuda S, Tran H, et al. Geometry of the proximal isovelocity surface area in mitral regurgitation by 3-dimensional color Doppler echocardiography: difference between functional mitral regurgitation and prolapse regurgitation. Am Heart J. 2008;155:231–8.PubMedCrossRef Matsumura Y, Fukuda S, Tran H, et al. Geometry of the proximal isovelocity surface area in mitral regurgitation by 3-dimensional color Doppler echocardiography: difference between functional mitral regurgitation and prolapse regurgitation. Am Heart J. 2008;155:231–8.PubMedCrossRef
29.
go back to reference Cobey FC, McInnis JA, Gelfand BJ, Rapo MA, D'Ambra MN. A method for automating 3-dimensional proximal isovelocity surface area measurement. J Cardiothorac Vasc Anesth. 2012;26:507–11.PubMedCrossRef Cobey FC, McInnis JA, Gelfand BJ, Rapo MA, D'Ambra MN. A method for automating 3-dimensional proximal isovelocity surface area measurement. J Cardiothorac Vasc Anesth. 2012;26:507–11.PubMedCrossRef
30.
go back to reference Little SH, Igo SR, Pirat B, et al. In vitro validation of real-time three-dimensional color Doppler echocardiography for direct measurement of proximal isovelocity surface area in mitral regurgitation. Am J Cardiol. 2007;99:1440–7.PubMedCrossRefPubMedCentral Little SH, Igo SR, Pirat B, et al. In vitro validation of real-time three-dimensional color Doppler echocardiography for direct measurement of proximal isovelocity surface area in mitral regurgitation. Am J Cardiol. 2007;99:1440–7.PubMedCrossRefPubMedCentral
31.
go back to reference Li X, Shiota T, Delabays A, et al. Flow convergence flow rates from 3-dimensional reconstruction of color Doppler flow maps for computing transvalvular regurgitant flows without geometric assumptions: an in vitro quantitative flow study. J Am Soc Echocardiogr. 1999;12:1035–44.PubMedCrossRef Li X, Shiota T, Delabays A, et al. Flow convergence flow rates from 3-dimensional reconstruction of color Doppler flow maps for computing transvalvular regurgitant flows without geometric assumptions: an in vitro quantitative flow study. J Am Soc Echocardiogr. 1999;12:1035–44.PubMedCrossRef
32.
go back to reference Quaini A, Canic S, Guidoboni G, et al. A three-dimensional computational fluid dynamics model of regurgitant mitral valve flow: validation against in vitro standards and 3D color Doppler methods. Cardiovasc Eng Technol. 2011;2:77–89.PubMedCrossRefPubMedCentral Quaini A, Canic S, Guidoboni G, et al. A three-dimensional computational fluid dynamics model of regurgitant mitral valve flow: validation against in vitro standards and 3D color Doppler methods. Cardiovasc Eng Technol. 2011;2:77–89.PubMedCrossRefPubMedCentral
33.•
go back to reference Grady L, Datta S, Kutter O, et al. Regurgitation quantification using 3D PISA in volume echocardiography. Med Image Comput Comput Assist Interv. 2011;14:512–9. First description and in vitro and in vivo validation of a 3D analysis software for automated detection of 3D PISA in a 3D echocardiographic dataset.PubMed Grady L, Datta S, Kutter O, et al. Regurgitation quantification using 3D PISA in volume echocardiography. Med Image Comput Comput Assist Interv. 2011;14:512–9. First description and in vitro and in vivo validation of a 3D analysis software for automated detection of 3D PISA in a 3D echocardiographic dataset.PubMed
34.
go back to reference de Agustin JA, Marcos-Alberca P, Fernandez-Golfin C, et al. Direct measurement of proximal isovelocity surface area by single-beat three-dimensional color Doppler echocardiography in mitral regurgitation: a validation study. J Am Soc Echocardiogr. 2012;25:815–23.PubMedCrossRef de Agustin JA, Marcos-Alberca P, Fernandez-Golfin C, et al. Direct measurement of proximal isovelocity surface area by single-beat three-dimensional color Doppler echocardiography in mitral regurgitation: a validation study. J Am Soc Echocardiogr. 2012;25:815–23.PubMedCrossRef
35.••
go back to reference Thavendiranathan P, Liu S, Datta S, et al. Quantification of chronic functional mitral regurgitation by automated 3-dimensional peak and integrated proximal isovelocity surface area and stroke volume techniques using real-time 3-dimensional volume color Doppler echocardiography: in vitro and clinical validation. Circ Cardiovasc Imaging. 2013;6:125–33. First study demonstrating integrated 3D PISA over systole based on automated RT3DE color Doppler PISA calculation to be more accurate than peak 3D PISA times regurgitant flow velocity–time integral.PubMedCrossRef Thavendiranathan P, Liu S, Datta S, et al. Quantification of chronic functional mitral regurgitation by automated 3-dimensional peak and integrated proximal isovelocity surface area and stroke volume techniques using real-time 3-dimensional volume color Doppler echocardiography: in vitro and clinical validation. Circ Cardiovasc Imaging. 2013;6:125–33. First study demonstrating integrated 3D PISA over systole based on automated RT3DE color Doppler PISA calculation to be more accurate than peak 3D PISA times regurgitant flow velocity–time integral.PubMedCrossRef
36.
go back to reference Enriquez-Sarano M, Bailey KR, Seward JB, Tajik AJ, Krohn MJ, Mays JM. Quantitative Doppler assessment of valvular regurgitation. Circulation. 1993;87:841–8.PubMedCrossRef Enriquez-Sarano M, Bailey KR, Seward JB, Tajik AJ, Krohn MJ, Mays JM. Quantitative Doppler assessment of valvular regurgitation. Circulation. 1993;87:841–8.PubMedCrossRef
37.
go back to reference Sun JP, Pu M, Fouad FM, Christian R, Stewart WJ, Thomas JD. Automated cardiac output measurement by spatiotemporal integration of color Doppler data. In vitro and clinical validation. Circulation. 1997;95:932–9.PubMedCrossRef Sun JP, Pu M, Fouad FM, Christian R, Stewart WJ, Thomas JD. Automated cardiac output measurement by spatiotemporal integration of color Doppler data. In vitro and clinical validation. Circulation. 1997;95:932–9.PubMedCrossRef
38.
go back to reference Pemberton J, Li X, Kenny A, Davies CH, Minette MS, Sahn DJ. Real-time 3-dimensional Doppler echocardiography for the assessment of stroke volume: an in vivo human study compared with standard 2-dimensional echocardiography. J Am Soc Echocardiogr. 2005;18:1030–6.PubMedCrossRef Pemberton J, Li X, Kenny A, Davies CH, Minette MS, Sahn DJ. Real-time 3-dimensional Doppler echocardiography for the assessment of stroke volume: an in vivo human study compared with standard 2-dimensional echocardiography. J Am Soc Echocardiogr. 2005;18:1030–6.PubMedCrossRef
39.
go back to reference Pemberton J, Jerosch-Herold M, Li X, et al. Accuracy of real-time, three-dimensional Doppler echocardiography for stroke volume estimation compared with phase-encoded MRI: an in vivo study. Heart. 2008;94:1212–3.PubMedCrossRef Pemberton J, Jerosch-Herold M, Li X, et al. Accuracy of real-time, three-dimensional Doppler echocardiography for stroke volume estimation compared with phase-encoded MRI: an in vivo study. Heart. 2008;94:1212–3.PubMedCrossRef
40.
go back to reference Matthews F, Largiader T, Rhomberg P, van der LB, Schmid ER, Jenni R. A novel operator-independent algorithm for cardiac output measurements based on three-dimensional transoesophageal colour Doppler echocardiography. Eur J Echocardiogr. 2010;11:432–7. Matthews F, Largiader T, Rhomberg P, van der LB, Schmid ER, Jenni R. A novel operator-independent algorithm for cardiac output measurements based on three-dimensional transoesophageal colour Doppler echocardiography. Eur J Echocardiogr. 2010;11:432–7.
41.
go back to reference Lodato JA, Weinert L, Baumann R, et al. Use of 3-dimensional color Doppler echocardiography to measure stroke volume in human beings: comparison with thermodilution. J Am Soc Echocardiogr. 2007;20:103–12.PubMedCrossRef Lodato JA, Weinert L, Baumann R, et al. Use of 3-dimensional color Doppler echocardiography to measure stroke volume in human beings: comparison with thermodilution. J Am Soc Echocardiogr. 2007;20:103–12.PubMedCrossRef
42.
go back to reference Thavendiranathan P, Liu S, Datta S, et al. Automated quantification of mitral inflow and aortic outflow stroke volumes by three-dimensional real-time volume color-flow Doppler transthoracic echocardiography: comparison with pulsed-wave Doppler and cardiac magnetic resonance imaging. J Am Soc Echocardiogr. 2012;25:56–65.PubMedCrossRef Thavendiranathan P, Liu S, Datta S, et al. Automated quantification of mitral inflow and aortic outflow stroke volumes by three-dimensional real-time volume color-flow Doppler transthoracic echocardiography: comparison with pulsed-wave Doppler and cardiac magnetic resonance imaging. J Am Soc Echocardiogr. 2012;25:56–65.PubMedCrossRef
43.•
go back to reference Son JW, Chang HJ, Lee JK, et al. Automated quantification of mitral regurgitation by three dimensional real time full volume color Doppler transthoracic echocardiography: a validation with cardiac magnetic resonance imaging and comparison with two dimensional quantitative methods. J Cardiovasc Ultrasound. 2013;21:81–9. First study demonstrating new 3D analysis software based on automated quantification of mitral inflow and aortic outflow for calculation of mitral regurgitant flow volume.PubMedCrossRefPubMedCentral Son JW, Chang HJ, Lee JK, et al. Automated quantification of mitral regurgitation by three dimensional real time full volume color Doppler transthoracic echocardiography: a validation with cardiac magnetic resonance imaging and comparison with two dimensional quantitative methods. J Cardiovasc Ultrasound. 2013;21:81–9. First study demonstrating new 3D analysis software based on automated quantification of mitral inflow and aortic outflow for calculation of mitral regurgitant flow volume.PubMedCrossRefPubMedCentral
44.
go back to reference Thavendiranathan P, Phelan D, Thomas JD, Flamm SD, Marwick TH. Quantitative assessment of mitral regurgitation: validation of new methods. J Am Coll Cardiol. 2012;60:1470–83.PubMedCrossRef Thavendiranathan P, Phelan D, Thomas JD, Flamm SD, Marwick TH. Quantitative assessment of mitral regurgitation: validation of new methods. J Am Coll Cardiol. 2012;60:1470–83.PubMedCrossRef
45.
go back to reference Altiok E, Hamada S, van HS, et al. Comparison of direct planimetry of mitral valve regurgitation orifice area by three-dimensional transesophageal echocardiography to effective regurgitant orifice area obtained by proximal flow convergence method and vena contracta area determined by color Doppler echocardiography. Am J Cardiol. 2011;107:452–8. Altiok E, Hamada S, van HS, et al. Comparison of direct planimetry of mitral valve regurgitation orifice area by three-dimensional transesophageal echocardiography to effective regurgitant orifice area obtained by proximal flow convergence method and vena contracta area determined by color Doppler echocardiography. Am J Cardiol. 2011;107:452–8.
46.
go back to reference Chandra S, Salgo IS, Sugeng L, et al. A three-dimensional insight into the complexity of flow convergence in mitral regurgitation: adjunctive benefit of anatomic regurgitant orifice area. Am J Physiol Heart Circ Physiol. 2011;301:H1015–24.PubMedCrossRefPubMedCentral Chandra S, Salgo IS, Sugeng L, et al. A three-dimensional insight into the complexity of flow convergence in mitral regurgitation: adjunctive benefit of anatomic regurgitant orifice area. Am J Physiol Heart Circ Physiol. 2011;301:H1015–24.PubMedCrossRefPubMedCentral
47.
go back to reference Vergnat M, Jassar AS, Jackson BM, et al. Ischemic mitral regurgitation: a quantitative three-dimensional echocardiographic analysis. Ann Thorac Surg. 2011;91:157–64.PubMedCrossRefPubMedCentral Vergnat M, Jassar AS, Jackson BM, et al. Ischemic mitral regurgitation: a quantitative three-dimensional echocardiographic analysis. Ann Thorac Surg. 2011;91:157–64.PubMedCrossRefPubMedCentral
48.
go back to reference Otsuji Y, Handschumacher MD, Schwammenthal E, et al. Insights from three-dimensional echocardiography into the mechanism of functional mitral regurgitation: direct in vivo demonstration of altered leaflet tethering geometry. Circulation. 1997;96:1999–2008.PubMedCrossRef Otsuji Y, Handschumacher MD, Schwammenthal E, et al. Insights from three-dimensional echocardiography into the mechanism of functional mitral regurgitation: direct in vivo demonstration of altered leaflet tethering geometry. Circulation. 1997;96:1999–2008.PubMedCrossRef
49.
go back to reference Grigioni F, Enriquez-Sarano M, Zehr KJ, Bailey KR, Tajik AJ. Ischemic mitral regurgitation: long-term outcome and prognostic implications with quantitative Doppler assessment. Circulation. 2001;103:1759–64.PubMedCrossRef Grigioni F, Enriquez-Sarano M, Zehr KJ, Bailey KR, Tajik AJ. Ischemic mitral regurgitation: long-term outcome and prognostic implications with quantitative Doppler assessment. Circulation. 2001;103:1759–64.PubMedCrossRef
50.
go back to reference Little SH, Pirat B, Kumar R, et al. Three-dimensional color Doppler echocardiography for direct measurement of vena contracta area in mitral regurgitation: in vitro validation and clinical experience. JACC Cardiovasc Imaging. 2008;1:695–704.PubMedCrossRefPubMedCentral Little SH, Pirat B, Kumar R, et al. Three-dimensional color Doppler echocardiography for direct measurement of vena contracta area in mitral regurgitation: in vitro validation and clinical experience. JACC Cardiovasc Imaging. 2008;1:695–704.PubMedCrossRefPubMedCentral
51.
go back to reference Shanks M, Siebelink HM, Delgado V, et al. Quantitative assessment of mitral regurgitation: comparison between three-dimensional transesophageal echocardiography and magnetic resonance imaging. Circ Cardiovasc Imaging. 2010;3:694–700.PubMedCrossRef Shanks M, Siebelink HM, Delgado V, et al. Quantitative assessment of mitral regurgitation: comparison between three-dimensional transesophageal echocardiography and magnetic resonance imaging. Circ Cardiovasc Imaging. 2010;3:694–700.PubMedCrossRef
52.
go back to reference Yosefy C, Hung J, Chua S, et al. Direct measurement of vena contracta area by real-time 3-dimensional echocardiography for assessing severity of mitral regurgitation. Am J Cardiol. 2009;104:978–83.PubMedCrossRefPubMedCentral Yosefy C, Hung J, Chua S, et al. Direct measurement of vena contracta area by real-time 3-dimensional echocardiography for assessing severity of mitral regurgitation. Am J Cardiol. 2009;104:978–83.PubMedCrossRefPubMedCentral
53.
go back to reference Hyodo E, Iwata S, Tugcu A, et al. Direct measurement of multiple vena contracta areas for assessing the severity of mitral regurgitation using 3D TEE. JACC Cardiovasc Imaging. 2012;5:669–76.PubMedCrossRef Hyodo E, Iwata S, Tugcu A, et al. Direct measurement of multiple vena contracta areas for assessing the severity of mitral regurgitation using 3D TEE. JACC Cardiovasc Imaging. 2012;5:669–76.PubMedCrossRef
54.
go back to reference Zeng X, Levine RA, Hua L, et al. Diagnostic value of vena contracta area in the quantification of mitral regurgitation severity by color Doppler 3D echocardiography. Circ Cardiovasc Imaging. 2011;4:506–13.PubMedCrossRefPubMedCentral Zeng X, Levine RA, Hua L, et al. Diagnostic value of vena contracta area in the quantification of mitral regurgitation severity by color Doppler 3D echocardiography. Circ Cardiovasc Imaging. 2011;4:506–13.PubMedCrossRefPubMedCentral
55.
go back to reference Hopmeyer J, He S, Thorvig KM, et al. Estimation of mitral regurgitation with a hemielliptic curve-fitting algorithm: in vitro experiments with native mitral valves. J Am Soc Echocardiogr. 1998;11:322–31.PubMedCrossRef Hopmeyer J, He S, Thorvig KM, et al. Estimation of mitral regurgitation with a hemielliptic curve-fitting algorithm: in vitro experiments with native mitral valves. J Am Soc Echocardiogr. 1998;11:322–31.PubMedCrossRef
56.
go back to reference Choi J, Heo R, Hong GR, et al. Differential effect of 3-dimensional color Doppler echocardiography for the quantification of mitral regurgitation according to the severity and characteristics. Circ Cardiovasc Imaging. 2014;7:535–44.PubMedCrossRef Choi J, Heo R, Hong GR, et al. Differential effect of 3-dimensional color Doppler echocardiography for the quantification of mitral regurgitation according to the severity and characteristics. Circ Cardiovasc Imaging. 2014;7:535–44.PubMedCrossRef
57.
go back to reference Buck T, Plicht B, Kahlert P, Schenk IM, Hunold P, Erbel R. Effect of dynamic flow rate and orifice area on mitral regurgitant stroke volume quantification using the proximal isovelocity surface area method. J Am Coll Cardiol. 2008;52:767–78.PubMedCrossRef Buck T, Plicht B, Kahlert P, Schenk IM, Hunold P, Erbel R. Effect of dynamic flow rate and orifice area on mitral regurgitant stroke volume quantification using the proximal isovelocity surface area method. J Am Coll Cardiol. 2008;52:767–78.PubMedCrossRef
58.
go back to reference Chu JW, Levine RA, Chua S, et al. Assessing mitral valve area and orifice geometry in calcific mitral stenosis: a new solution by real-time three-dimensional echocardiography. J Am Soc Echocardiogr. 2008;21:1006–9.PubMedCrossRefPubMedCentral Chu JW, Levine RA, Chua S, et al. Assessing mitral valve area and orifice geometry in calcific mitral stenosis: a new solution by real-time three-dimensional echocardiography. J Am Soc Echocardiogr. 2008;21:1006–9.PubMedCrossRefPubMedCentral
59.
go back to reference Zamorano J, Cordeiro P, Sugeng L, et al. Real-time three-dimensional echocardiography for rheumatic mitral valve stenosis evaluation: an accurate and novel approach. J Am Coll Cardiol. 2004;43:2091–6.PubMedCrossRef Zamorano J, Cordeiro P, Sugeng L, et al. Real-time three-dimensional echocardiography for rheumatic mitral valve stenosis evaluation: an accurate and novel approach. J Am Coll Cardiol. 2004;43:2091–6.PubMedCrossRef
60.
go back to reference de Agustin JA, Mejia H, Viliani D, et al. Proximal flow convergence method by three-dimensional color Doppler echocardiography for mitral valve area assessment in rheumatic mitral stenosis. J Am Soc Echocardiogr. 2014;27:838–45.PubMedCrossRef de Agustin JA, Mejia H, Viliani D, et al. Proximal flow convergence method by three-dimensional color Doppler echocardiography for mitral valve area assessment in rheumatic mitral stenosis. J Am Soc Echocardiogr. 2014;27:838–45.PubMedCrossRef
61.
go back to reference Fang L, Hsiung MC, Miller AP, et al. Assessment of aortic regurgitation by live three-dimensional transthoracic echocardiographic measurements of vena contracta area: usefulness and validation. Echocardiography. 2005;22:775–81.PubMedCrossRef Fang L, Hsiung MC, Miller AP, et al. Assessment of aortic regurgitation by live three-dimensional transthoracic echocardiographic measurements of vena contracta area: usefulness and validation. Echocardiography. 2005;22:775–81.PubMedCrossRef
62.
go back to reference Chin CH, Chen CH, Lo HS. The correlation between three-dimensional vena contracta area and aortic regurgitation index in patients with aortic regurgitation. Echocardiography. 2010;27:161–6.PubMedCrossRef Chin CH, Chen CH, Lo HS. The correlation between three-dimensional vena contracta area and aortic regurgitation index in patients with aortic regurgitation. Echocardiography. 2010;27:161–6.PubMedCrossRef
63.
go back to reference Ewe SH, Delgado V, van der GR, et al. Accuracy of three-dimensional versus two-dimensional echocardiography for quantification of aortic regurgitation and validation by three-dimensional three-directional velocity-encoded magnetic resonance imaging. Am J Cardiol. 2013;112:560–6. Ewe SH, Delgado V, van der GR, et al. Accuracy of three-dimensional versus two-dimensional echocardiography for quantification of aortic regurgitation and validation by three-dimensional three-directional velocity-encoded magnetic resonance imaging. Am J Cardiol. 2013;112:560–6.
64.•
go back to reference Poh KK, Levine RA, Solis J, et al. Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography. Eur Heart J. 2008;29:2526–35. First study using automated integration of color Doppler flow velocities over RT3DE-derived left ventricular outflow tract area to increase the accuracy of aortic valve area calculation in aortic stenosis using the continuity equation.PubMedCrossRefPubMedCentral Poh KK, Levine RA, Solis J, et al. Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography. Eur Heart J. 2008;29:2526–35. First study using automated integration of color Doppler flow velocities over RT3DE-derived left ventricular outflow tract area to increase the accuracy of aortic valve area calculation in aortic stenosis using the continuity equation.PubMedCrossRefPubMedCentral
65.
go back to reference Tribouilloy CM, Enriquez-Sarano M, Bailey KR, Tajik AJ, Seward JB. Quantification of tricuspid regurgitation by measuring the width of the vena contracta with Doppler color flow imaging: a clinical study. J Am Coll Cardiol. 2000;36:472–8.PubMedCrossRef Tribouilloy CM, Enriquez-Sarano M, Bailey KR, Tajik AJ, Seward JB. Quantification of tricuspid regurgitation by measuring the width of the vena contracta with Doppler color flow imaging: a clinical study. J Am Coll Cardiol. 2000;36:472–8.PubMedCrossRef
66.
go back to reference de Agustin JA, Viliani D, Vieira C, et al. Proximal isovelocity surface area by single-beat three-dimensional color Doppler echocardiography applied for tricuspid regurgitation quantification. J Am Soc Echocardiogr. 2013;26:1063–72.PubMedCrossRef de Agustin JA, Viliani D, Vieira C, et al. Proximal isovelocity surface area by single-beat three-dimensional color Doppler echocardiography applied for tricuspid regurgitation quantification. J Am Soc Echocardiogr. 2013;26:1063–72.PubMedCrossRef
67.
go back to reference Zamorano JL, de Agustin JA. Valvular heart disease – stenoses. In: Buck T, Franke A, Monaghan MJ, editors. Three-dimensional echocardiography. Berlin Heidelberg: Springer; 2011. p. 155–74.CrossRef Zamorano JL, de Agustin JA. Valvular heart disease – stenoses. In: Buck T, Franke A, Monaghan MJ, editors. Three-dimensional echocardiography. Berlin Heidelberg: Springer; 2011. p. 155–74.CrossRef
Metadata
Title
Real-Time Three-Dimensional Echocardiographic Flow Quantification in Valvular Heart Disease
Authors
Thomas Buck
Björn Plicht
Publication date
01-11-2014
Publisher
Springer US
Published in
Current Cardiovascular Imaging Reports / Issue 11/2014
Print ISSN: 1941-9066
Electronic ISSN: 1941-9074
DOI
https://doi.org/10.1007/s12410-014-9298-5

Other articles of this Issue 11/2014

Current Cardiovascular Imaging Reports 11/2014 Go to the issue